® ION8600
Add application photo in this area
SM
Overview
●Monitor network interties, service entrances and substations
●Ideal for independent power producers and co-generation applications
● Accurately measures energy bi-directionally, in both generation and standby modes
●Gives utilities the tools to manage complex energy supply contracts
● Includes commitments to power quality
●Integrate with energy management and SCADA systems
Copyright © Schneider Electric 2008. All rights reserved.
2
Revenue metering
●ION8600 meters meet stringent IEC and ANSI revenue metering standards on true RMS voltage, current, and power
● ANSI C12.20 0.2, Class 2, 10, & 20
● IEC 62053-22 Class 0.2S
●The meters perform power quality and compliance monitoring in accordance with CBEMA/ITIC, IEEE 519 – 1992, and IEEE 1159 and monitor flicker to IEC 61000-4-15, and harmonics to IEC 61000-4-7
●Multi-user, multi-level security protects the ION8600 meter, allowing you to control and customize access for up to 16 users
Copyright © Schneider Electric 2008. All rights reserved.
3
Modularity and communications
●ION8600 meters use patented ION® technology, giving meters a modular, flexible architecture that allows for extensive user programmability
●Meters address complex monitoring and control applications, and avoid obsolescence by adapting to changing needs
●The ION8600 offers complete communications: fiber, Ethernet, serial, and modem
● Gateway functionality simplifies communications architecture and reduces leased line or connection costs
● Ports communicate with a variety of protocols (ION, DNP 3.0, Modbus RTU,
Modbus TCP, MV-90)
● Meters have the capability to dial out when memory is near full, and to push data through SMTP (email)
Copyright © Schneider Electric 2008. All rights reserved.
4
Front panel characteristics
Backlit LCD Display
Master Reset Pinhole
(located under front label)
Demand Reset Switch
Test Mode Button
(located under front label)
Navigation Buttons
Alt/Enter Button
Copyright © Schneider Electric 2008. All rights reserved.
5
Features
Feature
Metering
Power, energy and demand
Power quality
Sag/swell, harmonics monitoring
Harmonics: individual, even, odd, up to
Harmonics: magnitude, phase, & interharmonics
Symmetrical components: zero, positive, negative
Transient detection, microseconds (68 µs for
60 Hz, 78 µs for 50 Hz)
Sampling rate, maximum samples per cycle
Uptime in number of nines
Logging and recording
Memory standard/optional
Min/max logging for any parameter
Timestamp resolution in seconds
Copyright © Schneider Electric 2008. All rights reserved.
ION8600
A
ION8600
B
ION8600
C
■
■
63 rd
40 th
■
65/78
256
■
10 MB
■
0.001
■
■
63 rd
■
256
■
4 MB
■
0.001
■
■
31 st
■
256
■
2 MB
■
0.001
6
Features
Feature
GPS time synchronization
Communications and I/O
RS-232/485; RS-485; Ethernet; Optical; IRIG-B
Internal modem
3-port DNP 3.0 via serial, modem, Ethernet, I/R ports
Modbus RTU slave/master; Modbus TCP via Ethernet
EtherGate, ModemGate, MeterM@il, WebMeter
Internal KYZ outputs/Form A inputs
Ext. digital status inputs/counter/solid state outputs
Setpoints, alarming, and control
Setpoints, number/minimum response time
Math, logic, trig, log, linearization formulas
Call-out on single- and multi-condition alarms
Revenue metering
MV-90 on serial, modem, & Ethernet ports, (if present)
Multi-year scheduling: hourly activity profiles
Transformer/line loss compensation; ITC
Copyright © Schneider Electric 2008. All rights reserved.
ION8600A ION8600B ION8600C
■ ■ ■
■
1
■
■
■
4/3
8/8
■
1
■
■
■
4/3
8/8
65/ ½ cycle 65/ ½ cycle 65/ 1 sec
■ ■ ■
■ ■ ■
■
■
■
■
■
■
■
■
■
■
1
■
■
■
4/3
8/8
7
Applications
Use the ION8600 to:
●Perform revenue metering
●Monitor both co-generation and IPP
●Perform energy pulsing and totalization
●Monitor compliance with international standards
●Analyze power quality
●Control demand and power factor
●Performing load curtailment
●Monitor and control your equipment
●Correct instrument transformers
Copyright © Schneider Electric 2008. All rights reserved.
8
Applications
●Revenue metering
● Revenue approved, bi-directional measurements; monitors four quadrants
● Monitor compliance with energy supply contracts
● Energy suppliers: offer customized rates, flexible billing, transformer/line loss compensation, and web-based reporting
● Energy consumers: audit power requirements and confirm bills
● Highest revenue metering accuracy
● Advanced security for 16 different users – individual passwords and rights
Copyright © Schneider Electric 2008. All rights reserved.
9
Applications
●Co-generation and IPP monitoring
● Monitors bi-directional flow for both generation and stand-by modes
●Energy pulsing and totalization
● Use digital I/O for KYZ pulsing, end-of-interval and totalization
●Compliance monitoring
● Monitor compliance with international flicker and harmonics standards, IEC
61000-4-7/ 4-15
Copyright © Schneider Electric 2008. All rights reserved.
10
Applications
●Power quality analysis
●Detects, records, and communicates information – nature and sequence of power quality events
●Identify the cause of transients, harmonics, sags and swells
●Measure percentage of system uptime in nines
●Waveform recording and compliance monitoring
● Monitor compliance with international flicker and harmonics standards
●Diagnose and benchmark power quality on the grid and at key customer locations – allows utility personnel to make informed decisions
●Analyze problems and avoid repeat interruptions
Copyright © Schneider Electric 2008. All rights reserved.
11
Applications
●Demand and power factor control
● Avoid penalties – load shedding, scheduling, peak shaving and capacitor bank control
● Standard demand calculation methods: block, rolling block, thermal, predicted
● Measure on any instantaneous value and record peak and minimum
Copyright © Schneider Electric 2008. All rights reserved.
12
Applications
●Load curtailment
● 800 user configurable channels via 50 data recorders (feature set A)
● Record energy, demand, voltage, current, power quality, etc.
● Implement load curtailment and distributed generation strategies
● Modbus Master enables detailed facility monitoring
●Identify inefficiencies; develop strategic load shedding applications
●Use like an RTU to intelligently poll downstream devices such as relays or other metering products
Copyright © Schneider Electric 2008. All rights reserved.
13
Applications
●Equipment monitoring and control
● Record details of equipment status
● Use information from several meters to correlate system-wide events and equipment operation
● Base maintenance schedules on operating history
● Meter all your utilities including gas, steam, water and more
Copyright © Schneider Electric 2008. All rights reserved.
14
Applications
●Instrument transformer correction
●Compensate for line loss, and power and instrument transformers
●Save money and improve accuracy
● Install on the low side of your transformers to compensate for less accurate equipment
Copyright © Schneider Electric 2008. All rights reserved.
15
More Information
●Visit us on the web at:
●www.powerlogic.com
Copyright © Schneider Electric 2008. All rights reserved.
16