Building Consistency Meeting Old Business

advertisement
Building Consistency Meeting
Commercial
Date 08/03/2011 Recorder and minutes prepared by Kirk Aten/Lon McSwain
Staff present: On File
Public present: Wayne Carter (W B Carter Contracting); Keith Rhinehard (Optima
Engineering)
Topics/Subject
Decisions/Conclusions/Actions
Old
Business
None
New
Business
Section 1015.2
Exception 2
Section 1016.2
This exception also applies to the exiting from an occupied roof of a
fully sprinklered building.
If an ESFR sprinkler system is installed and the smoke and heat vents
are removed then the 400 foot travel distance does not apply.
Section 421
This section and the requirements of an R-3 out of the Building Code or
the Residential Code can be used to meet the requirements of these
occupancies.
No single piece of plastic shall be larger than 300 Sq. Ft. and separated
from other pieces of plastic by 4’-0” vertically and by at least a mullion
horizontally.
A toilet room is not required to be separated from a fire resistant
corridor if 1) the toilet is separated from the rest of the building by wall
constructed as corridor walls, 2) No other rooms open off the toilet
room, 3) Contains no gas or electrical appliances(except hand dryers) 4)
the toilet room is used for no other purpose than for which it was
designed.
A DVD on residential sprinklers was shown.
Section 2605.2
Item 3
Section 1017.5
Presentation
.
Approved By ___Lon McSwain_________ Date _______08/31/2011