Cast iron Drainage 1st Choice Sound attenuation Acoustic definitions Acoustic definitions Acoustic definitions Airborne through the wall Sounds : Structure-borne coming from the seal Airborne Airborne + Structure-borne Structure-borne coming from supports European regulations Requirements on wastewater installations • On structure-borne noises (equipment behind the room) Germany, France,… Main rooms (living, bedroom,…) Other rooms (Kitchen, office…) < 30 dB(A) < 35 dB(A) Conclusion European test method formulated by CEN TC 126 • New standard EN 14366: 2004 •Acoustic property of products for construction used in buildings. « Laboratory measurements of noise from wastewater installations » DN 70 to 150 Inlet Support device Wall : 250+50 kg/m² No sealing CEN TC 126 is a working group representing a cross section of materials (CI, Plastic, etc.) Test Results Application in Germany IBP laboratory – Stuttgart (Independent Test) Tested Ensign Cast Iron to the New standard EN 14366 : 2004 Structure-borne noises : DN 100 - 220 kg/m² wall - 4 l/s Bracket Type Rubber lined Bracket RB422 Ductile Iron bracket fitted with separate EG Room Living room 25dB UG Room Basement 29dB EG UG 11dB 11dB Conclusion Airborne noise Cast iron Cast iron Cast iron Cast iron >6-9dB(A) quieter than Twin-wall PVC >10dB(A) quieter than HDPE silent >13dB(A) quieter than stainless steel >14dB(A) quieter than PVC-U Airborne and structure-borne noise Cast iron system using RB422 bracket meets the most stringent requirement of BS8233 Cast iron system using new separate fitted to ductile bracket EF048 = >6-9dB(A) superior to best plastic material Tests and Results completed: Independent testing facility To the new appropriate standard Test results certified. ALL MATERIALS SHOULD TEST TO BS EN 14366 European regulations