<<Contents>> <<Index>> General Specifications GS 04M01B01-11E Data Acquisition Unit DA100 Main unit —stand-alone type (style number:S10) —expandable type (style number:S10) Sub units —DS400/DS600 (style number:S10) The following product was discontinued as of March, 2013. Refer to the following cautionary notes before you configure your system. Discontinued products: DA100-2 Data Acquisition Unit (Expandable Model) DARWIN is a system comprising a number of dataacquisition equipment components. In the course of system growth, new models, software, various input/output modules and optional features are added to the family to enhance the systems expandability and flexibility.You can check the versions of your equipment and software by referring to the style number:Sn* shown on the nameplate of the main unit. When configuring a system, you must confirm that the style number of each component unit and software meets the following requirements: * release number in the case of software:Rn 5.27 5.27 5.29 5.29 5.33 5.46 5.33 5.46 4.98 4.98 5.21 5.21 5.46 5.46 5.15 5.14 5.15 5.14 5.38 5.38 5.00 5.00 5.25 5.25 5.07 5.07 STATUS DATA ACQUISITION UNIT stand-alone type (1) The style number of each input/output module must be the same as or lower than that of the main unit or sub-unit to which the module is connected. (2) The release number of a dedicated software package must be the same as or higher than the style number of the main unit or sub-unit where the package is installed and where it performs control. Any equipment/software not meeting these requirements is incompatible with your system configuration. For information on how to upgrade to compatible equipment/software, consult our sales personnel. 5.27 5.29 5.27 5.29 5.33 5.46 4.98 5.21 5.33 5.46 4.98 5.21 5.46 5.15 5.14 5.38 5.46 5.15 5.14 5.38 5.00 5.25 5.07 5.00 5.25 5.07 STATUS STATUS SUB UNIT DATA ACQUISITION UNIT expandable type DA100 Data acquisition unit Model DA100 stand-alone type Integrated type capable of measuring data from up to 40 channels. Can be carried about easily and is suitable for small scale data logging. The number of channels can be increased from 10 to 40 Increasing number of channels in a module steps, and also the kinds of inputs input channels, changing kinds of inputs can be changed. Kinds of inputs Universal, DC V/TC/DI, mA, power monitor, strain, Pulse, DI Input and output modules Input modules, communication module, DI/DO module, that can be connected to alarm output modules, retransmission modules the main unit Connection of sub units, Not applicable and remote measurement distance Input and output modules Not applicable that can be connected to the sub units Max scanning speed All channels/0.5 sec Features DA100 expandable type Can be expanded up to 300 channels. You can perform multi-channel measurement with the minimum of wiring by connecting sub units to the main unit with dedicated cable. The number of channels can be increased from 10 to 300 channels in a module steps, and also the kinds of inputs can be changed. Universal, DC V/TC/DI, mA, power monitor, strain, Pulse, DI (Input modules are connected to the sub units.) Communications module, DI/DO module, alarm output modules Up to 6 units, 500 m max (Full extension) Input modules, DI/DO module, alarm output module , retransmission modules All channels/0.5 sec GS 04M01B01-11E © Copyright November 1995 (YK) 13th Edition: Aug. 2013 (KP) <<Contents>> <<Index>> Outline of the stand-alone type Main features The DA100 data acquisition unit (stand-alone type) measures input signals from between 10 and 40 channels, and transfers the measured data in realtime to a personal computer. This highly portable unit is also suitable for on-site data logging. (1) Compact: Occupies only 1/5 of the volume of other Yokogawa units. (Comparison between a system consisting of the DA100 main unit + one sub unit and a system consisting of one DA2500E + one remote scanner) (2) High speed: Can measure data from 300 channels at 0.5-second intervals maximum. (3) A wide range of inputs: Universal (DC voltage, thermocouple, RTD, contact), DC voltage/ thermocouple/contact dedicated inputs, mA, power monitor, strain, pulse, DI input. (4) Remote measurement: The sub unit is designed to be connected to the main unit with dedicated cable, enabling it to be located up to 500 m away from the main unit. DA100 stand-alone type main unit + PC 5.27 5.27 5.29 5.29 5.33 5.46 5.33 5.46 4.98 4.98 5.21 5.21 5.46 5.46 5.15 5.14 5.15 5.14 5.38 5.38 5.00 5.00 5.25 5.25 5.07 5.07 STATUS DATA ACQUISITION UNIT Outline of functions Main features (1) Compact: Occupies only 1/5 of the space of Yokogawa’s remote scanner for the DA2500E. (2) High speed: Can measure data from 40 channels in 0.5 second maximum. (3) A wide range of inputs: Universal (DC voltage, thermocouple, RTD, contact), DC voltage/ thermocouple/contact dedicated inputs, mA, power monitor, strain, pulse, DI input. Outline of functions (1) Setting and control of connected input/output modules (2) The measured results obtained using input modules can be transferred to a personal computer via a GP-IB, RS-232-C, RS-422A/RS-485, Ethernet communications interface. Outline of expandable type The main unit of the DA100 data acquisition unit (expandable type) can be connected to DS400 (4-slot type) or DS600 (6-slot type) sub units containing various input modules, in order to configure a system that can acquire data from a maximum of 300 channels. The measured data is transferred in realtime to a personal computer. (1) Setting and control of input/output modules on the sub units connected with dedicated cable (Setting is done using the connected personal computer and the setting software provided.) (2) Control of alarm output modules, DI/DO modules, communication interface modules connected to the DA100 main unit. (3) Acquisition by the DA100 main unit of the measured results from the input modules, via the sub units. (4) Transfer of the measured results acquired by the DA100 main unit to a personal computer, via a GP-IB, RS-232-C, or RS-422-A/RS485, and Ethernet communication interfaces. Outline of sub units The DS400/DS600 sub unit functions as an interface between the expandable version of the DA100 data acquisition and the various input/ output modules to which it is connected. A maximum of four input and output modules of various kinds (4 slots) can be connected to the DS400, and a maximum of six input and output modules (6 slots) can be connected to the DS600. A maximum of six sub units can be connected to one main unit. Both DS400 and DS600 sub units can be connected to the same main unit. The main unit can be connected to the sub units, or the sub units to each other, with dedicated cable, enabling them to be separated by up to 500 m. The sub units have excellent environmental toughness and can be installed very easily, enabling them to be installed over a wide area without environmental restrictions. Outline of functions DA100 expandable type main unit + sub unit + PC 5.27 5.29 5.33 5.46 4.98 5.27 5.29 5.33 5.46 4.98 5.21 5.46 5.15 5.14 5.38 5.21 5.46 5.15 5.14 5.38 5.00 5.25 5.07 5.00 5.25 5.07 (1) Setting and control of the connected input/output modules (by means of commands from the DA100 main unit.) (2) Measured values output to the DA100 main unit . STATUS STATUS SUB UNIT DATA ACQUISITION UNIT 2 GS 04M01B01-11E <<Contents>> <<Index>> ■ Configuration DA100 expandable type: Expandable type main unit + sub units (DS400 or DS600) + various input/output modules + communication interface + data acquisition software Component units Available module groups b -/B -/A CH1 b -/B -/A CH1 CH2 b CH2 CH3 CH4 CH3 CH5 CH4 CH6 CH5 CH7 CH6 CH8 CH7 CH3 STATUS CH4 CH5 CH6 CH7 CH9 CH10 DATA ACQUISI TION CH8 CH9 -/B -/A CH1 CH2 UNIT CH8 CH10 CH9 POWER CH10 100-240V AC 50/6 0Hz 70VA MAX DA100 main unit stand-alone type NO C ALM1 NO C ALM2 ALM1 ALM3 ALM2 ALM4 ALM3 ALM5 ALM4 ALM6 ALM5 The DA100 data acquisition unit can be freely configured for different functions by selecting modules from the following module groups and connecting them to the main or sub units. Input modules: Universal (DC voltage, thermocouple, RTD, contact), DC voltage/ thermocouple/contact dedicated input modules, mA, power monitor, strain, pulse, DI input. Alarm modules: 4 point out put (transfer contact) or 10 point out put (make contact) (The number of alarm channels can be increased in module units.) Communications modules: Select one type from GP-IB, RS-232-C, RS-422-A/RS-485, Ethernet. DI/DO modules: Alarm 2-point output (transfer contact), fail output, command DO, remote control signal input. Retransmission modules: Re-output of measured values and computed results. STATUS ALM7 NOTE ALM6 ALM8 ALM7 ALM9 DATA ACQUISI TION ALM8 ALM10 Refer to “Standard connection modules” in GS 04M01E01-11E, or GS 04M01E01-50E for detailed specifications of the above modules. UNIT ALM9 ALM10 POWER 100-240V AC 50/6 0Hz 70VA MAX DA100 main unit expandable type Package software • DARWIN DAQ 32 (Standard Package) • DARWIN DAQ 32 Plus (Optional Package) General b DAQ 32 and DAQ 32 Plus are software packages developed by YOKOGAWA specially for the DARWIN series. These packages run on a personal computer, achieving highly dependable data acquisition using DARWIN series units (DA100, DC100, DR130, DR230, and DR240) and superb operability. The main differences between the two packages are in the monitoring functions. The DAQ 32 only offers two display formats - waveform trend and digital; has 2 groups of 10 channels/ window; and does not support alarm display. If simultaneous multi point monitoring or more flexible display forms of data such as level meter, analog meter, and thermometer faceplates, and alarm indications are required, use the optional DAQ 32 Plus. -/B -/A CH1 b -/B -/A CH1 CH2 b CH2 CH3 -/B -/A CH1 b CH4 CH3 CH5 CH4 CH6 CH5 CH7 CH6 CH8 CH7 STATUS CH3 CH4 CH4 CH5 CH5 CH6 SUB CH10 UNIT CH6 CH7 CH9 CH10 CH2 CH3 CH8 CH9 -/B -/A CH1 CH2 CH8 CH7 CH9 CH8 CH9 CH10 POWER CH10 100-240V AC 50/6 0Hz 70VA MAX DS400 sub unit b -/B -/A CH1 CH2 CH3 CH4 CH5 CH6 CH7 CH8 CH9 CH10 b -/B -/A CH1 b CH2 -/B -/A CH1 b CH3 CH2 -/B -/A CH1 b CH4 CH3 CH5 CH4 CH6 CH5 CH7 CH6 CH8 CH7 CH9 CH10 CH8 CH9 CH10 CH2 CH3 -/B -/A CH1 CH2 STATUS CH4 CH5 CH6 CH7 CH3 CH4 CH5 SUB CH7 CH9 CH8 CH10 UNIT CH6 CH8 CH9 POWER CH10 100-240V AC 50/6 0Hz 70VA MAX DS600 sub unit Unit configuration The DA100 comes in the following two types, each of which is intended to be set and controlled by a personal computer via a general purpose communications interface. DA100 stand-alone type: Stand-alone type main unit + various input/output modules + communication interface modules + data acquisiton software GS 04M01B01-11E 3 4 Alarm output module I/O module Input DI/DO module Module 1-5 V module DC V DARWIN DAQ 32 4-20 mA module Retransmission module Set-up and control software DA100 stand-alone type system configuration TC Universal DC V/TC/DI module DARWIN DAQ 32 Plus package software DI module RTD DAQLOGGER CH4 CH3 CH2 CH1 CH6 CH5 b -/B -/A Power module CH10 CH9 CH8 CH7 No alarm module or DI/DO module can beconnected to theright side of this input module. CH1 CH2 CH10 CH9 CH8 CH7 CH6 CH5 CH4 CH3 b -/B -/A Contact Status Input module Pulse module Install CH1 CH2 CH10 CH9 CH8 CH7 CH6 CH5 CH4 CH3 b -/B -/A ACQUIS ITION UNIT 100-240V AC 50/60Hz POWER Strain module DATA STATUS 70VA AC ~ MAX Communication interface cable mA(current) module current A GP-IB module DA100 main unit Personal computer PULSE RS-232-C module RS-422-A/485 module Communication interface module STRAIN Ethernet module <<Contents>> <<Index>> GS 04M01B01-11E GS 04M01B01-11E Alarm output module DI/DO module Input I/O module Module DARWIN DAQ 32 DCV 1-5 V module 4-20 mA module Retransmission module Sub unit Set-up and control software TC Extension module Remote measurement DARWIN DAQ 32 Plus package software RTD Universal DC V/TC/DI module DAQLOGGER Install DI module NO C ALM1 ALM2 NO C ALM10 ALM9 ALM8 ALM7 ALM6 ALM5 ALM4 ALM3 DATA Contact Status VAC UNIT 50/60Hz ITION MAX AC ~ Pulse input module current A Strain module DA100 main unit Personal computer Dedicated cable (up to 500 m) 70VA mA(current) module 100-240 POWER ACQUIS STATUS Communication interface cable Input module Power module ALM10 ALM9 ALM8 ALM7 ALM6 ALM5 ALM4 ALM3 ALM2 ALM1 No alarm module or DI/DO module can beconnected to theright side of this input module. DA100 expandable type system configuration PULSE GP-IB module RS-232-C module STRAIN RS-422-A/485 module Communication interface module Sub unit Ethernet module <<Contents>> <<Index>> 5 <<Contents>> <<Index>> ■ Connecting modules Connecting modules to the stand-alone type Modules that can be connected Input modules: Universal (DC voltage, thermocouple, RTD, contact), DC voltage/ thermocouple/contact dedicated, mA, power monitor, strain, pluse, DI input modules Alarm modules: 4 channels (transfer contact) or 10 channels (make contact) (The number of alarm channels can be increased in module units.) Communications modules: Select one type from GP-IB, RS-232-C, RS-422-A/RS-485, Ethernet DI/DO modules: Alarm 2-point output (transfer contact), fail output, command DO, remote control signal input Retransmission modules: Re-output of measured values and computed results Extension module: For remote measurment Definition of number of connections • • • • • • • • • A maximum of six modules can be connected to the main unit. One of these must always be a communications module. The number of DI/DO modules must be no greater than one. The alarm output module, DI/DO module, and retrandmission module must be connected on the left side of the input modules. Number of input modules ≤ 4 Number of input modules + number of alarm modules + DI/DO module + communications module ≤ 6 One extension module can be connect to the main unit Number of retransmission modules ≤ 4 The standard operating temperature and humidity are different for each module type. Therefore,always make sure to verify this when connecting the module. Connecting modules to the expandable type Modules that can be connected Main unit Alarm modules: 4-point output (transfer contact) or 10-point output (make contact) (The number of alarm channels can be increased in module units.) Communications modules: Select one type from GP-IB, RS-232-C, RS-422-A/RS-485, Ethernet DI/DO modules: Alarm 2-point output (transfer contact), fail output, command DO, remote control signal input. Sub unit DS400/DS600 Input modules: Universal (DC voltage, thermocouple, RTD, contact), DC voltage, thermocouple, contact dedicated input modules, pulse Alarm modules: 4-point output (transfer contact) or 10-point output (make contact) (The number of alarm channels can be increased in module units.) DI/DO modules: Alarm 2-point output (transfer contact), fail output, command DO modules and remote control signal input Extension module: For remote measurment Retransmission modules: Re-output of measured values and computed results 6 Definition of number of connections for the expandable type DA100 main unit: • The number of input modules and retransmission modules is 0. Also, 1 communications module must always be connected. • Number of alarm modules + DI/DO module ≤ 3 Sub unit DS400: • The maximum number of modules per slot that can be connected is 4. • Number of input modules + DI/DO module + alarm modules + retransmission modules ≤ 4 Sub unit DS600: • The maximum number of modules per slot that can be connected is 6. • Number of input modules + DI/DO module + alarm modules + retransmission modules ≤ 6 Common to all: • One DI/DO module can be connected to one expandable type system • The alarm output module and DI/DO module must be connected on the left side of the input modules. • One extension module can be connected to one sub unit. • The retransmission module can be connected to the sub unit only. Up to 30 modules. • The standard operating temperature and humidity are different for each module type. Therefore, always make sure to verify this when connecting the module. Method of connecting modules The standared operating temperature and humidity are different for each module type. Therefore, always make sure to verify these when connecting the module. Stand-alone type: Connect directly to the main unit. The alarm output modlues and DI/DO module must be connected on the left side of the input modules. Expandable type: Connect the input modules, retransmission modules, or extension module directly to the sub unit. (You cannot connect these modules directly to the main unit.) Connect the alarm modules, communications module and DI/DO module directly to the main unit. The alarm output modlues and DI/DO module must be connected on the left side of the input modules. Connecting sub units Kinds of sub units (type name): DS400 sub unit: For 4 slots DS600 sub unit: For 6 slots Number of sub units to be connected: Stand-alone type:Cannot be connected. Expandable type: A maximum of six sub units can be connected. (This also applies when 4-slot sub units and 6-slot sub units are connected to the same main unit.) Method of connecting sub units: A sub unit can be connected to either the main unit or another sub unit with dedicated cable. Maximum total extension length is 500 m. GS 04M01B01-11E <<Contents>> <<Index>> ■ Standard specifications General specifications Construction Installation method: Floor mounting: Use the stand at the bottom of each unit. Direct panel mounting: Screw the unit directly to the panel at the specified points. Rack mounting: Use the dedicated mounting brackets. (Regardless of which mounting method you use, be sure to install the units in an upright position.) Materials: Steel plate, aluminum castings, plastic moldings Paint color: Base unit: Modules: Lamp black (equivalent to Munsell 0.8Y2.5/0.4) Slate gray light (equivalent to Munsell 0.1PB4.6/ 0.2) Slate gray light (equivalent to Munsell 0.1PB4.6/ 0.2) External dimensions: Stand-alone type main unit: Approx. 422 (W) × 176 (H) × 100 (D) mm Expandable type main unit: Approx. 336 (W) × 165 (H) × 100 (D) mm DS400 sub unit: Approx. 336 (W) × 165 (H) × 100 (D) mm DS600 sub unit: Approx. 422 (W) × 176 (H) × 100 (D) mm Weight: Stand-alone type main unit: Approx. 3.5 kg (with 4 input modules + 1 alarm output module + 1 communications module installed) Approx. 1.1 kg* Expandable type main unit: Approx. 2.5 kg (with 4 input/output modules installed) Approx. 0.9 kg* DS400 sub unit: Approx. 2.5 kg (with 4 input/output modules installed) Approx. 0.9 kg* DS600 sub unit: Approx. 3.5 kg (with 6 input/output modules installed) Approx. 1.1 kg* *: is the weight of each unit without modules installed. Input Measurement range: NOTE Refer to “Standard connection modules” in GS 04M01E01-11E for detailed specifications of the measurement range. Measurement interval: Selectable from 0.5, 1, 2, 3, 4, 5, 6, 10, 12, 15, 20, 30, and 60 sec depending on the minimum measurement interval (when modules with different minimum intervals are installed together, the measurement interval is determined by whichever module has the maximum interval). Stand-alone type: Max 40 channels/500 ms (when the software provided is used) Expandable type: Max 300 channels/500 ms (when the software provided is used) GS 04M01B01-11E A/D integration period (dependent on the module): Selectable from 20 ms (50 Hz), 16.7 ms (60 Hz), 100 ms (10 Hz), and auto switching (unavailable for a DC power supply model). Alarm Number of settings: Up to four settings can be made for each channel. Kinds of alarms: Selection from higher limit, lower limit, difference higher limit, difference lower limit, higher limit of rate of change, lower limit of rate of change. Rate of change alarm time interval: Can be set to measurement interval × 1 to 15 (common to both rising and falling limits) Output mode: Excitation/non-excitation selection, AND/OR mode selection, and output hold/non-hold specification can be made. (common to all channels) Six reflash alarm output contacts can be specified. Number of alarm output points: Stand-alone type: 2 points (DI/DO module) to 40 points max Expandable type: Up to 30 points can be connected to the DA100 main unit (the number of alarm points can be increased in module units) By connecting sub units, (the number of alarm points can be increased in module units). Number of alarm output modules that can be connected: Stand-alone type: The number of alarm points can be increased in module units. Expandable type: Up to 3 modules can be connected to the DA100 main unit, up to 6 modules can be connected to one sub unit, and up to 4 modules can be connected to one subunit. Standard computation functions Computation functions: Difference between arbitrary channels, linear scaling, moving average Scaling: Ranges for which scaling can be done: DC voltage, thermocouple, RTD, contact, strain, mA, Scaling range: –30000 to +30000 Decimal point: Can be set freely. Measurement accuracy for scaling: Measurement accuracy for scaling (digits) = Measurement accuracy (digits) × Scaling span (digits)/Measurement span (digits) + 2 digits (Numbers below the decimal point are rounded up.) Moving average: The moving average results for between 2 to 64 scans are computed. Communications functions Communication modules: GP-IB, RS-232-C, RS-422-A/RS-485, Ethernet communications interface modules 7 <<Contents>> <<Index>> Output functions DI/DO module: Internal alarm output 2 points, fail output function, command Do. Retransmission modules: Re-output of measured values and computed results. 10 voltage and 2 current channels. AC power supply section Rated supply voltage: 100 to 240 VAC (free supply voltage selection) Usable supply voltage range: 90 to 250 VAC Rated supply frequency: 50/60 Hz Power consumption: Stand-alone type main unit (when 6 connectable modules are installed) max approx. 55 VA (when 100 VAC is input) max approx. 70 VA (when 240 VAC is input) Expandable type main unit (when 4 connectable modules are installed) max approx. 45 VA (when 100 VAC is input) max approx. 55 VA (when 240 VAC is input) DS400 sub unit (when 4 connectable input/output modules are installed) max approx. 45VA (when 100 VAC is input) max approx. 55 VA (when 240 VAC is input) DS600 sub unit (When 6 connectable input/output modules are installed) max approx. 55 VA (when 100 VAC is input) max approx. 70 VA (when 240 VAC is input) DC power Supply section (DC power supply only, Specify when ordering) Rated supply voltage: 12 to 28 VDC Usable supply voltage range: 10 to 32 VDC Power consumption: Approx. 25 VA max. Terminal: Dedicated connector Other: Automatic selection of A/D integral period does not function. AC Adapter (for DC power supply model only, optional accessary) Rated supply voltage: 100 to 240 VAC Usable supply voltage range: 90 to 250 VAC Rated supply frequency: 50/60 Hz Power consumption: max. 90 VA Others Clock: With calendar function (Western calendar). Clock accuracy: ±100 ppm System alarm: Contact output (when DI/DO module is connected) Set value backup: Lithium battery backup (approx. 10 years), excluding clock function Insulation resistance: At least 20 MΩ between each terminal and ground (measured with 500 VDC) 8 Withstand voltage: Between AC power supply terminal and case of DA100 main unit:1500 VAC (50/60 Hz) for one minute Between DC power supply terminal and case of DA100 main unit:1000 VAC (50/60 Hz) for one minute Between input terminal and case of DA100 main unit:1500 VAC (50/60 Hz) for one minute Between output terminal and case of DA100 main unit:2300 VAC (50/60 Hz) for one minute Normal operation conditions Supply voltage: 90 to 250 VAC, 10 to 32 VDC Supply frequency:50 Hz ± 2%, 60 Hz ± 2% Ambient temperature: Stand-alone type main unit Expandable type main unit When floor-mounted and Desk top : 0 to 50˚C When panel-mounted : 0 to 50˚C When Rack-mounted : 0 to 50˚C DS400/DS600 sub unit When floor-mounted and Desk top : -10 to 50˚C When panel-mounted : -10 to 60˚C When Rack-mounted : -10 to 50˚C When DC power operation : 0 to 50˚C Ambient humidity: Temperature Humidity –10 to 40°C 20 to 80% RH 40 to 50°C 10 to 50% RH 50 to 60°C 5 to 30% RH * no ice formation 10 to 60 Hz 0.2 m/s2 Not allowed 400 A/m max (50/60 Hz) Mount the unit left-right horizontally or vertically, as a general rule. Installation location: Room Installation height: Altitude up to 2,000 m Installation category: II (according to CSA22.2 No.1010.1) Measurement category: II (according to IEC61010-1) Degree of pollution: 2 Warm-up time: At least 30 minutes after power switch-on Vibration: Shock: Magnetic field: Position: Standard performance Measurement accuracy: Reference operation state: 23 ± 2°C, 55 ± 10% RH, supply voltage: 90 to 250 VAC, supply frequency: 50/60 Hz ± 1%, Warmup: At least 30 minutes; When operating, the system must not adversely affect the operation of other measuring instruments by generating vibration, for example. enerating vibration, for example. NOTE Refer to “Standard connection modules” in GS 04M01E01-11E for detailed specifications of the measurement accuracy. GS 04M01B01-11E <<Contents>> <<Index>> Effect of Operation Conditions Ambient temperature: Variation for a temperature change of 10°C within ±(0.1% of rdg + 1 digit) ±(0.2% of span + 1 digit) for Cu 10 Ω Voltage variation: Within ±1 digit over the range of 90 to 132, or 180 to 250 VAC (frequency 50/60 Hz) External magnetic field: Variation with respect to AC (50/60 Hz) and DC magnetic fields of 400 A/m ... Within ±(0.1% of rdg + 10 digits) Radio wave: Within ±(1% of span) at 1 m from 150 MHz or 460 MHz field Signal source resistance: Variation with respect to signal source resistance + 1 kΩ change (1) Voltage 2 V range or below ... Within ±10 µV 6 V range or above ... Within ±0.1% of rdg (2) Thermocouple Within ±10 µV; However, it must be within ±100 µ when burnout is specified. (3) RTD Variation with respect to change of 10 Ω per wire (when all three wires are the same resistance value) Indication ... Within ±(0.1% of rdg + 1 digit) Variation in indication with respect to a difference of 40 mΩ in the resistance between conductors (max difference between 3 wires) ... Approx. 0.1°C Mounting position: Variation when the unit is mounted horizontally on a panel ... Within ±(0.1% of rdg + 1 digit) excluding RJC error Vibration: Variation when sinusoidal vibration of acceleration 0.2 m/s2 is applied for 2 hours in each of the 3 axial directions over a frequency range of 10 to 60 Hz ... Within ±(0.1% of rdg + 1 digit) Transportation and storage conditions These refer to the environmental conditions existing during transportation and storage from the time of shipment from the factory until commencement of use, and also during transportation and storage in the case of a temporary period of non-use. If the environmental conditions are maintained within the specified range, the unit will not incur permanent damage, and can be returned to a normal working condition (re-adjustment may be required in some cases). Ambient temperature: –25 to 60°C Humidity: 5 to 95% RH Vibration: 10 to 60 Hz 4.9 m/s2 max Shock: 392 m/s2 max (in packed condition) Supported standards Obtained CSA22.2 No.61010-1 Installation category (Overvoltage category): II, Degree of pollution: 2 Obtained UL No.61010-1 (CSA NRTL/C) UL CE marking was removed under the publication of the CE 3rd edition of IEC Standard. EN 55011 Class A, Group 1 C-Tick KC marking Electromagnetic wave interference prevention standard, electromagnetic wave protection standard compliance CSA GS 04M01B01-11E /M1: MATH Function Computation types Types: Four arithmetical operations, SQR (square root), ABS (absolute value), LOG (common logarithm), LN (natural logarithm), EXP (exponent), statistical computation*, logical computation (AND, OR, NOT, and XOR), relational computation, exponentiation, previously-measured value reference, hold**, reset, clear, and remote RJC. * Statistical computation CLOG: Computation process of simultaneously measured values within a group (total, maximum, minimum, average, and maximum - minimum) TLOG: Computation process of a specific channel over time axis (total, maximum, minimum, average, and maximum - minimum) Statistical computation interval: Set by the event/action function (effective when /M1 option is selected) **Temporary hold of the computed result Can be controlled by event/action function (such as remote control signal, time specified, and alarm status). (effective when /M1 option is selected) Number of channels for computing (Number of channels that can be allocated for computational purposes.): Stand-alone type: 30ch maximum Expandable type: 60ch maximum Computation interval: Every measurement interval (except when the computation becomes too difficult to be processed every measured interval, in which case an alarm is generated) Significant digits during computation: ±1038 Significant digits of the computed result: -9999999 to +99999999 (Decimal point can be set to have 1 to 4 digits on the right of the decimal point) Input from communication interface: Digital value (ASCII numerical array) input from the communication interface Computation start/stop: Can be controlled by communication commands and event/action function (such as remote control signal, time specified, and alarm status) Other functions included in the math function: Remote RJC Input type: Thermocouple (TC) Accuracy: (Twice the measurement accuracy of the standard thermocouple input) + (temperature difference between the terminal of the remote terminal section and thermocouple section for measuring the remote terminal temperature) Thermocouple burnout: not selectable /M3: Report Function Refer to the GS 04M01B01-31E 9 <<Contents>> <<Index>> Type name and specification code Data Acquisition Unit DA100 Model DA100 Type Suffix Code Data acquisition unit Stand-alone type -1 Expandable type -2 Software Power Supply Description Optional Code DARWIN DAQ 32 for IBM PC-AT 3 100 VAC to 240 VAC 12 VDC to 28 VDC (DC power supply only) -1 -2 (always specify Y for the power cable) Power Inlet & Power Cable D F 3-pin power inlet w/UL, CSA cable 3-pin power inlet w/VDE cable H 3-pin power inlet w/CCC cable R S 3-pin power inlet w/SAA cable 3-pin power inlet w/BS cable W 3-pin power inlet w/screw terminal /M1 Dedicated connector for DC power supply w/o power cable Math function (including RRJC) /M3 Report function /FC DARWIN DAQ 32 is supplied with floppy disks Optional Code Description 4 slots subunit for inputs and alarm output 6 slots subunit for inputs and alarm output Always-00 100 VAC to 240 VAC 12 VDC to 28 VDC (DC power supply only) (always specify Y for the power cable) 3-pin power inlet w/UL, CSA cable 3-pin power inlet w/VDE cable 3-pin power inlet w/CCC cable 3-pin power inlet w/SAA cable 3-pin power inlet w/BS cable 3-pin power inlet w/screw terminal Dedicated connector for DC power supply w/o power cable Y Optional Features Subunit DS400/DS600 Model DS400 DS600 Type Power Supply Suffix Code -00 Power Inlet & Power Cable 10 -1 -2 D F H R S W Y GS 04M01B01-11E <<Contents>> <<Index>> Input module Model Code DU100-11 DU100-21 DU100-31 DU100-12 DU100-22 DU100-32 DU200-11 DU200-21 DU200-31 DU200-12 DU200-22 DU200-32 DU300-11 DU300-12 DU400-12 DU400-22 DU500-12 DU500-13 DU500-14 DU600-11 DU700-11 Description 10ch universal input module (DCV/TC/DI & RTD) 20ch universal input module (DCV/TC/DI & RTD) 30ch universal input module (DCV/TC/DI & RTD) 10ch universal input module (DCV/TC/DI & RTD) 20ch universal input module (DCV/TC/DI & RTD) 30ch universal input module (DCV/TC/DI & RTD) 10ch DCV/TC/DI input module 20ch DCV/TC/DI input module 30ch DCV/TC/DI input module 10ch DCV/TC/DI input module 20ch DCV/TC/DI input module 30ch DCV/TC/DI input module 10ch mA input module 10ch mA input module Power monitor module for single phase Power monitor module for 3 phase 10ch strain input module (120 Ω) 10ch strain input module (350 Ω) 10ch strain input module (External bridge box) 10ch pulse input module 10ch DI input module Terminal Screw Screw Screw Clamp Clamp Clamp Screw Screw Screw Clamp Clamp Clamp Screw Clamp Clamp Clamp Clamp Clamp NDIS Screw Screw Other module Model Code DT100-11 DT200-11 DT200-21 DT300-11 DT300-21 DT300-31 DT300-41 DT500-11 DT500-21 GS 04M01B01-11E Description 2 alarm, 12 remote, fail/chart end Screw terminal 4 alarm relay output (transfer contacts) Screw terminal 10 alarm relay output (make contacts) Screw terminal GP-IB interface module RS-232-C interface module RS-422-A/RS-485 interface module Ethernet interface module 10 channels, 1-5 V output retransmission module 2 channels, 4-20 mA output retransmission module 11 <<Contents>> <<Index>> Accessories Model Code Description DV100-011 DV100-012 Extension module Extension base unit DV200-000 Extension cable (0.5 m) DV200-001 DV200-002 Extension cable (1 m) Extension cable (2 m) DC200-005 Extension cable (5 m) DV200-010 Extension cable (10 m) DV200-020 DV200-050 Extension cable (20 m) Extension cable (50 m) DV200-100 Extension cable (100 m) DV200-200 DV200-300 Extension cable (200 m) Extension cable (300 m) DV200-400 Extension cable (400 m) DV200-500 DV250-001 Extension cable (500 m) Cable adapter DV300-011 Shunt resistor 10 Ω for screw input terminal DV300-012 DV300-101 Shunt resistor 10 Ω for clamped input terminal Shunt resistor 100 Ω for screw input terminal DV300-102 Shunt resistor 100 Ω for clamped input terminal DV300-251 DV300-252 DV400-011 Shunt resistor 250 Ω for screw input terminal Shunt resistor 250 Ω for clamped input terminal Rack mount kit (DA100 exp./DS400) for ANSI DV400-012 DV450-001 DV500-001 Rack mount kit (DA100 stand./DS600) for ANSI Strain conversion cable AC adapter W/UL, CSA cable DV500-002 DV500-003 DV500-004 AC adapter W/VDE cable AC adapter W/SAA cable DV500-005 AC adapter W/BS cable AC adapter W/CCC cable Package software 12 Model Code DP120-13 WX102/CD1 Description DARWIN DAQ 32 software (Windows XP/Vista/7) (comes standard) DARWIN DAQ 32 Plus software (Windows 2000/XP/Vista/7) (optional) WX101/CD1 DAQLOGGER for multi-channel data logging software (Windows 2000/XP/Vista/7) (optional) GS 04M01B01-11E <<Contents>> <<Index>> Wiring Input Signal Lines (to Universal and DCV/TC/DI input modules) Terminals Screw type terminal b Clamp type terminal - + DC voltage • TC • contact B A RTD* CH1 CH2 *There are no RTD input terminals on the DCV/TC/DI input module. A + B b CH2 CH10 CH1 CH4 CH3 CH10 CH9 Wiring Diagram DC voltage input/DI input (contact) + DC input - + + DC voltage input - + DC current input - TC input - RTD input b B + Shunt resistor Note:For 4 to 20 mA input, shunt resistance value should be 250 Ω ± 0.1% A A b B Compensation lead 10 Ω* max./leadwire Three wire resistances should be approx. equal. *10 Ω max. for Pt 100 Ω and Pt 50 Ω, 1 Ω max. for Cu 10 Ω. Wiring Alarm Output SIgnal Lines (to DI/DO and Alarm output modules) Terminals NO Contact capacity: 250 VDC/0.1 A (with a resistor load) 250 VAC/2 A (with a resistor load) 30 VDC/2 A (with a resistor load) Fail output: becomes de-activated when an error is detected in the system. GS 04M01B01-11E C DT100-11 NC Fail output (transfer contact) Remote control input Can be used for event/action function only when the /M1 option of DA100 is specified. 1 2 Alarm output (transfer contact) NO C DT200-11 NC 1 2 Alarm output (transfer contact) NO C DT200-21 1 2 Alarm output (make contact) 3 4 Alarm output (transfer contact) 10 13 <<Contents>> <<Index>> Location and Location Number (Channel Number, Alarm Output Number, DI/DO Number) The location numbers correspond to channel numbers for locations where the input module is connected, to alarm output numbers for locations where the alarm output module is connected, and to DI/DO numbers for locations where the DI/DO module is connected. In case of the DA100 Stand-alone type The location numbers correspond to the location of each module as shown in the figure below. Module 5 (Location numbers:051 to 060) Module 4 (Location numbers:041 to 050) Module 3 (Location numbers:031 to 040) Module 2 (Location numbers:021 to 030) Module 1 (Location numbers:011 to 020) Module 0 (Location numbers:001 to 010) In case of the DA100 Expandable type The unit number (the number of the main unit is fixed at “I”) and location numbers correspond to the location of each module as shown in the figure below. Module 3 (Location numbers:131 to 140) Module 2 (Location numbers:121 to 130) Module 1 (Location numbers:111 to 120) Module 0 (Location numbers:101 to 110) Main unit Input modules cannot be connected. Unit No.:I Module 5 (Location numbers:051 to 060) Module 4 (Location numbers:041 to 050) Module 3 (Location numbers:031 to 040) Module 2 (Location numbers:021 to 030) Module 1 (Location numbers:011 to 020) Module 0 (Location numbers:001 to 010) Subunit DS600 Unit No.:0 Module 3 (Location numbers:131 to 140) Module 2 (Location numbers:121 to 130) Module 1 (Location numbers:111 to 120) Module 0 (Location numbers:101 to 110) Subunit DS400 Unit No.:1 14 GS 04M01B01-11E <<Contents>> <<Index>> ■ Name and Function of Each Part DA100 Stand-alone type (DA100-1) Installation holes Module connector Screw holes for module installation Status indicator Power switch Function grounding terminal (below power switch) Feet Power connector (when specifying W, changed to screw terminal) (when specifying Y, changed to dedicated connector) Holes for fastening the feet DA100 Expandable type (DA100-2) Module connector Lid covering the extension cable connector Status indicator Screw holes for module installation Power switch Function grounding terminal (below power switch) Feet Installation holes Power connector (when specifying W, changed to screw terminal) (when specifying Y, changed to dedicated connector) Holes for fastening the feet Subunit DS400 Module connector Lid covering the extension cable connector Switch to set the unit number Status indicator Screw holes for module installation Power switch Function grounding terminal (below power switch) Feet Installation holes Power connector (when specifying W, changed to screw terminal) (when specifying Y, changed to dedicated connector) Holes for fastening the feet GS 04M01B01-11E 15 <<Contents>> <<Index>> Subunit DS600 Installation holes Module connector Lid covering the extension cable connector Screw holes for module installation Status indicator Switch to set the unit number Power switch Function grounding terminal (below power switch) Feet Power connector (when specifying W, changed to screw terminal) (when specifying Y, changed to dedicated connector) Holes for fastening the feet ■ Rack Mount Fitting (ANSI/EIA) DA100 expandable type/DS400 subunit 6.8 482.6 453.2 37.7 177 101.6 14.7 DA100 stand-alone type/DS600 subunit 6.8 482.6 453.2 37.7 177 101.6 14.7 16 GS 04M01B01-11E <<Contents>> <<Index>> ■ Dimensional Drawings 20 145 Unit: mm 115 DA100 Stand-alone type/Subunit DS600 369 100 422 156 162 22 20 176 168 55 20 115 145 DA100 Expandable type/Subunit DS400 290 336 320 100 22 40 50 165 50 8 If not specified, the tolerance is ±3%. However, in cases of less than 10 mm, the tolerance is ±0.3 mm. GS 04M01B01-11E Subject to change withut notice. 17