SITELINK-E Product Specification/Installation Sheet Description The Liebert SiteLink-E is a product platform that comes in three models: SiteLink-12E, -4E and -2E. The models differ only in the number of Emerson family ports at the bottom of the module. SiteLink-12E SiteLink-E supports Emerson interfaces as a BACnet router that provides the communications link between Liebert units and other protocols and modules. The SiteLink-E is designed to communicate with Liebert equipment— environmental units, UPSs and Power Distribution Units—and route the information over a BACnet, Modbus or LONWorks™ network to a Building Automation System (BAS) workstation. Module Dimensions and Layout 11.3" (287mm) Diagnostic LED indicators Ethernet port ARCNET Transmit ARCNET Receive Module Status Error Codes LAN 24ac/26dc 8 = Formatting Power 3V Lithium Battery CR-123A 10's 1's Module Address LINK On Format Gnd +3V Over ARCNET156 KBaud 7.5" (190.5mm) BT485 ARCNET Shield Gnd Rnet + Rnet +12V Xnet + Xnet Gnd On Assigned +100 Enable Enable Off Default 0 Disable Disable Enhanced Access on Rnet IP Addr Address Ext. Batt. Int. Batt. PTP on S1 MSTP on S1 EIA-232 Net - EIA-485 Net + Rnet port BT485 Port S1 2 wire 4 wire EIA-232 Local Access Rnet Signal Ground Xnet Remote Expansion 485-4w 485-2w Xnet remote expansion port n/c Rx - n/c Rx + DTR Net- Tx - DCD Rx Net+ Tx + Tx 5.5" (139.7mm) SiteLink-12E Port 9-12 EIA-485 Net+, Net-, Net+Rx, Net-Rx Tx, Rx, Gnd, Gnd Net- Net+ Net-Rx Net+Rx Net- Port 12 Net-Rx Net+ Net+Rx Net- Port 11 Net-Rx Net+ Net+Rx Net- Net+ Port 10 Net-Rx Net+ Port 9 Net+Rx Port 8 Net- Port 7 Net+ Port 6 Net- Port 5 Net+ Net- Net- Port 4 Net+ Net- Port 3 Net+ Net- Port 2 Net+ Net+ Port 1 Net+ EIA-232 Net- Local access port Off External Battery ® Net- BACnet port BACnet 1" (25.4mm) Ground Battery low 2 = RAM full 3 = Comm setup error 4 = System error Blinking Dot = 'Run' 100 24Vac, 24VA, 1A, 50-60 Hz 26Vdc, 10W, 0.4A Archive Valid Port S1 Transmit Port S1 Receive Chase = OK 0 = Download required 1 = Control Program Error 10/100 BaseT Ethernet Port 0.23" (5.8mm) Power connector 1" (25.4mm) Port S1 1 Enclosure Mounting The enclosure may be mounted on a wall or on the floor. Refer to the following diagrams for your application. Enclosure Mounting Diagrams 0.88" (22.2mm) 0.88" (22.2mm) 12.5" (317.5mm) 1" (25.4mm) 1" (25.4mm) A 11" (279.4mm) 11" (279.4mm) 1" (25.4mm) 1" (25.4mm) 0.88" (22.2mm) 12.5" (317.5mm) R 0.107" (2.71mm) 0.4" (10.2mm) DETAIL A 2 R 0.188" (4.76mm) 0.88" (22.2mm) Enclosure Mounting Diagrams (continued) 14.25" (362mm) 12" (304.8mm) 1.13" (28.6mm) 3.35" (85mm) 3.92" (99.6mm) B 1.15" (29.3mm) 1.25" (31.8mm) 1.5" 1.5" (38.1mm) 1.5" (38.1mm) (38.1mm) 5.88" (149.2mm) 5.25" (133.4mm) 2.5" (63.5mm) 0.88" (22.2mm) DETAIL B 1.5" 1.5" (38.1mm) 1.5" (38.1mm) (38.1mm) 5.88" (149.2mm) 3 0.6" (15.1mm) Specifications Power 24VAC ±10%, 50 to 60Hz, 24VA, or 26VDC ±10%, 10W, 48VDC Dimensions Module: 11.3 x 0.56 x 7.5 (287 x 14.2 x 190.5) W x D x H: in. (mm) Enclosure (brushed aluminum): 14.25 x 2.85 x 12 (362 x 72.4 x 304.8) Communication Ports • Ethernet Port 10/100Base-T Fast Ethernet port. ARCNET156 or EIA-485 communication. In ARCNET156 mode, the port communicates via • ARC156 Port BACnet ARC156. EIA-232/422/485 configurable port for interaction with 3rd-party building automation systems • TPI Port S1 via software-selectable protocols. May also be configured for remote modem access. Each port can be individually set for different protocols & baud rates. • EIA-422/485 The number of ports varies by model: Ports 1-12 - for communication with SiteLink-2E (SSW-2E) SiteLink-4E (SSW-4E) SiteLink-12E (SSW-12E) equipment via • Ports 9-12 • Ports 1-12 • Ports 11-12 software-selectable Four of these 12 ports (9-12) These two ports include These four ports include protocols & baud an option for EIA-232 an option for EIA-232 include an option for EIA-232 rates connection. connection. connection. Environmental 20°F to 140°F (-29°C to 60°C); 10 to 90% relative humidity, non-condensing Operating Range Note: Control modules should be installed within the building. Memory Protection Battery Fault Detection Agency Listings 16 MByte non-volatile battery-backed SDRAM and 8 MByte Flash Built-in surge and transient protection circuitry - internal solid state polyswitches on incoming power and network communications connections 3V lithium battery P/N CR-123A; battery shelf life is 10 years with 720 hours of continuous operation Hardware watchdog timer UL, cUL, CE, FCC Wiring Specifications Connection Ethernet 10 BaseT BACnet Port Port S1 EIA-485 Port S1 EIA-232 Supported Wire Types Maximum Wire Length Rating CAT 5 MAGNUM Cable P/N A3-ARC-156-2 18-22 AWG Stranded & Shielded; 18 AWG (recommended) Non Plenum - Belden 9461; Plenum - Belden 88761 18-22 AWG Stranded & Shielded; 18 AWG (recommended) Non Plenum - Belden 9461; Plenum - Belden 88761 328 ft. (100m) 3000 ft. (915m) N/A N/A 1000 ft. (300m) N/A 50 ft. (15m) N/A Ordering Information Quantity Part # SSW-12E SSW-12EWO SSW-4E SSW-4EWO SSW-2E SSW-2EWO Description SiteLink-12E with enclosure - communicates with up to 12 Liebert unit controllers SiteLink-12E without enclosure - communicates with up to 12 Liebert unit controllers SiteLink-4E with enclosure - communicates with up to 4 Liebert unit controllers SiteLink-4E without enclosure - communicates with up to 4 Liebert unit controllers SiteLink-2E with enclosure - communicates with up to 2 Liebert unit controllers SiteLink-2E without enclosure - communicates with up to 2 Liebert unit controllers Liebert Corporation 1050 Dearborn Drive P.O. Box 29186 Columbus, OH 43229 Telephone: 1-800-877-9222 Facsimile: 1-614-841-6022 www.liebert.com © 2007 Liebert Corporation All rights reserved throughout the world. Specifications subject to change without notice. ® Liebert and the Liebert logo are registered trademarks of Liebert Corporation. All names referred to are trademarks or registered trademarks of their respective owners. SL-27218_REV0_01-07 4