customer contact details

advertisement

Tracerco Diagnostics TM Job data sheet

Tracerco Diagnostics

TM

– Tower scan

CUSTOMER CONTACT DETAILS

Name

Email address

Phone number

Site/plant

ENQUIRY SUMMARY:

Please provide a brief synopsis of your enquiry:

PROCESS DETAILS

Type of column and reference number.

Reason for Diagnostic Survey.

15/04/2020

Vessel Diameter, Wall thickness, and height

Number, type and manufacturer of trays.

Number of Packed beds, type and make of packing.

Basic process details.

Is access available to the top of the column? (If possible, please send digital photographs to confirm that additional staging is not required)

Are suitable General Arrangement drawings available showing internal features (tray heights and orientation)

Suitable General Arrangement Drawings showing internal features are required.

ADDITIONAL COMMENTS/INFORMATION

Please provide any additional information or comments.

726943640 Page 1 of 4

Tracerco Diagnostics TM Job data sheet 15/04/2020

RADIOLOGICAL DETAILS

Tracerco are likely to bring radioactive isotopes to site and therefore please provide your site contact responsible for radiological issues.

Site contact

Telephone no

Email address

Position

SAFTEY INDUCTION

Site safety inductions are integral part of our visit to your site and therefore please provide details of any requirement for a site/local plant induction.

Site contact for booking

Telephone no

Email address

Site induction required YES/NO? TIME DATE DURATION VALIDITY

Local plant induction required,

YES/NO?

TIME DATE DURATION VALIDITY

TRACERCO CONTACT DETAILS

Tracerco have a team of project managers who can process your enquiry and therefore please return the form either:

General email tracerco@matthey.com

Phone

Fax

Gary Batty gary.batty@matthey.com

+44 (0) 1642 375500

+44 (0) 1642 370704

+44 (0) 1642 375578

Barry Firby

Chris Lyth

Paul Sturdy

Matt Wilson barry.firby@matthey.com

chris.lyth@matthey.com

paul.sturdy@matthey.com

matt.wilson@matthey.com

+44 (0) 1642 375557

+44 (0) 1642 375562

+44 (0) 1642 375513

+44 (0) 1642 375584

726943640 Page 2 of 4

Tracerco Diagnostics TM Job data sheet 15/04/2020

TRACERCO Diagnostics™ - Tower Scan

The performance of the distillation train in a chemical facility is key to the performance and hence profitability of the manufacturing asset. When a problem occurs our customers require a rapid, accurate, cost effective and above all safe method of determining the most likely cause and location within the tower of the problem. That is why Tracerco have developed the TRACERCO

Diagnostics™ - Tower Scan technology, also known as gamma scanning, which is totally non-intrusive, quick to undertake and provides real time data to our customers.

This technique is also used during the pre-shutdown periods of facilities, so that the shut-down period can be minimised, reducing lost production and costs:

Features of the TRACERCO Diagnostics™ - Tower Scan

A rapid, accurate and reliable method of characterising the extent of mechanical damage within a distillation column.

A technique which enables the process conditions within a distillation column to be fully understood (flooding, foaming, weeping, carryover, etc.).

A totally non intrusive technique undertaken by a team of highly trained engineers.

Distillation column does not need to be prepared for study (insulation does not need to be removed, flooring does not need to be removed or altered.

Able to be carried out on a wide range of distillation columns (0.5 to 10 meter diameter, various down-comers, various tray / packing designs).

Rapid response available from Tracerco.

Benefits of the TRACERCO Diagnostics™ - Tower Scan

Production can continue whilst the study is being undertaken - Reducing

Downtime.

Enables the optimisation of the maintenance of the distillation column -

Reducing Time & Costs.

Eliminates the need to shut-down the column to identify damaged packing / trays - Reducing Downtime & Costs

Real time results available, so study can be customised and optimised on site

- Reducing Costs & Time.

Efficiency of the process can be optimised by utilising the data gather from the study

726943640 Page 3 of 4

Tracerco Diagnostics TM Job data sheet

Optimisation & Control of Distillation Columns

15/04/2020

The separation of raw materials, products and by-products are at the heart of the modern Chemical facility and that is why Tracerco have developed a range of process diagnostic services and specialist measurement products to help our customers optimise their distillation columns. These services and products allow our customers maximise the production through their columns whilst minimising downtime. The techniques and equipment below are all non-intrusive and provide real time data for our customers.

TRACERCO

Diagnostics™

ThruVision

The use of the TRACERCO Diagnostics™

ThruVision tomography system provides a powerful non-intrusive inspection tool to examine the contents of pipelines and vessels across a wide range of process industries.

TRACERCO

Diagnostics™

RapidScan

The TRACERCO Diagnostics™ RapidScan technology combines sophisticated wireless detector capability with an easy to install permanent guide wire scanning system.

TRACERCO

Diagnostics™ -

Tower Scan

The TRACERCO Diagnostic™ - Tower Scan allows are customers to verify the mechanical integrity of the internals and the process conditions that exist within the column to be verified.

TRACERCO

Diagnostics™ -

Distribution Study

The TRACERCO Diagnostic™ - Distribution Study allows are customers to fully understand the distribution conditions within their packed bed distillation column, enabling optimisation to be undertaken.

TRACERCO

Diagnostics™ -

Scan

The TRACERCO Diagnostic™ - Scan enables the process conditions within the down-comers of the column and the feed lines to the column to be assessed for liquid / gas / solid build-up. Click here for a brochure

TRACERCO™ -

Instruments

A range of leading edge instruments which allows our to measure and control the process conditions which exist within their distillation column.

726943640 Page 4 of 4

Download