BZC Features Benefits - Herrmann Associates Inc.

advertisement
Features/Benefits of the ROBERTS
GORDON® BZC CONTROLLERS
The Cutting Edge Building Zone Controllers for ROBERTS
GORDON® Infrared Heating Equipment
Feature
Benefit

Provides maximized fuel savings.


Reduces installation cost.
Provides centralized energy management.

Provides centralized energy management for
multiple offsite locations.

Provides design flexibility.

Self Learning Optimization – controller will optimize the
start up to meet the target temperature precisely at the
beginning of every occupancy period
One controller controls multiple zones and pumps
Multiple controllers (ROBERTS GORDON® BZC 300 &
BZC 700) can be connected to a single remote PC where
data can be viewed and settings altered
Multiple controllers (ROBERTS GORDON® BZC 300 &
BZC 700) can be connected to an optional modem
connection so data can be viewed and settings altered
from an offsite location
Controllers can control the complete range of ROBERTS
GORDON® infrared heating products
Detailed Programming Guide at Controller Level


Detailed Installation and Operation manuals


Security Coding


Building Management System Time Enable


Electronic Air Temperature Sensors employed in every
heating zone


Temperature Monitoring


Zone Temperature Override


Hours Run Monitoring


Five Programmable Holiday Periods


Four Time Switching Periods Per Day

Reduces installation and operation time;
provides easy access to programming.
Reduces installation time and errors; easier to
troubleshoot and repair.
May be enabled to eliminate unwanted
tampering with controller.
Allows an existing Building Management
System to control the day/night switching
periods resulting in reduced programming
time.
Provides accurate air temperature readings;
eliminates tampering that can occur when
using thermostats.
Allows user to review temperature history for
all zones; records temperatures sensed in
every zone in 15-minute intervals; saves a 24hour history.
For random occupancy periods, user can
override setpoint temperature to day
temperature or to night temperature for up to
an 8-hour period.
Allows user to estimate fuel usage based on
hours run information; records running hours
for each relay weekly; saves a four week
history.
Assures energy savings during unoccupied
holidays
Allows up to four-day periods and four night
periods per day to satisfy virtually any building





occupancy schedule.
Feature Continued
Benefit Continued

7-Day Time Clock


Digital Inputs


Two Temperature Settings


Night Setback


Display of Current and Set Point Temperatures


Backlit LCD Display



Display of Heater Status
Pump Trip Indication





Zone Lockout Indication (Burner must be fitted with a volt
free relay for this function)
Fire Safety Shut-Off

Vacuum Proving (CORAYVAC® only)


10-Year Battery Backup


UL and CE certified

Roberts-Gordon
1250 William Street
P.O. Box 44
Buffalo, New York 14240-0044
Telephone: 716.852.4400
Fax: 716.852.0854
Toll Free: 800.828.7450
http://www.rg-inc.com
BZCFBNA

Easy pre-programming of a 7-day event
sequence. Each zone can be programmed
independently of others.
12V DC inputs can be assigned to receive
status signals from burners. Inputs include
vacuum proving switch status, heater lockout
indication, fire safety shut-off and BMS time
enable.
One setting for a daytime temperature and
another for nighttime (setback) temperature.
Night setback temperature can be set for
unoccupied periods to maximize fuel savings.
Easy viewing of temperatures in every heating
zone.
Easy viewing of programming screens. Back
light will turn off when the unit has not been
used for 5 minutes to save on power
consumption.
Quick verification of zone's ON or OFF status.
Display will show if the pump overload has
tripped.
Display will indicate lockout if any burner in
that zone has failed to light.
All heating zones are disabled when fire safety
shut off signal is received.
As an extra safety precaution, the pressure
switch at the vacuum pump must prove in both
open and closed positions. This feature
disables the heater if pressure switches have
been tampered with.
Eliminates need for re-programming in the
event of a power failure.
Independent testing to industry standards.
Roberts-Gordon
76 Main Street West
Unit 10
Grimsby, Ontario L3M 1R6
Telephone: 905.945.5403
Fax: 905.945.0511
Printed in USA
6/02
Download