MWS D ES C R IPTION MWS, Modular Wiring Systems, provide low cost installation of branch circuit wiring for lighting and power. Using modular components that plug together, MWS can be installed in a fraction of the time of hardwiring. Plus, MWS offers the advantage of relocating fixtures and outlets in future renovations. ® Type Catalog # Project Date Comments The MWS Drop Cable (DC) supplies power to out of system units that are wall mounted or ceiling mounted. Prepared by MWS Drop cables may be plugged into the last fixture cable (FC) or from a Splitter (SP) anywhere within the system. DES IGN FEA TUR ES • UL Listed under Standard 183 for make or break under load. • Copper conductors are THHN insulated wire rated 90°C. • Meets requirements of Article 604 of the National Electrical Code. • Galvanized steel exterior with integral keying for voltage and amperage. • MWS components assembled with 12 AWG/10 AWG conductors rated at 20 amperes with full size ground wire. • Cable end supplied with 1/2" connector with locknut and 6" prestripped leads. • DC cable allows you to easily supply power to other system units such as j-boxes, receptacles or fixtures. • Valox 365 constructed contact housings are approved for environmental air plenums. DC DIMENS IONA L D A TA DROP CABLE SYSTEM VIEW (not to scale) 5/8" [16mm] Side Drop Cable Extender Cable 1-7/8" [47mm] Splitter or Circuit T Modular Wiring System Junction Box or any Out of System Unit supplied by others. Extender Cable Drop Cable (DC) Supplies power to out of system units. (Fixtures, J-boxes, etc.). 4-3/8" [112mm] Top Typical MWS Wiring System Application shown utilizing Drop Cable (DC). Consult MWS Installation, Application and Specification Manual for additional comprehensive system information. OR D ER ING INFOR M AT I O N S A M P L E N U M B E R : 2 7 D C 1 2 /2 G 1 1 MWS AUTOCAD DRAFTING MWS offers AutoCAD drafting to layout MWS, providing the contractor with additional benefits. DC Component DC=DropCable Conductors and Size 10/2G=#10, 2 Conductors Plus Ground 10/3G=#10, 3 Conductors Plus Ground 10/4G=#10, 4 Conductors Plus Ground 12/2G=#12, 2 Conductors Plus Ground 12/3G=#12, 3 Conductors Plus Ground 12/4G=#12, 4 Conductors Plus Ground Cable Length (Feet) 05=5' 09=9' 11=11' 15=15' Options 2N=2 Neutral (1) MWS design layout time is reduced. Bills of material are computer-generated guaranteeing accuracy. MWS drawing symbols and details standardized. Layouts are available on CD or e-mail. To utilize this service and for additional information, contact the MWS Sales Department (888) 487-4887. NOTES: (1)12/4G and 10/4G only. Specifications & dimensions subject to change without notice. Consult your Cooper Lighting Representative for availability and ordering information. SH IP P ING D A T A All electrical boxes, conduit, connections and switches by others. Install dust covers on unused open ends. Scale is exaggerated on fixtures and MWS system applications. Specifications and dimensions subject to change without notice. YS ER TEM S Eaton’s Cooper Lighting Business 1121 Highway 74 South Peachtree City, GA 30269 P: 770-486-4800 www.cooperlighting.com Standard Qty./Carton 12 9 8 C Eaton 1000 Eaton Boulevard Cleveland, OH 44122 United States Eaton.com Unit Wt. 2.0 lbs. 3.0 lbs. 3.5 lbs. S Cable Length 5' 9' 11' D Voltage 12=120V 20=208V 24=240V 27=277V 34=347V 48=480V TIFIE ADF031851 2015-01-15 09:36:13