01/29/16 DESIGN NO. _____ NEW YORK CITY SCHOOL CONSTRUCTION AUTHORITY STANDARD SPECIFICATIONS 1 TABLE OF CONTENTS 01/29/16 DIVISION 1 - GENERAL & SUPPLEMENTARY REQUIREMENTS 2 GENERAL REQUIREMENTS G01000 G01015 G01200 G01600 G01700 G01720 G01740 3 - SPECIFICATIONS FORMAT MISCELLANEOUS PROVISIONS PROJECT MEETINGS MATERIAL AND EQUIPMENT PROJECT CLOSEOUT RECORD DOCUMENTS GUARANTEES, WARRANTIES, & BONDS SUPPLEMENTARY REQUIREMENTS S01010 S01060 S01300 S01311 S01312AS01312BS01313 S01352 S01400 S01426 S01500 S01524 S01535 S01550 S01560 S01630 S01650 S01660 S01730 S01900 NYCSCA – – – – – - SUMMARY OF WORK PERMITS, FEES, AND CERTIFICATES OF OCCUPANCY SUBMITTALS PROGRESS SCHEDULE (CAPACITY PROJECTS) PROGRESS SCHEDULE (CAPITAL IMPROVEMENT PROJECTS > $1 Mil) PROGRESS SCHEDULE (CAPITAL IMPROVEMENT PROJECTS < $1 Mil) PROGRESS SCHEDULE (UPK CENTER PROJECTS) SUSTAINABILITY REQUIREMENTS QUALITY CONTROL SAMPLE CLASSROOM TEMPORARY FACILITIES AND CONTROLS CONSTRUCTION WASTE MANAGEMENT SAFETY PROGRAM INDOOR AIR QUALITY (IAQ) REQUIREMENTS INSTALLATION SEQUENCE OF FINISH MATERIALS PRODUCT SUBSTITUTIONS FACILITY START-UP, DEMONSTRATION, AND TRAINING SUPPLEMENTAL COMMISSIONING REQUIREMENTS SYSTEMS OPERATION AND MAINTENANCE MANUALS EXISTING PREMISES WORK 1 TABLE OF CONTENTS 01/29/16 DESIGN NO. _____ DIVISION 2 - SITEWORK 02060 02070 02081 02082 02085 02091 - 02100 02200 02200A02200B02201 – 02215 02250 02360 – 02511 02513 02514 02515 02516 – 02521 02531 02532 02533 02541 – 02580 02711 02721 02722 02723 02724 02725 02831 02860 02862 02870 02900 - BUILDING DEMOLITION SELECTIVE REMOVALS & DEMOLITION ASBESTOS ABATEMENT PCB-CONTAINING CAULK REMOVAL WORK EXTERIOR PAINT REMOVAL STORAGE, HANDLING, TRANSPORTATION AND DISPOSAL OF PETROLEUM CONTAMINATED AND/OR HAZARDOUS WASTES SITE PREPARATION EARTHWORK EARTHWORK (FLOW-THROUGH TURF AF) EARTHWORK (FLOAT DRAIN TURF OR NATURAL GRASS AF) EARTHWORK CONTROLLED LOW STRENGTH MATERIAL FOUNDATION AND OTHER CHANGE ADJUSTMENTS DRIVEN PIPE-PILE FOUNDATIONS ASPHALTIC CONCRETE PAVING SIDEWALK AND STREET PAVING POROUS ASPHALT PAVEMENT TEST STRIP UNIT PAVERS EXPOSED POROUS ASPHALT PAVING AND AGGREGATE BASE CONCRETE CURBS AND PAVEMENTS RESILIENT SURFACING RESILIENT SURFACING - POROUS BASE COLORED ATHLETIC WEARING SURFACE SYNTHETIC TURF – TPE INFILL TRACK/COURT/PLAYGROUND MARKINGS WALL SUBDRAINAGE SYSTEMS TRENCH DRAINS PRECAST CONCRETE CATCH BASINS, DETENTION BASINS, BOX CULVERTS, AND MANHOLES STORM DRAINAGE SYSTEMS UNDERDRAIN SYSTEM FOR POROUS ASPHALT PAVING UNDERDRAIN SYSTEM FOR SKINNED AREAS CHAIN LINK FENCES AND GATES EARLY CHILDHOOD PLAYGROUND EQUIPMENT OUTDOOR GAME EQUIPMENT SITE AND STREET FURNISHINGS LANDSCAPING DIVISION 3 - CONCRETE 03005 03100 03200 03200A03300 03542 NYCSCA CONCRETE WORK CONCRETE FORMWORK CONCRETE REINFORCEMENT CONCRETE REINFORCEMENT - (EPOXY) CAST-IN-PLACE CONCRETE CEMENT-BASED SELF-LEVELING UNDERLAYMENT 2 TABLE OF CONTENTS 01/29/16 03610 03733 03735 03736 03740 - DESIGN NO. _____ GROUTING CONCRETE REPAIR WORK CONCRETE ROOF FILL AND SCREED REPAIR WORK EPOXY INJECTION REPAIR WORK MIGRATING CORROSION INHIBITOR DIVISION 4 - MASONRY 4 04200 - UNIT MASONRY 04250 - TERRA COTTA 04270 - GLASS UNIT MASONRY – see March Energy 04420 - EXTERIOR CUT STONE 04435 - CAST STONE 04510 - MASONRY CLEANING 04510A - MASONRY CLEANING - (SHPO) 04520 - MASONRY RESTORATION 04520A - MASONRY RESTORATION – (SHPO) 04700 - SIMULATED MASONRY DIVISION 5 - METALS 05120 05121 05170 05210 05220 05230 05300 05500 05580 05700 05710 05810 - STRUCTURAL STEEL STRUCTURAL STEEL SUPPORT SYSTEM FOR SUSPENDED CEILINGS OPEN WEB STEEL JOIST, K-SERIES LONGSPAN STEEL JOISTS, LH-SERIES STEEL JOIST GIRDERS METAL DECK METAL FABRICATIONS SHEET METAL FABRICATIONS ORNAMENTAL METAL STEEL STAIRS PREFABRICATED EXPANSION JOINT COVERS DIVISION 6 - WOOD AND PLASTICS 06100 - ROUGH CARPENTRY 06200 - FINISH CARPENTRY 06410 - CUSTOM CASEWORK NYCSCA 3 TABLE OF CONTENTS 01/29/16 DESIGN NO. _____ DIVISION 7 - THERMAL AND MOISTURE PROTECTION 07110 07115 07120 07147 07150 07160 07211 07212 07250 07260 07270 07272 07314 07321 07520 07553 07555 – – - 07560 07561 – 07565 07600 07610 07720 07900 - SHEET MEMBRANE WATERPROOFING SHEET MEMBRANE WATERPROOFING FOR FOUNDATIONS FLUID-APPLIED WATERPROOFING FOR PLAZA DECKS CRYSTALLINE WATERPROOFING CHEMICAL RESIN INJECTION GROUTING BITUMINOUS DAMPROOFING PERIMETER FOUNDATION INSULATION MISCELLANEOUS BUILDING INSULATION SPRAYED FIRE-RESISTIVE MATERIALS INTUMESCENT FIRE-RESISTANT COATINGS FIRESTOPPING/SMOKE SEALS FLUID-APPLIED MEMBRANE AIR BARRIER, VAPOR RETARDING SLATE SHINGLES CLAY TILE ROOFING ROOF FLASHING AND RELATED ROOF REPAIR WORK HYBRID BUILT-UP/SBS MODIFIED BITUMINOUS ROOFING COLD FLUID-APPLIED RESIN ROOFING – BUILT-UP ROOFING SYSTEM FLUID-APPLIED PROTECTED MEMBRANE ROOFING FLUID-APPLIED PROTECTED MEMBRANE ROOFING (PLANTED TYPE I) COLD FLUID-APPLIED RESIN ROOFING – PROTECTED MEMBRANE ROOFING SYSTEM FLASHING AND SHEET METAL SHEET METAL ROOFING ROOF ACCESSORIES JOINT SEALERS DIVISION 8 - DOORS AND WINDOWS 08110 08210 08211 08220 08305 08330 08510 08522 08524 08610 08621 08662 08710 08730 08800 08920 – - NYCSCA STEEL DOORS AND FRAMES WOOD DOORS WOOD DOORS FIBERGLASS REINFORCED POLYESTER DOORS ACCESS DOORS COILING DOORS, GRILLES AND SHUTTERS STEEL WINDOWS - PROJECTED, CASEMENT, PIVOTED, HUNG ALUMINUM DOUBLE-HUNG WINDOWS ALUMINUM PROJECTED WINDOWS REPLACEMENT WOOD WINDOWS FIBERGLASS SANDWICH PANEL SKYLIGHTS SECURITY SCREENS/BARRIERS FINISH HARDWARE THRESHOLDS, WEATHERSTRIPPING AND SEALS MISCELLANEOUS GLAZING ALUMINUM CURTAIN WALLS 4 TABLE OF CONTENTS 01/29/16 DESIGN NO. _____ DIVISION 9 - FINISHES 09205 09210 09260 09310 09410 09510 09590 09626 09650 09670 09675 09680 09685 09705 09800 09860 09900 – – – - FURRING AND LATHING PLASTER GYPSUM BOARD ASSEMBLIES CERAMIC TILE TERRAZZO - PORTLAND CEMENT ACOUSTICAL CEILINGS WOOD FLOORING RESILIENT ATHLETIC FLOORING RESILIENT FLOORING VINYL SHEET ATHLETIC FLOORING FLUID-APPLIED EQUIPMENT ROOM FLOORING CARPET TILE CARPETING RESINOUS FLOORING SPECIAL COATINGS GRAFFITI RESISTANT COATINGS PAINTING DIVISION 10 - SPECIALTIES 10100 10151 10160 10185 10214 10270 10350 10400 10415 - 10505 10522 10605 10652 10653 10655 10675 10720 10810 10830 10840 – – - VISUAL DISPLAY BOARDS TOILET COMPARTMENTS FACTORY-PAINTED STEEL TOILET COMPARTMENTS PLASTIC SHOWER AND DRESSING COMPARTMENTS STATIONARY METAL WALL LOUVERS ACCESS FLOORING FLAGPOLE IDENTIFYING DEVICES BULLETIN BOARDS, GLAZED DISPLAY BOARDS, DISPLAY CABINETS AND CASES METAL LOCKERS FIRE EXTINGUISHERS AND CABINETS WIRE MESH WORK ELECTRICALLY OPERATED FOLDING PANEL PARTITIONS MANUALLY OPERATED FOLDING PANEL PARTITIONS ACCORDION FOLDING PARTITIONS METAL STORAGE SHELVING WINDOW GUARDS TOILET AND BATH ACCESSORIES MIRRORS GRAB BARS DIVISION 11 - EQUIPMENT 11050 – LIBRARY EQUIPMENT NYCSCA 5 TABLE OF CONTENTS 01/29/16 DESIGN NO. _____ 11061 - PLATFORM CURTAINS, AUDITORIUM WINDOW CURTAINS, PROJECTION SCREEN 11172 - WASTE HANDLING EQUIPMENT 11173 - WASTE HANDLING EQUIPMENT 11400 - FOOD SERVICE EQUIPMENT 11401 - FOOD SERVICE EQUIPMENT FOR WARMING PANTRY 11450 - DOMESTIC TYPE EQUIPMENT 11452 - CULINARY ARTS LAB EQUIPMENT 11460 - UNIT KITCHEN 11480 - GYMNASIUM EQUIPMENT 11481 - EXERCISE ROOM PADDING 11500 - SHOP EQUIPMENT 11600 - LABORATORY EQUIPMENT DIVISION 12 - FURNISHINGS 12302 12345 12485 12500 12501 12545 12710 12761 – – – - MANUFACTURED WOOD CASEWORK SOAPSTONE FOOT GRILLES WINDOW SHADES CHAIN AND CLUTCH OPERATED WINDOW SHADES DRAPERIES FIXED AUDIENCE SEATING WOOD BLEACHERS DIVISION 13 - SPECIAL CONSTRUCTION 13120 - STEEL BLEACHERS 13031 – WALK-IN TRASH REFRIGERATOR DIVISION 14 - CONVEYING SYSTEMS 14120 14210 14211 14240 14241 14250 14315 14316 14420 14421 14510 – – – - NYCSCA ELECTRIC DUMBWAITERS MRL TRACTION PASSENGER ELEVATORS GEARED TRACTION PASSENGER ELEVATORS IN-GROUND DIRECT-ACTING HYDRAULIC PASSENGER ELEVATORS HOLELESS DIRECT-ACTING HYDRAULIC PASSENGER ELEVATORS DUAL-JACK ROPED HYDRAULIC PASSENGER ELEVATORS HYDRAULIC SIDEWALK ELEVATORS GEARED TRACTION SIDEWALK ELEVATORS HYDRAULIC VERTICAL WHEELCHAIR LIFTS INDOOR INCLINED WHEELCHAIR LIFTS ESCALATORS 6 TABLE OF CONTENTS 01/29/16 DESIGN NO. _____ DIVISION 15 - MECHANICAL FIRE PROTECTION 15301 – GENERAL PROVISIONS FOR FIRE PROTECTION SYSTEMS WORK 15303 – VIBRATION ISOLATION AND SEISMIC CONTROLS, FIRE PROTECTION SYSTEMS 15330 – SPRINKLER SYSTEM 15331 – DRY STANDPIPE SYSTEM 15332 - COMBINATION WET STANDPIPE/SPRINKLER SYSTEM 15333 – FIRE PUMPS/SPRINKLER BOOSTER PUMPS PLUMBING AND DRAINAGE 15401 – GENERAL PROVISIONS FOR PLUMBING AND DRAINAGE WORK 15403 - VIBRATION ISOLATION AND SEISMIC CONTROLS, PLUMBING AND DRAINAGE SYSTEMS 15410 - PLUMBING PIPING 15411 - HANGERS AND SUPPORTS 15412 - VALVES 15413 - INSULATION (P&D) 15414 - TESTS 15415 - DRAINAGE 15416 - GAS PIPING SYSTEM 15417 - COLD WATER SUPPLY 15418 - HOT WATER SUPPLY 15431 - TAGS, CHARTS AND IDENTIFICATION 15432 - MISCELLANEOUS 15440 - PLUMBING FIXTURES 15451 - WATER HEATERS 15453 - PUMPING APPARATUS AND TANKS HEATING, VENTILATING AND AIR CONDITIONING 15501 – GENERAL PROVISIONS FOR HEATING, VENTILATING AND AIR CONDITIONING WORK 15502 - HVAC IDENTIFICATION 15503 - VIBRATION ISOLATION AND SEISMIC CONTROLS, HVAC SYSTEMS 15504 - VIBRATION ISOLATION 15510 - HVAC PIPING 15511 - VALVES (HVAC) 15512 - PIPING INSULATION (HVAC) 15513 - EQUIPMENT INSULATION (HVAC) 15514 - DUCTWORK INSULATION 15515 - HYDRONIC SPECIALTIES 15516 - WATER TREATMENT FOR STEAM BOILERS 15517 - WATER TREATMENT FOR HYDRONIC SYSTEMS NYCSCA 7 TABLE OF CONTENTS 01/29/16 15525 15540 15555 15556 15557 15559 15560 15565 15570 15575 15580 15590 15592 15593 15594 15596 15610 15650 15660 15670 15756 15781 15783 15792 15835 15836 15838 15839 15852 – – – – – – - 15853 15854 15855 15857 15860 15864 15865 15872 15885 15891 15910 15915 15930 15931 15932 15933 - NYCSCA DESIGN NO. _____ STEAM AND CONDENSATE SPECIALTIES HVAC PUMPS FIRE-TUBE BOILERS (STEAM) CAST-IRON BOILERS FIRE-TUBE BOILERS (HOT WATER) FLEXIBLE WATER-TUBE BOILERS (STEAM) FLEXIBLE WATER-TUBE BOILERS (HOT WATER) HOT WATER CONDENSING BOILERS BOILER ACCESSORIES BREECHING, CHIMNEY AND STACKS FEEDWATER EQUIPMENT EMERGENCY GENERATOR SYSTEM-ACCESSORIES FUEL BURNING/PUMPING EQUIPMENT (FOR STEAM BOILERS) FUEL BURNING/PUMPING EQUIPMENT (FOR HOT WATER BOILERS) FUEL STORAGE EQUIPMENT NATURAL GAS LEAK DETECTION EQUIPMENT GAS-FIRED DUCT FURNACES SPLIT AIR COOLED CHILLERS PACKAGED MODULAR OUTDOOR CHILLERS PLATE HEAT EXCHANGERS CONVERTERS PACKAGED HEATING AND COOLING UNITS SPLIT HEAT PUMP SYSTEM COILS CONVECTORS UNIT HEATERS/CABINET HEATERS FAN COIL UNITS DOOR AIR CURTAINS AIR HANDLING UNITS LOCATED WITHIN INTERIOR OF THE BUILDING CUSTOM PACKAGED ROOFTOP HEATING AND COOLING UNITS (VARIABLE AIR VOLUME SYSTEM) CUSTOM PACKAGED ROOFTOP HEATING AND COOLING UNITS (CONSTANT VOLUME SYSTEM) COMMERCIAL PACKAGED ROOFTOP HEATING AND COOLING UNITS UNIT VENTILATOR CENTRIFUGAL FANS PROPELLER FANS AXIAL FLOW FANS GRAVITY ROOF VENTILATOR AIR FILTERS METAL DUCTWORK DUCT ACCESSORIES DAMPERS VARIABLE AIR TERMINALS FAN-POWERED VARIABLE AIR VOLUME (VAV) TERMINAL UNITS ACTIVE CHILLED BEAMS DEDICATED OUTSIDE AIR SYSTEM (DOAS) AND DECOUPLED RECIRCULATING AIR HANDLING (DRU) UNITS 8 TABLE OF CONTENTS 01/29/16 DESIGN NO. _____ 15934 - ROOFTOP AIR HANDLING UNITS FOR PUBLIC ASSEMBLY SPACES (CONSTANT VOLUME SYSTEM) 15935 - SINGLE ZONE VARIABLE AIR VOLUME (SZVAV) AIR HANDLING UNITS FOR PUBLIC ASSEMBLY SPACES 15936 - HOT WATER RADIANT FLOOR HEATING SYSTEM 15937 – DISPLACEMENT INDUCTION UNITS 15940 - AIR OUTLETS AND INLETS 15970 - TEMPERATURE CONTROL SYSTEM (LONWORKS BMS/DDC WITH SCHOOL OPERATING CONSOLE) 15971 – TEMPERATURE CONTROL SYSTEM (LONWORKS DDC ONLY) 15973 - FACILITY MANAGEMENT SYSTEMS INTEGRATION 15974 - PNEUMATIC TEMPERATURE CONTROL SYSTEM WITH SPACE WIRELESS PNEUMATIC THERMOSTATS (WPT) 15980 - THERMOMETERS AND GAUGES 15985 - SEQUENCE OF OPERATIONS 15992 - CLEANING AND TESTING 15993 - BALANCING OF SYSTEMS DIVISION 16 - ELECTRICAL 16010 - GENERAL PROVISIONS FOR ELECTRICAL WORK 16013 - VIBRATION ISOLATION AND SEISMIC CONTROLS, ELECTRICAL SYSTEMS 16120 - WIRING SYSTEMS 16130 - RACEWAYS, FITTINGS, SUPPORTING DEVICES, BOXES AND ACCESSORIES 16140 - WIRING DEVICES 16145 - LIGHTING CONTROL DEVICES 16146 – WIRELESS LIGHTING CONTROL DEVICES 16231 - EMERGENCY GENERATOR SYSTEM 16289 - TRANSIENT VOLTAGE SURGE SUPPRESSION 16420 - SERVICE ENTRANCE EQUIPMENT 16425 - SWITCHBOARDS 16441 - ENCLOSED SWITCHES 16450 - GROUNDING AND BONDING 16460 - TRANSFORMERS 16470 - PANELBOARDS 16471 - AUDITORIUM AND TELEVISION STUDIO DIMMING SYSTEM 16472 - SCIENCE LABORATORY POWER UNITS 16475 - OVERCURRENT PROTECTIVE DEVICES, CIRCUIT BREAKERS AND FUSES 16480 - MOTORS, MOTOR CONTROL CENTERS, STARTERS AND CONTROL EQUIPMENT 16500 - INTERIOR BUILDING LIGHTING 16501 - LAMPS, BALLASTS AND ACCESSORIES 16502 – LED INTERIOR BUILDING LIGHTING 16520 - ILLUMINATED EXIT SIGN AND EMERGENCY LIGHTING FIXTURES 16530 – LED SITE/SECURITY LIGHTING 16670 - LIGHTNING PROTECTION NYCSCA 9 TABLE OF CONTENTS 01/29/16 DESIGN NO. _____ 16671 - EARLY STREAMER EMITTER LIGHTNING PROTECTION 16701 - AUXILIARY SIGNAL SYSTEMS 16720 - FIRE DETECTION AND ALARM SYSTEM WITH CENTRAL OFFICE CONNECTION 16722 – CARBON MONOXIDE DETECTION AND ALARM SYSTEM WITH CENTRAL OFFICE CONNECTION 16723 - FIRE DETECTION AND ALARM SYSTEM WITH EMERGENCY VOICE/ ALARM COMMUNICATION AND CENTRAL OFFICE CONNECTION 16724 - INTRUSION ALARM SYSTEM 16725 - TELEPHONE CABLING SYSTEM 16726 - INTERCOM SYSTEM FOR FIRE RESCUE AREAS AND EMERGENCY TELEPHONE FOR ELEVATORS 16727 - DATA CABLING SYSTEM 16728 - FIBER OPTIC CABLING SYSTEM 16729 - TELEPHONE CABLING SYSTEM (SMALL SYSTEM) 16730 – DATA CABLING SYSTEMS (SMALL SCHOOLS) 16770 - SOUND, INTERCOM AND TEACHER ACTIVATED SECURITY SYSTEM 16771 - PROJECTION AND INTERACTIVE WHITEBOARD SYSTEMS 16772 - SOUND, INTERCOM AND TEACHER ACTIVATED SECURITY SYSTEM (SMALL SYSTEM) 16783 - INTERNET PROTOCOL DIGITAL VIDEO SURVEILLANCE SYSTEM (IPDVS) CABLING SYSTEM (CAPACITY PROJECTS - NEW CONSTRUCTION) 16784 - INTERNET PROTOCOL DIGITAL VIDEO SURVEILLANCE SYSTEM (IPDVS) CABLING SYSTEM (CAPITAL IMPROVEMENT PROJECTS) 16786 - SECTION 16786 - INTERNET PROTOCOL DIGITAL VIDEO SURVEILLANCE (IPDVS) CABLING SYSTEM USING DIGITAL CAMERAS (CAPITAL IMPROVEMENT PROJECTS) 16791 - SELF-CORRECTIVE CLOCK SYSTEM 16792 - WIRELESS CLOCK SYSTEM 16793 – SECONDARY CLOCK SYSTEM 16855 - HEAT TRACE CABLE SYSTEM END OF TABLE OF CONTENTS Notes to Specifier (Delete from Specifications) 1. When editing the Table of Contents for a project, revise the heading from Standard Specification to the name of the school and specific project name. It should read “Specifications for ‘Project title’ at ‘School name’”. 2. Sections in the General Requirements shall not be changed, revised, edited or omitted for projects. Include the Sections as-is in the Project Specifications. 3. Sections in the Supplementary Requirements shall be edited as required for the Project. NYCSCA 10 TABLE OF CONTENTS 01/29/16 4. DESIGN NO. _____ Choose the appropriate versions of Sections 04510 and 04520 from the SCA Standard Specifications, depending upon whether or not the building is SHPO eligible or a NYC landmark. NYCSCA 11 TABLE OF CONTENTS 01/29/16 DESIGN NO. _____ LIST OF DRAWINGS 1 COVER & GENERAL NOTES TITLE DATE DWG. NO. ARCHITECTURAL DWG. NO. TITLE DATE TITLE DATE TITLE DATE TITLE DATE TITLE DATE STRUCTURAL DWG. NO. PLUMBING DWG. NO. HVAC DWG. NO. ELECTRICAL DWG. NO. END OF LIST OF DRAWINGS Notes to Specifier (Delete from Specifications) 1. The "List of Drawings" in the specifications and on the Drawings must be identical. Any changes must be made to both lists before issuing. NYCSCA 1 LIST OF DRAWINGS 01/29/16 DESIGN NO. _____ Drawing categories should be deleted and other categories should be added to suit the specific project requirements. * * * NYCSCA 2 LIST OF DRAWINGS