Greengate Application Note Room Controller – Network Node Upgrade Safety Instructions Important Safeguards Read and Follow All Safety Instructions ●● Installation should be performed by a qualified electrician ●● Installation shall be in accordance with all applicable local and NEC codes ●● Turn the power off at circuit breakers before wiring ●● RC3DE models may contain circuits from more than one power source ●● Designed for indoor installation and use only ●● All new wiring must be fully verified before applying power ●● Servicing of equipment should be performed by qualified service personnel Save These Instructions System Overview Normal Power (Line In & Load Out) SPRC-R-20-120 (20A Receptacle Control) Line Voltage to J-Box Room Controller (Above Entry Door) Line Voltage to Receptacles (Low Voltage, Class 2) Emergency Power (Line In & Load Out) RC3DE Model only OCC-RJ45 0-10V Dimmer Wiring (Dimming Models Only) DSRC-FMOIR (Multi-zone Daylight Sensor) (Any Greengate Occupancy Sensor) Wallstation (Entry) Wallstation (Additional) RS-485 to other Room Controllers and ControlKeepers Network Node Installation Room Controller Firmware 1. Insert Netork Node. The Room Controller must be updated to the latest firmware version for the Network Node to work. Contact Eaton Lighting systems technical support at 1-800-553-3879 for information on updating Room Controller Firmware. 2. Install Cover. 3. Secure cover in place with two screws. 4. Install electrical connectors. Room Controller Networking This section applies to the RC3-PL-N, RC3D-PL-N and RC3DE-PL-N Room Controller models. 3 Room Controller Network Node The diagram below calls out some of the various Network Node components of the network node. 2 RS-485 Connection 1 Terminating Jumper Communication Status LEDs Reset Button Address DIP Switch Network Wiring Notes The Room Controller network is designed to communicate with other Room Controller and ControlKeeper network panels using a lighting control RS-485 network for communications. This allows the panels to share information and to be programmed from a central location using the Keeper Enterprise Software. Please refer to Table 1 for information on recommended network cables. 4 Acceptable Network Wiring Suggested Cable Eaton CAT# Standard RS485 Belden 9841 (Shield is not used) GG9841 Plenum RS485 Belden 89841 (Shield is not used) GG89841 Table 1. Network Wiring Recommendations For best network performance, one of the suggested cables should be used. If the specified cable is not used and communications problems occur that require troubleshooting assistance, additional charges for support may be assessed. 2 www.eaton.com/lightingsystems 1. All low voltage wiring is Class 2. To network Room Controllers together: 2. All low voltage wiring must enter the cabinet from the low voltage section of the enclosure. 1. Select end panels to establish the beginning and end of the network 3. All low voltage wiring must be run in separate conduit from line voltage wiring.Test all network wiring for shorts to AC ground before connecting to the Room Controller. 2. The end panels will have the network termination jumpers installed and the panels in between will have them removed. 4. If using Belden 9841 or 89841, ensure shields are taped back and not connected to any metal surfaces. 3. Wire the panels together per the diagram below. For clarity the network node is seen below. 5. Panels and devices on the RS-485 lighting network should be daisy-chained. Do not create a Star or T-Tapped configuration. End Panel Jumper installed Middle Panel(s) Jumper Removed 6. Total network length should not exceed 4000 feet. Network Wiring Detail The diagram below illustrates the networking of the Room Controllers. Pull the twisted pair wiring in conduit along the planned route, making certain that it is separated from any line voltage wiring. End Panel Jumper installed Room Controller Network Topology QuickConnect Coupler (GGRC-COUPLER) QuickConnect Cables 5 + Time Clock Blue Red Black 4 Integration Controls Slider Station + Alert Mode Brown 3 OCC-RJ45 (Occupancy Coupler) 2 1 Energy Options DIP Switch Occupancy 3 2 1 Not Used 4 Occ Default 10% Energy Options Demand Response Reset Vac (default) 20% 30% Dimmer 2 Dimmer 1 - Dimmer 3 + - Dimmer 2 + - Dimmer 1 + 0-10V Dimming Half Lights Full Lights All Off Blue - EM Line In Dimmer 2 Dimmer 1 - Dimmer 3 + Dimmer 2 + - Adjustable Skylights Adjustable Skylights + + QuickConnect Cables 5 - Black Brown 3 OCC-RJ45 (Occupancy Coupler) 2 1 Energy Options DIP Switch 1 20% Occupancy 2 Not Used 3 4 Occ Vac (default) Reset Demand Response Default 10% 30% 40% Status 0-10V Dimming Outputs + + + Dimmer 3 Dimmer 2 Occupancy/ Vacancy Sensor (OAWC-DT-120W) Dimmer 1 + 0-10V Dimming Blue Red 4 Dimmer 3 Dimmer 1 + Sensors Integration Controls Yellow - Load 1 Out Blue - Load In Red - Load 2 Out Purple - Load 3 Out Reset Status 0-10V Gain Adjustment 0-10V Dimming Outputs + + + Dimmer 3 Sensors Wallstations + Time Clock 0-10V Gain Adjustment 4 Vac (default) Receptacle BMS/Out Slider Station - + Alert Mode Energy Options Not Used 3 Occ 30% 40% Green A/V Mode Demand Response High End Occupancy 2 Energy Options 1 20% High End Energy Options DIP Switch Demand Response Default 10% Red Black Daylight sensor (DSRC-FMOIR) SPRC-R-20-120 20A Receptacle Control 6 Low End 1 Occupancy/ Vacancy Sensor (OAWC-DT-120W) Integration Controls 2 White/Black - 120V N White/Orange - 277V N Black Brown OCC-RJ45 (Occupancy Coupler) 3 Black - Line In Blue Red 4 Blue - EM Loads Out + 5 Integration Controls + Time Clock CAUTION: Bonding between conduit connections is not automatic and must be provided as part of the installation. Adjustable Skylights QuickConnect Cables Sensors Wallstations + + Alert Mode Low End Purple - Load 3 Out Adjustable Skylights Red - Load 2 Out Blue - Load In Receptacle BMS/Out Sensors Slider Station - A/V Mode Integration Controls Yellow - Load 1 Out White/Black - 120V N White/Orange - 277V N Black - Line In CAUTION: Bonding between conduit connections is not automatic and must be provided as part of the installation. Black Green Switchpack White Model: OCC-RJ45 Occupancy Sensor Coupler Blue - EM Line In Red Demand Response Daylight sensor (DSRC-FMOIR) SPRC-R-20-120 20A Receptacle Control 6 QuickConnect Coupler (GGRC-COUPLER) Model: OCC-RJ45 Occupancy Sensor Coupler Blue - EM Loads Out Switchpack Slider Station Wallstation QuickConnect Coupler (GGRC-COUPLER) White Occupancy/ Vacancy Sensor (OAWC-DT-120W) 0-10V Gain Adjustment Status Low End 40% Dimmer 3 Daylight sensor (DSRC-FMOIR) SPRC-R-20-120 20A Receptacle Control 6 High End Red - Load 2 Out Purple - Load 3 Out Adjustable Skylights Sensors Sensors Wallstations + -+ A/V Mode Demand Response Integration Controls Blue - Load In Yellow - Load 1 Out Black - Line In White/Black - 120V N White/Orange - 277V N Green Receptacle BMS/Out 0-10V Dimming Outputs + + + - Blue - EM Line In Blue - EM Loads Out The Ethernet Interface Module (EIM) and Wireless Ethernet Interface Module (WEIM) may be connected to any Lighting Control Panel in the system using the RS-232 cable included. (Part #:52-018703-00) Black CAUTION: Bonding between conduit connections is not automatic and must be provided as part of the installation. ControlKeeper TouchScreen Switchpack White Red Model: OCC-RJ45 Occupancy Sensor Coupler 120V Power Receptacle Required Adjustable Skylights EIM - Dimmer 2 + - Dimmer 1 + - 0-10V Dimming Half Lights Half Lights Full Lights Full Lights All Off Wallstation All Off Slider Station Wallstation Slider Station www.eaton.com/lightingsystems 3 Network Address Switch Detail After networking each panel an address will have to be assigned to each using the network address DIP Switch. The example below describes how to address the Room Controller. Each switch position (1–8) has a value associated with it (1–128). Addresses 1 through 254 are valid for use but 255 (all values added together) is reserved for system use and should not be used. 1. Add the value for each switch position that is On to obtain the panel address. Catalog Numbers RC3 RC3D RC3DE RC3-PL RC3D-PL RC3DE-PL RC3-PL-N RC3D-PL-N RC3DE-PL-N Switch Position ON OFF Value 1 + 4 = 5 (Panel Address) 2. Issue a soft reset by pressing the reset button to assign Network Node the address to the panel. RS-485 Connection Terminating Jumper Communication Status LEDs Reset Button Address DIP Switch Eaton 1000 Eaton Boulevard Cleveland, OH 44122 United States Eaton.com Eaton Lighting systems 203 Cooper Circle Peachtree City, GA www.eaton.com/lightingsystems © 2015 Eaton All Rights Reserved Printed in USA Publication No. AP503003EN June 1, 2015 Eaton is a registered trademark. All trademarks are property of their respective owners.