PowerLogic ION8800 energy revenue & power quality meter A PowerLogic system can help you… ● Lower operations costs ● automated, accurate billing data acquisition lowers administrative costs and eliminates errors while making the data available to regulators, service providers, and end users. ● Improve network reliability ● sophisticated power quality monitoring and reporting provide the information needed to validate compliance, improve system stability, and minimize unplanned downtime. ● Streamline business planning ● detailed information on loading, capacity, stress, and more, remove the guesswork so you can more efficiently coordinate demand-side management programs and optimize capacity planning. Schneider Electric - Division - Name – Date 2 The most advanced meter available ● The ION8800 energy and power quality meter is the newest high-end meter in the industry-leading family of PowerLogic products ● Designed for tariff metering and power quality monitoring in IEC markets ● Typically applied at interconnection points on medium, high, and ultra-high voltage networks Schneider Electric - Division - Name – Date 3 A modular design ●Retrofit compatible with IEC/DIN 43862 19” rack mount series ●Tailor the meter to the application with numerous I/O options ● Solid-state Form A and Form C digital outputs ● Mechanical alarm relay ● High and low voltage digital inputs ●3 base-model feature sets ● ION8800C - Basic tariff/energy revenue meter with sag/swell monitoring ● ION8800B – ION8800C + EN50160 compliance monitoring ● ION8800A – ION8800B + waveform capture and transient detection Schneider Electric - Division - Name – Date 4 Flexible multi-port communications ● Standard IEC1107 optical port ● Communication module options include ● 1 RS-485/RS-232 + 1 RS-485 serial ports ● Ethernet (10Base-T) or Fibre (10Base-FL) ●EtherGate: daisy-chain 31 devices to RS-485 ●Alarm notification via e-mail ●On-board web server with customizable web pages ● Modem (56 kbps) ●ModemGate: daisy-chain 31 devices to RS-485 Rear view of ION8800 meter picturing Essailec connector and communication module. ● Simultaneous communication on all ports Schneider Electric - Division - Name – Date 5 Energy and power quality metering in one ● The ION8800 meets IEC62053-22 Class 0.2S, the most stringent metering standard ● Measure power quality parameters according to IEC 61000-4-30 Class A, perform power quality compliance monitoring in accordance with EN 50160 standards, and measure flicker & interharmonics according to IEC 61000-4-15 & IEC 61000-4-7 ● Multi-user, multi-level security allows 16 designated users to gain access to the meter with security levels ranging from read access up to administrative rights Schneider Electric - Division - Name – Date 6 Meter characteristics (front panel) Graphical LCD device setup & operational screens LEDs for alarm, heartbeat, and energy Sturdy handles for easy racking Menu control & demand reset buttons IEC1107 optical ports for energy pulsing SCADA (ION, DNP 3.0, DLMS, Modbus) Anti-tamper (revenue) lock Schneider Electric - Division - Name – Date 7 Meter characteristics (rear connections) Field-upgradeable Communication module Ethernet (TCP/IP) Serial ports (RS-232 and RS-485) Modem (RJ11) port IEC/DIN 48362 Current inputs Voltage inputs and Digital I/O Schneider Electric - Division - Name – Date 8 Feature summary ION8800A ION8800B ION8800C Sag/swell monitoring g g g Symmetrical component: zero, positive, negative g g g Harmonics: individual, even, odd, total (up to 63rd) g g g Harmonics: magnitude, phase and interharmonics g g - EN50160 compliance monitoring g g - Flicker (IEC 62000-4-15) g g - Configurable for IEEE519-1992, IEEE1159-1995 g - - Transient detection g - - Waveform capture g - - Power Quality Schneider Electric - Division - Name – Date 9 Feature summary (cont.) ION8800A ION8800B ION8800C Modbus TCP master / slave (Ethernet) g/g g/g -/g Modbus RTU master / slave (serial ports) g/g g/g -/g Historical logs, maximum number of channels 800 640 32 Waveform logs, maximum number of channels 96 - - Consecutive waveform cycles captured per MB 900 - - ION8800A ION8800B ION8800C IEC 62053-22 class 0,2S compliant g g g Time-of-Use g g g Transformer/line loss compensation g g g MV-90 on serial, modem, and Ethernet ports (if present) g g g Communications & Logging/Recording Revenue Metering & Standards Schneider Electric - Division - Name – Date 10 Feature summary (cont.) Communications and I/O All models IEC1107 optical port (COM1) - standard in front of meter 1 RS-485 port (COM2) - selectable on Essailec connector or communications module 1 RS-232/485 port (COM3) - optional on communications module 1 Internal PSTN modem (COM4) - optional on communications module 1 Ethernet port - optional on communications module 1 DLMS, DNP 3.0 & Modbus RTU Slave via serial, modem & optical port g Modbus TCP through Ethernet port g EtherGate, Webmeter, ModemGate, MeterM@il features g IEC1107 Active/reactive visible LED energy optical pulse ports g Digital pulse outputs (solid state Form A) (Optional) 8 Digital pulse outputs (solid state Form C) 4 Alarm relay output (Form C) 1 Digital inputs (Optional) 3 Schneider Electric - Division - Name – Date 11 Feature summary (cont.) Setpoints, Alarming, and Control Number of setpoints Minimum response time for setpoints All models 65 ½ cycle Math, logic, trig, log, linearization formulas g Call out on single condition & multiple condition alarms g Logging and Recording All models Memory capacity (standard / optional) 5MB /10MB Maximum data points per MB (channels x depth per recorder) Timestamp resolution in seconds 165,000 0.001 Min/max logging for any parameter g GPS time synchronization (standard on serial; optional on IRIG-B) g Power line time synchronization g Schneider Electric - Division - Name – Date 12 Application: network revenue metering ● Metering at generation, transmission, or distribution locations requires: ● Highest standards of accuracy ● Multiple communications ports ● Multiple protocols ● Security ● Compensation algorithms ● Billing system compatibility ● Power quality monitoring ● Web capabilities Schneider Electric - Division - Name – Date 13 Application: network revenue metering ● The ION8800 meets and exceeds network revenue metering requirements: ● IEC 62053-22 class 0,2S accuracy ● Ethernet, modem, and serial communications ● ION, Modbus and DLMS protocols ● Multi-user, multi-level security as well as anti-tamper seals on the meter ● Instrument transformer correction and Transformer/line loss calculation capabilities ● MV-90 compatibility on serial, modem, and Ethernet communications Schneider Electric - Division - Name – Date 14 Application: power quality monitoring ● EN50160 compliance reporting ● Analyze/troubleshoot based on IEC 61000-4-30 Class A ● Flicker to IEC 61000-4-15; harmonics/interharmonics to CEI 61000-4-7 ● Digital fault recording at 1024 samples/cycle ● 17/20µs (60/50Hz) transient detection and capture Schneider Electric - Division - Name – Date 15 Application: engineering and operations ● The ION8800 integrates with SCADA software and supports substation automation: ● Feeder monitor aggregation and other PLC/RTU features within the substation ● Ethernet, modem, and serial communications ● ION, DNP 3.0, Modbus RTU master/slave, and Modbus TCP master/slave protocols ● WebMeter (onboard web server) and Meterm@il Schneider Electric - Division - Name – Date 16 The PowerLogic family ● Schneider Electric is the world’s largest provider of energy efficiency, power quality and reliability solutions ● PowerLogic offers enhanced, compatible and expanding breadth of capabilities and support ● Customers can leverage existing PowerLogic and ION investments and buy new PowerLogic products with confidence ● Compatible and expanding breadth of capabilities and support Schneider Electric - Division - Name – Date 17 For more information, visit powerlogic.com Schneider Electric - Division - Name – Date 18