SOLITAIRE PHARMACIA PVT. LTD. RESTRICTED CIRCULATION AUTHORISED PERSONS ONLY STANDARD OPERATING PROCEDURE Title: Leak test of unit packs Title: Entry/Exit Procedure for Manufacturing Area Prepared By Concerned Dept Checked By Concerned Dept Prepared By Objective Checked By 1. Concerned Dept Concerned Dept SOP. No. : SPL/ SOP/PR/018 Page No. : 1 of 2 Supersedes SOP. No. : New HLM/ SOP/MF/001 Revision Page No. No. : 00 1 of 5 Reviewed By QA Approved By QA-Head Effective Date : Supersedes Review Date New Revision No. 00 Reviewed By QA Approved By QA-Head Effective Date : Review Date To define the procedure for Leak test of unit packs. 2. Scope This procedure is applicable to all Products of Solitaire Pharmacia Pvt. Ltd., Baddi. 3. Responsibility Production supervisor: Implementation of SOP & documentation. 4. Accountability Head- Production 5. 5.1 Procedure For Strip & Blisters: Start & every two hours. 5.1.1 Fill the leak test apparatus up to its half capacity (As marked) with water and add 50 to 60 ml. of 1 % w/v aqueous solution of sodium lauryl sulfate & 10 to 12 ml. of 10 % w/v Methylene blue solution in to it (for 2 liter water). 5.1.2 Collect sealed blisters/ strips directly from the machine ensuring representation of all pockets of strip / blister sealing rollers. 5.1.3 Put the samples along with some weight in to the leak test apparatus and ensure complete submerging of blister / strips in to water. 5.1.4 Cover the leak test apparatus with lid; connect rubber tubing of vacuum line with leak test apparatus. 5.1.5 Adjust the vacuum valve and run the vacuum minimum till the vacuum gauge indicates 380 mm / 15 inch mercury and maintain the vacuum for 2 minutes. 5.1.6 Detach the rubber tube from leak test apparatus; keep it for minimum one minute. 5.1.7 Remove the lid and take out blisters/ strips. Wipe dry with clean dry cotton cloth. 5.1.8 Cut, open the blisters / strips and examine tablets/ capsules inside carefully. 5.1.9 All pockets should pass leak test. In case of any failure stop the machine and adjust pressure / temperature of sealing roller. Format No.SPL/QA/001 SOLITAIRE PHARMACIA PVT. LTD. RESTRICTED CIRCULATION AUTHORISED PERSONS ONLY STANDARD OPERATING PROCEDURE Title: Leak test of unit packs Title: Entry/Exit Procedure for Manufacturing Area Prepared By Concerned Dept Checked By Concerned Dept Reviewed By QA Approved By QA-Head SOP. No. : SPL/ SOP/PR/018 Page No. : 2 of 2 Supersedes SOP. No. : New HLM/ SOP/MF/001 Revision Page No. No. : 00 2 of 5 Effective Date : Supersedes Review Date New Revision No. 00 : 5.1.10 leak By test in startReviewed & everyBytwo hours.Approved RecordBy observations in batch record. Prepared By Conduct Checked Effective Date packingReview Date Concerned Dept 6. Concerned Dept QA QA-Head Records/Formats: NA 7. Annexure: NA 8. Reference: Nil 9. 10. Abbreviations: SPL - Solitaire Pharmacia Pvt. Ltd., Baddi. SOP - Standard Operating Procedure QA - Quality Assurance N.A - Not Applicable. PR - Production W/v - Weight/Volume Revision History: Revision No 00 Format No.SPL/QA/001 Effective date Reason for Revision New Document