EcoPart 400 6 – 34 kW Design & dimensions • Front panel – 2 screws • Pre-cut holes for flexible tubes • Adjustable feet Design & dimensions Brine connection • 4 flexible tubes included mounted from factory • All direction compliant Water IN Water OUT Brine Sole IN insulated Brine Sole OUT insulated Brine connection • Insulated • Tested with water in factory • Inside the product Power output • In the same dimension CTC EcoPart 406 CTC EcoPart 408 CTC EcoPart 410 CTC EcoPart 412 CTC EcoPart 414 CTC EcoPart 417 5,90 kW 8,19 kW 9,98 kW 11,75 kW 14,29 kW 16,87 kW COP – Noise level • COP 0/35 EN14511 CTC EcoPart 406 CTC EcoPart 408 CTC EcoPart 410 CTC EcoPart 412 CTC EcoPart 414 CTC EcoPart 417 4,57 4,58 4,60 4,60 4,55 4,62 • Sound Power *EcoHeat ”old” 300 • Mätningar enligt EN3747 vid 0/35. Värden gäller både 400V och 230V. CTC EcoPart 406 CTC EcoPart 408 CTC EcoPart 410 CTC EcoPart 412 CTC EcoPart 414 CTC EcoPart 417 43 dB (A)* 42,5 dB (A)* 48,5 dB (A)* 49,2 dB (A) 51,5 dB (A) 51,2 dB (A) Noise level • Compressor cover • New quality insulation Other options • Filling kit for sole / brine • Charging pump – accesory • StratosTec 25/6 • StratosTec 25/7 • 25/8,5 Electrical box • Soft starter card • Control system for HP • Accessible from front • Also EcoHeat 300 Electrical installation • Cabling • SEPARATE Bus and Supply Control system • Various options • BasicDisplay • EcoLogic V3 CTC Interface • EcoEl V3 • EcoZenith i550 • Ecologic PRO Basic Display Control system • Basic Display for fixed temperature – Short parameter list • Return temperature setpoint • Differential on / off • Reading of the temeratrure • Reading of the pressur • Set the heatpump number for cascade – Alarm handling – Needed for casade application Display Name Description Ecoair, Ecopart 101 Operation mode If mode is Fix return stop, display shows set-value for stop temperature, other modes are displayed with corresponding letter A1, A2, A3 … A10 EA + EP 102 Start stop difference Only in Fix Return Stop Mode. Other modes do not show this display. EA + EP in fixed return stop mode 103 Discharge Measured discharge temperature is shown here. EA + EP 104 Outdoor Temperature Measured outdoor temperature is shown here. EA 105 Last error / present error Displays the last / preset alarm with the letter “E” followed by the corresponding error code EA + EP 106 Brine out temp Measured Brine Out temperature or Exhaust air temperature is shown here. EA + EP 107 Brine in temp Measured Brine In temperature is shown here. EP 108 Inlet temp Measured Inlet temperature is shown here. EA + EP 109 Outlet temp Measured Outlet temperature is shown here. EA + EP 110 Suction temp Measured Suction temperature is shown here. EA + EP 111 High Pressure Measured Pressure in bar in high pressure side is shown here. EA + EP Special function: If up + dn is pressed for 3 seconds in this menu and product = EA -> start a defrost. The defrost should then run and stop according to its function description. 112 Low Pressure Measured Pressure in bar in low pressure side is shown here. EA + EP 113 Evaporation C Measured Evaporator temperature from low pressure conversion is shown here EA + EP 114 Condensing C Measured Condensing temperature from high pressure conversion is shown here EA + EP 115 Suction SH Superheat is shown here EA + EP 116 EV % Expansion valve opening is shown here EA + EP 117 Capacity KW Capacity from heat counter function is shown here. EA + EP 118 Current A Current (from soft starter) is shown here EA + EP 119 Defrost Timer Timer defrost is shown here EA Control system, Converter • Ecologic V3 & EcoEl V3 + CTC Converter • Cable connection between EcoPart and Converter • Wall mounted • Use of the 12 systems in EcoLogic CTC Converter Converter Control system, Converter Control system • Next step – CTC EcoLogic PRO • Use of 6 systems • See Ecologic presentation Next step • EcoPart XL • EcoPart 424 • EcoPart 434 EcoPart XL • Performance