MWS

advertisement
MWS
D ES C R IPTION
MWS, Modular Wiring Systems, provide low cost installation of branch
circuit wiring for lighting and power. Using modular components
that plug together, MWS can be installed in a fraction of the time of
hardwiring. Plus, MWS offers the advantage of relocating fixtures and
outlets in future renovations.
®
Type
Catalog #
Project
Date
Comments
The MWS Fixture Fitting (FF) feeds power to any lighting fixture while
allowing the circuit to feed through to the next fixture. MWS Power
Fitting (PF) perform the same function but with 12 AWG leads.
Prepared by
MWS Switch Drops can be connected in front of a Fixture Fitting to
DES IGN FEA TUR ES
• UL Listed under Standard 183 for
make or break under load.
• Copper conductors with THHN
insulated wire rated at 90°C.
• Powers fixture and allows circuit
to feed through to next fixture.
• Meets requirements of Article 604
of the National Electrical Code.
• 6” pre-stripped FF leads are
18AWG TFN while PF leads are
12AWG TFN. All leads come with
pushwire connectors.
• Positive self-grounding locking
clip fits into any 1/2” KO on fixture.
• MWS components assembled
with 12 AWG/10 AWG conductors
rated at 20 amperes with full size
ground wire.
All unused outlets require a MWS
dust cover. MWS ST, S P, S D , C T
and TC are shipped with one dust
cover attached.
• Valox 365 constructed
contact housing approved for
environmental air plenums.
FF / PF
D IMENS IONA L D A TA
FIXTURE FITTING (FF)
POWER FITTING (PF)
SYSTEM VIEW (not to scale)
Extender
Cable
Fixture
Fitting
Extender
Cable
Modular Wiring System
Side
Quick
Connect
Fixture Fitting (FF)
Feeds power to fixture and allows
circuits to be carried through to other
fixture. Locks into 1/2" KO of access
plate, fixture body or J-box. The FF
adds only 7/8" to overall height of the
fixture.
2-1/4"
[57mm]
Typical MWS Wiring System
Application shown utilizing (FF).
5-5/16"
[136mm]
Consult MWS Installation, Application
and Specification Manual for
additional comprehensive system
information.
Top
MWS AUTOCAD DRAFTING
MWS offers AutoCAD drafting to layout
MWS, providing the contractor with
additional benefits.
ORD ER ING INFOR M AT I O N
S A M P L E N U M B E R : 2 7 F F 1 2 /2 G
MWS design layout time is reduced.
Bills of material are computer-generated
guaranteeing accuracy.
FF
Voltage
12=120V
20=208V
24=240V
27=277V
34=347V
48=480V
Component
FF=Fixture Fitting
PF=Power Fitting
Conductors and Size
10/2G=#10, 2 Conductors Plus Ground
10/3G=#10, 3 Conductors Plus Ground
10/4G=#10, 4 Conductors Plus Ground
12/2G=#12, 2 Conductors Plus Ground
12/3G=#12, 3 Conductors Plus Ground
12/4G=#12, 4 Conductors Plus Ground
MWS drawing symbols and details
standardized.
Options
2N=2 Neutral (1)
Layouts are available on CD or e-mail.
To utilize this service and for additional
information, contact the MWS Sales
Department (888) 487-4887.
NOTES: (1) 12/4G and 10/4G only.
Specifications & dimensions subject to change without notice. Consult your Cooper Lighting Representative
for availability and ordering information.
SH IP P ING D A T A
Specifications and
dimensions subject to
change without notice.
YS
ER
TEM
S
Eaton’s Cooper Lighting Business
1121 Highway 74 South
Peachtree City, GA 30269
P: 770-486-4800
www.cooperlighting.com
Scale is exaggerated on fixtures and
MWS system applications.
C
Eaton
1000 Eaton Boulevard
Cleveland, OH 44122
United States
Eaton.com
Install dust covers on unused open ends.
S
UnitStandard
Wt.Qty./Carton
1 lb.
32
All electrical boxes, conduit, connections
and switches by others.
D
Front
TIFIE
ADF031843
2015-01-15 10:41:22