SECTION 15152 FREQUENCY SPECIFIC ACOUSTIC ABSORBER (FAST Panel 1”) PART 1 GENERAL 1.01 SECTION PARAMETERS A. B. 1.02 PRODUCTS INSTALLED BUT NOT SUPPLIED UNDER THIS SECTION A. 1.03 Wood or metal mounting battens. RELATED SECTIONS A. B. C. D. E. F. 1.04 A frequency specific tuned acoustic absorber/diffuser, Model FAST Panel Interfacing with all trades and services having components that mount to, penetrate through or are concealed in, behind, below or above the fabric acoustic panels of this section. Section 00001 – Wood Paneling Section 00002 – Framing/Furring for Gypsum Board Assemblies Section 00003 – Gypsum Board Section 00004 – Mechanical Section 00005 – Electrical Section 00006 – Audio or Data DEFINITIONS A. A Frequency specific tuned acoustic absorber FRP plate to be placed over standard 6 Lb. fiberglass or mineral wool insulation board. Plate is 1/8” thick without substrate. 1.05 ALTERNATES A. Substitutions: Substitutions for products in this section may be submitted to the architect and/or acoustical consultant no later than seven (7) working days prior to the bid due date. Substitutions shall only be considered if submitted with complete information including acoustic data and a sample not smaller than 12’ x 12” showing product design and finish. Acceptance of substituted products is reliant solely on the architect’s and/or acoustical consultant’s approval and the substitution’s compliance with all specified criterion. 1.06 REFERENCES A. B. C. D. 1.07 Local Building Code – Current Edition International Building Code – Current Edition International Organization for Standardization 1. ISO 354 Measurement of Sound Absorption in a Reverberation Room American Society for Testing & Materials (ASTM) 1. ASTM C 423 - Sound Absorption & Sound Absorption Coefficients by the Reverberation Room Method 2. ASTM E 84: Standard Test Method for Surface Burning Characteristics of Building Materials DESCRIPTION A. Design Requirements: The design shall include a plate constructed of fiberglass-reinforced plastic with specified physical patterns for control of absorption over a certain frequency range. The plate may be mounted separately from the substrate or incorporated with the substrate and covered with fabric as a solid panel. Project / 2-6-2016 15152 - 1 Acoustic Wall/Ceiling Diffusers B. Performance Requirements: 1. 1.08 B. C. D. B. C. D. Freq. NRC Freq. NRC .01 .00 .03 .13 .07 .07 .22 .32 315 Hz 400 500 630 800 1000 1250 1600 .43 .61 .81 .95 1.02 1.05 1.07 .96 2000 Hz 2500 Hz 3150 4000 5000 6300 8000 10000 .87 .76 .66 .58 .53 .49 .46 .27 Product Data: Submit manufacturers’ technical data including basic system description, options and component sizes. Identify all applicable features and options. Cross out any inapplicable features or options. Shop Drawings: The contractor shall produce and submit shop drawings of products and suspension or mounting systems overlaid on base drawings (interior elevations or reflected ceiling plans) supplied electronically by the architect. Show overall layout with dimensions and references to details as necessary for penetrations, joints, ends and intersections with other materials or building components. Submit schedule of all quantities, sizes, hole patterns, edge banding, borders, veneers and finishes. Field-verify site conditions with dimensions shown on shop drawings. Samples: Minimum 12” x 12” sample of specified fabric and finish if specified. Certifications: Manufacturers’ certifications that products comply with specified requirements, including laboratory reports showing compliance with specified tests and standards. Qualifications: Manufacturer and installation contractor shall have a minimum of three years experience with similar systems. Single Source: All products under this section shall be supplied by a single manufacturer to ensure consistency in product size and finish. Woodworking Standards: Manufacturer to comply with specified provisions of Architectural Woodworking Institute quality standards. Pre-Installation Meeting: Installing contractor shall organize and conduct pre-installation meetings with all other trades to coordinate substrate conditions, conditioning of the space (temperature & humidity), and elements attaching to, penetrating through or concealed above/behind work in this section. DELIVERY, HANDLING AND SITE STORAGE A. B. C. 1.11 NRC 50 Hz 63 80 100 125 160 200 250 QUALITY ASSURANCE A. 1.10 Freq. SUBMITTALS A. 1.09 Random Incidence Sound Absorption Coefficients (a): Tested by independent testing facility according to ASTM C 423 specifications with 1/3 octave results with both NRC specifications provided. SAA Total specifications shall also be provided: Shipping and Handling: Deliver all manufacturers products to the job site in the original packaging with all components intact and inspected for any damages in shipping. Do not open until all specifications have been met. Storage: All products are to be stored in a safe, dry location with no potential for exposure to moisture, staining or excess heat or cold and allowed to acclimate to climate. Site Acceptance: Insure that all product packaging has been inspected and found free of damages, follow all criteria for storage as listed above. PROJECT CONDITIONS A. B. Project Phase Completion: All manufacturers products should be installed in the finish phase of the project, generally after all paint, dust, flooring and other trades have been substantially completed. Product Acclamation: For a minimum period of forty-eight (48) hours and prior to unpacking or installing any wood products, allow both the installation area and the wood products to stabilize in Project / 2-6-2016 15152 - 2 Acoustic Wall/Ceiling Diffusers C. 1.12 temperature and humidity levels that are representative of the final temperature and humidity levels expected after building completion and occupation. Product Handling: Handle fabric-covered panels carefully so as to avoid scratching, denting or damaging the fabric, substrate or other portions of the unit(s). WARRANTY A. The manufacturer’s warranty should be submitted to the Owner(s) or Owner(s) Representative upon delivery of the products to the site. All warranties are effective from the date of delivery to the site. The warranty for all products should be a minimum of one year and include product replacement in the event of defect, warping out of tolerances and finishes. 1.13 MAINTENANCE A. Maintenance: The manufacturer’s instructions for the cleaning and maintenance of the products shall be delivered to the Owner(s) and/or the Owner’s Representative upon delivery to the site. PART 2 PRODUCTS 2.01 MANUFACTURER A. 2.02 MATERIALS A. 2.03 2.04 1/8” thick FRP (Fiberglass-reinforced plastic) panel with multiple hole patterns specifically designed to absorb sound over a specified frequency range. Panel may come separately or mounted to a 1” 6 Lb. insulation board covered with fabric specified within this specification or indicated by architect. MANUFACTURED UNITS A. Unit Dimensions 1. Standard 4’ x 8’ Units: Height 96” Width 48” Depth 1 1/8” (with IB board) B. Weight 1. Standard 4’ x 8’ Units with IB: 35.4 pounds +/- 10 ounces MOUNTING A. 2.05 RealAcoustix LLC 887 N. McCormick Way, Layton, Utah 84041 (801) 807-0310 Email:info@RealAcoustix.com Website: http://www.RealAcoustix.com All units are mounted with impaling clips (provided) on wall surfaces with the option of construction adhesives added. Ceiling mounting requires construction adhesive and temporary holding screws or brackets. FINISHES A. Manufacturers Finishes: Architect shall choose acoustic fabrics from list provided by the manufacturer or supply his or her own suggested fabric list. PART 3 EXECUTION 3.01 INSTALLERS A. 3.02 Installing contractor shall have a minimum of three (3) years successful experience installing wood ceiling and wall systems in similar applications using similar mounting techniques or suspension systems. EXAMINATION Project / 2-6-2016 15152 - 3 Acoustic Wall/Ceiling Diffusers A. 3.03 INSTALLATION A. 3.04 The installer shall make every effort to insure a proper fit for all products while installing. In the event that adjustments shall be necessary the installer shall follow the manufacturer’s installation instructions for making these adjustments. CLEANING A. 3.06 All products shall be installed in a workmanlike fashion and by professional installers only. All products should be test fit prior to installation to insure proper fit and finish. In addition, all cavities, spaces and other locations provided by others shall be fully inspected and measured to insure that they meet the architects specifications for the installation of the manufacturer’s products. ADJUSTING A. 3.05 Site Conditions: The installer shall verify all manufacturers conditions for site conditions and insure that all conditions are optimal for installation of the products based on the information provided by the manufacturer. This shall include, but not be limited to, the substantial completion of all work that would cause dust, paint, moisture and/or other features that may be harmful to the manufacturers products. All manufacturer’s products shall be cleaned using a vacuum with a soft bristle brush only after installation. Smudges and other debris may be removed with a moist (not wet) cloth with no cleaning agents to be used in the process. Consult the manufacturer if further cleaning is necessary. PROTECTION A. All products should generally be mounted as to minimize human interaction with the products when possible. Products shall be protected from direct sunlight, excess heat (+90 degrees F) and moisture or excess humidity. END OF SECTION Project / 2-6-2016 15152 - 4 Acoustic Wall/Ceiling Diffusers