APPENDIX C – DATA SHEETS
ELECTRIC VALVE ACTUATORS
PROJECT TITLE (P)
DOCUMENT REFERENCE
(P)
REVISION (P)
DATE (P)
REFERENCE DRAWINGS
(P)
PROJECT NUMBER (P)
PROJECT LOCATION (P)
ACTUATOR
SUPPLIER
(P/S)
(included/not
included)
* - indicates Purchaser’s default requirements
4.0 VALVE AND ACTUATOR TYPE AND DUTY
3.0 OPERATING ENVIRONMENT AND SITE
DETAILS
1
3
Operating Environment (P)
Site Location ()
Inland
Coastal
Actuator Location ()
Inside
Outside
Above ground level
Below ground level
Other (specify)
Corrosion Category ()
C2 (low)
C3 (medium)
C4 (high)
C5-I (v. high - industrial)
C5-M (v. high - marine)
Hazardous Area Classification ()
None
Zone 1
Zone 2
EMC Environment ()
C1
C2
C3
Special Service Conditions or
Hazards (P)
4.1 Valve Type and Duty
1
2
3
4
Other
5
4
References For Further Information (P)
6
7
ISSUE 3
Valve Type () (P/S)
Rotary (part turn)
Linear (multi-turn)
Penstock
Other (specify)
Type of Stem Movement (Linear Valves
and Penstocks () (P/S)
Non-rising stem
Rising stem
Valve Shaft, Stem or
Gearbox Input Shaft
Diameter (mm) (P/S)
Required Valve Duty () (P/S)
Rotary (Part-Turn) Valve
On-off (cycles/hour)
Inching (starts/hour)
Modulating (starts/hour)
Linear (Multi-Turn) Valve
On-off
(running
time/hour)
Inching (starts/hour)
Modulating (starts/hour)
Penstock
On-off
(running
time/hour)
Inching (starts/hour)
Modulating (starts/hour)
Maximum
Torque
Required to Operate
Valve (Nm) (P/S)
Maximum
Thrust
Required to Operate
Valve (N) (P/S)
Maximum
Allowable
Structural Torque/Thrust
(Nm) or (N) (P/S)
JANUARY 2014
WIMES 3.08
8
Required Operating Time or Speed (P/S)
Operating time (s/90o)
(rotary valves)
Operating speed (mm/s
or
mm/min)
(linear
valves and penstocks)
Page 28
6.1.4 Corrosion Protection
2
Protective Coating Colour () (P)
Supplier’s standard
Other (specify)
6.1.7 Information Plate
4.2 Actuator Type and Duty
1
1
1
Actuator Type () (S)
Part-turn
Multi-turn
Linear (multi-turn)
Actuator Duty Classification () (S)
Class A – on-off
Class B - inching
Class C - modulating
Class D – continuous
modulating
5.0 PERFORMANCE SPECIFICATION
6.1.8 O & M Manuals
1
1
Rated
Actuator
Torque/Thrust (Nm) or
(N) (P/S)
5.5 Rated Operating Time and Speed
Vandal Resistant Cover
Required (Y/N) (P)
6.2 Mounting Arrangements
1
5.4 Rated Torque/Thrust
1
Type () (P)
Supplier’s standard
Purchaser’s standard
(specify reference)
6.1.9 Miscellaneous
5.1 Service/Design Life
Service/Design Life (Years)(P/S)
Service life (P)
Design life (S)
Additional Information Required on Plate
(P)
Type () (P)
Mounted directly onto
valve
Remotely mounted
6.3 Enclosure
2
3
Operating time (s/90o)
(S)
Operating speed (mm/s
or mm/min) (S)
IP 68 Rating Required
(Y/N) (P)
Method of Adjusting Limit Devices and
Configuring Indicator Contacts (P/S)
Non-intrusive
Intrusive
6.4 Drive
6.0 DESIGN SPECIFICATION
6.4.1 General
6.1 General
2
6.1.2 Weights
4
1
Weights (kg) (S)
Actuator
Heaviest maintenance
lift
Heaviest erection lift
ISSUE 3
4
5
Plastic
Stem
Tube
Required (Y*/N) (P)
Integral VSD Required/
Provided (Y/N) (P/S)
VSD on ETL List (Y/N)
(S)
UPS Required (Y/N) (P)
JANUARY 2014
WIMES 3.08
6.4.2 Motor
1
4
Supply Voltage () (P/S)
400 V, 3 phase
230 V, single phase
110 V, single phase
24 V DC
Other (specify)
Type of Over-Temperature Protection
Provided () (S)
Thermostats
Thermistors
6.4.3 Integral Reduction Gearbox
4
Lubricant Type and Manufacturer (P/S)
5
Gearbox to be Sealed
For Life (Y/N) (P/S)
Method of Thrust Bearing Lubrication ()
(S)
Sealed for life
Re-greasing facilities
6
6.4.4 Second Stage Gearbox (If Provided)
1
6.6 Wiring, Terminals and Earthing
6.6.2 Terminal Enclosure
2
2
Method of Engaging
Handwheel (Declutching
of Motor Drive*) (P/S)
1
6.7.1 General
3
4
4
6.7.2.2 Local Indication
1
2
3
Pulsed
Operation
Required/Provided (Y/N)
(P/S)
Valve Position Sensing/
Updating
to
be
Maintained on Loss of
Power (Y/N) (P/S)
Method of Maintaining Valve Position
Sensing/Updating Capability () (P/S)
Internal battery
Other (specify)
6.7.2 Local Control and Indication
6.5.1 Motor Starter
Type Required/Provided () (P/S)
Three phase, reversing
Single phase reversing
Solid state
Not required
Other (specify)
Additional Features Required/Provided
(P/S)
Actuator Bonding Facilities (S)
6.7 Control and Monitoring
6.5 Motor Starter and Control Circuits
1
No. of Cable Entries
(P/S)
Cable Entry Details (P/S)
6.6.3 Earthing and Bonding
Provided (Y/N) (S)
6.4.5 Manual Operation of Drive
2
Page 29
2
4
Method of Indicating Valve Position ()
(P/S)
Electronic display*
Mechanical
Display to be Capable of
Maintaining/Updating
Valve Position on Loss
of Power (Y/N) (P/S)
Method of Maintaining/Updating Valve
Position on Display () (P/S)
Internal battery
Other (specify)
LED Indicator Colours and Meanings
(P/S)
6.5.2 Control Circuits
2
‘Rating of Power Supply
for External Indication
/Monitoring Circuits (S)
ISSUE 3
5a
Status Information to be
Available
Local
to
Actuator (Y/N) (P/S)
JANUARY 2014
WIMES 3.08
5b
Historical
Operating
(P/S)
Page 30
Data
Valve
(Y/N)
5
Actuator Torque Monitor
(4-20 mA) Required/
Provided (Y/N) (P/S)
6.7.3 Remote Control and Monitoring
*Specify whether contact is NO or NC
6.7.3.1 General
6.7.4 Diagnostics
1
1
Fieldbus Compatibility
Required/Provided (Y/N)
(P/S)
Communications Protocol(s)
Provided (P/S)
1
Required/
6.7.5 Torque and Position Limit Devices
6
6.7.3.2 Remote Control
1
2
3
3b
3c
4
Diagnostic
Module
Required/Provided (Y/N)
(P/S)
Control Circuit Supply Voltage () (P/S)
Internal, 24 V DC
External, 60-120 V ac
External, 20-60 V DC
Additional Functions Required/Provided
(P/S)
Extra Limit Devices
Required (Y/N) (P)
8.0 COMMISSIONING
1
Commissioning Tools Provided (S)
Two-Wire
Current
Position
Controller
Required (Y/N) (P)
4 and 20 mA to
Correspond to Fully
Closed and Fully Open
Positions (Y*/N) (P)
Controller Repeatability
(Within 1.0 %*) (P)
PID Controller Required
(Y/N) (P)
6.7.3.3 Remote Monitoring
1
Signals Required/Provided* () (P/S)

Valve fully open

Valve fully closed

Valve in an intermediate
position

Auto
available/unavailable
4
Valve Position Monitor
(4-20 mA) Required/
Provided (Y/N) (P/S)
ISSUE 3
JANUARY 2014
WIMES 3.08
Page 31
APPENDIX D – SUPPLIER’S SUPPLEMENTARY DATA SHEET INFORMATION
Clause
ISSUE 3
Supplementary Information
JANUARY 2014
Download