93PM: Value, Benefits, and Features Where aesthetics meet intelligence © 2013 Eaton Corporation. All rights reserved. Eaton 93PM 100 kW UPS Overview The perfect three-phase white or gray space solution for today’s datacenter Industry leading: • • • • Efficiency (97%-99%) Footprint (35% < closest competitor, standard rack size) Flexibility (thermal management options, service from front) Manageability (touchscreen, modular design, remote man.) Communication Cards 50 kW Power Module Product Snapshot Power Rating: 60, 70, 80, 90, 100 kW Power Factor: Unity PF 1.0 Topology: Double-Conversion with ESS Mode Efficiency: 97% - 99% Input / Output Voltage: 480V Input THD: < 3% Configuration: Tower Options: line and match EBC, IAC-D, MBS… 50 kW Power Module Static Switch I/O connections 93PM is the next gen. 9390 (400/480V) with exciting new features for 2013 © 2013 Eaton Corporation. All rights reserved. 93PM value proposition The Eaton 93PM UPS combines unprecedented efficiency, reliability and vertical or horizontal scalability with eye-catching design. A space-saving, flexible device that’s as easy to deploy as it is to manage, it’s the perfect three-phase white or grey space solution for today’s data center. © 2013 Eaton Corporation. All rights reserved. 3 Top 93PM benefits 1. Lowest TCO • Reduces power and cooling OPEX through industry-leading energy efficiency • Lowers CAPEX through internal modular scalability and internal redundancy • Conserves valuable data center floor space with its compact footprint 2. Ease of deployment • Maximizes deployment flexibility by providing innovative thermal management options, flexible configurability and full service access from the front • Simplifies installation by fitting perfectly in line or alongside any standard-depth rack 3. Ease of management • Provides easier access to detailed status information through its large, user-friendly LCD touchscreen interface • Optimizes server virtualization solutions through its full suite of power management and connectivity software • Increases uptime through its 24x7 remote monitoring and reporting capabilities © 2013 Eaton Corporation. All rights reserved. 4 Top 93PM benefits Lowest TCO Up to 99.1% efficient in ESS mode. Up to 97% efficient in double conversion mode. (Provides the highest energy cost savings across the entire operating load range) Internal modular scalability allows the customer to pay as they grow (available at full launch) Internal redundancy reduces the need for additional UPS’s (available at full launch) Space-saving designed UPS and ‘line and match’ accessory suite Ease of deployment Space-saving, standard rack depth form factor Multiple thermal management options Flexible configuration and pass-through wiring can be placed at either end of a row or against the wall Flexible run time options Top or bottom cable entry Ease of management Intuitive, touch-based color LCD interface Green/yellow/red LED light-bars that make system status visible from a distance Complete front serviceability Full suite of connectivity and software management solutions 24/7 E-notify remote monitoring © 2013 Eaton Corporation. All rights reserved. 5 Lowest TCO: Energy efficient Reduces power and cooling OPEX through industry-leading energy efficiency • Up to 99.1% efficient in ESS mode. • Up to 97% efficient in double conversion The 93PM provides the highest efficiency across the entire operating load range! © 2013 Eaton Corporation. All rights reserved. 6 ESS: How is it different than “Eco” mode Fastest Transfer Times: • ESS offers < 2ms transition times for an outage condition (vs. up to 12ms for Eco Mode). Inherent Surge Protection: • Transformer-less ESS topology offers non-degenerative filtering for lightning strikes. Load Fault Detection and Clearing: • ESS determines if the fault is at the source or load. For load faults, the UPS will maximize it’s fault clearing current by not only turning the inverter on but also leaving the source engaged with the critical load (providing the maximum fault clearing current). © 2013 Eaton Corporation. All rights reserved. 7 93PM energy savings Summary: • ESS provides the ultimate in energy savings (ideal for data center environments and more)! • For those applications requiring double conversion, the 93PM provides the highest energy cost savings as well! • Both modes of operation provide the highest energy cost savings across the entire operating load range. © 2013 Eaton Corporation. All rights reserved. 8 Lowest TCO: Scalable and redundant (available with full 200kW launch in Q3) Grow Vertical Ideal for co-lo’s, fast growing .com’s and businesses! Lowers CAPEX through internal modular scalability and internal redundancy in future versions: • Scales up in modular 50 kW increments, so there’s no need to buy excess capacity in advance • Delivers long-term value because it grows as your business does • Features built-in modular redundancy, hence there’s no need for a second unit to keep uptime high © 2013 Eaton Corporation. All rights reserved. 9 Lowest TCO: Footprint $700 annual footprint savings (*using $150 sq-ft annual cost) Conserves data center floor space • Save up to $700 annually in footprint savings (against leading competitor “L”). • Slim line accessories (slim detachable MBS provides a “true” low cost solution). • Full launch space savings benefits: • Built-in redundancy/scalability reduces needs for redundant UPS’s (saving cost and space). • Internal batteries up to 50kW provides the ultimate footprint solution. Fits through standard doors and in elevators, so no need for cranes or dismantling © 2013 Eaton Corporation. All rights reserved. 10 Ease of deployment: Configurability Maximizes deployment flexibility by providing flexible configurability Standard-depth form factor • Fits in-line or alongside any standard server rack • Fits against the wall, too Top or bottom cable entry • Supports both raised floors and overhead power distribution Mix-and-match accessories • Deploys in multiple configurations on either side of UPS without affecting pass-through wiring • Supports end-of-row applications (ideal for mirrored A/B end of row applications) Sleek design looks great in either white or grey space © 2013 Eaton Corporation. All rights reserved. 11 Ease of deployment: Flexible thermal management Optional front to rear air flow is ideal for hot/cold aisle configurations. Slim chimney 93PM connections allows for overhead busway and cable trays. Maximizes deployment flexibility by providing innovative thermal management options. © 2013 Eaton Corporation. All rights reserved. 12 Ease of management: LED status bars • The green/yellow/red LED light-bars make system status visible from a distance in data centers. Green LED’s -> System online and normal. Yellow LED’s -> System on battery or bypass. Red LED’s -> Service required. © 2013 Eaton Corporation. All rights reserved. 13 Ease of management: LCD touchscreen display A color touchscreen display that will make your kids proud! © 2013 Eaton Corporation. All rights reserved. 14 Ease of management: Connectivity options Power Xpert Gateway Mini-slot card: • Designed specifically to connect the Eaton 93PM UPS to Ethernet networks • Embedded web server • 1G flash memory and 128 MB RAM • Multiple log files stored directly in the card’s memory • Multi-module support • Multiple protocol support including SNMP, BACnet IP, Modbus TCP, Modbus RTU Note – up to two cards can be used for independent/redundant networks. Industrial Relay Mini-slot card: • 5 relays • Connections: • 250 V • 3–5A • Isolated • Terminal block connection © 2013 Eaton Corporation. All rights reserved. 15 Ease of management: Comprehensive software suite Eaton’s intelligent power manager software enables you to: • Remotely monitor and manage multiple devices across your network from a single interface; this can be integrated into an already existing platform, such as VMware, Microsoft or Citrix • Measure power consumption and kWh to calculate power usage effectiveness • Trigger load shedding of lesser priority server workloads to extend battery run time in a virtualized environment. • Trigger workload transfer to disaster recovery site with no loss of data, using VMware’s Site Recovery Manager. Eaton’s intelligent power protector software enables you to: • Reboot hung-up machines through watchdog functionality • Avoid data loss by automating graceful shutdown of machines during extended power outage • Maximize uptime with redundancy capabilities for dual-cord servers • www.eaton.com/intelligentpower © 2013 Eaton Corporation. All rights reserved. 16 Eaton 93PM 100 kW Taking a closer look–the UPS functional core * Top cable entry requires sidecar option. © 2013 Eaton Corporation. All rights reserved. 17 Eaton 93PM UPS 100 kW accessories 93PM Battery Runtime Chart (E50) - Minutes Load kW 1 IBC-L 2 IBC-L 3IBC-L 20 129.2 289.4 463.9 30 80.8 181.1 290.2 40 58.2 130.2 208.7 50 45.1 101.0 161.9 60 36.7 82.1 131.6 70 30.7 68.8 110.3 80 23.1 58.9 94.5 90 19.9 51.4 82.4 100 17.2 45.5 72.9 • Empty or MBS side car required for top cable entry. • Interconnect cables included • Side car required for remote top cable entry. • Line and match interconnect cables included • 4 IBC-L Interconnect cables are not provided. 405.5 291.7 226.3 183.9 154.1 132.0 115.1 101.8 E39 available providing 11min at 100kW © 2013 Eaton Corporation. All rights reserved. 18 Eaton 93PM UPS 100 kW: Technical specification 100% Real Power (1.0 PF) Lowers customers THD with <3% iTHD (market lead) 0.8 leading to 0.8 lagging without derating © 2013 Eaton Corporation. All rights reserved. 19 93PM: Unlock real power Why Unity: • Modern data centers loads are approaching unity power factor. • “Since the data center power factor is high and, as such, kW is very close to kVA, some people discount the difference and use the two interchangeably. This is very dangerous and can lead to the creation of “phantom” capacity. “ – datacenterguru.blogspot.com • The 93PM addresses this by providing 100% real power. © 2013 Eaton Corporation. All rights reserved. 20 93PM Summary Why the 93PM will win! • Highest efficiency UPS in the market! • The most flexible installation and thermal management solutions • Smallest footprint • Unity power factor is ideal for today’s loads • Lowest input current THD in the industry • Future scalability and internal redundancy (with launch of 200kW offering) “Breakthrough innovations rarely occur within a technical discipline, or within a market, but almost always where you create a novel intersection.” - Clay Christensen …..the 93PM provides the combination of breakthrough innovations that will capture the attention of today’s markets! © 2013 Eaton Corporation. All rights reserved. 21 Eaton 93PM UPS 100 kW accessories • MBS (Maintenance Bypass Slim ) Line and match and allows UPS removal • IACD (Integrated Accessory Cabinet-Distribution) (with optional 42 pole panels and subfeed breakers). • EBC (Line and match external battery cabinet) • Wall mount maintenance bypass © 2013 Eaton Corporation. All rights reserved. 22 Customer Drawings •UPS and Battery Cabinet © 2013 Eaton Corporation. All rights reserved. 23 Basic UPS Dimensions © 2013 Eaton Corporation. All rights reserved. 24 UPS Sidecar mounts either side © 2013 Eaton Corporation. All rights reserved. 25 UPS with sidecar-detail © 2013 Eaton Corporation. All rights reserved. 26 Top/Bottom layout with Sidecar © 2013 Eaton Corporation. All rights reserved. 27 Service Clearances and Environmental © 2013 Eaton Corporation. All rights reserved. 28 Termination locations © 2013 Eaton Corporation. All rights reserved. 29 One-Line © 2013 Eaton Corporation. All rights reserved. 30 Screen shots © 2013 Eaton Corporation. All rights reserved. 31 Meters Screen © 2013 Eaton Corporation. All rights reserved. 32 Input Specs © 2013 Eaton Corporation. All rights reserved. 33 Output Specs © 2013 Eaton Corporation. All rights reserved. 34 Environmental specs © 2013 Eaton Corporation. All rights reserved. 35 UPS/Sidecar CTO UPS Product Family Line 1 2 9 P 93PM System2 Rating Model1 Voltage3 Efficiency Internal Batteries4 Input Options5 Configuration Options 3 4 5 6 7 8 9 A 50 kW Capacity Frame 0 2 20 kW A 400 V, 4 wire 0 No Internal Batteries 0 Single Feed, no Internal MBS 0 No ESS, no VMMS B 50 kW Redundant Frame, 1 UPM 0 3 30 kW B 400 V, 3 wire 1 With Internal Batteries (3 strings), type 7Ah LL 1 Single Feed, with Internal MBS 1 No ESS, with VMMS C 50 kW Redundant Frame, 2 UPM 0 4 40 kW C 480 V, 4 wire 2 With Internal Batteries (3 strings), type 9Ah 2 Dual Feed, no Internal MBS 2 With ESS, no VMMS D 100 kW Capacity Frame, 1 UPM 0 5 50 kW D 480 V, 3 wire 3 With Internal Batteries (4 strings), type 7Ah LL 3 Dual Feed, with Internal MBS 3 With ESS, with VMMS E 100 kW Capacity Frame, 2 UPM 0 6 60 kW E 380 V, 4 wire 4 With Internal Batteries (4 strings), type 9Ah F 100 kW Redundant Frame, 1 UPM 0 7 70 kW F 380 V, 3 wire 5 With Internal Batteries (5 strings), type 7Ah LL G 100 kW Redundant Frame, 2 UPM 0 8 80 kW G 360 V, 4 wire 6 With Internal Batteries (5 strings), type 9Ah H 100 kW Redundant Frame 3 UPM 0 9 90 kW H 360 V, 3 wire 7 With Internal Batteries (6 strings), type 7Ah LL J 150 kW Capacity Frame 1 UPM 1 0 100 kW J 415 V, 4 wire 8 With Internal Batteries (6 strings), type 9Ah © 2013 Eaton Corporation. All rights reserved. 36 UPS/Sidecar CTO Sidecar / Top Entry6 Connectivity Slots 10 11 Sidecar7 Breaker kAIC Rating 12 Cabinet8 Factory Configuration Location 13 14 0 None (Empty) A No Sidecar 0 no specification 0 With Dress Skins, Top Air Exhaust H HPO 1 Network and EMP B No Breakers, Left Mount 1 STD kAIC, all Breakers Aux 1 With Dress Skins, Rear Air Exhaust R RPO 2 MODBUS and EMP C No Breakers, Right Mount 2 STD kAIC, MBS Aux Only 2 No Dress Skins, Top Air Exhaust B BA1 3 Relay, Network and EMP D 2 Breaker, Left Mount (MBS) 3 High kAIC, all Breakers Aux 3 No Dress Skins, Rear Air Exhaust 4 Relay E 3 Breaker, Left Mount (MBS) 4 High kAIC, MBS Aux Only 5 PXGMS F 4 Breaker, Left Mount (MBS) 6 Network G 2 Breaker, Right Mount (MBS) Generation Code 15 0 Generation 1 H 3 Breaker, Right Mount (MBS) J 4 Breaker, Right Mount (MBS) © 2013 Eaton Corporation. All rights reserved. 37 Battery Cabinet IBC-L—432 VDC-36 batts © 2013 Eaton Corporation. All rights reserved. 38 Battery Cabinet CTO System 1 2 9 P Version 3 93PM Z Accessory 4 Accessories Associated UPS Model 5 DC Voltage 6 A 432V Battery Type Remote / Top Entry Side Car 7 8 9 10 E 3 9 PWR 12-390 0 Line and Match, with no side car E 5 0 PWR 12-500 1 Remote Installation, no side car A EBC A 50 KW B SEBC B 100 KW C Seismic EBC C 150 KW L Remote, with Left side car for top entry D 200 KW R Remote, with Right side car for top entry © 2013 Eaton Corporation. All rights reserved. 39 Battery Cabinet Wiring © 2013 Eaton Corporation. All rights reserved. 40 Battery Wiring Standalone vs Matching © 2013 Eaton Corporation. All rights reserved. 41 IAC-D Cabinet © 2013 Eaton Corporation. All rights reserved. 42 IAC-D CTO 1 9 System 2 P 93PM Version 3 Z Accessories Accessory 4 D 50 KVA IAC-D 5 1 K1, Non TP1,480/208 Delta/WYE 6 S E 100 KVA IAC-D 2 K13,Non TP1 480/208 Delta/WYE H High KAIC F 150 KVA IAC-D 3 G 200 KVA IAC-D 4 Distribution Breaker Type 9 0 Transformer Distribution Top No Distribution No Distribution B 225A Panel Board Top B 225A Panel Board Bottom K1,TP1,480/208 Delta/WYE 1 1 Subfeed Breaker 1 1 Subfeed Breaker K13,TP1 480/208 Delta/WYE 2 2 Subfeed Breaker 2 2 Subfeed Breaker 3 3 Subfeed Breaker 3 3 Subfeed Breaker 4 4 Subfeed Breaker C 400A Panel Board Bottom 5 5 Subfeed Breaker Branch Metering 0 Cabinet Configuration 11 None 0 STD KAIC 7 0 Distribution Bottom 8 0 10 80% Rated Breaker KAIC Rating Optional Breaker 12 Standard Configuration 0 No Optional Breaker 1 1 Optional 225A Breaker Open Open Generation Code 13 14 15 0 0 0 Generation 1 w Top Exhaust 1 80% Rated Breaker w Aux(Distribution Subfeed only) 1 Standard Configuration w Rear Exhaust 2 100% Rated Breaker(Distribution Subfeed Only) 2 Seismic Configuration w Top Exhaust 3 100% Rated Breaker w Aux(Distribution Subfeed only) 3 Seismic Configuration w Rear Exhaust © 2013 Eaton Corporation. All rights reserved. 43 Tomorrow’s battle card and roadmap session? We will: • Review the 93PM’s top three competitors • 2013 93PM launch roadmap (slim battery cabinet, full kW launch, additional features,…) • 93PM price book review • 9390 EOL plans • What’s next after the 93PM launch? © 2013 Eaton Corporation. All rights reserved. 44 Questions © 2013 Eaton Corporation. All rights reserved. 45