NEO-RAY DESCRIPTION The Nimbus II series offers simple design and flexibility without sacrificing performance. Multiple lamp configurations in T8 and T5 high output fluorescent provide maximum flexibility for the architectural environment. In addition, the Nimbus II is modular with suspension points falling on exact 48" increments for ease of installation. Nimbus II creates a comfortable and uniformly balanced environment. All of these elements combined make the Nimbus II an excellent selection for large open office areas, VDT workspaces, classrooms and virtually any open space. Type Catalog # Project Date Comments Prepared by SPECIFICATION FEATURES A ... Construction Housing is one piece die-formed cold rolled steel, forming a 9" x 2-1/2" architectural profile. Perforated sections are 33% open with 5/32" staggered hole pattern and opal diffuser. Standard 4'-0", 8'-0" and 12'-0" fixture lengths combine for continuous runs. C ... Reflectors Die-formed, highly specular aluminum. D ... Electrical Luminaires are prewired with quick wire connectors and use UL list Class P, 265ma T8 electronic ballasts. Power factor of 95% with less than 20% THD. Fixtures and electrical components certified to UL and CUL standards. Note: Please consult factory, Fifthlight may not be available in some configured options. B ... End Caps End caps are precision die-cast aluminum mechanically attached without exposed fasteners. A C D E END CAP Nimbus II 701-IP B 9" [229mm] 4T8 2-1/2" [63mm] SUSPENDED 2-1/2" [63mm] 9" [229mm] SEMI-INDIRECT 5" [127mm] Light Distribution Indirect - 92.8% Direct - 7.2% M O D U L A R R O W C O N F I G U R AT I O N • Standard length sections join easily to create rows. • Sections align with T-grid. • All sections prewired for through-wiring with quick connectors. S TA N D A R D L U M I N A I R E L E N G T H S ORDERING INFORMATION Sample Number: 701IP-SP-4T8-1C-277-DC48-T1-48 Series 701IP=Nimbus II Number of Lamps 4=4 Lamps Optics Up S=Specular Lamp Type T8=T8 Normal Output Optics Down P=Perforated Number of Circuits 1=1 Circuit 1 Wiring 1 B=Battery Pack Voltage 1 120=120V Power Feed 1 C=Straight Cord Ceiling Type T1=1'' T-Bar C=Standard Circuit D=Dimming 277=277V 347=347V K=Curly Cord P=Rigid Pendant T9=9/16'' T-Bar TS=Slotted T-Bar E=Emergency T=Nightlight UNV=Universal (120V277V) Suspension Length ST=Structure JB=4'' Octagonal J-Box Y=Daylight Suspension A=Aircraft Cable 2=2 Circuits (Inboard/Outboard) P=Rigid Pendant 2 (single stem) Adjustable Cable 48", 120", 240", 300", or 360" (infinite adjustment along entire length of cable) Rigid Pendant 3 12", 15", 18", 21", 24", or 27" D=Dual Aircraft Cable OR Dual Swivel Rigid Pendant Notes: 1 Run Length Individually Mounted Luminaires may be 4', 8', or 12' in length Continuously Mounted Standard row configurations over 12' consist of 8' and 12' sections Not all options available. Please consult your Cooper Lighting Representative for availability. 2 Available with 7° or earthquake 45° swivel canopy assembly. 3 Consult factory for custom rigid pendant lengths. Specifications and Dimensions subject to change without notice. Consult your representative for additional options and finishes. ADN041798 09/19/2013 1:05:39 PM Nimbus II 701-IP PHOTOMETRICS Coefficients of Utilization rc rw RCR 0 1 2 3 4 5 6 7 8 9 701IP-4T8 (4) F32T8/TL841 2950 Lumens 10 Candela Effective floor cavity reflectance 80% 70% 20% 50% 30% 10% 0% 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0 80 73 66 60 80 69 60 53 80 66 56 48 80 64 52 43 69 63 57 52 69 60 52 46 69 58 48 42 69 55 45 38 49 43 37 33 49 41 35 30 49 40 33 28 31 27 23 21 31 26 22 19 31 25 21 18 14 12 11 09 14 12 10 09 14 12 10 08 06 05 04 03 55 50 46 42 47 41 37 33 41 35 31 27 36 31 26 23 47 43 40 37 41 36 32 29 36 31 27 24 32 27 23 20 29 26 23 21 26 22 20 17 23 20 17 15 18 16 15 13 17 14 13 11 15 13 11 10 08 07 07 06 08 07 06 05 07 06 05 05 03 03 02 02 39 36 34 30 24 20 27 21 17 24 19 15 05 05 04 05 04 03 05 04 03 02 01 01 34 26 21 17 31 23 18 15 29 21 17 13 19 15 13 17 14 11 15 12 10 12 10 08 11 09 07 10 08 06 Efficiency 82.6% Zonal Lumen Summary Test Report #LSI15713 Luminance Data Zone Lumens %Lamp %Fixture 0-30 0-40 0-60 185 300 521 1.57 2.54 4.42 1.90 3.08 5.35 0-90 40-90 60-90 90-180 701 401 180 9045 5.95 3.40 1.53 76.66 7.20 4.12 1.85 92.80 0-180 9747 82.60 100.00 Angle in Deg 45 0-Deg cd/sm 1690 45-Deg cd/sm 1833 90-Deg cd/sm 2019 55 65 75 85 1443 958 682 158 1773 1899 1767 1220 2104 2193 2067 1680 Angle 0 Along II 243 45° 243 Across ⊥ 243 5 15 25 35 242 231 211 175 241 231 211 184 241 232 212 192 45 55 65 75 140 97 47 21 152 119 92 61 167 140 113 86 85 90 95 105 2 0 76 427 30 34 199 766 55 61 220 767 115 840 125 135 145 1247 1615 1929 1478 1886 2199 2392 1480 2141 2421 2613 155 165 175 180 2172 2342 2425 2421 2435 2456 2428 2421 2645 2542 2432 2421 MOUNTING INFORMATION S t a nd ar d Jo i n in g – Dua l ai rcra f t cable precisely aligns with suspended t ile cei li ng. 48" 48" 96" 96" 144" 144" Beginning or end of run Intermediate Specifications and Dimensions subject to change without notice. Neo-Ray • Customer First Center • 1121 Highway 74 South • Peachtree City, GA 30269 • TEL 770.486.4800 • FAX 770.486.4801 ADN041798 09/19/2013 1:05:39 PM