MWS D ES C R IPTION MWS-5LT, Modular Wiring Systems with DALI Control, provides low cost installation of both power for lighting and Class 1 control wiring for use with Fifth Light DALI systems. Using modular components that plug together, MWS-5LT can be installed in a fraction of the time of hardwiring both lighting and control. Plus, MWS-5LT offers the advantage of relocating fixtures and DALI control devices for future renovations. Catalog # The MWS T Cable with DALI Control (TC-5LT) feeds power and control wiring to wall or ceiling fixtures while feeding downstream to another fixture. Compatible MWS Extender Cables (EC) are used connect either end of the TC-5LT. See the Extender Cable specification sheet for compatible models. Prepared by ® Type Project Date Comments MWS Extender Cables feed power to each T Cable. D ES IGN FEA TUR ES • UL Listed under Standard 183 for make or break under load. • Copper conductors are THHN insulated wire rated 90°C. • Meets requirements of Article 604 of the National Electrical Code. • Galvanized steel exterior with integral keying for voltage and amperage. • MWS components assembled with 12 AWG conductors rated at 20 amperes with full size ground wire. • Allows downstream feeding of circuits to another electrical component or fixture. • Cable end supplied with 1/2” connector with locknut and 6” pre-stripped leads. • Valox 365 constructed contact housings are approved for environmental air plenums. TC-5LT All unused outlets require a MWS dust cover. MWS ST, S P, S D , C T and TC are shipped with one dust cover attached. T CABLE Modular Wiring System D IMENS IONA L D A TA SYSTEM VIEW (not to scale) Extender Cable T Cable Extender Cable Side 2-1/4" [57mm] Front 5-5/16" [136mm] Top ORD ER ING INFOR M AT I O N MWS AUTOCAD DRAFTING MWS offers AutoCAD drafting to layout MWS, providing the contractor with additional benefits. S A M P L E N U M B E R : 2 7 T C 1 2 /4 G 0 9 5 L T TC Component TC=T Cable Conductors and Size 12/4G=#12, 4 Conductors Plus Ground Bills of material are computer-generated guaranteeing accuracy. Options 5LT Cable Length (Feet) 01=1' 09=9' 15=15' MWS drawing symbols and details standardized. Layouts are available on CD or e-mail. To utilize this service and for additional information, contact the MWS Sales Department (888) 487-4887. Specifications & dimensions subject to change without notice. Consult your Cooper Lighting Representative for availability and ordering information. SH IP P ING D A T A Install dust covers on unused open ends. Scale is exaggerated on fixtures and MWS system applications. Specifications and dimensions subject to change without notice. YS ER TEM S Eaton’s Cooper Lighting Business 1121 Highway 74 South Peachtree City, GA 30269 P: 770-486-4800 www.eaton.com/lighting All electrical boxes, conduit, connections and switches by others. C Eaton 1000 Eaton Boulevard Cleveland, OH 44122 United States Eaton.com UnitStandard Wt.Qty./Carton 1.0 lbs. 12 3.5 lbs. 8 5.0 lbs. 6 S Cable Length 1’ 9’ 15’ D Voltage 12=120V 27=277V MWS design layout time is reduced. TIFIE PS510004EN 2015-04-06 13:41:56