COMPONENT SPECIFICATIONS 50/125 Multimode

COMPONENT SPECIFICATIONS
50/125 Multimode 3.0mm Jacketed
Simplex Riser and Plenum Cables
Type OFNR, CSA FT4 and Type OFNP, CSA FT6
Cleerline NSF - Non Strip Fiber simplifies and improves the
process of fiber optic termination. There have been many
advancements in the technology of fiber optic connectors over
over recent decades. Cleerline NSF fiber now adds to this
equation increasing the speed, efficiency, and safety, all while
reducing the tooling involved in terminating fiber optic cables.
Cleerline NSF fiber is compatible with all common connector
systems on the market for standard 50/125 multimode fibers.
Simplex Riser / Plenum
Typical Cross Sections
Features And Benefits:
* Simplified termination process
* Integral coating eliminates stripping
* Bend insensitive fiber
* Increased safety factor
* Glass fiber remains protected
* Ultra low attenuation loss
* High tensile strenght
* 250um Soft peel jacket identifier
CONSTRUCTION
FIBER
Number of Fibers; Simplex = 1
50/125 Multimode OM3
250um "Soft Peel" coating (1 = Orange)
Color Coding per TIA/EIA 568C
JACKET
Flame-retardant Riser Rated PVC / Plenum Rated PVC
3.0mm unit diameter
Orange jacket - multimode fibers
Sequential footage markings*
Aramid Yarns (Kevlar)
PART NUMBERS
PART
NUMBER
PART
DECRIPTION
FIBER
NOMINAL
COUNT DIAMETER
CABLE
WEIGHT
TOTAL
WEIGHT
RISER RATED
S50125MOM3R
Simplex Riser
1 Fiber/s
3.0mm
6.61 lbs/kft
7.71 lbs
Simplex Plenum
1 Fiber/s
3.0mm
6.61 lbs/kft
7.71 lbs
PHYSICAL DATA
Storage Temperature Range = -40 to +85 C Operating Temperature Range = -20 to +75 C
Max Tensile Load for Installation = 1000(225) N(lbf) Max Tensile Long Load term = 500(112) N(lbf)
Min. Bend Radius, Unloaded = 10 x OD (10 x 125um
Cable Outside Diameter, Nominal = 3.0mm
Cable Package = 1000ft Pull Box
Canadian Rating = FT4/Riser – FT6/Plenum
APPLICATIONS
Interconnect design compatible with connectors
requiring 3.0mm jacket diameter
Fiber- to- the-Desk (FTTD)
ETL Listed Type OFNR or OFNP for installation in vertical riser
and general horizontal applications when installed in
accordance with the NEC article 770-51 (b) and 770-53 (b)
ETL listed Type OFNP for installation in ducts, plenums
and other spaces used as environmental air returns
when installed in accordance with NEC article 770-51 (a)
and 770-53 (a)
ENVIRONMENTAL CHARACTERISTICS
Temperature Dependence at 850 nm and 1300 nm ≤ 0.5 (db/km)
Induced Attenuation - 40oC to +85oC
Watersoak Dependence at 850nm and 1300 nm ≤ 0.5 (db/km?
Induced Attenuation at 23oC for 30 days
Damp Heat Dependence at 850 nm and 1300 nm ≤ 0.5 (db/km)
Induced Attenuation at 85oC, 85%R.H., 30 days
PLENUM RATED
S50125MOM3P
PHYSICAL CHARACTERISTICS
Core Diameter 50.0 ± 2.5(um)
Core Non-circularity ≤ 6 (5)
Core / Cladding Concentricity Error ≤ 3.0 (um)
Protective Coating Diameter 125 ± 2 (um)
Protective Coanting Non-Circualrity Error ≤ 3.0 (um)
Color coating Diameter 250 ± 10 (um)
Fiber Curl ≧ 2 (m)
Proof Tes 100 (Kpsi)
Bend Induced Attenuation at 1300 nm ≤ 1.0 (db)
(100 turns around a mandrel of 75 mm diameter)
Dynamic fatigue constant (nd) > 30
Length (Typical 1.0 - 8.8 (Km)
COMPLIANCE
ETL Listed ONFR / ONFP
CSA FT4, CSA FT6
RoHS Compliant Directive 2002/95/EC
CLEERLINE TECHNOLOGY GROUP, LLC
8404 El Way Drive #2B, Missoula, MT 59808 Sales - 866-469-2487 Fax - 406-532-0060 Web - www.clrtec.com
Copyright 2012 Cleerline Technology Group, LLC., All rights reserved. Subject to change without notice