MWS

advertisement
MWS
D ES C R IPTION
MWS-5LT, Modular Wiring Systems with DALI Control, provides low
cost installation of both power for lighting and Class 1 control wiring for
use with Fifth Light DALI systems. Using modular components that plug
together, MWS-5LT can be installed in a fraction of the time of hardwiring
both lighting and control. Plus, MWS-5LT offers the advantage of
relocating fixtures and DALI control devices for future renovations.
®
Type
Catalog #
Project
Date
Comments
The MWS Drop Cable with DALI Control (DC-5LT) feeds power and control to wall or ceiling fixtures from a compatible Circuit T (CT) or Splitter
(SP). See the CT or SP specification sheets for compatibility details.
Prepared by
MWS Drop cables may be plugged into the last fixture cable (FC) or from
a Splitter (SP) anywhere within the system.
D ES IGN FEA TUR ES
• UL Listed under Standard 183 for
make or break under load.
• Copper conductors are THHN
insulated wire rated 90°C.
• Meets requirements of Article 604
of the National Electrical Code.
• Galvanized steel exterior with
integral keying for voltage and
amperage.
• MWS components assembled
with 12 AWG conductors rated at
20 amperes with full size ground
wire.
• Cable end supplied with 1/2"
connector with locknut and 6" prestripped leads.
• DC cable allows you to easily
supply power and control to other
system units.
• Valox 365 constructed contact
housings are approved for
environmental air plenums.
DC-5LT
DROP CABLE
Modular Wiring System
D IMENS IONA L D A TA
SYSTEM VIEW (not to scale)
5/8"
[16mm]
Side
Junction Box
or any Out of
System Unit
supplied by
others.
Drop Cable
Extender Cable
1-7/8"
[47mm]
Splitter or
Circuit T
Extender Cable
Drop Cable (DC)
Supplies power and control to system units.
4-3/8"
[112mm]
Top
Typical MWS Wiring System Application shown utilizing Drop
Cable (DC).
Consult MWS Installation, Application and Specification
Manual for additional comprehensive system information.
ORD ER ING INFOR M AT I O N
S A M P L E N U M B E R : 2 7 D C 1 2 /4 G 0 9 5 L T
MWS AUTOCAD DRAFTING
MWS offers AutoCAD drafting to layout
MWS, providing the contractor with
additional benefits.
DC
Component
DC=DropCable
Conductors and Size
12/4G=#12, 4 Conductors Plus Ground
Cable Length (Feet)
09=9'
15=15'
MWS design layout time is reduced.
Options
5LT
Bills of material are computer-generated
guaranteeing accuracy.
MWS drawing symbols and details
standardized.
Specifications & dimensions subject to change without notice. Consult your Cooper Lighting Representative
for availability and ordering information.
Layouts are available on CD or e-mail.
To utilize this service and for additional
information, contact the MWS Sales
Department (888) 487-4887.
SH IP P ING D A T A
Install dust covers on unused open ends.
Scale is exaggerated on fixtures and
MWS system applications.
Specifications and
dimensions subject to
change without notice.
YS
ER
TEM
S
Eaton’s Cooper Lighting Business
1121 Highway 74 South
Peachtree City, GA 30269
P: 770-486-4800
www.eaton.com/lighting
All electrical boxes, conduit, connections
and switches by others.
C
Eaton
1000 Eaton Boulevard
Cleveland, OH 44122
United States
Eaton.com
UnitStandard
Wt.Qty./Carton
3.0 lbs.
9
4.5 lbs.
8
S
Cable
Length
9’
15’
D
Voltage
12=120V
27=277V
TIFIE
PS510002EN
2015-04-06 13:31:07
Download