Safety & Environmental Solutions PRO Alarm™ Hydrogen Gas Detector For Flooded Lead-Acid Batteries in Charging Rooms and Other Areas Where Hydrogen Gas Is Present Features: • Automatic Operation • Continuous Monitoring • High Sensitivity • High Stability • Solid State Reliability Flooded lead-acid batteries on charge emit hydrogen gas after reaching the 80% charge point. Concentrations of 4% and higher mixed with air may be explosive. A PRO Alarm™ hydrogen gas detector will provide a warning and facilitate the dissipation of hydrogen concentrations before they reach the lower explosive limit (LEL) of 4%. In addition to protecting your employees and property, the detector may also reduce the following costs: A. Electricity – Heating – Air Conditioning. Instead of continuously running an exhaust fan to prevent gas accumulation, the detector will activate a fan only if it is needed. B. Insurance. Installation of a detector may result in a premium reduction. • Intrinsically Safe - 12-Volt Operating Voltage • Easy Installation • Low Cost • Two Year Warranty Model Number Accessories 801550 801550-DR 801550-BOX 801550-EXT 801550-REMOTE 801550-14FT. 801550-25FT. 801550-50FT. 801550-60FT. PRO Alarm™ PRO Alarm™ Dual Relay Optional Junction Box 30’ Extension w/Sensor Remote Panel Box Modular Cable, 14' Modular Cable, 25' Modular Cable, 50' Modular Cable, 60' Always follow local, state, and OSHA guidelines when locating and installing the detector. P r o t e c t s L i f e , P r o p e r t y, a n d P r o f i t s Typical Installation Specifications: Hydrogen Gas Detector Mount on or near the ceiling. Optional Steel Junction Box For hardwiring through a conduit. Mates with the gas detector box. Dimensions – Height 7" (17.8 cm) Width 4 3/4"(12.0 cm) Depth 2 1/2"( 5.5 cm) Mounting – Four Screws-3/16" ( 4.5 cm) Optional Modular Cable 6 position, 6 contact, standard style. Cable can be any length. Optional Remote Includes duplicate: Push-to-Test Button Power-On Green LED 1% Caution Yellow LED 2% Warning Red LED Available with or without a buzzer. Power Requirements – 120 AC Volts, 50/60 Hz *220 AC Volts & 12 DC Volts also available Relay(s) – Standard, Normally-Open, 10 A Contacts *Normally-Closed available upon request Dual Relay Model, 2 Normally-Open Warning: This protector is added protection, not a substitute for prudent safety measures where hydrogen gas is present. For large or highly sensitive areas, use two or more detectors. EnerSys 2366 Bernville Road Reading, PA 19605 Phone: 800-ENERSYS Email: mpe@enersys.com Web: www.enersys.com EnerSys Canada 61 Parr Boulevard Bolton, Ontario L7E 4E3 Canada Phone: 800-693-9433 Fax: 905-951-4441 EnerSys Mexico Ave. Lopez Mateos 4210-A Col. Casablanca C.P. 66475 San Nicolas de los Garza, N.L. Mexico Phone: (52+81) 8329-6400 Section 85.35 Print Date 04/12 ©2012 EnerSys. All rights reserved. Trademarks and logos are the property of EnerSys and its affiliates except ISO which is not the property of EnerSys. Subject to revisions without prior notice. E.&O.E.