MWS D ES C R IPTION MWS-5LT, Modular Wiring Systems with DALI Control, provides low cost installation of both power for lighting and Class 1 control wiring for use with Fifth Light DALI systems. Using modular components that plug together, MWS-5LT can be installed in a fraction of the time of hardwiring both lighting and control. Plus, MWS-5LT offers the advantage of relocating fixtures and DALI control devices for future renovations. ® Type Catalog # Project Date Comments The MWS Drop Cable with DALI Control (DC-5LT) feeds power and control to wall or ceiling fixtures from a compatible Circuit T (CT) or Splitter (SP). See the CT or SP specification sheets for compatibility details. Prepared by MWS Drop cables may be plugged into the last fixture cable (FC) or from a Splitter (SP) anywhere within the system. D ES IGN FEA TUR ES • UL Listed under Standard 183 for make or break under load. • Copper conductors are THHN insulated wire rated 90°C. • Meets requirements of Article 604 of the National Electrical Code. • Galvanized steel exterior with integral keying for voltage and amperage. • MWS components assembled with 12 AWG conductors rated at 20 amperes with full size ground wire. • Cable end supplied with 1/2" connector with locknut and 6" prestripped leads. • DC cable allows you to easily supply power and control to other system units. • Valox 365 constructed contact housings are approved for environmental air plenums. DC-5LT DROP CABLE Modular Wiring System D IMENS IONA L D A TA SYSTEM VIEW (not to scale) 5/8" [16mm] Side Junction Box or any Out of System Unit supplied by others. Drop Cable Extender Cable 1-7/8" [47mm] Splitter or Circuit T Extender Cable Drop Cable (DC) Supplies power and control to system units. 4-3/8" [112mm] Top Typical MWS Wiring System Application shown utilizing Drop Cable (DC). Consult MWS Installation, Application and Specification Manual for additional comprehensive system information. ORD ER ING INFOR M AT I O N S A M P L E N U M B E R : 2 7 D C 1 2 /4 G 0 9 5 L T MWS AUTOCAD DRAFTING MWS offers AutoCAD drafting to layout MWS, providing the contractor with additional benefits. DC Component DC=DropCable Conductors and Size 12/4G=#12, 4 Conductors Plus Ground Cable Length (Feet) 09=9' 15=15' MWS design layout time is reduced. Options 5LT Bills of material are computer-generated guaranteeing accuracy. MWS drawing symbols and details standardized. Specifications & dimensions subject to change without notice. Consult your Cooper Lighting Representative for availability and ordering information. Layouts are available on CD or e-mail. To utilize this service and for additional information, contact the MWS Sales Department (888) 487-4887. SH IP P ING D A T A Install dust covers on unused open ends. Scale is exaggerated on fixtures and MWS system applications. Specifications and dimensions subject to change without notice. YS ER TEM S Eaton’s Cooper Lighting Business 1121 Highway 74 South Peachtree City, GA 30269 P: 770-486-4800 www.eaton.com/lighting All electrical boxes, conduit, connections and switches by others. C Eaton 1000 Eaton Boulevard Cleveland, OH 44122 United States Eaton.com UnitStandard Wt.Qty./Carton 3.0 lbs. 9 4.5 lbs. 8 S Cable Length 9’ 15’ D Voltage 12=120V 27=277V TIFIE PS510002EN 2015-04-06 13:31:07