CableLabsīī Specification Engineering Change (EC) Form Project EC TRACKING INFORMATION (Blue fields to be completed by CableLabs only) DOCSIS N Identifier MULPIv3.1-N-14.1183-2 Status Affected Specification ECR Date ECO Date ECN Date ECN Effective Date CM-SP-MULPIV3.1-I03-140610 8/13/2014 Comment Period End Date 8/27/2014 SEVERITY 8/27/2014 Comment Period End Date 9/10/2014 Non-Critical 9/10/2014 114 Critical Cert Wave No Overall Type of Change (Tech/Edit/Both) Both Version 2 CHANGE TYPE Minor Major TO OBTAIN LATEST ISSUED SPECIFICATION WORD VERSION, CLICK HERE: https://www.cablelabs.com/doczone/docsis/requirements/specs/current/issued/ TO SUBMIT EC, EMAIL COMPLETED FORM TO: docsis_ec@cablelabs.com SPECIFICATION DOCUMENT DETAILS Document EC is written against: CM-SP-MULPIv3.1 Issued Version # I03 AUTHOR INFORMATION Primary Author Email Company Additional Contributors First Charaf Last Hanna charaf.hanna@st.com STMicroelectronics Margo Dolas, Bruce Currivan, Lisa Denney Title of EC Date sent to CableLabs Update OPT-REQ, OPT-RSP, OPT-ACK August, 12th 2014 Date of revised EC Brief description of revision 8/27/14 Figure corrected Country Phone USA 972-466-7573 ENGINEERING CHANGE DOCUMENT DETAILS EC REVISION HISTORY DETAILED PROPOSED CHANGES Sections Affected REQs Affected 6.4.4.3; 10.4.1 No Test Plans Affected No OTHER RELATED ENGINEERING CHANGES (LIST ALL THE APPLY) The following EC(s) are recommended to be processed in conjunction with this document: EC# Title of EC Affected Document NOTE! IMPORTANT EC AUTHOR INSTRUCTIONS: For an ECR to advance to ECO status: - Requirements Affected section of the embedded DOCSIS-SpecDetailChange.docx must be completed. - If applicable, the embedded TestPlanDetailChanges.docx must be completed. For an ECO to advance to ECN status: - If applicable, compiled MIB files and final Schema docs must be attached before requested changes can move to ECN status and noted as attachments in the table directly below. DOCSIS_3.1_Spec-TestPlan_EC-Form_6-2014.docx 1 of 3 In submitting the Engineering Change Request ("ECR"), the Author(s) [primary author, additional authors, and contributors], individually and as an authorized representative of the Company, agrees that if CableLabs incorporates this ECR in whole or in part into the relevant Specification, all intellectual property in the ECR shall be licensed royalty free, and without confidentiality, under the terms of the "Data Over Cable Service Interface Specifications License Agreement" ("Contribution Agreement"). CableLabs may disclose the content of this ECR to CableLabs' members and such others as is necessary for the development of CableLabs' specifications. Questions about the Authors' licensing of intellectual property in this ECR submission may be directed to legal@cablelabs.com. This Engineering Change has the following file(s) attached. Type of Attachment(s) (Visio, Word, txt, .yang, etc.) File Name of Attachment(s) Word EC_changes_for_OPT.docx DETAILED DESCRIPTION OF PROBLEM: OPT-REQ: Transaction ID adds unnecessary implementation and testing complexity; to be deleted (reserved field) RxMER TLV compounded multiple parameters, for clarity it has been broken into sub-TLVs Maximum NCP LDPC Unreliable Codeword Count has been deleted from the PHY spec Maximum NCP CRC Failure Count: counting NCP codewords doesn’t match the PHY spec, need to count NCP fields Out of date with respect to the changes in OPT-RSP status below OPT-RSP: Transaction ID adds unnecessary implementation and testing complexity; to be deleted (reserved field) Second OPT-RSP Incomplete status does not distinguish between Max Duration Expired and Aborted Nulled subcarriers used but not needed Uncorrectable Codeword Count: Definition not matching PHY spec Unreliable NCP Codeword Count has been deleted from the PHY spec NCP CRC Failure Count: counting NCP codewords doesn’t match the PHY spec, need to count NCP fields CM requirement for pass/fail result has been dropped but it remains in the text OPT-ACK: Transaction ID adds unnecessary implementation and testing complexity; to be deleted (reserved field) Downstream Profile Usability Testing Process Text and figures no longer in line with above changes in OPT-REQ, OPT-RSP, and OPT-ACK CM OPT State Machine (figure 10) is too complicated. Simplification provided using three states. DOCSIS_3.1_Spec-TestPlan_EC-Form_5-2014.docx 2 of 3 In submitting the Engineering Change Request ("ECR"), the Author(s) [primary author, additional authors, and contributors], individually and as an authorized representative of the Company, agrees that if CableLabs incorporates this ECR in whole or in part into the relevant Specification, all intellectual property in the ECR shall be licensed royalty free, and without confidentiality, under the terms of the "Data Over Cable Service Interface Specifications License Agreement" ("Contribution Agreement"). CableLabs may disclose the content of this ECR to CableLabs' members and such others as is necessary for the development of CableLabs' specifications. Questions about the Authors' licensing of intellectual property in this ECR submission may be directed to legal@cablelabs.com. CHANGE DETAILS FOR THE SPECIFICATION: Complete Engineering Change details for the specification are contained in the following embedded files: EChange_ MULPIv3.1013.1183-2.docx End of Request DOCSIS_3.1_Spec-TestPlan_EC-Form_5-2014.docx 3 of 3 In submitting the Engineering Change Request ("ECR"), the Author(s) [primary author, additional authors, and contributors], individually and as an authorized representative of the Company, agrees that if CableLabs incorporates this ECR in whole or in part into the relevant Specification, all intellectual property in the ECR shall be licensed royalty free, and without confidentiality, under the terms of the "Data Over Cable Service Interface Specifications License Agreement" ("Contribution Agreement"). CableLabs may disclose the content of this ECR to CableLabs' members and such others as is necessary for the development of CableLabs' specifications. Questions about the Authors' licensing of intellectual property in this ECR submission may be directed to legal@cablelabs.com.