NEO-RAY DESCRIPTION The Nimbus II series offers simple design and flexibility without sacrificing performance. Multiple lamp configurations in T8 and T5 high output fluorescent provide maximum flexibility for the architectural environment. In addition, the Nimbus II is modular with suspension points falling on exact 48" increments for ease of installation. Nimbus II creates a comfortable and uniformly balanced environment. All of these elements combined make the Nimbus II an excellent selection for large open office areas, VDT workspaces, classrooms and virtually any open space. Type Catalog # Project Date Comments Prepared by SPECIFICATION FEATURES A ... Construction Housing is one piece die-formed cold rolled steel, forming a 9" x 2-1/2" architectural profile. Perforated sections are 33% open with 5/32" staggered hole pattern and opal diffuser. Standard 4'-0", 8'-0" and 12'-0" fixture lengths combine for continuous runs. C ... Reflectors Die-formed, highly specular aluminum. D ... Electrical Luminaires are prewired with quick wire connectors and use UL list Class P, 265ma T8 electronic ballasts. Power factor of 95% with less than 20% THD. Fixtures and electrical components certified to UL and CUL standards. Note: Please consult factory, Fifthlight may not be available in some configured options. B ... End Caps End caps are precision die-cast aluminum mechanically attached without exposed fasteners. A C D END CAP E Nimbus II 701-IP B 9" [229mm] 2T8 2-1/2" [63mm] SUSPENDED 2-1/2" [63mm] SEMI-INDIRECT 5" [127mm] 9" [229mm] Light Distribution Indirect - 94.1% Direct - 5.9% M O D U L A R R O W C O N F I G U R AT I O N • Standard length sections join easily to create rows. • Sections align with T-grid. • All sections prewired for through-wiring with quick connectors. S TA N D A R D L U M I N A I R E L E N G T H S ORDERING INFORMATION Sample Number: 701IP-SP-2T8-1C-277-DC48-T1-48 Series 701IP=Nimbus II Number of Lamps 2=2 Lamps Optics Up S=Specular Lamp Type T8=T8 Normal Output Optics Down P=Perforated Number of Circuits 1=1 Circuit 1 Wiring 1 B=Battery Pack Voltage 1 120=120V Power Feed 1 C=Straight Cord Ceiling Type T1=1'' T-Bar C=Standard Circuit D=Dimming 277=277V 347=347V K=Curly Cord P=Rigid Pendant T9=9/16'' T-Bar TS=Slotted T-Bar E=Emergency T=Nightlight UNV=Universal (120V277V) Suspension Length ST=Structure JB=4'' Octagonal J-Box Y=Daylight 2=2 Circuits (Side by Side) Suspension A=Aircraft Cable Pendant 2 P=Rigid (single stem) Adjustable Cable 48", 120", 240", 300", or 360" (infinite adjustment along entire length of cable) Rigid Pendant 3 12", 15", 18", 21", 24", or 27" D=Dual Aircraft Cable OR Dual Swivel Rigid Pendant Notes: 1 Run Length Individually Mounted Luminaires may be 4', 8', or 12' in length Continuously Mounted Standard row configurations over 12' consist of 8' and 12' sections Not all options available. Please consult your Cooper Lighting Representative for availability. 2 Available with 7° or earthquake 45° swivel canopy assembly. 3 Consult factory for custom rigid pendant lengths. Specifications and Dimensions subject to change without notice. Consult your representative for additional options and finishes. ADN041796 09/19/2013 1:00:02 PM Nimbus II 701-IP PHOTOMETRICS Coefficients of Utilization rc rw RCR 0 1 2 3 4 5 6 7 8 9 701IP-2T5 (2) FP54/841/HO 4500 Lumens 10 Candela Effective floor cavity reflectance 80% 70% 20% 50% 30% 10% 0% 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0 87 79 72 66 87 76 66 58 87 72 61 52 87 69 56 47 75 68 62 57 75 65 57 50 75 63 53 45 75 60 49 41 53 46 40 36 53 45 38 33 53 43 36 30 33 29 25 22 33 28 24 21 33 27 23 19 15 13 11 10 15 13 11 09 15 12 10 09 06 05 04 04 60 55 50 46 51 44 40 36 44 38 33 29 39 33 29 25 51 47 43 40 44 39 35 31 39 34 29 26 35 29 25 22 32 28 25 22 28 24 21 19 25 21 18 16 20 18 16 14 18 15 14 12 16 14 12 10 09 08 07 06 08 07 06 05 07 06 06 05 03 03 02 02 42 39 37 32 26 21 29 23 19 26 20 16 06 05 04 05 04 04 05 04 03 02 01 01 37 28 23 19 34 25 20 16 32 23 18 14 20 16 14 18 15 12 17 13 11 13 11 09 12 09 08 11 08 07 Efficiency 89.9% Zonal Lumen Summary Test Report #LSI15721 Luminance Data Zone Lumens %Lamp %Fixture 0-30 0-40 0-60 142 231 404 1.59 2.57 4.49 1.76 2.86 4.99 0-90 40-90 60-90 90-180 548 316 144 7543 6.09 3.52 1.60 83.82 6.78 3.92 1.78 93.22 0-180 8091 89.91 100.00 Angle in Deg 45 0-Deg cd/sm 1321 45-Deg cd/sm 1427 90-Deg cd/sm 1532 55 65 75 85 1097 843 521 0 1411 1465 1496 1040 1665 1716 1675 1343 Angle 0 Along II 187 45° 187 Across ⊥ 187 5 15 25 35 187 174 157 136 187 179 165 143 185 177 168 146 45 55 65 75 109 74 42 16 118 94 71 51 126 111 88 70 85 90 95 105 0 0 60 322 26 15 327 904 44 30 297 899 115 125 135 145 631 932 1199 1423 1402 1561 1641 1782 1616 1918 1968 1921 155 165 175 180 1597 1716 1777 1773 1847 1816 1774 1773 1957 1883 1759 1773 MOUNTING INFORMATION St a n d ar d J oi ni n g – Du a l ai rcraf t cable precisely aligns with suspended til e ceil ing. 48" 48" 96" 96" 144" 144" Beginning or end of run Intermediate Specifications and Dimensions subject to change without notice. Neo-Ray • Customer First Center • 1121 Highway 74 South • Peachtree City, GA 30269 • TEL 770.486.4800 • FAX 770.486.4801 ADN041796 09/19/2013 1:00:02 PM