Hello! Welcome to Brightsky World!Connecting newest technology 5iserise fire alarm system that will Exceed your imagination:directly and plenty figure interface you will be the first time to feel our products’ reliability,The speed of fire alarm system is quicker than before, Brightsky Electronic Co., Ltd quests system reliability and accurately that will be embodied completely. This customer manual will let you know the super function of this kind of machine step by step. Characteristics LCD large screen display(maximal display 300 pcs 16×16 matrix Chinese or English per screen) 。 High speed processing, short response time。 Graphic menu operation, new design Support detector isolation function。 Chinese Pinyin or English input。 Alarm address information second-conversion to accurately locate fire location. Or the address can be pre-programmed in the computer and uploaded into the panel. Detailed operation is referred to “5i programming tool” software. Linkage/associated control relationship site programming Real 2-wire bus, detectors and modules can be in the same loop line High speed and clear thermo-sensitive printing for the printer 3000 addressable points for standard configuration to meet large projects demand. The system can be expanded to 16000 addressable points. 2000 pcs historical records for future reference Module structure design. The system configure can be combined or adjusted based on customer requirement. Powerful Ethernet communication function Wonderful window protection function Our Stipulations 在以下的描述中: all display letter or icon is button,For example: this is Down button , 复位 this is Reset button Bus equipments include heat detectors, smoke detectors, manual call points, signal input module etc fire alarm touching equipments and remote control module etc Linkage control equipments. According to habit or description’s requirements,It will be possible to use“Detector”letter can 无锡蓝天电子有限公司 1 JB-QB-5Li fire alarm control panel operation manual take place smoke detector, heat detector, manual call point, signal input module etc fire alarm touching equipments Mainframe is main control function unit. It is one core unit to manage and control sub-panels and modules and system components. Sub panels are data acquisition cards and zone alarm control panels. Data acquisition cards is function cards which are used to manage and monitor detection bus lines, report detection bus loops abnormal condition to main control unit, receive and implement main control unit’s linkage operation commands. Zone alarm control panel normally is 5Si fire alarm control panel System modules and components include sub panels, bus linkage operation cards, multi-line linkage operation card, fire extinguishing function card and communication function card. Bus linkage operation card is used to mange bus linkage operation keyboard. It is function card to be used to realize remote control module direct push button open/close. Its detailed description is referred to “keyboard” section. Multi-line linkage operation card is used to mange multi-line linkage operation keyboard. It is function card to be used to realize one-to-one direct external control push button open/close. Its detailed description is referred to “keyboard” section. Fire extinguishing control card is function card to realize fire extinguishing control. Communication card is function card to mange fire repeaters. Technical Data Main Power: AC 220V (+10%~-15%) 50HZ Back-up power supply: DC 24V,10AH Work consumption: Monitor state:≤2.4W;Alarm state:≤10W Basic monitoring capacity: 5i series addressable intelligent detectors 3000 units, maximal to 16000 units Polling cycle: <10 second(when Condition abnormity, single point continues to poll) Signal transportation distance: ≤1500 meters Wiring method: 5i series detectors, manual call points — — 2-wire bus, non-polarity; 5i series modules——2-wire bus, polarity(T+——anode, T-——cathode) ; Wire application: Signal line adopts fire resistant copper core lead line whose sectional area is no less than 1.5mm2 , power supply line adopts fire resistant cooper core lead line whose sectional area is no less than2.5mm2 Outside control contact points: KA1,KA2 first time alarm, then closed immediately. Outside control contact points capacity: DC 30V,2A. Operation environment temperature: 0℃~55℃ 2 Wuxi Brightsky Electronic Co., Ltd JB-QB-5Li fire alarm control panel operation manual Relative humidity: ≤95% Configuration size: 1250×700×220(H×W×T)mm3 Installation method: Wall mounted Weight: About 50Kg Black box records numbers: Be able to record latest 2000 pcs records, including open, close down panel, reset, fire alarm, fault and linkage operation commands. Linkage programming amount: 2500 pieces, including or 1, or 2, and logic, link and so on. Room number conversion capacity: 3000 pieces(preceding 12 zones) Room number conversion maximum allowable characters numbers: 20 pcs English character or 10 pcs Chinese Sub-machine(data acquisition card and zone alarm control panel) amount: ≤32 pcs Bus linkage operation card (main card) amount: ≤12 pcs,each main card can be connected with 11 pcs ancillary cards. Each card has 16 set push buttons. So, each main card can control 192 points remote control modules, (1 main card+11 ancillary cards)×16=192. The system can use push button to control 12*192=2304 points remote control modules. Multi-line linkage operation card amount: ≤10 pieces, each card can connect 16 pieces multi-line modules Fire extinguishing function card amount: ≤16 pieces, each card can connect 2 fire extinguishing zones Fire repeater amount: ≤120 pieces Structure and installation This control use wall mounted structure,There are 10Ah all sealed battery. Structure compact, Placement reasonably, Outline beautiful. This is outline structure figure: Wuxi Brightsky Electronic Co., Ltd 3 JB-QB-5Li fire alarm control panel operation manual This is internal structure figure: 4 Wuxi Brightsky Electronic Co., Ltd JB-QB-5Li fire alarm control panel operation manual This is installation size figure: Wuxi Brightsky Electronic Co., Ltd 5 JB-QB-5Li fire alarm control panel operation manual 67 安装孔4-φ12 550 75 1,050 进线孔 203 667 1,250 180 700 Fire alarm controller should be installed in a room or place where can be controlled by man,at the same time please install fire alarm controller on the wall. Normally fire alarm controller’s bottom is far away from the ground 1.5 meters,It will leave more than 0.5 meter distance in two sides. So that it will be easy operate and maintenance. 6 Wuxi Brightsky Electronic Co., Ltd JB-QB-5Li fire alarm control panel operation manual Outside wiring requirements: Signal line adopts fire resistant copper core lead wire whose sectional area is no less than 1.5mm2. Power supply line adopts fire resistant copper core lead wire whose sectional area is no less than 2.5mm2. External wiring terminal layout figure: Explanation: 1、 Tn+、Tn- is alarm linkage operation loop bus, 1≤n≤64,the above figure just shows 12 loops for the sample example, each loop can connect 250 addressable equipment, which include fire detectors and remote modules. 2、 K1、K2 are external control contacts. They will be closed after first fire alarm and no time delay. 3、 D+、D- are 485 communication bus and connect zone control panel or remote data acquisition card. External connected zone control panel, remote data acquisition card and this panel internal data acquisition cards total number cannot be more than 32 pieces. 4、 Fn+、Fn- are fire repeater communication bus, 1≤n≤4, each loop can connect 30 pieces fire repeaters maximally. Fire repeater address in the 4-loop bus adopts united address. The number is between 1 and 120. 5、 F、M are broadcast audio frequency line 6、 TH+、TH-、H+、H- are telephone bus, connect DM5i telephone control modules. TH+ and THare signal bus, connect DM5i’s T+、T-, H+、H- are telephone audio frequency lines, connect DM5i’s H+、H-. Each loop telephone bus can connect 90 pieces address telephone control module. 7、 Cn+、Cn- are direct output external control contacts, connect RM5i/B relay modules, 1≤n≤ 160, each set terminals just can connect one module. Wuxi Brightsky Electronic Co., Ltd 7 JB-QB-5Li fire alarm control panel operation manual 8、 SIGn1、SIGn2、VDn+、VDn- are fire extinguishing protection zone control bus, connect SK5i gas manual control box, 1≤n≤32, its wiring is corresponding to SK5i manual gas control box’s SIG1、SIG2、VD+、VD-. Sound, LED and Keyboard Sound This control panel can send out 2 different sounds to indicate fire alarm, fault and linkage operation status. Fire alarm and linkage operation status are indicated by one same sound. We cannot use written language to describe the 2 sounds difference. But, after you test our panel: push down self-checking button, during the system self-checking, it will send out one sound to indicate fire alarm (linkage operation). Another sound will be indication for fault. Fire alarm (linkage operation)sound: when there is fire alarm or linkage operation( module activated or response), it will send out fire alarm (linkage operation) sound; Fault sound: when detectors or modules have fault, or system components have fault, or main power or back-up power supply has fault, it will send out fault sound. LED Fire alarm LED:illuminated in fire alarm status, if not, LED extinguished; Linkage operation LED:illuminated when modules are activated or response, if not, LED extinguished; Fault LED:illuminated when modules and loop products have fault, if not, LED extinguished; Isolation LED:illuminated when the equipment is isolated, if not, LED extinguished; Back-up power fault LED:when the back-up power supply voltage is less than 21.6V or there is power charging fault, the LED is illuminated, if not, LED extinguished; Main power fault LED:when the main power supply voltage is less than 180V, the LED is illuminated, if not, LED extinguished; back-up power LED:when the back-up power is working, the LED is illuminated; Main power LED:when the main power is working, the LED is illuminated; Silence LED:When the LED is illuminated, it shows that there are fire alarm, fault or linkage operation, but the sound has been closed down. Polling LED:if the LED flashes, it shows that the system is in normal operation status. Keyboard The control panel front keyboards have clear indication of their function. So we do not discuss it once again. Now we discuss “bus linkage operation card” and “multi-line linkage operation card” keyboards. Bus linkage operation card: this card keyboard is used to open or close remote control modules. It includes main cards and ancillary cards. Each main card can connect 11 pieces ancillary cards. Each card has 16 keys. Each key controls one addressable remote module. Key number is coded 8 Wuxi Brightsky Electronic Co., Ltd JB-QB-5Li fire alarm control panel operation manual from main card. Its turn is main card, No.1, No.2, No.3… No.11 ancillary card. The number is from 1 to 192. The second main card and ancillary card number is from 193 to 384, and so on. The corresponding relation set-up between key number and module number is referred to “key number” section. Each panel’s bus linkage operation card amount is decided based on the customer project requirement. The maximal capacity can be 12(main card)×12(each main card includes itself and 11 ancillary cards)=144 pieces (144×16=2304 points)。 Multi-line linkage operation card: the keys on this card is one-to-one direct hardware activation push button. Each card has 16 keys. Each key controls one addressable multi-line module. The key number is coded from first card and so on. Such as, if first card’s first key number is No.1, the second card’s first key number is No.17….. and so on. Each control panel’s multi-line linkage operation card amount are decided based on the customer project requirement. The maximal capacity is 10 pieces (10×16=160 points). From installation to operation 1、 Please read this manual carefully 2、 Based on “structure and installation”section, install this panel 3、 Use megohmmeter to measure alarm bus earth resistor value. The resistor value should be more than 20 megohm. At the same time, based on wiring terminal layout figure to check the wiring is right or not and make sure that various fasteners have been fixed tightly. Mount the fire detectors based on local fire regulation requirement. 4、 Start up。 5、 In “system management” set up “ automatically search above equipments when open the panel each time” as “enable”; 6、 Close down the panel, then start up once again。 7、 In “registration”, please register external equipments。 8、 According to “location” section, set up each equipment physical location。 9、 According to fire regulation requirement, edit linkage operation relation sheet based on “linkage operation programming” section。 Basic functions Start up the panel Please close main/back-up power switch, the panel is electrify reset. The control panel moves to initialization status: first make LEDs and sounder self check, then take turns to search system connected sub panels, bus linkage operation card (main card), multi-line linkage operation card, fire extinguishing function card, communication function card and so on. It shows the detected equipment amounts. For communication function card, it does not show these cards numbers. It shows this card connected fire repeater numbers. After the initialization, the panel moves to monitoring status. The panel front polling LED flashes. For the first time operation, if the operator need to register bus equipments, please make reference to “register external equipment” section. Wuxi Brightsky Electronic Co., Ltd 9 JB-QB-5Li fire alarm control panel operation manual 2002/11/02 09:23 Intelligent network fire alarm system Wuxi Brightsky Electronic 无锡蓝天电子有限公司 Co., Ltd http://www. - .com http://www.bsky.cn/english 蓝天电子欢迎您 Brightsky Electronic Welcome you … system initialization, 系统初始化,稍候 wait … 02 正在检测分机 checking extension ... 07 … 01 card ... 02 正在检测总线联动卡 chk associated control … chk multi_line control card ... 03 Fire Alarm In normal monitoring status, the control panel polls registered each detector, closely monitors each detector current smoke density or temperature value. And based on arithmetic, operate and identify this parameter. If it meets fire alarm establish condition, it will move into fire alarm status immediately. At this time, the control panel will send out fire alarm sound, the panel front fire alarm LED will be illuminated, the printer prints out fire alarm address and alarm time, the LCD screen displays alarm address, numbers and so on. At the same time, the control panel external control contacts K1, K2 are closed. If the linkage operation is in automatic mode, the control panel will follow pre-set logic relation to send out linkage 10 Wuxi Brightsky Electronic Co., Ltd JB-QB-5Li fire alarm control panel operation manual operation commands to activate corresponding remote control modules and active external equipment (such as fire pumps and so on). 火警总数 Fire all: 001 页:00 first fire:[02-117] time: 11/04 10:31 117 :11/04 10:31 区 号 发生时间 [02-117] 座二楼 215 215 门旁 区 号MCPT 手报 EE座二楼 门旁 2002/11/04 10:31 In above figure: First line “fire alarm total:001 page:00”, shows that there is one fire alarm, it is page 0. Second line “first fire:02 zone No.117 time:11/04 10:31”, shows that the first fire alarm equipment is No.117 located in Zone 02. The time is 10:31 of November 4. Third line “ Zone 02 No.117 MCP E St. #2. Building, 215 door side”, it is one fire alarm information. The fire alarm location is E St. #2. Building, 215 door side. Alarm equipment is one manual call point. Its equipment number is No.117 of Zone 02. Last line in the screen “2002/11/04 10:31”, it is system real time. System adopts pagination cycling method to display fire alarm, linkage operation and fault information. If the current system has 2 kinds or more information, the operator can follow the LCD screen indication, push down or to switch page window. Push down or to check current page’s previous or next information. Below shows one interface which has both fire alarm and linkage operation activation: Wuxi Brightsky Electronic Co., Ltd 11 JB-QB-5Li fire alarm control panel operation manual Page:00 : 001 Ctrl Fire all:001 火警总数 联动总数 all:002 页:00 first fire:[02-117] time: 11/04 10:31 区117 发生时间 : 001respn : 002 启动 start all:001 启动总数 应答总数 all:002 启动 02区008号 二楼东卷帘门 [02-008] 10:32 [01-010]号 一楼正压风机 10:32 Fire direct 火警方向 2002/11/04 应答 10:33 10:33 direct 10:33 Fail故障方向 In above figure: Image symbol clearly indicates it is linkage operation page interface. First Line “fire all:001 Ctrl all: 002 Page:00”shows current system has 1 fire alarm message and 2 linkage operation information. This is No.0 page. There is no need to explain second line. Third “start all: 001 respn all: 002” shows currently there is one equipment activated, two equipments have feedback (or response) signal. Fourth line “02-008 second floor east roller shutter door 10:32 10:33”, this linkage operation information shows: second floor east roller door has been activated on 10:32. Send back feedback signal on 10:33. The remote control module number which controls this roller shutter door is No.008 of Zone 02. Fifth line “01-010, first floor positive pressure fan 10:32 10:33”, this linkage operation information shows: first floor positive pressure fan has been activated on 10:32. Send back feedback signal on 10:33. The remote control module number which controls this positive pressure fan is No.010 of zone 01. We should make some explanation. Why do we say “10:33” shows feedback time rather than activated time? It is mainly judged from its display location. If the “10:32” row location displays time, this time is equipment activation time. Then in “10:33” row location, displayed time should be feedback time. Please note last time in the above screen, “ fire direct”shows push to be able to see system current fire alarm detailed information. Fail direct shows push to be able to see system current fault detailed information. Fault alarm In order to make sure that fire alarm control system can work normally for long time, fire alarm control panel should make close monitoring to loop lines, fire detectors, remote control modules, other bus equipments, power supply, rechargeable battery 12 Wuxi Brightsky Electronic Co., Ltd JB-QB-5Li fire alarm control panel operation manual and so on. It should have fault alarm function. In fault alarm condition, the control panel sends out ambulance sound. Panel front fault LED is illuminating. Fault type will be shown in LCD display screen. If the fault is from fire detectors or remote control modules, the printer will print out fault addresses, alarm time. The LCD display will show alarm address, alarm total amount information, and so on. At this time, the operator should eliminate the faults asap. After the fault is eliminated, the control panel will be automatically reset and move to normal monitoring status. Detector or remote control module fault In normal condition, each detector or remote control module will have one relatively stable measuring value. If this measured value is not stable, it shows that the detector or remote control module has problem. The control panel will send out detector fault or remote control module fault information. Page 页:00 故障总数 Fail all: 001 04区003号 SMOK 烟感 AA座一楼大厅 [04-003] 2002/11/04 10:38 System components fault If the system sends out sub-panel fault, bus linkage operation card (main card) fault, multi-line linkage operation fault, and so on, it shows that there is communication problem (communication lines) between the system components and main control panel. Or themselves problem has made communication break down between the system components and main control panel. This fault is a big problem. It indicates that the main control panel has lost the control function to a lot of system components and cannot control or activate these system components in fire condition. So the operator should find out the fault reasons asap and return the fire alarm system to normal operation status. Wuxi Brightsky Electronic Co., Ltd 13 JB-QB-5Li fire alarm control panel operation manual Main power supply fault Main power supply fault indicates: the AC 220V power supply voltage is less than 180V (including power break down), the control panel sends out main power supply fault. The main power supply LED is illuminating. At this time, the back-up power supply should be connected into the control panel. Otherwise, due to power lost, the control panel will be automatically closed down. Back-up power supply fault Back-up power supply fault indicates: internal back-up power supply voltage of the control panel is less than 21.6V, back-up power supply line break-down, back-up power supply rechargeable battery cannot charge the power, the control panel will send out back-up power supply fault. The back-up power supply fault LED will be illuminating. Menu operation function In monitoring status, push down menu button, the LCD display shows indication to input password: 权限控制right control Access Please input 请输入超级用户口令 superuser password >:: **** After input right password, the operator can enter into main menu, if not, the system will return to the monitoring status. Under main menu, there are 9 menu items, including Device、Fire Log、DateTime、 Program、Extinguish、CommTest、System、Help and Return。 14 Wuxi Brightsky Electronic Co., Ltd JB-QB-5Li fire alarm control panel operation manual 主菜单menu Main 设备管理 Device 历史记录 Fire log 日期时间 Datetime 联动信息 Program 灭火设置 CommTest Extinguish 通讯测试 系统管理 System 获得帮助 Help 返回监控 Return [self-chk]-select fun, [silence]-return Please push down “Up”, “Down”, “Left” and “Right” cursor key to get the necessary function, push down “self-check” key to enter into function sheet. Equipment management Equipment Management function is: register external equipments, refer registered information, test equipment status, isolate faulted equipments, set up equipment location, mapping module open/close to bus linkage operation card’s key. There are 8 sub-menu items, including: Register、Refer Val、Testing、 Curve、Isolation、动 Inching、Location, and Key Code. 主菜单menu>>Device Main >>设备管理 management Register 登记 Refer 查阅Val Testing 测试 Curve 曲线 Inching 点动 Location 位置 KeyCode 键号 隔离 Isolation [self-chk]-enter, [silence]-return 按自检键进入选择的功能,消音键退出 Wuxi Brightsky Electronic Co., Ltd 15 JB-QB-5Li fire alarm control panel operation manual Concerning how to enter into these sub-menu items, there are indications under the last line in the LCD screen display. So we do not discuss it any more. In addition, we will not discuss it in subsequent sections. Registration Registration is register external bus equipments (such as detectors, remote control modules) into main control panel and put on records on the panel. In this way, the main control panel can monitor these equipments. Also so and so only, these equipments are able to exert their functions. Otherwise, the system cannot work, just like a group without leader. 主菜单menu>>Device>>Register Main >>设备管理>>登记 Please input extension no.:01 请 输入分机号:01 Registering (500).. ... 正在登记(500) . 100 100 正在请求登记值. Asking register.. value ... 请求登记值完成! Registration complete! 结束 Finish! 按消音键返回 [silence]-return After enter into registration function, according to indication: Input extension number, push down “self-check” key; We push down 1 key to select registration, the main control panel will command extension or sub panel to register external equipments and display current registering process, such as: “registering (500)...100”, note: “500”indicats that this sub panel can connect 500 addressable bus equipments at maximum (detectors, modules and so on), this limitation is fixed at Wuxi Brightsky Electronic Co., Ltd Factory based on customer requirement and sales contract. It cannot be modified at project installation site. This number has 5 values, including 000, 125, 250, 375 and 500. The after “100”is not current registered equipment amounts, it is current registration course. Complete course is 254 units. The complete registration process need to take around between 1 and 2 minutes. Please wait with patience! 。 After registration is completed, the main control panel will read back external equipment registered original parameter values from sub panel. After the main panel reads back registration values, the whole registration process is finished. If the system needs to register other sub panels, after return, please enter into “registration” function and repeat above process once again. 16 Wuxi Brightsky Electronic Co., Ltd JB-QB-5Li fire alarm control panel operation manual Note: due to system components fault, it will make registration or read back registration value failure, at this time, the operator should check the system. After eliminating the fault, the operator does the registration work one again. Refer Refer is see registered equipments’ reference value, equipment type, equipment location information and so on. Note: in this function, the operator cannot modify any information. The operator just can see the information only! Enter into refer function, please first select refer zone. 主菜单menu>>Device>>Refer Main >>设备管理>>查阅Device 请输入区号: 01 no.:01 Please input zone -返回 [silence]-return 自检[self-chk]-confirm, Input zone number, according to indication and confirmation, the operator will see selected zone’s registered equipments detailed information. 主菜单>> Main>>Device>>Refer[01] 总数:010 >>查阅01区total:019 No.001 26 烟感 SMOK 001号 26 No.002 26 SMOK 002号 27 烟感 No.003 26 SMOK 号 26 烟感 No.004 26 烟感 SMOK 004No.001 26 26 No.005 26 SMOK 005号 26 烟感 No.006 SMOK 006号 26 温感 007号 27 No.007 26 温感 SMOK 008号 26 温感 No.008 SMOK 009号 26 手报 No.009 SMOK 010号 26 手报 No.010 SMOK 座一楼大厅 AA座一楼大厅 A 座一楼大厅 A座一楼大厅 A A 座一楼大厅 座一楼大厅 AA座一楼 房 SMOK A 座一楼大厅 A 座一楼大厅 A座一楼 102房 座一楼大厅 A座一楼 103房 A座一楼 104房 座一楼大厅 A座一楼 105房 座一楼大厅 A座一楼 106门旁 座一楼大厅 A座一楼 107门旁 座一楼大厅 Up/down-scroll,silence-ret,</>-accelerat 上下-翻页,消音-返回,左右-加速翻页 Wuxi Brightsky Electronic Co., Ltd 17 号 JB-QB-5Li fire alarm control panel operation manual In above figure up right position: “total: 010”indicates in this zone, the registered total equipment amount is 10 pieces (address). We use “No.001 26 SMOK A Str. 1 floor lobby” line to explain this page display format: “No.001”is equipment location number. It is locked in No.01 zone. So its equipment number is No.001 of No.1 zone; “26” is its original registered value”; “SMOK” shows that this equipment type is optical smoke fire detector. “A Str. 1 floor lobby” is this equipment physical address in the protection area. Test Test is test various external connected equipments’ current value to observe whether the equipment function is normal or not. Please first select necessary sub panel number which need to do test; After confirmation, the operator will see this sub panel connected equipments’ registered value and their current values. If the sub panel has fault, the current value line will not show any words, total empty! 主菜单menu>>Device>>Test Main Ext.01 01分机 >>设备管理>>测试 Device no.:000 设备号: 001 002 003 004 005 006 z.01 RegVal 000 01 区登记值: 026 026 026 027 027 027 z.01 CurVal 000 01 区当前值: 026 026 026 026 026 026 z.02 RegVal 000 02 区登记值: 026 027 027 027 027 027 z.02 CurVal 000 02 区当前值: 026 028 028 028 026 026 -加速翻页 Up/down-scroll,silence-ret,</>-accelerat 上下 In normal condition, external connected equipment analogue value will be between 20 and 30. If the current value is not in this range, maybe the equipment has problem. The registered threshold value is 15. Curve This function is closed in this English operation panel. Isolation 18 Wuxi Brightsky Electronic Co., Ltd JB-QB-5Li fire alarm control panel operation manual This control panel has isolation function to bus equipments, various system components, fire repeaters and other faulted equipments. The isolated equipment will not send out fire alarm, fault or activation. If the operator wants to cancel the isolation, please push down “up” and “down” cursor to move to desired deleted line, push down 2 key, this line will be marked as “*”number, it indicates that this line corresponding equipment has been isolated. Push down 2 key once again and “*”number will be eliminated. It indicates that the equipment isolation has been resumed. 主菜单>>Device>>Isolating Main all:002 002 >>设备管理>>隔离 总数: > > 001:01—002 SMOK 烟感 001:01区001号 002: 002 bus control card 002:02号数据采集卡 1-add,2-delete,left/right-pageup/down 1 -新隔离,2 -删除,左右键-上下翻页 If the operator wants to add new isolation, please push down into “add isolation” function. 主菜单menu>>Device>>Add Main Isolating 隔离 >>设备管理>>添加 type:bus equipment 类 型:总线器件 0101no.: 号z.: 码: 区001001 号 Reset-confirm,silence-ret,selfchk-switch -返回,自检-类型切换 Wuxi Brightsky Electronic Co., Ltd 19 1 key and enter JB-QB-5Li fire alarm control panel operation manual Inching Inching is set up remote control module’s inching activation mode. After the module which has been set up as inching mode receives activation command, it will work as” activation->time delay about 1 second->close. Note: LCD inching module linkage operation display will not be eliminated after the inching process is finished. It will be remained in the LCD display screen until the system sends out close command once again. If the operator wants to delete any one inching set-up, push down “Up” and “Down” key and move cursor to desired deleting line, push down 2 key, this line will be marked as “*” number. It indicates this line information has been deleted, push down 2 key once again, “*” is eliminated, it indicates that the line setup has been resumed once again. 主菜单>>Device>>Inching Main 总数:001 >>设备管理>>点动 total:001 > 001: : z.01 01区no.001 001号至to 002002 号 1键-添加,2键-删除,左右键-上下翻页 1-add,2-delete,left/right-pageup/down If the operator wants to add new inching information, please push down and enter into “add inching” function. 20 1 Wuxi Brightsky Electronic Co., Ltd key JB-QB-5Li fire alarm control panel operation manual 主菜单menu>>Device>>Add Main inching 点动 >>设备管理>>添加 Range:z.001 01区001No.001 号至002to 号 No.002 -返回 [self-chk]-confirm,[silence]-return 自检 Location Location description is used to set up equipment physical location and its address will be shown in alarm status. Therefore, the operator can find its location asap in fire alarm or fault condition. And the operator does not need to refer numbers and check list and other ancillary information figure. It is named as “room number conversion”. 主菜单menu>>Device>>Location Main 设备管理>>位置 01 Address: 地 址: z.:01 区001 no.:001 号 Location: 位置描述: E E座二楼会客大厅 座二楼会客大厅 拼音 ABCD: silence-del,self-chk-confirm,reset-ret 消音-删除, -确认,菜单,复位-返回 This panel can keep location records up to 3000 pieces. It can convert equipment location from No.1 zone to No.12 zone. If there is no conversion, it just displays detector or module’s logic address. It is equipment number. Wuxi Brightsky Electronic Co., Ltd 21 JB-QB-5Li fire alarm control panel operation manual In this function: Chinese input adopts Pinyin input method, at the same time, via input method switch, it can also input big letter, small letter and digits. It will help the operator make detailed and accurate descriptions to detector or module location. Select desired switch zone and enter into above figure displayed windows interface. In above figure: “pinyin” location indicates current input method. This panel support Chinese pinyin input and big/small letter/digits input. Push down “Up” and “Down” cursor key to switch input methods. Now we show how we can input one line mixed Chinese, English and digits test. For example, if we want to input the text of “我的1997Tmd” ,this line text looks very strange, and it does not have any real meaning. We just want to use this example to show the input method. Start the input process 1、 If there is content in text area, please push down continuously “Silence” to delete the content; 2、 Push “up” and “down” cursor key and switch input method to “pinyin”; 3、 Push 9 key, cursor moves to “pinyin” line, “pinyin” behind shows “W”; 4、 Push 6 key three times until “pinyin” behind shows “wo”; 5、 Push 0 key, “pinyin” behind will show “挝蜗涡窝我斡卧握”;if the desired word is not shown in this line, the operator can use “left” and “right” cursor to turn over next page or previous page words list to choose the right desired word。 6、 Push “我”word location number 5 , the “我”word will be shown in text editing area and also the cursor will move to text editing area; Ok, we successfully input one “我”word. Although we just finish to input one word for desired one complete line words, we believe that you have some basic understanding of this input method. Maybe there are some questions, such as, the operator has input wrong word into the text line. For example, we want to push 6 to input “o”, but due to our mistake, we have pushed 3 and input “wd”, how to change it? Very simple, you just need to push “left” and “right” and move cursor to wrong letter character “d”, then push “silence” key and delete the wrong words or letters. In text editing area or pinyin input area, you can use this method to delete cursor pointed location characters.! 7、 Now we input “的” ,you should have some basic skills, so we want to use a series of keys to show the input process: push down 3 (wait for one moment, wait 3 3 0 3 。 for cursor t move to “d” behind, At this time, cursor should be at text editing zone, then switch input method 9 9 7 to digits, it is in “1234” status. Push 1 in turn. We believe this editing area content should be “我的1997”. There are three letters remaining! 8、 Switch input method to large and small letter, it is in “ABCD” status. Then 0 push 8 once again, we do not need to consider whether behind letter “t” 22 Wuxi Brightsky Electronic Co., Ltd JB-QB-5Li fire alarm control panel operation manual of “ABCD” is big letter or small letter, and after we come to text area, the letter will be large letter. 9、 Then switch input method to small letter, it is in “abcd” status. Then push 6 3 0 once again, at this time, in text editing area, it will show our desired line “我的1997Tmd”了,OK, successful, so you will have good feeling for the system! After editing equipment location, push “self-check” and confirm your modification. Then edit other number location once again, push “reset” to give up modified content and edit other numbers. Maybe there are some closer equipments. Or they are installed in same place or location. Such as, maybe in the one big room, there will be equipped with several fire detectors. And these detectors have different internal addresses. Under this example, if the operator wants to set up same location content for these several fire detectors. It will take time. So our panel has unique “location copy” function to help the operator solve this location description and setup issue. When cursor is in “location description” area, please push “menu” to enter into this function: 主菜单menu>>Device>>Location Main >>设备管理>>位置 You want 您希望把:一楼大厅 copy: 一楼大厅 001号至003号 From z.01复制到: no.001 01 to区no.066 自检-复制,消音-返回 [self-chk]-copy, [silence]-return Key code This function will mapping remote control module number into bus linkage operation card key number. Under this function, the operator can use keyboard to open and close remote control modules. So the operation can easily control the remote modules! Note: “No.001 of No.00 zone” indicates this key has not been mapped! Wuxi Brightsky Electronic Co., Ltd 23 JB-QB-5Li fire alarm control panel operation manual 主菜单menu>>Device>>KeyCode Main >>设备管理>>键号 键号 Key 0001 001: 0003 003: 0005 005: 0007 007: 0009 009: 0011 011: 0013 013: 0015 015: 模块号 Module z.01no.001 01区001号 号 z.01no.001 01区001号 01区005号 z.01no.005 区011号 z.01no.011 z.02no.001 02区001号 z.01no.001 01区001号 00区000号 z.00no.000 00区000号 z.00no.000 Key 键号 002 002: 004 004: 006 006: 008 008: 010 010: 012 012: 014 014: 016 016: 模块号 Module z.01no.002 01区002号 z.01no.002 01 区002号 z.01no.006 01 区006号 01 区012号 z.01no.012 z.01no.022 01 区022号 01 区002号 z.01no.002 00 区000号 z.01no.000 00 区000号 z.01no.000 1-edit, silence-return 1键-返回 If the operator wants to set up key number mapping relation once again, please push 1 key to enter into “key number editing” function。 主菜单menu>>Device>>KeyCode Main edit >>设备管理>>键号编辑 键 号:0001至to 0100 0100 号 KeyCode: z.05 no.001 Module: 模块号:05 区001 号起 startup -返回 [silence]-return [self-chk]-confirm, 复位 As shown in above figure: Key number range is from 1 to 100. Remote control module number stars from No.001 of No.05 zone. Therefore, No.1 to No.100 key will correspond with No.001 module to No.100 module of No.05 zone. Please note 2 questions: 1, If key number range is greater than module number range (this zone module maximal range is 250), only modules in the range can be mapped. For example, key number is from 1 to 100, module number stars from No.200 of No.05 zone, the ultimate mapping 24 Wuxi Brightsky Electronic Co., Ltd JB-QB-5Li fire alarm control panel operation manual relation is: No.1 to No.50 key has been mapped to No.200 to No.250 modules of No.05 zone, No.51 to No.100 key mapping does not change! 2, Please delete mapping relation which exceed push button actual numbers, for example, if the system just has 100 key buttons, the operator should set No.101 key corresponding module as No.0 of No.0 zone. Therefore, the mapping relation after No.101 will be invalid. If there is any special requirement to eliminate one key mapping relation in these 100 keys, the operator just need to set this key mapping relation as one very big, non-existent module number (after No.65 zone). For example, if No.1 key is broken, we need to jump this key, we just need to set its corresponding module number as No.001 of No.65 zone. History Log This control panel can record the latest 2000 pieces alarm and activation logs, including: fire alarm, fault alarm (detectors and system components), linkage operation activation, module feedback, reset and panel close, and so on. The time can be corrected to minutes. 主菜单menu>>Log Main >>历史记录 Total:2000 总数:2000 0001:fail[01-002] 0001: 01区002号 2002/10/25 2002/10/25 10:38 10:38 0002:故障 01总线联动卡 2002/10/25 10:37 10:37 fail[01] ControlCard 2002/10/25 0003:关机 Shut down 2002/10/25 2002/10/25 10:36 10:36 0004:复位 reset 2002/10/25 2002/10/25 10:35 10:35 0005:故障 Fail[02] 02号数据采集卡 multi-line 2002/10/25 2002/10/25 10:34 10:34 0006:应答 respn[01-008] 01区008号 2002/10/25 2002/10/25 10:33 10:33 0007:启动 start[01-008] 01区008号 2002/10/25 2002/10/25 10:32 10:32 0008:火警 Fire[01-002] 01区002号 2002/10/25 2002/10/25 10:31 10:31 0009:故障 Fail[01-001] 01区001号 2002/10/25 2002/10/25 10:30 10:30 startup 2002/10/25 2002/10/25 10:25 10:25 0010:开机 1键-打印,消音键 -返回 [1]-print, [silence]-return If the operator needs to print history logs, push record” function. Wuxi Brightsky Electronic Co., Ltd 25 1 key and enter into “print JB-QB-5Li fire alarm control panel operation manual 主菜单menu>>Log>>Print Main records >>历史记录>>打印记录 Print:No.0000 to 号至 00000000 records 您希望打印:0000 号记录 [self-chk]-print,[silence]-return -返回 Date and time Date and time show system date and time setup. Main 主菜单 menu>>Date & time >>日期时间 2002/11/05 13:42:00 -返回 [reset]-confirm,[silence]-return 复位 Linkage operation programming Linkage operation programming shows: after fire is confirmed, the system will do linkage operation activation work automatically. The control panel will follow 26 Wuxi Brightsky Electronic Co., Ltd JB-QB-5Li fire alarm control panel operation manual confirmed fire alarm message and activate corresponding equipments based on linkage operation edited logic relations. Note: in manual operation mode, all linkage operation setup is not valid! Main 主菜单 menu>>Program >>日期时间 > total:0002 cond.1 cond.2 action logic 01-001-010 02-001-010 03-001-005 OR1 01-011-020 02-011-020 03-006-010 OR2 01-021-030 02-021-030 03-011-015 AND 01-031-040 2002/11/05 02-031-040 13:42:00 01 ext OR1 01-041-050 02-041-050 02 ext OR2 01-051-060 02-051-060 03 ext AND 01-061-070 02-061-070 03-031-035 LOR1 01-071-080 02-071-080 03-036-040 LOR2 01-081-090 02-081-090 03-041-045 LAND -返回 1-add,2-del,3-edit,silence-ret 复位 page:000 Linkage operation relation has 3 logics: or 1, or 2, and, but based on different controlling condition and activation objects, there are 9 combinations: 1) Control condition is fire detector, control object is module, control logic is OR1, it is show in first information in above figure. 2) Control condition is fire detector, control object is module, control logic is OR2, it is show in second information in above figure. 3) Control condition is fire detector, control object is module, control logic is AND, it is show in third information in above figure. 4) Control condition is fire detector, control object is fire extinguishing zone, control logic is OR1, it is show in fourth information in above figure. 5) Control condition is fire detector, control object is fire extinguishing zone, control logic is OR2, it is show in fifth information in above figure. 6) Control condition is fire detector, control object is fire extinguishing zone, control logic is AND, it is show in sixth information in above figure. 7) Control condition is module feedback, control object is module, control logic is LOR1, it is shown in seventh information in above figure. 8) Control condition is module feedback, control object is module, control logic is LOR2, it is shown in eighth information in above figure. 9) Control condition is module feedback, control object is module, control logic is AND, it is shown in ninth information in above figure. Above seventh, eighth and ninth combination is link method to activate other modules based on module feedback signal。 In above figure, it uses OR1, OR2 and AND. Wuxi Brightsky Electronic Co., Ltd 27 JB-QB-5Li fire alarm control panel operation manual Now we use above figure first linkage operation editing information “01-001-010 02-001-010 03-001-005 OR1” line to explain this page expression format: “01-001-010” is condition 1 range, it shows No.001 to No.010 of No.01 zone alarm equipment; “02-001-010” is condition 2 range, it shows No.001 to No.010 of No.02 zone alarm equipment; “03-001-005” is activation range, it shows No.001 to No.005 modules of No.03 zone; “OR1”is logic relation type. It shows this information is OR1 logic. This complete information shows: If there is any one equipment which makes alarm from No.001 to No.010 of No.01 zone, or there is any one equipment which makes alarm from No.001 to No.010 of No.02 zone, No.001 to No.005 modules of No.03 zone should be activated. If the logic relation is OR2, such as “01-011-020 02-011-020 03-006-010 OR2” line, it shows: if there are any 2 equipments which make alarm from No.011 to No.020 of No.01 zone, or there are any 2 equipments which make alarm from No.011 to No.020 of No.02 zone, No.006 to No.010 modules of No.03 zone will be activated. If the logic relation is AND, such as “01-021-030 02-021-030 03-011-015 AND” line, it shows: if there is at least one equipment which makes alarm from No.021 to No.030 of No.01 zone, and there is at least one equipment which makes alarm from No.021 to No.030 of No.02 zone, No.011 to No.015 modules of No.03 zone will be activated. If the operator wants to delete programming information, push “up” and “down” key to move the cursor to desired deleting line, then push 2 key, this line will be marked as “*” number. It indicates that this line information has been deleted. Push 2 key once again, “*” will be eliminated. It indicates that this line information deletion has been cancelled. Push 1 key to add new programming records. 主菜单men>>Program>Edit Main 联动编程>>添加或1or 1 logic 逻辑关系 cond.1: 条件1 : z.01 01区 001 号至010 no.001 To 号 010 条件2 : z.02 02 no.001 号至010 To 号 010 cond.2: 动 作 : z.03 03区 no.001 001 005005 号 cctivate: To 条件 将启动“ 2中任意一个号码报警 ”范围内的设备 Reset-confirm,selfchk-change,silence-ret -确认,自检-改变逻辑关系,消音-返回 复位 28 Wuxi Brightsky Electronic Co., Ltd JB-QB-5Li fire alarm control panel operation manual System management Here, the operator can see main control panel connected data acquisition card total amount and numbers, multi-line linkage operation card total amount and numbers, and printer setup condition (if it is in real time printing status), and other options Push “left” and “right” cursor key to turn over to previous page or next page option。 主菜单menu>>System Main >>系统管理 Extension total 分机(数据采集卡及区域机)总数 总线联动卡总数 Bus control card total 多线联动卡总数 Multi-line control card total 灭火功能卡总数 Fire extinguishing card total 火灾显示盘总数 fire repeater total 区域机起始号码 zone panel incept number 开机时搜索以上设备 open panel search above device 允许实时打印 allow real-time print 监控火灾显示盘 monitor fire repeater Page:00 页:00 :08 :01 :01 :01 :10 :05 :enable :不必 :disable :不必 :disable selfchk-change status, silence-ret 11-det, -返回 键-详情,自检 In above figure: “extension:08” :indicates there are 8 pieces data acquisition cards or zone alarm control panels, push 1 key to refer detailed numbers. “bus control card total:01” indicates there is one bus linkage operation main card currently connected into this system, push 1 key to refer detailed numbers. “multi-line control card total:01” indicates there is one multi-line linkage 1 operation card currently connected into this system, push key to refer detailed numbers. “fire extinguishing card total:01” indicates there is one fire extinguishing function card currently connected into this system, push 1 key to refer detailed numbers. “ fire repeater total : 10 ” indicates there are 10 fire repeaters currently connected into this system, push 1 key to refer detailed numbers. “zone panel incept number:05”:indicates zone alarm control panel starts from No.5 extension. No.1 to No.4 extension are data acquisition cards. Wuxi Brightsky Electronic Co., Ltd 29 JB-QB-5Li fire alarm control panel operation manual System requirement:if this panel is used as central control panel in central-zone method and there are data acquisition cards installed in the panel, the data acquisition card number is ahead. The zone panel number is behind. The operator should set up the zone panel incept number, for example, in above figure, No. 5, No.6, No.7 and No.8 are zone panels. Why should we do in this way? There are two reasons: 1、 Help the system to identity zone panels and data acquisition cards. 2、 Each zone panel just has one zone/loop. Each data acquisition card has 2 zones/loops. If we do not figure the zone panels and data acquisition cards, it will make confusion for zone numbers arrangement!For example, above No.7 extension zone number is 11, not 13 and 14. “open panel and search above equipments” :indicates whether the main panel need to search extensions, bus linkage operation card, multi-line linkage operation card and other system components when the operator opens the panel for each time. If the operator chooses “enable” , after the main panel is open, it will go through all process for each time. It is time consuming!We recommend, if the system connected components have been changed or modified, we can set this function as “enable” , after keep the modification information and close down the panel, open the panel once again and set this function as “disable” ! Note: If the system is open for the first time and it does not implement components searching function during the Initialization, the operator should set this function as “enable” ,keep the function and information and close down the panel and open the panel once again! Otherwise, the main control panel will lose the control to all system components. This function can also be used to isolate communication fault system components. If the component cannot be normally connected with the main control panel, the operator should use re-searching and release this component from logic relation temporarily to avoid the situation that the main panel always sends out fault information! “allow real-time print” , it can set as “disable” or “enable”. If it is set as “disable”, when there is fire alarm or fault, the information will not be real time printed out. But it does not have impact on black box’s printing function. “monitor fire repeater” ,it can set as “enable” or “disable”. If it is set as “disable”, the main panel does not monitor system connected fire repeaters. That is to say, if there is link fault between fire repeaters and main panels, it cannot be reflected in main panel. “polling equipment under menu status” ,it can be set as “enable”, if the system is under menu item condition and there is fire alarm or linkage operation activated (excluding fault), the system will send out information immediately rather than wait to manually return to monitoring status to send out information! “close LCD back light in idle”also has two options: “enable” or “disable”. If it is set as “enable” and system works as normal and there is no key push operation, in 20 minutes, the LCD back light will be closed! After the LCD back light has been closed, if there is any alarm or key button operation, the back light will be activated automatically! 30 Wuxi Brightsky Electronic Co., Ltd JB-QB-5Li fire alarm control panel operation manual “activate windows screen protection program in idle” ,it can be set as “enable” or “disable”. If it is set as “enable” and the system works as normal and there is no key button operation, in 5 minutes, the windows screen protection program will be activated ! Return monitoring It indicates that the system and panel has return to monitoring status System self-check System self-check is test system LCD display screen, status LEDs and sounders. In polling status, push “self-check” to enter into this function。 系统测试test System Test sound … …… 测试音箱 测试指示灯 Test LEDs … …… During self-check process, the control panel front LEDs will flash and sounders will send out ambulance sound and the printer will print out Brightsky Electronic marking. After the self-check is completed, it will return to monitoring status automatically. Locker key/Lock release To avoid non-authorized person mishandle, this control panel has locker key function. In monitoring status, push locker key button to enter into this function. Wuxi Brightsky Electronic Co., Ltd 31 JB-QB-5Li fire alarm control panel operation manual 权限控制rights control Access Please input keyboard lock password 请输入键盘闭锁口令 >: : **** Input keyboard lock password. If the password is correct, lock key LED will be illuminating. After the keyboard has been locked, it just can allow to do silence and lock releasing. It does not allow to do other works. If the operator wants to release the locking function, he just need to push lock key button, in this situation, the windows interface will display” please input lock release password”. Automatic/Manual switch This control panel has automatic/manual switch function. In manual condition, all linkage operation logic relations are invalid. That is to say, linkage operation equipment cannot follow fire alarm number and be activated automatically. Automatic/manual status function switch is implemented via control panel front right down side hardware lock. Turn the key to make switch. If the system is in manual status, the manual status LED will be illuminating. If the system is in automatic status, the automatic status LED will be illuminating. If the 2 LEDs are both illuminating or both extinguished, it indicates the lock is broken. Please replace it with new lock! Linkage operation control We can use bus linkage operation card key to open or close modules. We also can use system’s linkage operation control function to open or close modules. But we do not recommend the second method. It is not so direct and easy! In normal monitoring status, push 2 key to enter into this function. 32 Wuxi Brightsky Electronic Co., Ltd JB-QB-5Li fire alarm control panel operation manual 联动控制 Associated Operation Control :03区001 003号 模块号 Module: z.00 no.000 to号至 no.000 复位键-关闭,自检键 reset-close, selfchk-startup, -启动,消音键-silence-ret 返回 Refer isolation This refer is one simply way for “main menu>>equipment management>>isolation”. Its purpose is make user easily to see current system isolated equipments in normal monitoring status. It does not need to go through a series complicated operations, such as password verification and so on! In normal monitoring status, push 1 key to enter into this function. Its windows display interface is similar as “main menu >>equipment management>>isolation”. The last line is changed. We do not show it here once again. Ethernet function 5Li system has exciting Ethernet network function. It just needs to plug one special-made network interface card. The control panel can be used as one network terminal to be connected into Ethernet net. In the net, any terminal which has installed control software can receives the panel’s information and make remote control to the panel. Screen protection This control panel screen protection function will make you feel SCM chip’s wonderful charm! Beautiful Tai-hu Lake——This is our greeting! Continuous enterprising——This is our spirit! Brave to the Sky——This is our target! Our service Wuxi Brightsky Electronic Co., Ltd 33 JB-QB-5Li fire alarm control panel operation manual The control panel operator should be trained by our company. After the operators pass our training courses, they can do the operation. Concerning some basic maintenance, the trained persons can do it. If there is any abnormal situation during the system operation, please make telephone to our after-sale service engineers. Or, we can come to your system site to make service. In addition, you can visit our company website www.bsky.cn to get our company development information and read the product catalogues and technical information. Special Wuxi Brightsky Electronic Co., Ltd follows continuous development strategy. So we reserve the rights to modify our products and technical specifications and these modifications do not need to inform our customers in advance. The copyright of this operation manual belongs to Wuxi Brightsky Electronic Co., Ltd. 34 Wuxi Brightsky Electronic Co., Ltd