Polymer
Conduit
®
Nick Break Test
Blue Polymer Conduit
Known throughout the industry for its longevity and low friction coefficient, this durable
conduit has proven to outlast metal lined
products while still providing as much as 4
pounds (1.81kg) less pull on the feed motor.
It’s your first choice for stationary, slightly
moving feed units or any application requiring 15 ft (4.57m) or longer wire runs.
Proven to have less friction than any other polymer conduit available
Greater stem strength prevents the conduit from drooping; Less pull
on the feed motor
Wire Wizard® EC-4 Conduit
Extremely durable for longer service life - will not fray, crack, or kink
Available in bulk or pre-cut lengths
Competitor A: Light Blue Conduit (A-2050)
Each piece of conduit
was nicked to simulate
the effect of being cut
by a sharp object in the
work environment
See friction coefficient test results on back page
Competitor B: Purple Conduit (PC-7)
5750 Marathon Drive • Jackson, MI 49201 • (517) 782-8040 • Fax (517) 782-8039
www.wire-wizard.com
Conduit Friction Test Results
Wire Wizard® EC-4 Polymer Conduit Test Results
Wire Wizard® Conduit Testing Station
Each test was performed on the conduit testing
station using .035 steel wire pulled through
approx. 15 ft of conduit in a circular loop.
LOAD UNITS: LB
X-Scale Settings (Time [sec.]):
Minimum: 0.000
Maximum: 89.000
Statistics:
Maximum: 0.64
Minimum: 0.40
Average: 0.49
Area Under Curve: 43.96
Competitor A: Lt. Blue (A-2050) Test Results
Competitor B: Purple (PC-7) Test Results
LOAD UNITS: LB
LOAD UNITS: LB
X-Scale Settings (Time [sec.]):
Minimum: 0.000
Maximum: 89.000
Statistics:
Maximum: 1.00
Minimum: 0.70
Average: 0.88
Area Under Curve: 77.98
X-Scale Settings (Time [sec.]):
Minimum: 0.000
Maximum: 89.000
Statistics:
Maximum: 0.92
Minimum: 0.58
Average: 0.74
Area Under Curve: 65.84