Pond Pump WP1000E- fountain pump Gallons per hour-342 Wattage-7.5 Maximum Head-3.93’ Outside dimensions: 13” L x 6” W x 4.625” H Cord Length: 16’ WP2000E-fountain pump Gallons per hour-600 Wattage-20 Maximum Head-4.92’ Outside dimensions: 15.75” L x 7”W x 6.5” H Cord Length: 16’ Parts list for WP1000E Fountain Head 1.b 1. Three tier head Option 1 2. 2 tier head Option 2 3. Water bell Option 3 4. Fountain head uplift tube adapter 5. Fountain head adapter 6. Uplift tubes 7. Uplift tube reducer 8. valve and water diverter 9. Diverter cap 10. Main prefilter cap 11. Additional prefilter bracket 12. Pump strainer 13. Impeller cover 14. Impeller 15. Pump 16. Additional prefilter 17. Main prefilter Parts list for WP2000E Fountain Head 1.c 1. Water bell 2. three tier 3. Dual three tier 4. Coupler 5. Uplift tube 6. valve and water diverter 7. Diverter cap 8. Additional prefilter bracket 9. Pump strainer 10. Impeller cover 11. Impeller 12. Pump 13. Additional prefilter 14. Main prefilter For use in freshwater environments Instructions for installation and operation Important Before installation of a ViaAqua Multi-duty pond pump, please read and follow these important safeguards and safety guidelines. Do not operate ViaAqua® pump without being fully submersed at all times. Doing so can cause permanent damage to the pump. Do not reduce the intake or output tubing size The national code requires that all pond equipment be plugged directly to a GFCI electrical outlet. Consult an electrician Never operate a ViaAqua® pump with an electronic wave maker or on/off timing device. As such devices will cause permanent damage to the pump and/or demagnetize the impeller. Prior to maintenance on any electrical aquarium appliance or maintenance to the pond, you must disconnect all electrical aquarium devices. When operating a ViaAqua® pump inside a pond or a fountain the large prefilter must be used. Failure to use prefilter will cause damage to the impeller and/or pump. Routine maintenance is required to insure the maximum performance and the longevity of the ViaAqua® pump. See maintenance guidelines The use of a surge suppressor is strongly recommended. Application submersed operation Follow all safeguards and safety guidelines a. Verify that the pump size fits the application without dramatically restricting the flow. Consult with your local dealer or manufacture’s guidelines for the size pump needed for your specific application. b. Do not reduce the input or output diameter of the pump c. You must incorporate the prefilter when operation for a water circulation, waterfalls, ponds and fountains. d. Replace the impeller if there are any signs of damage or excess wear. e. Failure to maintain a ViaAqua pump will cause permanent damage to the impeller and/or pump. Routine maintenance is of the utmost importance to keep you pump working well. Internal operation with fountain head a. Connect the additional prefilter to the main prefilter. See diagram 1. Open both clasps. 2. Now open the main prefilter 3. Connect the additional prefilter to the main prefilter 4. Close main prefilter 5. Secure both clasps b. Place pump in desired location 1. If placed in a pond: Raise the pump off the bottom of the pond by a min. of 6 inches when installing c. See diagram 1.b for model WP1000E and 1.c for model WP2000E for fountain head set up d. Diverter valve enables water flow to be directed to either a water feature, terminator UV sterilizer or a pond filter. Helpful hints: Since there are many manufactures of filtration systems, please refer to the manufactures instructions for installation and guidelines. Float valves will sure a consistent water level at all times. See your local dealer for more information Maintenance: Routine maintenance is required every 30 days. a. Disconnect the pump from the GFCI power supply prior to removing the pump from the water b. Open both clasps c. Remove pump from main prefilter d. Clean all prefilter e. Remove the impeller well cover. f. Once the impeller well cover is removed, slide both the impeller and shaft out of the main body of the pump and clean well. Please not do not use any soap detergents during cleaning. g. After the impeller and shaft are cleaned, use a small brush to clean inside of the motor housing. h. Reassemble above parts and your ViaAqua® pump is again ready to use. Confirm that all the washer and bushing a reassembled properly. Failure to do so will cause permanent damage to the pump. i. Insert back into main prefilter and attach additional prefilter It the water flow is to decrease it is a clear sign that debris is in the impeller well or the prefilter is clogged. It is the aquarist’s sole responsibility to ensure the pump is maintained. Failure to do so will cause permanent damage to the pump. Pond Precautions: Plug the pump into a GFCI outlet Before any maintenance on the pump or pond unplug all electrical components Never yank/pull the pump by the cord. Failure to follow this guideline will cause the pump to fail prematurely and or cause electrical shock. Never reduce the intake or the output pipe diameter When installing raise the pump a min. of 6”-12” from the bottom of the pond. Due to the extreme conditions of a pond frequent cleaning of the prefilter and pump are needed. If the intake of the pump is to clog and is not remedied it will cause the pump to fail prematurely. Note it is the hobbyist sole responsibility to insure a clean pond or water feature failure to do so will cause premature failure of the pump. Note it is the hobbyist sole responsibility to insure the GFCI electrical outlet is free of water, calcium deposits, and magnesium deposits and or moisture failure to do so will cause electrical shock and or fire. Limited Warranty Commodity Axis Inc. warrants that ViaAqua water pump is free from defects for a period of one year from the initial date of purchase shown in the original cash register receipt. Commodity Axis Inc. disclaims all other warranties of merchantability and/or fitness for a particular purpose. Although this limited warranty gives you specific rights, you may have other rights that may vary from state to state. This Warranty is void if the failure of the ViaAqua water pump or any part, sealant or component there of is due to (i) misuse, (ii) tampering, (iii) negligence, (iv) misapplication, (v) abuse, (vi) accident and/or (vii) failure to properly (a) maintain, (b) clean, (c) proper bulbs, (d) reassemble, (e) keep unit from coming in contact of water and/or use the ViaAqua water pump with a Ground Fault Circuit Interrupter (GFCI) Consumer Remedies Commodity Axis Inc. entire Liability and your sole exclusive remedy be, either repair or replacement of the ViaAqua water pump only if you return the defective ViaAqua water pump directly to Commodity Axis Inc. with the original receipt in this original box along with $15.00 for shipping and handling. Do not send the ViaAqua water pump by insured mail. The ViaAqua water pump may be sent by UPS requiring signature upon arrival. Any replacement ViaAqua water pump will be warranted for remaining of the original warranty period. In not event shall any shipping charges be reimbursed. In no event will Commodity Axis Inc. be liable for any consequential or incidental damages including, but not limited to, loss of life, personal injury, property damage, damaged equipment, lost profits, lost wages, lost savings, lost income, etc. arising out of the use of the ViaAqua water pump. Some states do not allow for the limitation or exclusion of liability for incidental or consequential damages, so the above exclusion may not apply to you.