Computed Tomography CT, CAT tomos = slice, graphein = to write Magdalena Bazalova 1. What is a CT scanner? • an X-ray device capable of cross-sectional imaging • creates images of slices through the patient What is a CT scanner? • doughnut shaped gantry with moving patient table Why CT? • conventional radiography suffers from collapsing of 3D structures onto a 2D image • although the resolution of CT is lower, it has extremely good low contrast resolution enabling the detection of very small changes in tissue type • CT gives accurate diagnostic information about the distribution of structures inside the body CT scanning applications • very wide ranging – good for imaging bone and soft tissue – diagnostic imaging – radiotherapy planning • 3D applications CT imaging applications CT imaging applications CT imaging applications Why CT for radiotherapy? • Radiation therapy planning is done on the basis of patient CT images and is therefore patient specific – the target and organs at risk are delineated in CT images (possibly with help of other imaging modalities – PET) – dose calculation algorithms use CT images for determination of dose delivered to the patient during treatment Why CT for radiotherapy? • Tissue inhomogeneities can be taken into account in most treatment planning systems • Dose to soft tissue is different than dose to cortical bone - mass density variations between tissue types are the most important factor • Therefore, mass densities of tissues have to be known for an accurate dose calculation • CT images do not represent mass densities of patient body directly but they can be converted into mass densities using a calibration curve 2. CT scanner components X-ray tube X-ray beam detector ring X-ray journey X-ray tube Beam shaping filter Detectors Detector arrangement Philips CT simulator Questions on CT apparatus • How do we call the device that produces X-ray beam? – (X-ray tube ) • What have the X-rays pass through on their way to the detector ring? – (beryllium window, Al filters, bow-tie filter, patient, anti-scatter grid) 3. CT image definition and formation What are we measuring in CT? • the linear attenuation coefficient, µ, between the X-ray tube and the detector • the linear attenuation coefficient is a measure of how rapidly are X-ray attenuated I I 0 exp(x) 2D-projection data set - sinogram I • projections p ln I0 -d x-ray source -d • I, I0 - intensities d p d Projection angle Reconstruction algorithms • • • • Computer based simple back-projection filtered back-projection iterative techniques Simple back-projection • reverse the process of measurement of projection data to reconstruct an image • each projection is uniformly distributed across the reconstructed image Simple back-projection 1/r blurring Filtered back-projection • simple back-projection produces blurred images • projection data need to be filtered before reconstruction • different filters can be applied for different diagnostic purposes – smoother filters for viewing soft tissue – sharp filters for high resolution images • back-projection is the same as before Filtered back-projection Image reconstruction Simple back-projection Filtered back-projection FBP Patient image reconstruction Patient filtered back-projection CT number scale HU represents the linear attenuation of a material. CT number window CT number window CT for radiotherapy – calibration, HU to mass density conversion • HU do not represent mass density, needed for dose calculation, directly. To obtain mass densities of each voxel: • A set of tissue equivalent materials with known mass densities is scanned and a calibration curve is created Calibration curve for treatment planning Mass density calibration curve 1.800 3 mass density [g/cm ] 1.600 y = 5.78E-04x + 1.05E+00 1.400 1.200 1.000 y = 8.84E-04x + 9.83E-01 0.800 0.600 y = 1.03E-03x + 1.03E+00 0.400 0.200 0.000 -1000 -500 0 500 HU 1000 Questions on reconstruction • How do we call picture and volume elements? – (pixels and voxels) • What do CT images represent? – (linear attenuation coefficients of voxels) • How do we call raw detector data? – (a sinogram) • Name two reconstruction techniques? – (simple and filtered back-projection) 4. CT technology Third generation CT scanners Fourth generation CT scanners Fifth generation CT scanners Helical CT scanning Advantages of helical mode Questions on CT technology • How many CT generations exist? – 5 (maybe more) • Which one is the third one? – rotate/rotate • What are the advantages of helical scanning? – arbitrary image position, faster scanning 5. CT image quality Image noise Image noise Image contrast Image contrast Factors affecting image noise Reconstruction filters Factors affecting detector signal Radiation dose Questions on image quality • Name three factors that influence image quality. – kVp, mA, time, filteration of the beam, slice thickness, reconstruction filter, pitch • Name three parameters that describe image quality – spatial resolution, contrast, noise • What is noise? – variation in HU in a uniform image • What is contrast – ability to resolve details without blurring 6. Artefacts in CT If not recognized, CT artifacts can cause misdiagnosis and incorrect outcomes of radiotherapy treatment planning. Definition of CT artefacts Types of CT artefacts Origin of artefacts Beam hardening: cupping Beam hardening: correction Beam hardening: correction Reduction of streaks and bands Partial volume artefacts Partial volume artefacts Minimizing partial volume artefacts Photon starvation Avoidance using mA modulation Metal artefacts Metal artefact reduction Patient motion artefacts • Voluntary and involuntary motion cause artefacts in the reconstructed image Minimizing motion artefacts Motion artefact correction Detector sensitivity: ring artefacts Ring artefacts CT artefacts: summary Questions on CT artifacts • Remedy for photon starvation? – mA modulation, adaptive filtering • What can cause metal artifacts in patients? – dental implants, surgical clips, electrodes, prostheses • In which CT generation can occur ring artifacts? – in the 3rd where detector ring rotates with X-ray tube