F R O N T The PowerSafe® V Front Terminal range of valve regulated lead acid batteries has been designed specifically for use in applications that demand the highest levels of security and reliability. With proven compliance to the most rigorous T E R M I N A L INTRODUCTION TO THE 12V190F MONOBLOC international standards, PowerSafe V batteries are recognised worldwide as a premium solution for Telecom applications. The reputation of PowerSafe V batteries for long service life, together with excellent high rate performance, also makes it ideal for high integrity, high specification UPS systems. PowerSafe V batteries deliver superior performance while occupying less space than conventional standby power batteries. A range of compact designs, suitable for 19", 23" and ETSI racking, provides users with the benefit of increased energy density. With all electrical connections at the front, installation and inspection are both quicker and easier. The 12V190F front terminal monobloc is the latest addition to the hugely successful EnerSys® PowerSafe V battery range. Its large capacity and compact design enable EnerSys to satisfy customers' ever increasing demand for superior energy density products. Features & Benefits 12V, 190Ah monobloc (C10/1.80Vpc/20°C) Compact design & superior energy density: more back-up power in same space Front terminal connections for fast and easy installation and maintenance Ideal for use in industry-standard power cabinets UL94 V-0 flame retardant case and lid Long design life RESERVE POWER Publication No: EN-VFT-190F-002 - February 2009 Construction • Positive plates designed to prolong • service life and enhance corrosion resistance • • • • • Separators in low resistance microporous glass fibre. The electrolyte is absorbed within this material, preventing acid spills in case of accidental damage Flame arrestors built into each bloc for increased operational safety Rope handles fitted as standard for ease of handling Installation & Operation • Monoblocs are designed for installation in cabinets or on stands, close to the point of use. A separate battery room is not necessary Case and lid in flame retardant ABS material, highly resistant to shocks and vibrations • Terminal with brass insert for maximum conductivity and with high compression grommet for long life It is recommended that PowerSafe® 12V190F batteries are installed on their base • Recommended float charge voltage: 2.280Vpc at 20°C (68°F) 2.265Vpc at 25°C (77°F) • • Six months shelf life at 20°C Self-regulating pressure relief valve prevents ingress of atmospheric oxygen Standards • Tested according to international standard IEC 60896-21 and compliant to defined requirements of IEC 60896-22 • Classified as “Long Life” according to the Eurobat Guide 1999 • Designed to meet Telcordia SR-4228 requirements • • Recognised by UL (UL Standard 1989) • Manufactured in EnerSys® ISO 9001:2000 and ISO 14001:2004 certified production facilities Approved to be shipped as nonhazardous cargo in accordance with the requirements of IMDG (International Maritime code for Dangerous Goods) and OICA (Organisation of International Civil Aviation) Reduced maintenance: no water addition required General Specifications Nominal Capacity (Ah) 10 hr rate Nominal to 1.80Vpc Voltage (V) @ 20°C Number of Cells 12V190F 6 12 190 Nominal Dimensions 8 hr rate to 1.75Vpc @ 77°F Length mm in 190 561 Overall Height mm in Width mm in 22.1 125 4.9 316 12.4 kg Typical Weight lbs 57.3 126.3 Short Circuit Current (A) Internal Resistance (mΩ) Terminals 3625 3.50 M6 M Discharge Currents (Amperes) at 20°C Standby Time (Minutes) Standby Time (Hours) Voltage (V) 30 35 40 45 1 2 3 4 5 6 7 8 9 10 1.85 1.80 1.75 1.71 1.67 1.65 1.63 1.60 196.3 208.5 217.9 224.3 229.6 231.6 233.3 235.0 179.1 188.7 196.2 201.4 205.4 207.2 208.6 210.0 163.3 172.6 178.9 183.3 186.7 188.0 189.2 190.1 150.8 159.1 164.7 168.5 171.5 172.6 173.5 174.2 123.0 129.5 133.5 136.0 138.0 138.8 139.4 140.0 73.2 76.0 77.6 78.6 79.3 79.6 79.8 79.9 52.6 54.3 55.3 55.9 56.3 56.5 56.6 56.6 41.1 42.5 43.2 43.6 44.0 44.1 44.2 44.2 33.9 35.0 35.6 35.9 36.2 36.3 36.3 36.3 28.9 29.8 30.3 30.6 30.8 30.9 31.0 31.0 25.3 26.1 26.5 26.8 26.9 27.0 27.0 27.0 22.4 23.2 23.5 23.8 23.9 24.0 24.0 24.0 20.2 20.8 21.2 21.4 21.6 21.6 21.6 21.6 18.4 19.0 19.3 19.5 19.6 19.6 19.7 19.7 Standby Time (Minutes) Standby Time (Hours) Voltage (V) 30 35 40 45 1 2 3 4 5 6 7 8 9 10 1.85 1.80 1.75 1.71 1.67 1.65 1.63 1.60 402.6 363.9 332.8 311.7 255.7 151.2 108.3 84.7 69.7 59.9 52.3 45.7 41.9 37.3 420.8 436.3 457.2 378.8 390.0 412.7 347.4 356.5 376.6 323.0 332.4 346.8 263.6 270.2 281.4 154.6 157.4 163.7 110.5 112.2 116.8 86.3 87.6 91.2 71.0 72.0 75.1 61.4 62.1 63.9 53.7 54.3 55.7 46.6 47.3 49.4 43.0 43.5 44.4 38.0 38.6 40.4 454.6 457.8 460.5 402.8 402.8 402.8 366.4 366.4 366.4 343.3 345.1 346.5 277.6 278.8 279.8 160.4 160.9 161.2 114.1 114.3 114.5 88.9 89.1 89.3 73.1 73.2 73.4 62.6 62.7 62.8 54.7 54.8 54.9 48.0 48.1 48.2 43.8 43.9 43.9 39.2 39.3 39.4 463.3 402.8 366.4 348.0 280.7 161.4 114.7 89.4 73.4 62.8 54.9 48.2 44.0 39.4 Contact: EnerSys P.O. Box 14145 Reading, PA 19612-4145 USA Tel: +1-610-208-1991 +1-800-538-3627 Fax: +1-610-372-8613 www.enersys-emea.com EnerSys Europe Zurich, Switzerland EnerSys Asia Guangdong, China Tel: +86-755-2689 3639 EnerSys Ltd. Rake Lane, Clifton Junction, Swinton, Manchester M27 8LR, UK Tel: +44 (0)161 794 4611 Fax: +44 (0)161 727 3809 © 2009 EnerSys. All rights reserved. Trademarks and logos are the property of EnerSys and its affiliates unless otherwise noted. Publication No. EN-VFT-190F-002 - February 2009 - Subject to revisions without prior notice. E.&O.E. Constant Power Discharge (Watts per cell) at 20°C