MWS

advertisement
MWS
D ES C R IPTION
MWS, Modular Wiring Systems, provide low cost installation of branch
circuit wiring for lighting and power. Using modular components
that plug together, MWS can be installed in a fraction of the time of
hardwiring. Plus, MWS offers the advantage of relocating fixtures and
outlets in future renovations.
The MWS Fixture Cable (FC) continues power from the Starter or switch
drop to the first lighting fixture and between lighting fixtures. The line
side connector snaps into any 1/2" knockout and has 6" #18 leads to
connect to fixture wiring.
®
Type
Catalog #
Project
Date
Comments
Prepared by
Add length to MWS Fixture Cables with an Extender Cable.
DES IGN FEA TUR ES
• UL Listed under Standard 183 for
make or break under load.
• Meets requirements of Article 604
of the National Electrical Code.
• MWS components assembled
with 12 AWG/10 AWG conductors
rated at 20 amperes with full size
ground wire.
• THHN insulated conductors rated
at 90°C with 16AWG solid TFN
fixture leads. All leads come with
pushwire connectors
• Galvanized steel exterior with
integral keying for voltage and
amperage.
• Positive self-grounding locking
clip fits into any 1/2” KO on fixture.
• Unique double-blade contact
ensures proper mating of electrical
components to prevent pushback
or pullout.
All unused outlets require a MWS
dust cover. MWS ST, S P, S D , C T
and TC are shipped with one dust
cover attached.
• Valox 365 constructed
contact housing approved for
environmental air plenums.
FC
FIXTURE CABLE
DIMENS IONA L D A TA
Modular Wiring System
1-7/8"
[47mm]
Front
4-3/8" [112mm]
Front
4-3/8" [112mm]
Top
5/8"
[16mm]
Side
3/4"
[19mm]
SYSTEM VIEW (not to scale)
Fixture Cable
Fixture Cable (FC)
Feeds power to fixtures and allows
circuits to be carried through to
other fixtures. Locks into 1/2" KO of
access plate, fixture body or J-box.
The unit adds 7/8" to overall height
of the fixture.
Quick
Connect
MWS AUTOCAD DRAFTING
MWS offers AutoCAD drafting to layout
MWS, providing the contractor with
additional benefits.
MWS design layout time is reduced.
Bills of material are computer-generated
guaranteeing accuracy.
Typical MWS Wiring System
Application shown utilizing Fixture
Cable (FC).
MWS drawing symbols and details
standardized.
Consult MWS Installation,
Application and Specification
Manual for additional comprehensive system information.
To utilize this service and for additional
information, contact the MWS Sales
Department (888) 487-4887.
Layouts are available on CD or e-mail.
All electrical boxes, conduit, connections
and switches by others.
Install dust covers on unused open ends.
Scale is exaggerated on fixtures and
MWS system applications.
C
ER
TEM
S
YS
D
Fixture Cable
S
Fixture Cable
TIFIE
ADF031841
2015-01-15 10:26:14
MWS FC
ORDER ING INFOR M A TION
SA MP L E NUMB E R : 2 7 F C 1 2 /3 G 1 1
FC
Voltage
12=120V
27=277V
34=347V
Component
FC=Fixture Cable
Conductors and Size
12/2G=#12, 2 Conductors Plus Ground
12/3G=#12, 3 Conductors Plus Ground
12/4G=#12, 4 Conductors Plus Ground
Cable Length (Feet)
07=7'
09=9'
11=11'
13=13'
15=15'
17=17'
Options
2N=2 Neutral (1)
NOTES: (1)12/4G only.
Specifications & dimensions subject to change without notice. Consult your Cooper Lighting Representative for availability and ordering information.
SH IP P ING D A T A
Cable
Length
7'
9'
11'
13'
15'
17'
Eaton
1000 Eaton Boulevard
Cleveland, OH 44122
United States
Eaton.com
Eaton’s Cooper Lighting Business
1121 Highway 74 South
Peachtree City, GA 30269
P: 770-486-4800
www.cooperlighting.com
Specifications and
dimensions subject to
change without notice.
UnitStandard
Wt.Qty./Carton
2.5 lbs.
10
3.0 lbs.
9
3.5 lbs.
7
4.0 lbs.
6
4.5 lbs.
6
5.0 lbs.
5
ADF031841