LIEBERT® SITETPI-E V3 Product Specification/Installation Sheet Description The Liebert SiteTPI-E is an Ethernetready device intended to interface specifically to a SiteScan Web System. It is a 32-bit microprocessor-based device designed to monitor third-party equipment via an EIA-485/232 Modbus interface. Logically the device sits on the Ethernet network, providing the interface to SiteScan Web. This effectively creates a router/gateway and third-party interface in a single device. Screw terminal blocks are provided to terminate power, communication and input signal wiring. Module Dimensions and Layout 11.3" (287mm) Power connector 0.23" (5.8mm) Without Keypad Display: 24Vac, 24VA, 1A, 50-60 Hz 26Vdc, 10W, 0.4A 1" (25mm) Use Copper Conductors Only Class 2 Ground 3V Lithium Battery CR-123A Ethernet port Power On 100 LAN BACnet LINK SiteTPI-E BT485 ™ BT485 BACnet Rnet port R Port S2 88FO E143900 TYPE: 002001 Rnet Port S2 +12V EIA485 232 Net+ Tx Net- Port S1 Open Energy Management Equipment Gnd Rnet - Tx n/c DTR Rx n/c DCD n/c Rx - n/c Rx + DTR Net- Tx - Rx Net+ Tx + Tx DCD 2.75" (70mm) EIA-232 EIA-485 Error Codes: BACnet transmit BACnet receive Rx Archive Valid Port S1 transmit Port S1 receive Battery low Signal Gnd 7.5" (190.5mm) 2 wire 4 wire EIA-232 Signal Ground Local Access Rnet + 2.75" (70mm) Ext. Batt. Int. Batt. CONTROL MODULE Net + Net - Gnd +3V ® Shield Local access port Off External Battery Over ARCNET156 KBaud BACnet port 24V ac/dc 10/100 BaseT Ethernet Port E1 EIA-232 Chase = OK 0 = Download required 1 = Control Program Error Enhanced Access Port on S2 and Rnet IP Addr 2 = RAM full 3 = Comm setup error 4 = System error 8 = Formatting Module Status PTP on S2 Assigned +100 Enable Enable Off Default 0 Disable Disable 485-2w 485-4w Option Comm Blinking Dot = 'Run' EIA-485 Power LED BT485 MSTP on S1 Address On Format 1" (25mm) Module Address 10's 1's Made in USA Diagnostic LED indicators Port S1 1 Options comm Power Wiring Diagrams Enclosure Dimensions 14.25" (362mm) 12" (304.8mm) 1.13" (28.6mm) 3.35" (85mm) 3.92" (99.6mm) B 1.15" (29.3mm) 1.25" (31.8mm) 1.5" 1.5" (38.1mm) 1.5" (38.1mm) (38.1mm) 5.88" (149.2mm) 5.25" (133.4mm) 2.5" (63.5mm) 0.88" (22.2mm) DETAIL B 1.5" 1.5" (38.1mm) 1.5" (38.1mm) (38.1mm) 0.6" (15.1mm) 5.88" (149.2mm) 2 Enclosure Mounting The enclosure may be mounted on a wall or on the floor. Refer to the following diagrams for your application. Enclosure Wall Mounting Diagram 0.88" (22.2mm) 0.88" (22.2mm) 12.5" (317.5mm) 1" (25.4mm) 1" (25.4mm) A 11" (279.4mm) 11" (279.4mm) 1" (25.4mm) 1" (25.4mm) 0.88" (22.2mm) 12.5" (317.5mm) R 0.107" (2.71mm) 0.4" (10.2mm) DETAIL A 3 R 0.188" (4.76mm) 0.88" (22.2mm) Specifications Power 24VAC ±10%, 50 to 60Hz, 24VA, or 26VDC ±10%, 10W Module: Enclosure (charcoal): 11.3 x 0.56 x 7.5 (287 x 14.2 x 190.5) 14.25 x 2.85 x 12 (362 x 72.4 x 304.8) Dimensions W x D x H: in. (mm) • • • • • • • One (1) Ethernet 10/100BaseT RJ-45 port One (1) Configurable Serial Port - EIA-232 or 485 (2- or 4-wire) 5-position Terminal Block One (1) CMnet EIA-485 Port - Control Module network screw terminals Switch-selectable baud rates ARC156 / 9600 or 38.4bps Recommended wire: MAGNUM Cable P/N A3-ARC-156-2 BACnet Port (ARCNET156 or EIA-485 communication): In ARCNET156 mode, the port speaks BACnet ARC156. In EIA-485 mode, DIP switch settings specify baud rate and protocol: BACnet MS/TP or Modbus (RTU or ASCII). • Port S1 (BMS connection): Normally configured for a Building Management System; may be configured for EIA-485 or EIA-232. Supports BACnet MS/TP, BACnet PTP and Modbus (RTU or ASCII) protocols. • Port S2 (MFR connection): Connection to manufacturer’s equipment; jumper enables EIA-485 or EIA-232 mode. Supports BACnet MS/TP, BACnet PTP and Modbus (RTU or ASCII) protocols. • Rnet: Local laptop and/or BACview access port. Conforms to the BACnet Advanced Application Controller (B-AAC) Standard Device as defined in BACnet 135-2001 Annex L. 20°F to 140°F (-29°C to 60°C); 10 to 90% relative humidity, non-condensing. Note: Control modules should be installed within the building. 16 MByte non-volatile battery-backed SDRAM (with 12 MBytes available for use) 8 MByte Flash memory, 32-bit memory bus Built-in surge and transient protection circuitry 3V lithium battery P/N CR-123A; battery shelf life is 10 years with 720 hours of continuous operation Hardware watchdog timer UL916 (Canadian Std C22.2 No. 205-M1983), CE, FCC Part 15 - Subpart B - Class A Communication Environmental Operating Range Memory Protection Battery Fault Detection Agency Listings Diagnostic LEDs Indicator Description Indicator Description BACnet transmit BACnet receive Archive Valid Blinks when data is transmitted Blinks when data is received N/A Port S1 transmit Port S1 receive Battery low Blinks when data is transmitted Blinks when data is received Blinks when the battery is low Wiring Specifications Connection Ethernet 10 BaseT Port S1 ARCnet Port S2 EIA-485 Port S2 EIA-232 Supported Wire Types Maximum Wire Length Rating 328 ft. (100m) 3000 ft. (915m) N/A N/A 1000 ft. (300m) N/A 50 ft. (15m) N/A CAT 5 MAGNUM Cable P/N A3-ARC-156-2 18-22 AWG Stranded & Shielded; 18 AWG* (recommended) Non Plenum - Belden 9461; Plenum - Belden 88761 18-22 AWG Stranded & Shielded; 18 AWG* (recommended) Non Plenum - Belden 9461; Plenum - Belden 88761 Ordering Information Quantity Part # SiteTPI-E Description SiteScan Web Third-Party Interface Module - Ethernet Ready Liebert Corporation 1050 Dearborn Drive P.O. Box 29186 Columbus, OH 43229 Telephone: 1-800-877-9222 Facsimile: 1-614-841-6022 www.liebert.com © 2006 Liebert Corporation All rights reserved throughout the world. Specifications subject to change without notice. ® Liebert and the Liebert logo are registered trademarks of Liebert Corporation. All names referred to are trademarks or registered trademarks of their respective owners. SL-28105 (08/09) Rev. 2 4