KEITH PANEL SYSTEMS S Y S T E M D E T A I L S FUNDERMAX- MAX EXTERIOR EXPOSED FASTENER PRESSURE EQUALIZED WALL SYSTEM KEITH PANEL SYSTEMS PAGE TITLE PAGE Table of Contents 1 Fundermax Max Exterior Product Information 2 Design and Installation Information 3, 4 Sample Elevation 5 Typical Vertical Joint 6 Outside Corner 7 Inside Corner 8 Window Jamb 9 Typical Horizontal Joint 10 Mid-panel Fastener Support 11 Base 12 Window Sill 13 Window Head 14 Floor Slab Deflection and Thru-wall Flashing 15 Parapet 16 TABLE OF CONTENTS 1 OF 16 KEITH PANEL SYSTEMS Test Method TECHNICAL DATA 1.35 g/cm3 EN ISO 1183-1 80 MPa EN ISO 178 ~9000 MPa EN ISO 178 60 MPa EN ISO 527-2 18x10-6 1K DIN 52328 Euroclass B-s2, d0 for 6-10mm EN 13501-1 Density Flexural Strength Modulus of Elasticity Tensile Strength Thermal Expansion Coefficient Fire Behavior Weight - 8mm (5 16") PANEL SIZES thickness ~10.8 kg/m² ~2.21 lbs/ft² imperial values GR 2800 x 1300 110" x 51" SP 2800 x 1854 110" x 73" JU 4100 x 1300 161" x 51" XL 4100 x 1854 161" x 73" Tolerances +10mm -0mm (EN 438-6,5.3) Panel formats are production formats. If exact dimensions and angles are necessary, we recommend an all-sided blank. Edge Processing To mill bevels electric hand planes with bevel or bevel grooves can be used or hand routers. Expansion / Contraction Max Exterior shrinks when it loses moisture and expands when it absorbs moisture. Calculate: overall length ÷ 500 = change in length Curved Max Exterior Panels Top and bottom edge profiles (2mm thick) must be pre-bent. Only sliding line fastenings are allowed (no point fastenings). The straight ends and joints of the exterior panels must likewise be edged. (U-profile, H-profile). Min. radius 3m(9'-10") and min. length 1.3m(4'-3"). Sealent The use of sealant compounds must be avoided as they can cause permanent staining to Max Exterior panels. MAX EXTERIOR PRODUCT INFORMATION 2 OF 16 KEITH PANEL SYSTEMS Panel Joints To be minimum 8mm wide for vertical and horizontal joints. The wider any joint, the less noticeable are inaccuracies in width. Therefore typical joint width used is 13mm. Panel Attachment Layout Spacing of rivet fasteners to be spread equally on panel. See below for edge distance and spacing requirements. Ventilaton Cavity The effectiveness of a pressure equalized system depends on a clear minimum air cavity depth as determined by building height. The cavity may not be reduced by horizontal profiles or any stray objects such as loose wind proofing layers, etc... Minimum cavity thickness as per table below: Height of wall system between cavity intake and exhaust Min. uninterrupted ventilated cavity up to 6m (18') 20mm (13 16") up to 25m (75') 30mm (13 16") up to 50m (150') 40mm (19 16") up to 75m (225') 50mm (2") > than 75m (225') 60mm (23 8") Single span panel. Ventilation Cavity Intake/Exhaust Air cavity ventilation openings provided at the base and top of the wall area and at any additional interruptions for example window heads and sills. Panel Attachment For fixing onto aluminum subframe, use Fundermax specified aluminum rivets. For fixing onto steel subframe, use Fundermax specified stainless steel rivets. Rivet saucer head is 15mm Ø painted corresponding colour with Max Exterior panel. A EPDM washer gasket is placed under rivet head to provide weather seal. For wood subframe stainless steel screws will be provided. Double span panel. Minimum distance to panel edge: Horizontal and Vertical = 20mm (13 16") Maximum distance to panel edge: Horizontal and Vertical = 80mm (318") Engineering Loads Max Exterior 8mm thickness fastener spacings Single span 0.50 kN/m² 1.00 kN/m² 1.50 kN/m² 2.00 kN/m² A = 700mm (27.5") B = 700mm (27.5") A = 539mm (21.2") B = 700mm (27.5") A = 373mm (14.7") B = 700mm (27.5") A = 280mm (11.0") B = 700mm (27.5") DESIGN AND INSTALLATION INFORMATION Double span A = 700mm (27.5") B = 700mm (27.5") A = 399mm (15.7") B = 700mm (27.5") A = 320mm (12.6") B = 700mm (27.5") A = 293mm (11.5") B = 700mm (27.5") 3 OF 16 KEITH PANEL SYSTEMS Max Exterior Panel Expansion/Contraction To allow expansion and contraction between the substructure and panels, all holes drilled in Max Exterior are oversized from the rivets body diameter. In order to hold up the panel, 1 rivet per panel is fixed by infilling the oversized hole with an aluminum or stainless steel sleeve. In addition to the fixed point, a loose point is placed in the same level. Position of the fixed and loose points will be determined on shop drawings. Site Fabricating Panels Avoid using tools which produce fine dust. Always work out of the weather. Always drill/cut perpendicularly to the panel surface. Use circular saw with straight edge with dust extraction. For best cut use a Blad hard metal teeth TF or diamond tipped saw blade. Use jig say for hole cut outs in panel. Dust from fabrication must be removed from panel surface immediately following cutting. Site Storage Max Exterior panels must be stacked horizontally on flat, stable supports and supporting panels. The goods must lie completely flat. Cover plates must always be left on the stack. The top cover should be weighted down. After removal of panels, PE films must again be closed over tyhe stack. The same applies, in principle, for cut-panel stacks. Incorrect storage can lead to permanent deformation of the panels. Max Exterior panels are to be stored in closed rooms under normal climatic conditions. Climate differences on the two surfaces of a panel are to be avoided. With pre-installed fastening elements, therefore, care is to be taken that the climatic effect is uniform on all sides. Use intermediate layers of wood or plastic. DESIGN AND INSTALLATION INFORMATION 4 OF 16 KEITH PANEL SYSTEMS SAMPLE ELEVATION 5 OF 16 KEITH PANEL SYSTEMS TYPICAL VERTICAL JOINT 6 OF 16 KEITH PANEL SYSTEMS OUTSIDE CORNER 7 OF 16 KEITH PANEL SYSTEMS INSIDE CORNER 8 OF 16 KEITH PANEL SYSTEMS WINDOW JAMB 9 OF 16 KEITH PANEL SYSTEMS TYPICAL HORIZONTAL JOINT 10 OF 16 KEITH PANEL SYSTEMS MID-PANEL FASTENER SUPPORT 11 OF 16 KEITH PANEL SYSTEMS BASE 12 OF 16 KEITH PANEL SYSTEMS WINDOW SILL 13 OF 16 KEITH PANEL SYSTEMS WINDOW HEAD 14 OF 16 KEITH PANEL SYSTEMS FLOOR SLAB DEFLECTION & THRU-WALL FLASHING 15 OF 16 KEITH PANEL SYSTEMS PARAPET 16 OF 16