MWS D ES C R IPTION MWS, Modular Wiring Systems, provide low cost installation of branch circuit wiring for lighting and power. Using modular components that plug together, MWS can be installed in a fraction of the time of hardwiring. Plus, MWS offers the advantage of relocating fixtures and outlets in future renovations. ® Type Catalog # Project Date Comments The MWS Switch Drop (SD) introduces local switching into the MWS circuit. Switch Drops may be installed during rough-in or renovations. MWS Extender Cables bring power from starters to the first Switch Drop and between consecutive Switch Drops. Prepared by Switch Drops can also be connected together for multiple switch locations. DES IGN FEA TUR ES • UL Listed under Standard 183 for make or break under load. • Copper conductors are THHN insulated wire rated 90°C. • Meets requirements of Article 604 of the National Electrical Code. • Galvanized steel exterior with integral keying for voltage and amperage. • MWS components assembled with 12 AWG/10 AWG conductors rated at 20 amperes with full size ground wire. • Cable end supplied with 1/2” connector with locknut and 6” prestripped leads. • Introduces single or multiple local switching into the MWS circuit. • Valox 365 constructed contact housings are approved for environmental air plenums. All unused outlets require a MWS dust cover. MWS ST, S P, S D , C T and TC are shipped with one dust cover attached. SD SWITCH DROP D IMENS IONA L D A TA Modular Wiring System SYSTEM VIEW (not to scale) Extender Cable Side 2-1/4" [57mm] Switch Drop Fixture Cable Fixture Cable 2-1/4" [57mm] 5-5/16" [136mm] 1-13/16" [45mm] Top Typical MWS Wiring System Application shown utilizing Switch Drop (SD). Consult MWS Installation, Application and Specification Manual for additional comprehensive system information. ORD ER ING INFOR M AT I O N MWS drawing symbols and details standardized. SD Layouts are available on CD or e-mail. Switching Function 3L=Single Circuit, Three Level DC=Dual Circuit, Dual Level DL=Single Circuit, Dual Level SL=Single Circuit, Single Level Cable Length (Feet) 01=1' 09=9' 15=15' SH IP P ING D A T A NOTES: (1)Available in #12 AWG only, rated at 20 amperes. Specifications & dimensions subject to change without notice. Consult your Cooper Lighting Representative for availability and ordering information. Cable Length 1' 9' 15' All electrical boxes, conduit, connections and switches by others. Install dust covers on unused open ends. Scale is exaggerated on fixtures and MWS system applications. Specifications and dimensions subject to change without notice. YS ER TEM S Eaton’s Cooper Lighting Business 1121 Highway 74 South Peachtree City, GA 30269 P: 770-486-4800 www.cooperlighting.com UnitStandard Wt.Qty./Carton 1.8 lbs. 15 3.6 lbs. 10 5.0 lbs. 6 To utilize this service and for additional information, contact the MWS Sales Department (888) 487-4887. C Eaton 1000 Eaton Boulevard Cleveland, OH 44122 United States Eaton.com Options N=Neutral Dropped to Switches S Component SD=Switch Drop (1) MWS design layout time is reduced. Bills of material are computer-generated guaranteeing accuracy. S A M P L E N U M B E R : 2 7 SD SL 0 9 Voltage 12=120V 27=277V 34=347V MWS AUTOCAD DRAFTING MWS offers AutoCAD drafting to layout MWS, providing the contractor with additional benefits. D Front Switch Drop (SD) Adds local line voltage switching. Switch Drop is attached directly to the switch junction box in the wall or to a junction box above the wall. Connect conductors to switches as required. TIFIE ADF031845 2015-01-15 10:56:15