MWS

advertisement
MWS
D ES C R IPTION
MWS-5LT, Modular Wiring Systems with DALI Control, provides low
cost installation of both power for lighting and Class 1 control wiring for
use with Fifth Light DALI systems. Using modular components that plug
together, MWS-5LT can be installed in a fraction of the time of hardwiring
both lighting and control. Plus, MWS-5LT offers the advantage of
relocating fixtures and DALI control devices for future renovations.
Catalog #
The MWS T Cable with DALI Control (TC-5LT) feeds power and control
wiring to wall or ceiling fixtures while feeding downstream to another
fixture. Compatible MWS Extender Cables (EC) are used connect either
end of the TC-5LT. See the Extender Cable specification sheet for compatible models.
Prepared by
®
Type
Project
Date
Comments
MWS Extender Cables feed power to each T Cable.
D ES IGN FEA TUR ES
• UL Listed under Standard 183 for
make or break under load.
• Copper conductors are THHN
insulated wire rated 90°C.
• Meets requirements of Article 604
of the National Electrical Code.
• Galvanized steel exterior with
integral keying for voltage and
amperage.
• MWS components assembled
with 12 AWG conductors rated at
20 amperes with full size ground
wire.
• Allows downstream feeding
of circuits to another electrical
component or fixture.
• Cable end supplied with 1/2”
connector with locknut and 6” pre-stripped leads.
• Valox 365 constructed contact
housings are approved for
environmental air plenums.
TC-5LT
All unused outlets require a MWS
dust cover. MWS ST, S P, S D , C T
and TC are shipped with one dust
cover attached.
T CABLE
Modular Wiring System
D IMENS IONA L D A TA
SYSTEM VIEW (not to scale)
Extender Cable
T Cable
Extender Cable
Side
2-1/4"
[57mm]
Front
5-5/16"
[136mm]
Top
ORD ER ING INFOR M AT I O N
MWS AUTOCAD DRAFTING
MWS offers AutoCAD drafting to layout
MWS, providing the contractor with
additional benefits.
S A M P L E N U M B E R : 2 7 T C 1 2 /4 G 0 9 5 L T
TC
Component
TC=T Cable
Conductors and Size
12/4G=#12, 4 Conductors Plus Ground
Bills of material are computer-generated
guaranteeing accuracy.
Options
5LT
Cable Length (Feet)
01=1'
09=9'
15=15'
MWS drawing symbols and details
standardized.
Layouts are available on CD or e-mail.
To utilize this service and for additional
information, contact the MWS Sales
Department (888) 487-4887.
Specifications & dimensions subject to change without notice. Consult your Cooper Lighting Representative
for availability and ordering information.
SH IP P ING D A T A
Install dust covers on unused open ends.
Scale is exaggerated on fixtures and
MWS system applications.
Specifications and
dimensions subject to
change without notice.
YS
ER
TEM
S
Eaton’s Cooper Lighting Business
1121 Highway 74 South
Peachtree City, GA 30269
P: 770-486-4800
www.eaton.com/lighting
All electrical boxes, conduit, connections
and switches by others.
C
Eaton
1000 Eaton Boulevard
Cleveland, OH 44122
United States
Eaton.com
UnitStandard
Wt.Qty./Carton
1.0 lbs.
12
3.5 lbs.
8
5.0 lbs.
6
S
Cable
Length
1’
9’
15’
D
Voltage
12=120V
27=277V
MWS design layout time is reduced.
TIFIE
PS510004EN
2015-04-06 13:41:56
Download