Roundhouse Theatre Rehearsal Room Technical Specifications Updated 28/4/08 Technical Manager: Phone number: Mobile Number: Fax number: Email address: Kyle Morey 07 3007 8614 0424 014 229 07 3007 8699 kyle@roundhousetheatre.com.au Venue: Phone number: Fax number: Website: 07 3007 8600 07 3007 8699 www.roundhousetheatre.com.au Generated from the APACA Technical Specifications Template. For more details visit www.apaca.com.au Roundhouse Theatre_Rehearsal Room_TechSpecs08.doc STAGE Brief Stage Description: Large rectangular studio space with white walls. Masonite over sprung timber floor. Adequate space to set-up auditorium and stage area, but no fixed seating or staging. Stage distributed load limit 750kg/m2 Stage point load limit 300 kg Stage rake No Stage Dimensions: Proscenium Width N/A (Room 9500mm wide) Height N/A (Room 6000mm high) Setting Line Setting line is along far wall of studio. Distance From (SL = Setting Line, CL = Centre Line) SL to DS edge of apron N/A SL to DS edge of Orchestra Lift/Pit N/A SL to first fly line N/A SL to last upstage fly line N/A SL to rear wall 13900mm CL to OP wall (or obstruction) 4750mm CL to PS wall (or obstruction) 4750mm Stage to underside of roof 6000mm Overhead obstructions No overhead obstructions (other than overhead fluro battens) Auditorium: No fixed auditorium or seating, adequate space to set up portable seating in any configuration. Seating capacity with additional Orchestra lift/pit seating installed N/A Seating capacity without Orchestra lift/pit seating installed N/A Orchestra Lift / Pit: Orchestra Pit N/A Page 2 of 13 Roundhouse Theatre_Rehearsal Room_TechSpecs08.doc Flying Facilities: Fly System No fly system available Drapery: Type Dividing Curtain (Fixed Position) Material Colour Wool Black Width Height Quantity 2 x 5000 6000 1 Access Equipment: Elevated Work Platform Genie EWP-30S, push around vertical man-lift Maximum reach is 9020mm EWP Restrictions Outriggers must be in and wound down to ascend, and must remain in at all times. One staff member should be in the area at all times EWP is in use. Must only be used by trained personnel. Ladders (2) 1.8m Aluminium Step Ladder (1) 2.1m Fibreglass Step Ladder (1) 3m Aluminium Step Ladder (1) Small extension ladder with bar hooks (approx 5m full extension) (1) Large extension ladder (approx 8-9m full extension) Staging Units: No staging units available on site Stage Covers: No additional stage covering available Stage Traps: No stage traps in studio Safety Curtain: Safety Curtain installed No Additional Requirements No installed safety curtain means naked flame on stage is not allowed in most circumstances. A clear 1200mm corridor around set/seating must be left to all fire escapes. Page 3 of 13 Roundhouse Theatre_Rehearsal Room_TechSpecs08.doc Loading Dock: Access Limited loading dock facilities available via side door of studio. Small to medium sized vehicle access by prior arrangement only. Loading Dock Height At road level Door Dimensions 3120mm High 3000mm Wide Restrictions / Obstructions Loading door is accessed via public space, care must be taken when entering and loading/unloading vehicles. Additional Rigging Notes No rigging points in studio. Some unrated lighting bars at each corner can be used to hang light objects from. Staging Notes: No additional staging notes. Page 4 of 13 Roundhouse Theatre_Rehearsal Room_TechSpecs08.doc LIGHTING Positions: Stage LX Bars 4 Lighting bars are fixed at each corner of the room. There are space and patch points to rig about 6 lights on each. Control: Lighting desk LSC Precept 24 Control channels 24 Signal output DMA Signal distribution DMA direct to rack Remote riggers available onstage No Dimmer Racks: Total Dimmers 12 Dimmer Locations Beside lighting board (corner of room) 2.4Kw Dimmer Racks 1 x LSC (Analogue) Total dimmers @ 2.4kw per dimmer 12 5Kw Dimmer Racks None Total dimmers @ 5kw per dimmer 0 House Lights: Independant control Yes, controlled via on/off wall switch Control positions N/A Fade time adjustable N/A Stage Luminare: Profiles Make Prolite Model Angle 16/27 deg Detail / Accessories Watt 600w Total 2 Watt 600W Total 4 Watt 300W Total 12 Fresnel’s Make Prolite Model Detail / Accessories Some barn doors available Par Cans Make Model Par 56 Angle MFL Detail / Accessories Page 5 of 13 Roundhouse Theatre_Rehearsal Room_TechSpecs08.doc Patching: Location Outlets on wall behind lighting bars Floor Outlet Quantity Numbering (PS to OP) 12 1 - 12 1 13 Detail / Accessories Can be used as GPO Power: 3 Phase Outlets 1 x 3 Phase Outlet, corner of room with dimmer rack Cabling: 240v Extension Cable Good stock of 240V extension leads in various lengths from 1m to 20m. Looms None available 3 phase Extensions None available Lighting Notes: Lighting in standard configuration to provide good general lighting for most functions and activities. Moving of studio’s standard lighting rig requires prior consultation with venue technician. Very limited lighting control available. Standard lighting desk not ideal for operating a show. Page 6 of 13 Roundhouse Theatre_Rehearsal Room_TechSpecs08.doc AUDIO Control Positions: Control Room Audio control in corner of room (with lighting control) Auditorium Audio control can be positioned anywhere in the room. Standard audio desk cannot be moved (client must provide own desk or hire can be arranged). Control & Amplification: Primary Mixer Behringer Eurorack MX1602, 16 Channel Mixer Amplifiers Australian Monitor AM1200 Quad Amplifier EQ Behringer Ultra-Graph Pro Stereo EQ FX None Compression / Limiter / Gates None Speakers: FOH Speakers 4 x LB 12/6/4xH FOH Speakers Foldback None available (shape of room and position of FOH speakers means foldback usually not necessary). Playback: Item Dual CD Deck Mini Disc Deck Make Denon Sony Model DN-D4500 MDS-JE510 Detail Dual Auto-Pause CD Player Player/Recorder Total 1 1 Line Patching: Location Centre of Side Wall Quantity 2 Numbering 1-2 Detail Quantity 4 Numbering (N/A) Detail Permanent patch to FOH Speakers Speaker Patching: Location Corner of room Page 7 of 13 Roundhouse Theatre_Rehearsal Room_TechSpecs08.doc Cabling: Audio Cable Studio has good stock of XLR cable, and sufficient adaptors and gender benders. Multicore No multicores available. Audio Notes: Additional audio equipment may be available for hire. Please see Roundhouse Theatre technical specifications or separate hire equipment document, or alternatively contact the Venue Manager. Page 8 of 13 Roundhouse Theatre_Rehearsal Room_TechSpecs08.doc AUDIO VISUAL Projection Room: No projection facilities available. Projectors: Type Sanyo Data Projector* Model PLC-XT25 Detail / Accessories Motorised lens shift, zoom and focus Total 1 Screens: Projection Screen No projection screen available Projector Rigging Points: Moveable projector stand available. Roof mount cradle also available, but no rigging points in ceiling. Cabling: Small stock of short VGA, RCA patch leads. Some 20m VGA and Coax leads available. Audio Visual Notes: Limited projection facilities available as standard; additional equipment can be arranged at client’s request. * May incur additional hire charges Page 9 of 13 Roundhouse Theatre_Rehearsal Room_TechSpecs08.doc BACKSTAGE Communications: Stage Managers Desk No Stage Manager’s Desk. All technical equipment house in cupboard in back corner of room. Talkback Master Unit No talkback system available Paging / Show relay None available Stage Monitor None available Q Light System In house Q light system available No Dressing Rooms: Dressing Room None Available Capacity Toilets Shower Details Laundry / Wardrobe: Washing Machines None (client may be able to share facilities with theatre by arrangement) Dryers See above Drying rooms See above Iron / ironing board See above Clothes racks See above Production Facilities: Production Desk None available. Production Office None available (client may be able to share facilities with theatre by arrangement) Phone Foyer phone can be accessed by arrangement Fax No Access to phone for internet access Phone line can be accessed by arrangement Page 10 of 13 Roundhouse Theatre_Rehearsal Room_TechSpecs08.doc Greenroom: Tea / Coffee facilities Possible by arrangement Fridge / freezer Fridge Microwave Possible by arrangement Running water No Stage Door: Access No stage door. Access to venue is provided by Duty Technician, or via reception on Level 5 of venue building. ADDITIONAL FACILITIES & INFORMATION Orchestral: Parlour piano available. Tuning must be arranged after moving.* Rehearsal Space: N/A Other: Additional hire equipment available 25 plastics chairs available on request 4 trestle tables available on request * May incur additional hire charges Page 11 of 13 Roundhouse Theatre_Rehearsal Room_TechSpecs08.doc VENUE: Venue Contacts: Venue Address 6-8 Musk Avenue, Kelvin Grove, QLD Venue Postal Address PO Box 212, Kelvin Grove, QLD 4059 Staff Contacts: Head Venue Tech. Kyle Morey Mobile 0424 014 229 Email Address kyle@roundhousetheatre.com.au Phone Number 07 3007 8614 Venue Manager Shari Irwin Email Address shari@roundhousetheatre.com.au Phone Number 07 3007 8622 Head Company Tech. David Hints Email Address david@laboite.com.au Phone Number 07 3007 8608 Production Manager Mark Lloyd Hunt Email Address mark@laboite.com.au Phone Number 07 3007 8606 Administration Phone Number 07 3007 8600 Email Address admin@laboite.com.au Fax Number 07 3007 8699 Stage Phone Number 07 3006 8666 Venue Plans: Venue Plan Available Yes. Available in DWG or PDF at various sizes and scales. Can be emailed or snail mailed upon request. Printing costs for plans may be passed on to hirer. Also available from APACA website or www.roundhousetheatre.com.au Venue Section Available Yes. As above. Page 12 of 13 Roundhouse Theatre_Rehearsal Room_TechSpecs08.doc Venue Information: Australia’s only purpose-built theatre-in-the-round the Roundhouse Theatre is a unique and versatile performance venue. Renowned for its intimacy, accessibility and imaginative staging capabilities. • The Roundhouse Theatre is home to La Boite Theatre Company who run a 4 to 8 show season in the venue each year • There are two main venues onsite, the Roundhouse Theatre (398 seat) and a studio/rehearsal room (approx 100 person capacity) • The venue is situated 2km from the CBD along a major arterial road, 1km from the nearest train station, and a bus stop on the block. • Taxi phone located in foyer • Situated nearby are shops, restaurants, cafes and other facilities, and it is a short walk to several surrounding parklands • Disability access via ground and second floor, with disabled toilets in foyer and dedicated wheelchair seating • The foyer bar and café can be open during performance by request • No dedicated patron car parking, however there is ample parking on the street and surrounding blocks. Page 13 of 13