Heat exchanging mode - MODERN REFRIGERATION UK LTD

advertisement
Heat Recovery Ventilator
Be used with AC system,
Create a healthy life.
Content
 Product lineup
 Futures
 Structure & Dimensions
 Fan performance
 Specifications
Product line-up
Model
Air flow(m3/h) Power Supply
Model
Air flow(m3/h) Power Supply
HRV-200
200
HRV-1500
1500
HRV-300
300
HRV-2000
2000
HRV-400
400
HRV-500
500
HRV-800
800
HRV-1000
1000
220~240V,
50Hz,1Ph
380V,50Hz,3Ph
Futures

Energy saving
Fresh-air and exhaust air cross the heat exchanger. Temperature exchanging
happens. Fresh-air can get a great deal of energy from exhaust air.

High efficiency.
Thanks to the high quality paper-core heat-exchanger.
1.Good moisture permeability and air tightness
Energy exchanging efficiency up to 74%
2. Good anti-combustibility
More safety and reliability
3. Excellent tear resistance and aging resistance
4. Small air resistance.
Futures
High efficiency exchanger, saving more energy
Heat recovery calculating equation (Winter)
Indoor supply air temp. = (indoor air temp. – outdoor air temp.)* temp.
recovery efficiency + outdoor temp.
Example 14.8℃ = (20 ℃ – 0 ℃)*74% + 0 ℃
Futures

Compact design and low noise
•
Adopt sound absorption material, low noise.
•
Compact design, easy installation and maintenance.
Easy for installation
Installed under girder
Installed at anomalous space
Model:CE-HRV-200
Futures

Different modes for your choice
•
Exhausting mode (Hi Mid Low fan speed can be chosen)
•
Air supply mode (Hi Mid Low fan speed can be chosen)
•
By pass mode (Hi Mid Low fan speed can be chosen)
•
Heat exchanging mode (Hi Mid Low fan speed can be chosen)
•
Auto mode
In this mode,the unit will run at heat exchange mode or by pass mode judge by OD
temp. and ID temp. with low speed air flow.
Futures
Introduction of By pass mode
In this mode,there’s no heat exchanging happened,so saving energy.
For example:
If outdoor temp. is lower than indoor, we don’t need heat exchanging but we
need flesh air.We can choose by pass mode.
Remark: this mode only available for HRV-200~1000.
Introduction of Heat exchanging mode
In this mode,supply air flow = exhaust air flow.
Fresh-air and exhaust air cross the heat exchanger.Then heat exchanging happen.
Futures
Thanks to different modes
The yearly AC load reduced 15%
Heat exchanging mode
Saving 20% energy
Yearly
energy saving
15%
Saving 6% energy
Saving 2% energy
By pass mode
Supply/Exhaust mode
Futures

Flexible control method
•
Wired controller KJR-27B/E standard to
choose different mode and timer function.
•
Central controller CCM03 realize On/Off function together with VRF indoor units
Futures

Certification
•
CE certification has been obtained.
•
RoHS directive also.
Futures

Self diagnosis function
•
The unit can diagnose itself by the LED inside the E-box.
Structure & Dimensions
Structure & Dimensions
•
CE-HRV-200
Structure & Dimensions
•
CE-HRV-300~1000
Model
L
L1
W
W1
W2
H
C
G
N
N2
HRV-300
744
675
599
657
315
270
100
19
Φ144
111
HRV-400
744
675
804
862
480
270
100
19
Φ144
111
HRV-500
824
754
904
960
500
270
107
19
Φ194
111
HRV-800
1116
1045
884
940
428
388
85
19
Φ242
170
HRV-1000
1116
1045
1134
1190
678
388
85
19
Φ242
170
Structure & Dimensions
•
CE-HRV-1500
•
CE-HRV-2000
Fan performance
Fan performance
Fan performance
Fan performance
Specifications
Model
CE-HRV-200
CE-HRV-300
CE-HRV-400
CE-HRV-500
CE-HRV-800
Air volume(m3/h)
200
300
400
500
800
Static pressure(Hi) (Pa)
75
75
80
80
100
Cooling
Temp. efficiency (%)
60
60
60
60
60
Enthalpy efficiency(%)
50
50
50
50
50
Temp. efficiency (%)
65
65
65
70
70
Enthalpy efficiency (%)
55
55
60
60
60
Heating
Power supply (V-ph-Hz)
220~240-1-50
Type
Motor
Power (W)
20
40
80
120
360
Current (A)
0.5
0.56
1
1.2
2
666*580*264
744*599*270
744*804*270
824*904*270
1116*884*388
22/46
23/48
30/57
35.5/65.5
57.5/91.5
27
30
32
35
39
Dimension (L*W*H) mm
Net/Gross Weight(kg)
Noise level dB(A)
Controller
Asynchronous Motor
KJR-27B/E
Specifications
Model
CE-HRV-1000
CE-HRV-1500
CE-HRV-2000
Air volume (m3/h)
1500
1500
2000
Static pressure(Hi) (Pa)
150
160
170
Temp. efficiency (%)
60
60
60
Enthalpy efficiency (%)
50
50
50
Temp. efficiency (%)
70
70
70
Enthalpy efficiency (%)
60
60
60
Cooling
Heating
Power supply (V-ph-Hz)
Type
Motor
Dimension (L*W*H) mm
Net/Gross Weight(kg)
Noise level dB(A)
Controller
220~240-1-50
380-3-50
Asynchronous Motor
Asynchronous Motor
Power (W)
360
900
1100
Current (A)
2.4
3.2
3.6
1116*1134*388
1500*1200*540
1500*1200*540
59/95
160/200
175/215
40
51
53
KJR-27B/E
Thanks!
Download