Data Collection Methods for Categories of Emissions, Choice of Calculator, Data Requirements, and Objectives By Katie Masucci kmasucci@austincollege.edu This manual describes the methods used in collecting and entering the data required by the Clean Air Cool Planet Campus Carbon Calculator™, Version 6.9, for the FY 2012 (July 1, 2011 – June 30, 2012) greenhouse gas emissions inventory. The Clean Air Cool Planet’s (CACP) Campus Carbon Calculator™, Version 6.9, was used for the FY 2012 emissions inventory. The CACP Calculator is endorsed by the ACUPCC, and facilitates comparison with other campuses that have used it. The benefits of the CACP calculator include the ability of the user to enter categories of emissions in their original measurement units. For example, purchased electricity is entered in kWh, while natural gas is entered in MMBtu, etc. The calculator then converts these measures and others into their respective Global Warming Potentials (MT-eCO2), measurements of the extent to which a particular greenhouse gas (CO2, CH4, etc.) contributes to anthropogenic climate change. Once calculations are complete, the CACP calculator enables users to view all emissions by source as equivalent to CO2, CH4, or N2O in kg or MMBtu. Users may also choose to view all categories of emissions in metric tons of CO2 equivalent (MT-eCO2). This is so that all emissions can be aggregated and viewed as a single total amount instead of in measures of different greenhouse gases, each of which has a different global warming potential. The CACP calculator requires minimal input and no manual conversions; data are simply entered into a series of “Input” worksheets, and the calculator makes all the necessary conversions and calculations. Note that greenhouse gas inventories are not comprehensive; while they account for the major categories of the College’s emissions, it would be nearly impossible to track down each and every last emission in a given period of time. Though the calculator’s interface looks complex, its required data inputs are simple given Austin College’s infrastructure and small campus. A table at the end of this document shows the data that were entered into the calculator as well the staff member(s) who supplied the data. Some calculator inputs required more advanced procedures other than correspondence with a staff member(s). These procedures are explained below. Institutional Data Fiscal Year Full-Time Students Part-Time Students Residential Students FY 2011 FY 2012 FY 2013 1,306 1,338 1,253 8 15 7 N/A 1,030 N/A Summer School Students 100 106 58 With the exception of residential student information, these data were provided via the submission of a Data Request Form on the Registrar’s Office webpage. Gail Gentry of Institutional Research supplied the information via e-mail upon receipt of the Data Request Form. Michael Deen of Student Life provided residential student information. Note that all student data correspond to the fall semester of a given fiscal year; for example, the fall semester of 2011 was used for FY 2012 reporting purposes. Fiscal Year FY 2011 FY 2012 Full-Time Faculty 106 107 Part-Time Faculty 18 22 Full-Time Staff Part-Time Staff 182 178 4 8 The Human Resources Office provided all information regarding faculty and staff; Keith Larey supplied the data above via e-mail. Fiscal Year FY 2011 Operating Budget (Total Expenditures) $40,037,560 Energy Budget (Including Water) $1,889,254 Energy Budget (Excluding Water) $1,643,189 FY 2012 $39,966,810 $1,839,630 $1,529,047 Physical Size of Campus Buildings Physical Size of Research Space 803,474 Square Feet 803,474 Square Feet 21,000 Square Feet 21,000 Square Feet Sheryl Bradshaw of the Business Office provided all budget information via e-mail. Water expenditures are frequently included in energy budget reporting, however, the CACP calculator specifically requests that water expenditures not be included in energy budget reporting. Thus, Sheryl Bradshaw also included the value of the College’s water expenditures for FY 2011 and FY 2012 so that they could be deducted from the energy budget for reporting purposes. Heidi Ellis of the Business Office provided all endowment information via e-mail. Fiscal Year FY 2012 FY 2013 Austin College Endowment (Value at June 30 – FY End Date) $119,456,571 $124,800,382 John Jennings maintains a master spreadsheet of the physical size of all campus facilities. At the time that the FY 2012 report was completed (November, 2013 – January, 2014), the total campus size was: 974,054 square feet. This includes three facilities that officially came “online” in FY 2014: the IDEA Center (103,000 square feet), The Flats (31,480 square feet), and The Village (36,100 square feet). Thus the total campus size as reported for FY 2012 was: 803,474 square feet, which is equivalent to the current total at the time of publication minus the three new facilities. Note that Jennings’ master spreadsheet was revised in July, 2011, to reflect more upto-date and precise building information; thus, total campus size data reporting prior to FY 2012 (i.e. FY 2008 and FY 2010) may not have been accurate. The size of research space has remained consistent with previous reports; follow-up with Dr. Steve Goldsmith, Dean of Science Division, for future reports. Gasoline Fleet This section includes gasoline consumed by Physical Plant vehicles, Campus Police vehicles, Biology Dept. vans, and other College-owned vehicles. Methods of data collection for all of the above vehicles are as follows: - The College has a gasoline pump located at the Physical Plant that is used by Collegeowned vehicles operated by Physical Plant staff, Vice President Heidi Ellis, and the Athletics Dept. (they operate a “Gator” during outdoor athletics events). The Physical Plant’s FY 2012 purchased fuel log (gallons of unleaded and diesel fuel) was collected from the Physical Plant Office Manager, Linda Welch. While Ellis sometimes purchases fuel off-campus, she uses the College’s pump most often, according to the FY 2010 report. Fiscal Year FY 2012 - Gallons of Regular Gasoline 3,232.9 Gallons of Diesel 1,151.2 The FY 2012 purchased fuel log for the Campus Police Dept. was collected from Campus Police Office Coordinator, Becky Roberts, via e-mail. Becky Roberts wrote that the dramatic difference between the two periods was the trade of a Ford Explorer for a Ford Taurus, which is more efficient. Fiscal Year FY 2012 FY 2013 - Gallons of Regular Gasoline 248.081 67.754 Logbooks are kept in both vans owned and operated by the Biology Dept. These were used to calculate the total miles traveled in each van during FY 2012. Every time a van is used, a log entry is made, which consists of: Date, Driver Name, Destination/Reason for Travel, Beginning Odometer, End Odometer, Total Miles Traveled. Beginning with the first trip of FY 2012 and ending with the last trip in FY 2012, total miles traveled were summed for each van. Then, the website www.fueleconomy.gov was used to determine the combined estimated MPG of each van: o 1996 Dodge: 13 MPG Total Miles Traveled: 1,308 Miles Estimated Fuel Consumption: 100.615 Gallons o 1997 Ford: 14 MPG Total Miles Traveled: 3,785 Miles Estimated Fuel Consumption: 270.357 Gallons Finally, total miles traveled divided by fuel economy yielded the estimated total fuel purchase (gallons) for each van. Biology Dept. Support Associate, Caleb Smith, offered to keep track of all receipts for gas purchases for future reporting purposes. Thus, receipts can be used to simply sum gallons of gasoline purchased for the FY 2014 report and beyond. - For other College-owned vehicles (primarily those operated by Institutional Enrollment and Institutional Advancement personnel), mileage data were acquired from the Human Resources Office. Total miles traveled, total business miles, and total personal miles are accumulated on a calendar year-basis (Dec. 1 – Nov. 30). Thus, data for calendar years 2011 and 2012 were averaged, since both calendar years made up nearly equal parts of FY 2012: o Dec. 1, 2010 – Nov. 30, 2011 Total: 200,084 Miles Business: 122,070 Miles Personal: 78,014 Miles o Dec. 1, 2011 – Nov. 30, 2012 Total: 223,446 Miles Business: 136,323 Miles Personal: 87,123 Miles o Averages Used for FY 2012 Reporting Total: 211,765 Miles Business: 129,197 Miles Personal: 82,569 Miles In order to calculate total gallons of regular gasoline consumed by other College-owned vehicles, the average FY 2012 business miles value (129,197 miles) was divided by the average MPG of staff vehicles (21 MPG), as calculated via the commuting survey (see Commuting section below), which yielded an estimated value of gallons of regular gasoline consumed (6,152 gallons). Refrigerants, Chemicals, and Fertilizer Jade Rutledge (2009) determined that these emissions sources were de minimus, or insignificant to the campus’s total emissions; these sources accounted for 1% or less of the College’s total emissions during FY 2008. The ACUPCC does not require that such minimal categories be tallied for each consecutive inventory. However, since the data for FY 2010 and FY 2012 were readily available, new data were incorporated into both reports, which was beneficial; emissions from refrigerants and chemicals we found to account for more than 1% of the College’s total emissions for FY 2010 and FY 2012. Fiscal Year FY 2011 FY 2012 FY 2012 FY 2013 HFC-134a (lbs.) HFC-404a (lbs.) N/A 25 lbs., 14 Oz. 25.875 lbs. 28 lbs., 9 Oz. 12 lbs., 2 Oz. 15 lbs., 7 Oz. 15.4375 lbs. 9 lbs., 9 Oz. HCFC-22 (lbs.) 120 lbs., 15 Oz. 155 lbs., 13 Oz. 155.8125 lbs. 128 lbs., 13 Oz. HFC-410a (lbs.) N/A 25 lbs., 14 Oz. 25.875 lbs. 28 lbs., 9 Oz. Other N/A 11 lbs., 2 Oz. 11.125 lbs. 14 lbs., 3 Oz. The Physical Plant used two types of fertilizer during FY 2012: 10,000 lbs. of synthetic fertilizer at 28% nitrogen and 2,450 lbs. of synthetic fertilizer at 17% nitrogen. Liquid organic fertilizer had been used in addition to synthetic fertilizers during the previous reporting period, though none was used during FY 2012. The total amount (lbs.) of synthetic fertilizer was calculated, and as per Jade Rutledge’s (2009) protocol, a weighted average was taken to determine the average concentration of nitrogen for all of the synthetic fertilizer used during FY 2012: + 10,000 lbs. @ 28% N 2,450 lbs. @ 17% N 12,450 lbs. @ ?? % N Weighted Average: (10,000 (.28) + 2,450 (.17)) / 12,450 (2,800 + 416.5) / 12,450 0.25835341 0.258 12,450 lbs @ 25.8% N in FY 2012 Purchased Electricity, Purchased Natural Gas, and Custom Fuel Mix Total electricity consumption (all 14 campus meters) was obtained via Executive Director of Facilities, John Jennings: 12,934,735 kWh. Total natural gas consumption was also obtained via John Jennings: 45,379 MMBtu. Custom fuel mix considers the sources of a campus’s purchased electricity; as per the College’s contract with its electricity provider, 15% of the College’s purchased electricity is generated by renewable sources. This is accounted for in the Green Power Certificates entry, as the College purchases REC’s in addition to the 15% of purchased electricity in the contractual agreement. In order to report this accurately, 15% of total purchased electricity kWh was calculated (1,940,210 kWh) and added to the additional purchased REC’s (4,398,000 kWh); this sum was rounded to the nearest thousand, as REC’s are measured by megawatts rather than by kilowatts: 6,338,000 kWh of Green Power Certificates. In all, 49% of the College’s purchased electricity was offset with a combination of REC’s from the contractual agreement and the additional purchased REC’s (see Offsets and Renewable Energy Credits section below). Thus, renewable sources were not entered on the custom fuel mix input page (in order to avoid doublecounting). The custom fuel mix for FY 2012 was reported as follows. FY 2012 Purchased Electricity Generation Source Coal Natural Gas Nuclear % of Total 37.65% 50.59% 11.76% Entering a custom fuel mix is optional. Should an analyst choose to enter a custom fuel mix, their NERC region within the calculator must be selected; Texas’s eGRID sub region is called “ERCT.” Commuting The CACP calculator requires users to input various data regarding the commuting habits of students, faculty, and staff. These data are used to compute emissions (MT-eCO2) due to commuting. An online survey generated on www.surveymonkey.com was sent to students, faculty, and staff via e-mail. Respondents were asked several simple questions about their commuting habits, including the make, model, and year of vehicles regular commuters used to commute to and from campus. Responses were compiled, and the EPA Fuel Economy website, www.fueleconomy.gov, was used to identify the fuel efficiency of each regular commuter’s vehicle (that is, only those who answered “YES” to “Do you drive to campus on a REGULAR basis (3+ trips per week)?” The combined (city & highway) MPG of each vehicle was averaged for student, faculty, and staff vehicles, respectively. This portion of the survey response analysis was somewhat subjective in that MPG for each vehicle was referenced using limited information provided by survey respondents. For example, if a respondent did not provide a particular model (i.e. Honda vs. Honda Civic), or if a particular model listed multiple versions (i.e. manual vs. automatic, varied chassis sizes, etc.) the MPG for each version was averaged. - If multiple versions of a particular model were listed on www.fueleconomy.gov the vehicle was assumed to be automatic and to consume regular gasoline, unless noted by the respondent or only option(s) available. - Likewise, variable gear ratio/continuously variable transmission was not assumed unless noted by the respondent; however, if a manufacturer only produced a model with such features, they were assumed. - Four-cylinder engines were assumed for small-to-midsize vehicles, while 6 or 8-cylinder engines were assumed for trucks and SUV’s. - Vehicles listed with 2WD/FWD and 4WD/AWD options were assumed to be the 4WD/AWD variety. - Models with hybrid options were assumed not to be hybrids, unless specified by the respondent. - The assumptions above were made only when the respondent did not provide detailed vehicle information. - The website www.fueleconomy.gov does not list vehicles released prior to 1984. For respondents’ vehicles with model years prior to 1984, MPG estimates from the EPA’s 1984 database were recorded. - If the respondent did not provide the vehicle’s model year, the MPG for the 2013 model was recorded. This procedure was done in accordance with Jade Rutledge (2009) in which the author used vehicle data from the year 2009 in cases where respondents did not supply their vehicle’s model year. - If limited vehicle information was provided by a respondent (for example, only the model year), the MPG was not recorded and, thus, was left out of average MPG calculations. Based on FY 2012 data, the campus community, including students faculty, and staff, consisted of approximately 1,670 individuals. A request to complete the survey was sent to all members of the campus community. Based on information provided by 396 respondents, the following statistics were entered into the CACP calculator’s commuting worksheet for students, faculty, and staff, respectively: average automobile fuel efficiency (MPG), percent of people that used a personal vehicle to travel to campus, percent of people that carpooled, average trips per week, average weeks per year, and average miles per trip: - Students o Avg. MPG: 23 o % Commuters: 20% Yielded by dividing Total “YES” Commuters by Total Student Responses: 45 / 224 The calculator asks for the “total number of full-time equivalent (FTE) students who commute.” Note that part-time students equal ½ FTE, so: (20%) (Full Time Students + ½ (Part-Time Students)) (.20) (1,338 + (.50) (15)) (.20) (1,338 + 7.5) = 269 FTE Students Commute o % Carpoolers: 8% Yielded by dividing Total “YES” Commuters who are also “YES” Carpoolers by Total Student Responses: 18 / 224 o Avg. Round-Trips Per Week: 8 The survey asks respondents to record their typical round-trips per week, though the calculator asks for the average number of one-way trips per week; thus, the average round-trips figure was multiplied by 2, which yields 16 one-way trips per week. o Avg. Weeks Per Year: 29 o Avg. Miles Per One-Way Trip: 4.94 - Faculty o Avg. MPG: 27 o % Commuters: 83% Yielded by dividing Total “YES” Commuters by Total Faculty Responses: 64 / 77 The calculator asks for the “total number of full-time equivalent (FTE) faculty who commute.” Note that part-time faculty equal ½ FTE, so: (83%) (Full Time Faculty + ½ (Part-Time Faculty)) (.83) (107 + (.50) (22)) (.83) (107 + 11) = 98 FTE Faculty Commute o % Carpoolers: 13% Yielded by dividing Total “YES” Commuters who are also “YES” Carpoolers by Total Faculty Responses: 10 / 77 o Avg. Round-Trips Per Week: 6 The survey asks respondents to record their typical round-trips per week, though the calculator asks for the average number of one-way trips per week; thus, the average round-trips figure was multiplied by 2, which yields 12 one-way trips per week. o Avg. Weeks Per Year: 40 o Avg. Miles Per One-Way Trip: 12.36 - Staff o Avg. MPG: 21 o % Commuters: 89% Yielded by dividing Total “YES” Commuters by Total Staff Responses: 85 / 95 The calculator asks for the “total number of full-time equivalent (FTE) staff who commute.” Note that part-time staff equal ½ FTE, so: (89%) (Full Time Staff + ½ (Part-Time Staff)) (.89) (178 + (.50) (8)) (.89) (178 + 4) = 162 FTE Staff Commute o % Carpoolers: 8% Yielded by dividing Total “YES” Commuters who are also “YES” Carpoolers by Total Staff Responses: 8 / 95 o Avg. Round-Trips Per Week: 6 The survey asks respondents to record their typical round-trips per week, though the calculator asks for the average number of one-way trips per week; thus, the average round-trips figure was multiplied by 2, which yields 12 one-way trips per week. o Avg. Weeks Per Year: 46 o Avg. Miles Per One-Way Trip: 10.77 Based on FY 2012 data, the following is a summary of survey responses including full-time and part-time students, faculty, and staff: - Students: 224 Responses/1,353 Total = 17% of Students Responded - Faculty: 77 Responses/129 Total = 60% of Faculty Responded - Staff: 95 Responses/186 Staff = 51% of Staff Responded - Total: 396 Responses/1,668 Total = 24% of Campus Community Responded Directly Financed Outsourced Travel The air travel category in this section of the input worksheet is split into faculty/staff air miles and student air miles. Graduate Assistant Cassie Ensminger, MAT `13, collected all air travel data for FY 2012. - According to VP of Business Affairs Heidi Ellis, faculty/staff air travel data are not easy to pull and/or tally from College records; a new tracking system is necessary. Ellis suggested that all VP’s be given a form that allows them to easily record air travel information (dates, destination(s), airports used, etc.) for faculty/staff within their respective departments. Ellis suggested that the completion of such a form be mandated by President Hass. As of the completion of this report, no such form had been completed but would be in-time for the upcoming FY 2014 report. In the meantime, the value of faculty/staff air miles reported for FY 2010, which was also largely based on estimation, was used (see Katie Masucci (2011) for methods): 907,457 miles (Value A). - Student and staff air miles accrued for athletics events were provided by Cindy Mahana, former Athletics Office Coordinator, who was later succeeded by Julie Travis. Directly financed student air miles consist only of flights taken by athletic teams. Fiscal Year FY 2012 - Sum of Miles Traveled 11,430 Miles x Student Participants 338,636 Miles x Staff Participants 46,878 (Value B) Based on the data above, total faculty/staff directly financed outsourced travel is equal to the sum of Values A and B: 954,335 miles. Bus Travel Because this emissions source was determined to be de minimus by Jade Rutledge (2009), FY 2008 bus travel data were used for the FY 2010 and FY 2012 inventories: 24,868 miles. Personal Mileage Reimbursement Likewise, Jade Rutledge (2009) determined that this emissions source was de minimus, or largely insignificant in terms of the campus’s total emissions. However, since the data for FY 2010 were readily available, they were incorporated into the FY 2010 inventory. According to VP of Business Affairs Heidi Ellis, these data are not easy to pull and/or tally from College records; a new tracking system is necessary. Data on reimbursement for work-related travel in personal vehicles were not available for the FY 2012 inventory; thus data from FY 2010 were used: 97,694 miles. Should future analysts pursue up-to-date data, they’ll need to consider two values: 1) when employees are reimbursed for miles and 2) when employees are reimbursed for fuel purchases. Somehow, these two values – a value of miles and a value of dollars or gallons, respectively – will have to be summed. Study Abroad Air Travel As noted, Graduate Assistant Cassie Ensminger, MAT `13, collected all air travel data for FY 2012. - Ashlee Flinn and Valerie Roberts of the Center for Global Learning provided lists of students who studied abroad and their respective destinations for FY 2012 (Summer 2011, Fall 2011, Spring 2012, and Summer 2012). The website www.terrapass.com was used to calculate mileage from DFW International Airport to each student’s destination. If only a destination nation was provided, the nation’s capital city was assumed as the student’s destination (with the exception of Australia, for which Sydney was used twice – see Summer 2011 and Summer 2012). For Summer 2011 and Summer 2012, mileage was calculated for one-way trips only (unless otherwise noted), as only the departure or return flight typically fell within FY 2012. - Ashlee Flinn also provided a spreadsheet of all off-campus January Term 2012 travel courses. A similar protocol as that used to calculate total study abroad miles was used to calculate total January Term 2010 miles. From the spreadsheet, round-trip miles to the destination city/cities were multiplied by the number of travelers (students + faculty + alumni) who participated in each trip. - Similarly, January Term 2012 CSOC and “Other” FY 2012 CSOC course miles were added. A separate spreadsheet was obtained from Christina Robertson, Administrative Assistant of Student Services/Student Affairs, which listed the destinations of students who participated in CSOC courses. - Finally, Viki Reeder, Assistant Director of Career Services and Internship Coordinator, provided a spreadsheet of travel information concerning FY 2012 GO (Global Outreach) Fellows. Below is a summary table of all Study Abroad miles traveled. Program Miles Traveled Summer 2011 Study Abroad 59,187 Fall 2011 Study Abroad 369,522 Spring 2012 Study Abroad 450,389 Summer 2012 Study Abroad 29,325 January Term 2012 Travel Courses 1,930,894 January Term 2012 CSOC 57,264 "Other" FY 2012 CSOC 49,507 GO Fellows FY 2012 94,368 Total Study Abroad Miles for FY 2012 3,040,456 Solid Waste The solid waste calculations included assumptions made when estimating weight. Trash quantities were calculated from averages, since there are no meters on the equipment to measure the actual tons of waste. Thus, an average weight of 90 lbs. per cubic yard of un-compacted solid waste and 300 lbs. of solid waste per cubic yard of compacted waste was used to calculate trash based on the size of our receptacles and the frequency of pickup (CURC Campus Refuse Profile, 1997: http://recyclemaniacs.org/sites/default/files/documents/Volume-weight-conversions.pdf); note that this is the same source from which Jade Rutledge (2009) pulled a conversion factor from volume to weight of solid waste. The fullness of the receptacles is not known in detail; calculations are based on information provided by John Jennings, who said that receptacles are full 95% of the time. A sensitivity test was performed to determine the extent that the results differ depending on the fullness of the receptacles. The 100% full figure was used in the final calculations: a conservative overestimate considering Jennings’ statement. Containers of Landfill-Bound Waste Container Size (Cubic Yards) Pick-Up Frequency (# / Week) Estimated Pick-Ups / Year Flats - 916 E. Brockett 8 3 156 Bryan Apts. - 1114 E. Brockett 6 3 156 Physical Plant - 603 N. Porter 30 1* 52 Physical Plant - 603 N. Porter *Compactor* 30 1* 52 WCC - 1301 E. Brockett 4 6 312 WCC - 1301 E. Brockett 4 6 312 Cubic Yards / Year Conversion Factors* Tons / Year Flats - 916 E. Brockett 1248 Uncompacted: 90 Lbs. / CY 56.16 Bryan Apts. - 1114 E. Brockett 936 Uncompacted: 90 Lbs. / CY 42.12 Physical Plant - 603 N. Porter 1560 Uncompacted: 90 Lbs. / CY 70.20 Physical Plant - 603 N. Porter *Compactor* 1560 Compacted: 300 Lbs. / CY 234.00 WCC - 1301 E. Brockett 1248 Uncompacted: 90 Lbs. / CY 56.16 WCC - 1301 E. Brockett 1248 Uncompacted: 90 Lbs. / CY 56.16 Notes Total Estimated Tons MSW / Year 514.80 1* - Pick-Ups occur "on-call," however, 100 % Full Linda Welch estimated that pick-ups Total Estimated Tons MSW / Year actually occur once per week. 90 % Full Conversion Factors* - These are found in Total Estimated Tons MSW / Year CURC's Campus Refuse Profile, 1997. 80 % Full Containers of Landfill-Bound Waste 463.32 411.84 As noted by Jade Rutledge (2009), the methane gas (CH4) associated with landfilled waste from Austin College (and other landfill users) is not recovered at the landfill site. Thus, the measure of landfilled solid waste is entered into the calculator under the column titled, “No CH4 recovery.” Wastewater This emissions source was determined to be de minimus by Jade Rutledge (2009); it was not re-calculated for the FY 2010 report. However, it was re-calculated for the FY 2012 report due to new data available via John Jennings. In FY 2012, the College purchased 1,923,990 gallons for domestic use as well as 1,897,200 gallons for irrigation use. Since the latter is used on grounds and, thus, typically evaporates, it was not counted as “wastewater” for reporting purposes; only water purchased for domestic use, which ultimately goes to the city treatment facility, was counted as “wastewater” for reporting purposes. Paper According to Purchasing Representative Debra Reed, the College purchased 400 cases of uncoated freesheet paper during FY 2012; each case weighs 52 lbs. The paper is composed of 20% post-consumer waste. Because there is no input column for 20% post-consumer waste in the calculator, the paper data were entered in the following manner: 80% at “0% recycled” and 20% at “100% recycled.” - 400 Cases @ 52 lbs. Each = 20,800 lbs. Total - 80% of that is 16,640 lbs. – Enter as “0% Recycled” - 20% of that is 4,160 lbs. – Enter as “100% Recycled” Offsets and Renewable Energy Credits The College purchased retail offsets for January Term air travel and renewable energy credits for the college’s purchased electricity during FY 2012. Offsets were purchased for the air travel of one international January Term 2012 course (23 participants of Dede Hosek’s class paid $25 each for flights to and from Paris, France, with a round-trip mileage of 9,866 miles). In order to incorporate the purchase of these offsets into the emissions calculator, the total air miles traveled by all paid participants of the course were calculated (23 x 9,866 = 226,918 miles offset). These air miles (and nothing else, except alterations to the calculator) were entered into the “Study Abroad Air Miles” column of the calculator’s “Input” page in order to determine the total MT-eCO2 that the offset air miles accounted for (56.9 MT-eCO2). Then, the measure of offset MT-eCO2 was entered into the “Offsets with Additionality” section of the “Input” page under the column “Retail Offsets (High End).” Note that a clear definition of “high end” vs. “low end” retail offsets was not found; the calculator yielded the same results when MT-eCO2 of offsets were entered into either “high end” or “low end” retail offsets. Thus, January Term air travel offsets were entered in the “high end” category. REC's must be accounted for from two sources. 1) The College’s long-term electricity contract includes RECs for 15% of its electricity consumption, and 2) the College buys additional RECs to reach its annual target for electricity from green sources. Of the 6,338,000 kWh of total REC’s, 15% were included with the electricity contract and 34% were purchased separately. Effectively, 49% of total purchased electricity was mitigated through the purchase of REC’s. The College specifies 100% wind power REC’s for the additional REC purchase but has less control over the REC’s included with the electricity contract. Prior to this report, analysts effectively entered the 15% included in the energy contract as 15% of the energy the College was supplied having been generated by renewable sources (on the Custom Fuel Mix Input page). For this report, all of the REC’s were entered into the calculator as REC’s (in the “Green Power Certificates” column) as opposed to the previous procedure. The REC vendor for the additional 34% was 3Degrees, and the Renewable Energy Certificate Product Content Label lists "National" as the "Generation Location." These are U.S. Wind Power REC's; the Applicable Standard is "Green-e Energy National Standard Version 2.2." If exact sources of the REC’s for the contractual 15% renewable energy can be determined, this document will be updated appropriately. It’s assumed that the REC’s included in the electricity contract are Green-e-certified; this, too, will be confirmed if possible. Alterations to the CACP Calculator Three alterations were made to the calculator, as per Jade Rutledge’s (2009) procedure. First, student, faculty, and staff personal vehicle mileage averages, which are given in the calculator based on national vehicle mpg averages, were changed to represent the actual fuel efficiency of the cars used by members of the campus community. Second, because study abroad flights are largely international, the emissions calculator’s coefficient for the kilograms of CO2 per mile of air travel was multiplied by 0.64 to reflect the lower emissions per mile for longer, international flights, as opposed to higher emissions per mile for shorter, domestic flights. Since takeoff and landing cause the highest amount of emissions per mile traveled, it was assumed that longer flights yield fewer emissions: the longer the flight the smaller the proportion of emissions used in takeoff and landing. Thus, long flights use fewer emissions proportionally during takeoff and landing than shorter flights. When the calculator determines air travel emissions, it assumes short, domestic flights. Multiplying this coefficient by 0.64, according to DEFRA (2008), corrects for this difference in efficiency of domestic and international flights. This alteration applies only to study abroad flights; it was assumed that all directly financed air travel flights were domestic, and the efficiency of these flights was not adjusted. Third, a radiative forcing index (RFI) is used in the calculator to account for the cirrus clouds that form from the exhaust emitted by airplanes. Radiative forcing is any change in the balance between radiation coming into the atmosphere and radiation going out. Positive radiative forcing warms the surface of the earth, and negative radiative forcing cools it (Imperial College, 2005). According to Dr. David Baker (2011), these clouds can increase the earth’s average surface temperature, contributing to global climate change. The default RFI for air travel in the calculator is 2.7, which reflects 1992 IPCC measurements; another IPCC study indicated an RFI of 1. Because various sources indicate that radiative forcing data are inconclusive, an estimated RFI of 2 was used in the calculator based on the data available; this procedure is consistent with procedures for the FY 2008 and FY 2010 inventories. If more conclusive data are released in the near future, the RFI used in the calculator can be altered once again for specificity. Summary of Emissions Data Emissions Source MT-eCO2 % of Total On-Campus Stationary (Natural Gas) 2413.41 22.66% Direct Transportation (Fleet Vehicles) 102.92 0.97% Refrigerants/Chemicals 182.54 1.71% Agriculture (Fertilizer Application) 13.47 0.13% Purchased Electricity 6967.36 65.41% Faculty/Staff Commuting 583.69 5.48% Student Commuting 234.13 2.20% Directly Financed Air Travel 505.11 4.74% Other Directly Financed (Personal Mileage Reimbursement/Bus Miles) 46.70 0.44% Study Abroad Air Travel 762.27 7.16% Solid Waste 1595.88 14.98% Wastewater 0.93 0.01% Paper Purchasing 25.93 0.24% Scope 2 T & D Losses 689.08 6.47% Offsets (Additional) -56.90 -0.53% Offsets (Non-Additional) -3413.99 -32.05% Net Emissions (Subtract Offsets) 10652.52 100% Emissions Category MT-eCO2 % of Total Total Scope 1 2712.33 19.20% Total Scope 2 6967.36 49.33% Total Scope 3 4443.72 31.46% Total Emissions 14123.41 Net Emissions (Subtract Offsets) 10652.52 100% Emissions sources highlighted in green were determined to be de minimus, as they accounted for less than 1% of net emissions. CACP Calculator Input Data and Sources of Data Institutional Data Budgets Operating Budget Energy Budget Population Size Full Time Students Sources Total expenditures for fiscal year (dollars). Monetary sum the school spends on providing energy (electricity and natural gas) to oncampus buildings (dollars). Sheryl Bradshaw Population of full time students. Registrar’s Office (Must Complete Online Data Request Form) – Gail Gentry Registrar’s Office (Must Complete Online Data Request Form) – Gail Gentry Registrar’s Office (Must Complete Online Data Request Form) – Gail Gentry Keith Larey & Melanie Oelfke Keith Larey & Melanie Oelfke Part-Time Students Population of part-time students. Summer School Students Population of summer school students. Faculty Faculty population. Staff Staff population. Physical Size Physical Size of Campus Buildings Physical Size of Research Space Scope 1 Emissions Size of all on campus buildings (ft2). Size of research space (ft2). Fuels Used on Campus Natural Gas Gasoline Fleet Sheryl Bradshaw John Jennings – Keeps a Master Spreadsheet Steve Goldsmith & John Jennings Fuel used for heating, hot John Jennings water, and cooking (MMBtu). Gasoline used for - Linda Welch college-owned vehicles (Physical Plant including physical plant, Purchased Fuel) police, biology vans, and staff vehicles (gallons). Personal miles put on fleet vehicles not included. - - - Keith Larey (Business/Personal Miles on College Vehicles by Calendar Year), Caleb Smith (Mileage of Biology Vans) Becky Roberts (Campus Police Purchased Fuel) Refrigerants and Chemicals Various Refrigerants Refrigerants that escaped John Jennings when maintaining equipment (lbs). Fertilizer Amount of Fertilizer Amount of Fertilizer John Jennings (lbs). % Nitrogen % nitrogen in fertilizer. If John Jennings different % nitrogen for different fertilizer types, take weighted average of % nitrogen. Scope 2 Emissions Purchased Electricity Custom Fuel Mix Amount of electricity and John Jennings the fuel mix (coal, natural gas, nuclear, and renewable energy sources) used by oncampus buildings (kWh). Exact fuel mix of electric John Jennings & Peter utility. % coal, natural Schulze gas, nuclear, renewable, and purchased by unknown grid sources. Scope 3 Emissions Commuting Student Automobile Fuel Efficiency Commuting behavior was used to calculate gallons of gasoline used by commuters per year. Average mpg of student Online Survey of Students vehicles driven to campus. Average from car year, make and model. EPA mpg averages were used % Students Drive Personal Vehicle % Students that Carpool Student Trips per Week Student Weeks per Year Student Miles per Trip Faculty Automobile Fuel Efficiency % Faculty Drive Personal Vehicle % Faculty that Carpool Faculty Trips per Week Faculty Weeks per Year Faculty Miles per Trip Staff Automobile Fuel Efficiency % Staff Drive Personal (www.fueleconomy.gov). % of students that drive personal vehicles to campus. % of students that drive personal vehicles that carpool to campus. Carpooling is defined as two or more passengers. Average trips per week students commuted. Average weeks per year students commuted. Average distance per round trip that students commuted (miles). Average mpg of faculty vehicles driven to campus. Average from car year, make and model. EPA mpg averages were used (www.fueleconomy.gov). % of faculty that drive personal vehicles to campus. % of faculty that drive personal vehicles that carpool to campus. Carpooling is defined as two or more passengers. Average trips per week faculty commuted. Average weeks per year faculty commuted. Average distance per round trip that faculty commuted (miles). Average mpg of staff vehicles driven to campus. Average from car year, make and model. EPA mpg averages were used (www.fueleconomy.gov). % of staff that drive Online Survey of Students Online Survey of Students Online Survey of Students Online Survey of Students Online Survey of Students Online Survey of Faculty Online Survey of Faculty Online Survey of Faculty Online Survey of Faculty Online Survey of Faculty Online Survey of Faculty Online Survey of Staff Online Survey of Staff Vehicle personal vehicles to campus. % Staff that Carpool % of staff that drive personal vehicles that carpool to campus. Carpooling is defined as two or more passengers. Staff Trips per Week Average trips per week staff commuted. Staff Weeks per Year Average weeks per year staff commuted. Staff Miles per Trip Average distance per round trip that staff commuted (miles). Directly Financed Air Travel Faculty/Staff Directly Total distance of Financed Air Travel faculty/staff plane travel that the school wholly or partially finances in the fiscal year (miles). ** Cassie Ensminger collected coaching staff air travel data. Student Directly Financed Air Travel Total distance of student plane travel that the school wholly or partially finances in the fiscal year (miles). Only athletic teams in this figure. Other Directly Financed Travel Bus Travel Charter bus distance from fiscal year (miles). Only athletic teams in this figure. Mileage Distance driven on Reimbursements for personal vehicles that the Personal Vehicle Use college reimbursed (miles). The IRS mileage rates were used to calculate mileage (IRS Standard Mileage Rates, 2008). Online Survey of Staff Online Survey of Staff Online Survey of Staff Online Survey of Staff - ** New Technique Needed for Faculty & Staff Air Travel; Data Not Readily Available in Business Office or HR - Julie Travis (Coaching Staff Air Travel) Julie Travis (Student Athletic Flights) Julie Travis ** New Technique Needed; Data Not Readily Available in Business Office or HR Study Abroad Travel Study Abroad Air Travel Waste Solid Waste Wastewater Purchased Materials Office Paper Offsets Offsets With Additionality: High end Retail Offsets Total distance of semester and yearlong study abroad flights and January term flights per fiscal year (miles). - ** Cassie Ensminger collected all data. - Solid waste sent to the landfill from Austin College trash receptacles. Measured in short tons (2,000 lbs). - Water sent to the city wastewater treatment plant (gallons). Valerie Roberts of Center for Global Learning (Semester and Year-Long Study Abroad) Margie Norman (January Term, CSOC, and NSOC) John Jennings (Number of Receptacles and Frequency of PickUp) - Jade Rutledge (Use Same Calculations as FY 2008) John Jennings Amount of office paper used per year (lbs). Debra Reed Purchased offsets for January Term air miles; enter only total offset miles into “Study Abroad Air Miles” to determine total MT-eCO2 offset; enter MT-eCO2 offset into “High End Retail Offsets” (Additionality). January Term Air Travel Miles from Valerie Roberts & Margie Norman; Discuss with Peter Schulze Summary of Alterations to the Calculator Alteration to CACP Calculator Student, faculty, and staff personal vehicle mileage altered to represent campus commuting habits based on survey results; vehicle mileages averaged and entered for FY 2010; same procedure used in Rutledge’s FY 2008 inventory Study abroad air miles kg CO2/mile multiplied by 0.64 to represent smaller proportion of emissions for long (overseas) flights as opposed to domestic flights; take-off and landing portions of flights yield highest emissions; directly financed faculty/staff air travel not multiplied by 0.64; majority of these flights assumed to be domestic Input Page on CACP Calculator Column(s) in CACP Calculator Input_Commuter V, BG, CR EF_CO2 BF Note: must double-click into equation and add “*0.64” to end BN kg CO2/mile for all air miles multiplied by 2 (instead of 2.7) to reflect best estimate of radiative forcing index (RFI) EF_Transportation Note: must double-click into equation and delete “.7” from end Calculator Data and Corresponding Input Page/Column(s) Input Page Input_InflAdj CustFuelMix Input_Commuter Input Data to Input Operating budget Energy budget % Coal % Natural Gas % Nuclear Students Commuters Students One-Way Trips / Week Students Weeks / Year Students Drive Alone % Students Carpool % Students Drive Alone Miles Students Carpool Miles Faculty Commuters Faculty One-Way Trips / Week Faculty Weeks / Year Faculty Drive Alone % Faculty Carpool % Faculty Drive Alone Miles Faculty Carpool Miles Staff Commuters Staff One-Way Trips / Week Staff Weeks / Year Staff Drive Alone % Staff Carpool % Staff Drive Alone Miles Staff Carpool Miles Full-time students Part-time students Summerschool students Faculty Staff Total building (sq. ft.) Total research building Column in CACP Calculator C E E F I C D F I J Q R AN AO AQ AT AU BB BC BY BZ CB CE CF CM CN G H I J K L M (sq. ft.) Natural gas (MMBtu) Gasoline fleet (gallons) Diesel fleet (gallons) HFC-134a (lbs.) HFC-404a (lbs.) HCFC-22 (lbs.) Other refrigerants (lbs.) Synthetic fertilizer (lbs.) % Nitrogen Purchased electricity (kWh) Directly financed faculty/staff air miles Directly financed student air miles Directly financed bus miles Personal mileage reimbursement Study abroad air miles Solid waste no CH4 recovery (short tons) Wastewater aerobic (gallons) Paper 0% recycled (lbs.) Paper 100% recycled (lbs.) Offsets (high end retail offsets with additionality) Green power certificates (nonadditional) AI AV AW BF BG BH BK BL BM BX CK CL CO CQ CR CZ DD DG DK DN DQ