Downloadable file - Iowa DOT Consultant Utilization

advertisement
2009 Bridge Inspections
Dear Consultant:
The Iowa Department of Transportation is contacting firms prequalified in Category 325 (Bridge
Inspection and Analysis) to determine their interest in providing bridge inspection services.
Four consultants will be selected to inspect a total of six bridges. The first selection (Selection A)
includes inspection of the Iowa 9 (Lansing) Bridge over the Mississippi River in Allamakee County
and the Iowa 136 (North Clinton) Bridge over the Mississippi River in Clinton County. The second
selection (Selection B) will include inspection of the US 20 (Julien Dubuque) Bridge over the
Mississippi River in Dubuque County. The third selection (Selection C) will include inspection of
the US 34 (Burlington) Bridge over the Mississippi River in Des Moines County. The US 34
Bridge inspection includes a survey of the deck profile and opening stay cable anchorages to
inspect the interior condition. The fourth selection (Selection D) will include inspection of the I-129
Bridge over the Missouri River in Woodbury County and Iowa 92 (Muscatine) Bridge over the
Mississippi River in Muscatine County.
The inspection of the US 34 Bridge will be from the far side of Pier #8 thru the far abutment
(Spans #9 thru #18). The inspection of the remaining bridges will be from abutment to abutment.
A description of the bridges is as follows:
Selection A
Iowa 9 (Lansing) Bridge over the Mississippi River, FHWA No. 13520 – 21’ x 1630’ steel high
truss bridge, 652’ main span, constructed 1931.
Iowa 136 (North Clinton) Bridge over the Mississippi River, FHWA No. 21055 – 25’ x 3011’ steel
high truss bridge, 500’ main span, constructed 1974.
Selection B
US 20 (Julien Dubuque) Bridge over the Mississippi River, FHWA No. 23880 – 28’ x 5760’ steel
tied arch bridge, 845’ main span, constructed 1943.
Selection C
US 34 (Burlington) Bridge over the Mississippi River, FHWA No. 23441 – 78’ x 2268’ cable stayed
bridge, 660’ main span, constructed 1994.
Selection D
I-129 Bridge over the Missouri River, FHWA No. 600765 – 79’ x 2606’ (Spans #9 thru #18) steel
girder bridge, 450’ main span, constructed 1976.
Iowa 92 (Muscatine) Bridge over the Mississippi River, FHWA No. 38201 – 32’ x 3017’ steel high
truss bridge, 512’ main span, constructed 1972.
Full plans and previous inspection reports will be provided to the selected consultants.
The inspections are to include a hands-on inspection of fracture critical members and a routine
inspection of the remaining above water portions of the structure following the National Bridge
Inspection Standards (NBIS). Underwater inspection of the below water portions of the
substructure is not included in this work. The consultants selected shall be responsible for all
portions of the inspection including developing and implementing a quality control and quality
assurance (QC/QA) plan. The consultants selected will be required to provide documentation that
the personnel involved in the inspection meet the qualifications of the NBIS.
The consultants will be responsible for providing all traffic control and access equipment.
Preference will be given to consultants who demonstrate inspection methods that will minimize
traffic restrictions. All traffic control will be accordance with the Manual for Uniform Traffic Control
and Iowa DOT Standard Road Plans for Traffic Control. Restrictions on time and days for lane
closure may be in place.
The inspections for the Iowa 9 and Iowa 92 bridges are to be completed by August 31, 2009 and
the inspections for the remaining bridges are to be completed by October 31, 2009. Reports are
to be completed 45 calendar days following the completion of the inspections. It is anticipated
that work for these selections will be authorized to begin July 1, 2009.
The Iowa DOT is contacting your firm to determine your interest in being considered for this work.
If your firm is interested in providing the described services, please submit a proposal stating your
ability and availability to complete this work. Only electronic submittals will be accepted. The PDF
should be formatted to print on 8.5” x 11” pages. Proposals must be limited to twenty single-sided
8.5” x 11” pages. Proposal covers, dividers, and a single-page cover letter will not be counted
against the page limit. Proposal pages in excess of page 20 may not be considered. On the cover
page of the proposal, please include the RFP for which the proposal is submitted and the email
address of the person who should receive the results of the selection. Costs should not be
submitted as part of the proposal and if submitted will not be considered.
The Disadvantaged Business Enterprise (DBE) program does not apply to these proposed
contracts. However, the department encourages the spirit of the program be incorporated in these
proposed contracts when outside assistance may be required to perform the work.
The Iowa DOT will treat all information submitted by a consultant as open records following the
conclusion of the selection process. Open records are public records that are open for public
examination and copying. The Iowa DOT’s release of records is governed by Iowa Code Chapter
22 and 761 IAC Chapter 4. Consultants are encouraged to familiarize themselves with these laws
before submitting a proposal.
The selection committee has established the following criteria for evaluating the proposals
submitted. The weighted value of each criterion is indicated.
A. Staffing:
1. Specific qualifications of project manager - 15%
2. Specific qualifications of team - 10%
B. Past experience with similar types of work - 50%
The evaluation will primarily consider past experience of the identified project manager and staff
that will comprise the project team.
C. Access for inspection - 15%
The evaluation will consider the use of inspection access methods that will limit traffic restrictions.
D. Ability to meet schedules - 10%
Your proposal should include:
A. The name and office address of the project manager who will direct the work and the names of
key staff that will be working on the contract.
B. The location of the office where the majority of the work will be performed.
C. A list of subconsultants and the work they will perform.
D. A disclosure of any work you have for other clients that may be affected by the work on the
proposed contract.
E. A list of references from a variety of projects and contact information for the listed references.
References can be for work done other than for the Iowa DOT.
The electronic proposal must be submitted via email to Michael.Todsen@dot.iowa.gov. An email
will be sent confirming receipt of the proposal within 30 minutes or by 1:00 p.m. on the submittal
deadline date, whichever is later. For your firm to be considered, all information must be received
by 3 p.m. on March 12, 2009.
If there are any questions concerning this letter, please submit your requests via email to
Michael.Todsen@dot.iowa.gov. Any questions about this RFP must be received by noon on
March 5, 2009. Questions and answers regarding this RFP will be posted on the following web
site:
http://www.prof-tech-consultant.dot.state.ia.us
Contacting any other selection team member is considered inappropriate. Oral interviews are not
anticipated.
Sincerely,
Michael J. Todsen, P.E.
Office of Bridges and Structures
cc: N. McDonald, Bridges and Structures
D. Maifield, Bureau Support Services
Download