MWS

advertisement
MWS
D es c r ip tion
MWS, Modular Wiring Systems, provides low cost installation of branch
circuit wiring for lighting and power. Using modular components
that plug together, MWS can be installed in a fraction of the time of
hardwiring. Plus, MWS offers the advantage of relocating fixtures and
outlets in future renovations.
®
Type
Catalog #
Project
Date
Comments
The MWS Starter Fixture Cable (SF) starts the MWS circuit immediately
at the electrical junction box or switch box and continues to the first
lighting fixture. Subsequent fixtures connected to the Starter Fixture
Cable are wired with standard Fixture Cables (FC) or Extender Cable (EC).
Prepared by
Des ign Fea tur es
• UL Listed under Standard 183 for
make or break under load.
• Meets requirements of Article 604
of the National Electrical Code.
• MWS componenets assembled
with 12 AWG/10 AWG conductors
rated at 20 amperes with full size
ground wire.
• THHN insulated conductors rated
at 90°C with 16 AWG solid TFN
fixture leads. All leads come with
pushwire connectors.
• Galvanized steel exterior with
integral keying for voltage and
amperage.
• 6" leads w/quick connects for easy
fixture wiring connection.
All unused outlets require a MWS
dust cover. MWS ST, SP, SD , C T
and TC are shipped with one dust
cover attached.
• Valox 365 constructed
contact housing approved for
environmental air plenums.
• Positive self-grounding locking
clip fits into any 1/2" KO on fixture.
• Unique double-blade contact
ensures proper mating of electrical
components to prevent pushback
or pullout.
SF
Starter Fixture
Cable
D im ens iona l D a ta
Modular Wiring System
3/4" [19mm]
Side
Front
Quick
Connect
4-3/8"
[112mm]
Top
MWS AUTOCAD DRAFTING
MWS offers AutoCAD
drafting to layout
MWS, providing the
contractor with
additional benefits.
Ord er ing I nf or m at i o n
S A M P L E N U M B E R : 2 7 SF 1 2 /2 G 0 9
SF
Component
SF=Starter
Fixture Cable
Conductors and Size
12/2G=#12, 2 Conductor Plus Ground
12/3G=#12, 3 Conductor Plus Ground
12/4G=#12, 4 Conductor Plus Ground
Cable Length (Feet)
09=9'
15=15'
21=21'
Options
2N=2 Neutral (1)
Bills of material are computer-generated
guaranteeing accuracy.
MWS drawing symbols and details
standardized.
Layouts are available on CD or e-mail.
To utilize this service and for additional
information, contact the MWS Sales
Department (888) 487-4887.
(1)
NOTES: 12/4G only.
Specifications & dimensions subject to change without notice. Consult your Cooper Lighting
Representative for availability and ordering information.
SH IP P ING D ATA
Install dust covers on unused open ends.
Scale is exaggerated on fixtures and
MWS system applications.
YS
TEM
S
S
CableUnitStandard
Length
Wt.Qty./Carton
9'
3.0 lbs.
9
15'
4.5 lbs.
6
21'
6.3 lbs.
4
All electrical boxes, conduit, connections
and switches by others.
Specifications and dimensions subject to change without notice.
ER
C
Consult your representative for additional options and finishes.
D
Voltage
12=120V
27=277V
34=347V
MWS design layout time is reduced.
TIFIE
ADF031842
2013-02-05 16:23:46
Download