INSTALLER ERV VER. 01- Jan. 2011 ENERGY RECOVERY VENTILATION [ERV Plus] SAMSUNG ELECTRONICS Co. LTD. HQ SE 1 Trainer Profile • Name : • E-mail : SAMSUNG ELECTRONICS CO.LTD 2 Contents ■ ERV + Basics SAMSUNG ERV ■ Key Technology ■ Controls & Solution ■ Case Study ■ ERV Line-up ■ Duct design SAMSUNG ELECTRONICS CO.LTD 3 ERV Plus Introduction ERV + ERV Plus introduction ERV Plus = ERV(Ventilator) + DX Coil + Humidifier(Option) 5 ERV+ USP High efficiency of motor ■ Power consumption comparison by models 500 CMH 255% 1000 CMH 131% 100% 100% Samsung Company D Capacity Samsung Company D 500 CMH 220W 560W 1000 CMH 510W 670W 6 ERV+ USP The Slimmest Height & Light Weight - The slim height makes installation, maintenance and repair very easy 270mm Div D Company M Company X Company Samsung 387mm 317mm 365mm 270mm 100% 82% 97% 71% 96kg 57kg 98kg 62kg 100% 59% 102% 64% Product Image Height Weight 7 ERV + USP Simple line up - ERV PLUS = ERV (Ventilator) + Dx-Coil (Air conditioner) + Humidifier(Optional) => Install humidifier to ERV Plus at any time. + ERV Plus Line Up Humidifier Kit D Company M Company X Company Samsung Humidifier Model Non-Humidifier Model (Separated Model) Humidifier Model Non-Humidifier Model (Separated Model) Humidifier Model Non-Humidifier Model (Separated Model) Non-Humidifier Model + Optional Humidifier Kit 8 ERV+ USP Filter high efficiency Samsung High Efficiency Medium-filter D company Pre-filter ■ Classified as high efficiency Medium-filter, while the other is defined as pre-filter ■ Dust spot efficiency is over 70% (based on ASHRAE Std 52.1) ■ Fractional efficiency is over 60% (based on MIL,STD-282) Composition Filter media Frame Hot melt Spec. Media PP + PET Spun bond Composition PP + PET Nonwoven Weight 120g/㎡ ± 10% Material PET Weight 260g/㎡ ± 20% Material Nylon Softening point 139 ~ 149 ℃ 9 ERV+ USP Class Standard 52.2 Min. Efficiency Reporting Value (MERV) 1 2 3 Pre filter 4 5 6 7 8 9 10 Medium Filter HEPA ULPA Pre/Medium (EN 779) HEPA/ULPA (EN1822) G1 D company Panel Type Compact Pocket Type G2 G 35 MP 35 F 40 / F 45 G3 G4 Samsung Compact Pocket Type Compact ECO Pocket Type F5 11 F6 12 F7 13 F8 14 F9 15 H 10 16 H 11 17 H 12 18 H 13 19 H 14 20 U 15 F 50 EP Series MF Series HEPA ULPA SF Series U 16 U 17 10 ERV + Basic Structure of ERV Plus Total heat exchanger element Humidifier (Option) Exhaust Air Outdoor Air Return Air Supply Air Access panel Filter PCB DX Coil Damper 11 ERV + Basic Schematic diagram of ERV Plus < DX Coil specification> Return air temp. sensor Suction air temp. sensor ERV Plus Eva out temp. sensor Total heat exchanger OA temp. sensor DX Coil RHF050KHEA RHF100KHEA L : 340 mm 2Row x 12 step L : 644 mm 3Row x 14 step Fin 1.5 FP, Slit DX coil Eva in temp. sensor Humidifier Gas pipe < EDM type EEV> EEV Liquid pipe Water feed pipe EEV RHF050KHEA RHF100KHEA DPF(Q) 1.3 DPF(Q) 2.0 - Max. 1400 step 12 ERV + Basic The specification of RHF050KHEA Classification Air flow rate Unit Samsung (RHF050KHEA) D (VKM500GAMV1) Air flow rate (㎥/h) 500 500 Static pressure (Pa) 160 180/*160 (W) 220 560 cooling (%) 70 76 heating (%) 75 76 cooling (%) 60 64 heating (%) 73 67 cooling (KW) 5.1 (ERV:1.5) 4.71 (ERV:1.91) heating (KW) 6.5 (ERV:2.5) 5.58 (ERV:2.38) (kg/h) 2.7 2.7 (dB) 38.5/* 37.5 38.5/* 37.5 (kg) 61 / * 63 96 /* 102 (mm) 1553*270*1000 1764*387*1214 Power input Ventilation performance Temp. exchange efficiency Enthalpy exchange efficiency Outdoor air processing capacity Humidifying capacity Sound level Set size extra high * Including humidifier 13 13 ERV + Basic The specification of RHF100KHEA Classification Air flow rate Ventilation performance Unit Samsung (RHF100KHEA) D (VKM100GAMV1) Air flow rate (㎥/h) 1000 950 Static pressure (Pa) 150 150 / *110 (W) 510 670 cooling (%) 70 74 heating (%) 75 74 cooling (%) 62 62 heating (%) 75 65 cooling (KW) heating (KW) 10.5 (ERV:3.4) 13.2 (ERV:5.2) 9.12 (ERV:3.52) 10.69 (ERV:4.39) (kg/h) 5.4 5.4 (dB) 40.5/* 39.5 40.5/* 39.5 (kg) 90 / * 93 114 / * 125 (mm) 1763*340*1135 1764*387*1214 Power input Temp. exchange efficiency Enthalpy exchange efficiency Outdoor air processing capacity Humidifying capacity Sound level Set size extra high * Including humidifier 14 14 ERV + Basic Psychrometric chart plotting with cooling operation 100 < Example> 80 60 71.7 kJ/Kg 62.82 kJ/Kg Total heat exchanger Heat recovery DX Coil 40 53.77 kJ/Kg ERV Plus cooling performance Cooling SA Cooling Cooling 35℃ RH 40% 20 RA 27℃ RH 47% -5 0 5 10 Absolute Humidity (kg/kg’) OA 15 20 25 30 35 40 Dry bulb (℃) 29.5℃ RH 50.2% 32.4℃ RH 38% Temperature Efficiency 13.3℃ RH 80% t(OA) t( SA) 100 t(OA) t( RA) Enthalpy efficiency ratio Enthalpy Efficiency h(OA) h( SA) 100 h(OA) h( RA) 71.7 62.82 100 71.7 53.77 = 49.5 % 15 ERV + Basic Psychrometric chart plotting with heating operation 100 < Example> 80 60 Total heat exchanger 40 DX Coil Humidifier 41.91 kJ/Kg 20/15 ℃ 36.6 kJ/Kg Humidifying RA Heat recovery heating Humidifying 20.61 kJ/Kg 20 OA Absolute Humidity (kg/kg’) 2/1℃ SA Heating 20℃ RH 59% 7℃ RH 87% 16.4℃ RH 67% 10.6℃ RH 79% 40 ℃ RH 12.2 % 29.5℃ RH 40% -5 0 5 10 15 20 25 30 35 40 Dry bulb (℃) Enthalpy efficiency h( SA) h(OA) 100 h( RA) h(OA) 36 .6 20 .61 100 = 75 % 41 .91 20 .61 16 Operation mode Operation mode Energy recovery(Heat-Ex) and By-pass ventilation Air flow Damper Energy recovery (Heat exchange) By-pass <Wired remote controller> <Energy recovery mode display> <By-pass mode display> 18 Operation mode Auto ventilation -According to OA and Return air temperature, the mode is determined. - The operation mode will be operating during 30 min. Condition Energy recovery (Heat exchange) |OA temp. –RA temp| >= 5℃ By-pass |OA temp. –RA temp| < 5℃ Return air temp. sensor Outdoor air temp. sensor 19 Operation mode Clean up operation -To make positive or negative pressure of room, supply and exhaust air volume can be different by Clean up operation . Switch 17 state Supply air volume Exhaust air volume On Selected fan mode Silent fan mode Off Silent fan mode Selected fan mode Air volume difference Max. 35 % (Turbo and high fan mode) -To avoid toilet odor, more air volume 10 ~ 15% have to supply to make positive pressure of living Toilet Living Room Positive pressure 20 Operation mode Outing operation Operation mode Fan Energy recovery ventilation On : 10 min, Off : 50 min Low Quite operation -The fan mode is fixed to the quite mode. Fan mode RHF050KHEA RHF100KHEA Turbo 38.5 40.5 High 36 38 Low 32 35 Quite 30 33 21 Operation mode Energy saving operation : Energy saving operation is run when all the following conditions are met. 1) One or more ERV units must be connected to MWR-WE10 (without or with indoor unit(s) ) 2) Either the indoor unit or ERV must be ON (if the indoor unit is ON, it must not be FAN mode). 3) ERV must not be in Outing mode 4) ERV external control must not be enabled. 5) ERV must not be in “Centralized” control mode. 6) ERV must not be in “Kitchen Hood” control mode. NOTE : The sub wired remote controller does not support energy saving mode 22 Operation mode Energy saving operation Cooling Default setting temperature : 26°C. User can change it Heating R : Room temperature / S : Setting temperature Default setting temperature : 22°C. User can change it R 26°C S S 22°C R Energy Saving Out temp < Set temp : Cool air intake ↑ Out temp < Room temp : Cool air intake ↑ Set temp < Out temp : Warm air intake ↑ Room temp < Out temp : Warm air intake ↑ Out temp >= Set temp : Heat exchange ↑ Out temp >= Room temp : Heat exchange ↑ Set temp >= Out temp : Heat exchange ↑ Room temp >= Out temp : Heat exchange ↑ 23 Operation mode Auto operation (DX coil) Suction air temp. sensor Cooling operation A area B area Suction air temp >= auto cooling setting temp.(*25 ℃) Thermo off (Ventilation operation) Heating operation C area Suction air temp < auto cooling setting temp – Thermo off gap temp. (*25℃ – 10℃*) Set temp. range : Auto cooling set temp. : 15℃ ~ 30℃ Thermo off gap temp. : 5℃ ~ 15℃ Outdoor air temp. sensor Outdoor air temp. sensor * Default value can be changed by wired remote controller (SVC mode) 24 Operation mode Heating operation (DX coil) -After working of ventilation mode, cooling and heating mode of DX coli is possible. Thermo on Thermo off Remark Cooling Suction air temp >= *Default set temp. Suction air temp <= *Default set temp. – 4℃ *Default cooling set temp. : 25℃ (Set temp range : 15 ~ 30℃) Heating Suction air temp <= *Default set temp. + **Compensation temp. - 6 Suction air temp >= *Default set temp. + **Compensation temp. - 2 *Default cooling set temp. 22℃ **Compensation temp. : 2, 5 ℃ 25 Safety operation Prevention of condensate System is capable of self adjustment depending on outdoor temperature to prevent it from condensate on element Outdoor Temp Operation Type Above 0℃ Normal Operation 0 ℃ > TOA >-5 ℃ “A” Type Cyclic Operation Discharge On On Refer to below operation pattern “B” Type Cyclic Operation -5 ℃ > TOA >-10 ℃ Intake -10 ℃ > TOA >-15 ℃ Off On Below -15 ℃ Off Off ‘A’ Type 80min Both Intake and Discharge On ‘B’ Type 50min Both Intake and Discharge On 10min Only Discharge On 10min Only Discharge On 80min Both Intake and Discharge On 50min Both Intake and Discharge On Remarks Repeated on a regular time basis 10min Only Discharge On 10min Only Discharge On 26 Fan operation with CO2 sensor Refresh system - CO2 Sensor( option) CO2 Fresh Air CO2 CO2 Note 1. K9 dip switch should be off position 2. In general, above 1000ppm is regarded as pollution ☞ ERV is automatically operated to give fresh air into room by sensing CO 2 Level Fan Speed depending on Co2 density □ CO2 1200ppm ↑ : Turbo RPM □ CO2 Density 800ppm ↑ : High RPM □ CO2 Density 800ppm ↓ : Low RPM 27 Humidification Humidification Comparison of Humidifier kit D Company Samsung Method Vaporizing(Evaporating) (Indirect water supply) Vaporizing(Evaporating) (Direct water supply) Material PET (Poly Ethylene Terephthalate) Ceramic Image Need to clean It is possible that dust can stick the material Cleanliness during airflow and bacteria can breed in drain pan Life Relatively Short Possibility of corrosion and contamination is higher than Inorganic material as compared with mineral material Don’t need to clean because Self-Cleaning Relatively Long Because ceramic itself is inorganic material, possibility of corrosion and contamination is relatively low 29 Humidification Components of Humidifier kit (Option ) Humidifier kit RHF050KHEA RHF100KHEA Model MVO-VA050100 MVO-VA100100 Pressure regulation valve Solenoid valve Strainer (1/2 Inch) Humidifier element Bracket Water feed pipe Connecting hose Connecting hose Regular flow rate RHF050KHEA RHF100KHEA 0.2 L/min 0.4 L/min 30 Humidification Humidifier kit assembling K4 switch in PCB : Off position Water spray hose <Floating switch installation> <Connection of hose> <Connection wiring of float switch and solenoid valve> <Installation of water feed pipe> <Insulation> 31 Humidification Maintenance of humidifier kit Intake air temperature : 0 ~ 40 ℃ Supply water temperature : 2 ~ 40 ℃ Supply water pressure : 0.08 ~ 0.7 Mpa Use soft water Use neutral detergent for cleaning 32 PCB ERV Plus • PCB Test run button IR sensor Operation/Error output EEV EA motor Main address RMC address SW debugging External damper Room temp. EVA in/out temp. CO2 sensor SA motor (250VAC, 0.5A) Inductor Main power input EA temp. OA temp. Humidifier Option switch Software upgrade Float switch MPI Damper feedback Internal damper Comm. with outdoor unit (F1-F2) Power supply to wired R/C (V1-V2) Comm. with wired R/C (F3-F4) Humidity control Hood contact External control 34 ERV Plus • Power/Communication wiring ERV ERV ERV SAFE! L L N F1 F2 L N F1 F2 N F1 ERV Plus F2 EHP ERV Plus L L N F1 F2 L N F1 F2 N F1 F2 35 ERV Plus • Push button Operation PUSH When humidifier is used (K4=ON) Power LED 230VAC output to open the humidifier valve. The LED lamp blinks one time Damper operation * Opens and closes one time. * Keep the humidifier valve opened The LED lamp blinks two times. Supply / Exhaust FAN operation * Turbo breeze is generated Supply / Exhaust Fan operation * Turbo breeze is generated * Keep the humidifier valve opened The LED lamp blinks three times. Exit test run Cancel the trial operation No 230VAC output to close the humidifier valve. Return to the normal state. 1st No operation 2nd Damper operation * Opens and closes one time 3rd 4th When humidifier is not used (K4=OFF) 36 ERV Plus • Option switch SW No. Function ON OFF K1 Remote sensor No use Use K2 Central control No use Use K3 - - - K4 Humidifier No use Use K5 Heating temperature compensation 2℃ 5℃ K6 Filter time 1000 hours 2000 hours - - K7, K8 - K9 EEV stop step in heating 160 35/160 K10 Priority of display on wired R/C Low High K11 External control No use Use K12 State output Output during operation Output during thermo-on - - K13, K14 - K15 External damper No use Use K16 MPI No use Use K17 CO2 sensor No use Use K18 Special EEV control skip in heating No use Use K19 Clean-up K20 - Exhaustion air RPM fixed to RPM in Quiet mode - Supply air RPM fixed to RPM in Quiet mode - 37 ERV Plus • Error code Error code Detail E101 No communication between indoor unit and outdoor unit (The indoor unit itself does not receive any communication signal from the outdoor unit) E102 Communication error(s) occurred in other indoor unit(s). (The indoor unit itself succeeded communicating with the outdoor unit) E122 EVA-IN sensor error (open/short) E123 EVA-OUT sensor error (open/short) E128 EVA-IN sensor separated from the pipe E129 EVA-OUT sensor separated from the pipe E151 EEV opened E152 EEV closed E161 Mixed mode operation E174 Heat exchanger suction air sensor(open/short) E201 Communication error between outdoor unit and indoor unit(s) due to the mismatching of the set number and installed number during tracking E121 Indoor temperature sensor error (open/short) E221 Outdoor temperature sensor error (open/short) 38 ERV Plus • Error code Error code Detail E139 CO2 sensor error (detached or no feedback) E162 EEPROM error (read/write failure) E163 EEPROM option setting error (wrong option code setting) E186 MPI Error (detached or no feedback) E561 Supply Air fan motor error (RPM less than 120 for 40 seconds) E562 Exhaust Air fan motor error E654 Damper error (When there is no feedback for 100 seconds after damper drive output) E490 No operation due to low outdoor temperature (Outdoor temp. < 0 ℃ and heat-EX suction air temp. < 0 ℃) 39 ERV Plus • Connection with wired remote controller F4 F3 V2 V1 F4 F4 F3 F3 V2 V1 V1 V2 MWTR-WE10 Wire specifications : 4-wire 0.75 ~ 1.5mm2 VCTF or equivalent Wiring length : max. 100m 40 ERV Plus • Energy saving operation – EHP-ERV combined : The operation of an ERV-combined indoor unit is not interfered by energy saving operation, but performs temperature control as it usually does. ERV Plus MWR-WE10 EHP F3-F4 EHP ERV Plus When the E.Saver button is pressed ON - ERV : current operation mode Energy saving operation - EHP : No change in operation - ERV controlled by room temperature (sensed by EHP or wired R/C), set temperature and indoor temperature (sensed by ERV) ON (no Fan mode) OFF - ERV : OFF energy saving operation - EHP : No change in operation - ERV controlled by room temperature (sensed by EHP or wired R/C), set temperature and indoor temperature (sensed by ERV) OFF ON - ERV : current operation mode Energy saving operation - EHP : No change in operation OFF OFF - No energy saving operation ON (no Fan mode) 41 ERV Plus • Energy saving operation – ERV only ERV Plus MWR-WE10 LOW MEDIUM HIGH F3-F4 TURBO ERV Plus When the E.Saver button is pressed ON - Operated in Heat Exchange, LOW fan speed with repeating sequence of 30-minute operation and 30-minute stop OFF - No Energy Saving operation - “Restricted” displayed on wired R/C User command ERV operation Energy Saving mode By-Pass mode by MWR-WE10 HIGH fan speed Heat Exchange LOW fan speed By-Pass HIGH fan speed Energy saving mode 30 minutes OFF Heat Exchange LOW fan speed By-Pass mode 30 minutes 42 ERV Plus - Operation/Error state output : ERV operation/error state output enabled by option setting (K12=OFF) ERV Plus error 12VDC, 500mA Comp. operation 12VDC, 500mA 4-wire cable of MIM-B14 ERV Plus error voltage-free contact open Rating : 250ADC, 3A ERV Plus ON voltage-free contact closed Rating : 250VAC, 3A MIM-B14 환기 ON or DX-coil ON ??? 43 ERV Plus - External control - ERV ON/OFF control by external contact switch (enabled by option setting K11=OFF) - Add the 6th digit of the option code by 8 to switch to OFF-only control mode Option code External control Kitchen hood control Humidifier control Model ON/OFF control OFF-only control RHF050KHEA 015617-152380-200000-300000 01561F-152380-200000-300000 RHF100KHEA 015617-1C2373-200000-300000 01561F-1C2373-200000-300000 Switch state = ON Switch state = OFF ON OFF ON/OFF control ERV operation Wired R/C Able to use Able to use OFF-only control ERV operation Unchanged OFF Wired R/C Able to use Unable to use External control system Type : Voltage-free switch Tating : 5VDC, 5mA Cable : Unshielded TP 2-wire of 0.75mm2 or greater, VCTF or equivalent Length : Max. 100 meters 44 ERV Plus - Kitchen hood control : No need to set the option switch to enable kitchen hood control External control Kitchen hood control Kitchen hood Humidifier control Cable : Unshielded TP 2-wire, 0.75mm2 or greater, VCTF or equivalent Length : Max. 100 meters Type : Voltage-free switch Rating : 5VDC, 5mA - Kitchen hood mode - SA RPM : Turbo, EA RPM : Mid Kitchen hood switch ON (closed) OFF (open) ERV operation Wired R/C Normal Kitchen hood mode “Hood” displayed in normal display OFF Kitchen hood mode “Hood” displayed in OFF Kitchen hood mode Normal “Hood” disappeared Kitchen hood mode OFF “Hood” disappeared NOTE : The fan speed can be changed by the wired remote controller in kitchen hood mode. 45 ERV Plus - Humidify control : Humidity control by humidifier and locally purchased humidity sensor enabled by option setting (K4=OFF) External control Kitchen hood control 1. Basic operation Humidifier control Samsung Humidifier Humidity sensor (locally purchased) Cable : Unshielded TP 2-wire, 0.75mm2 or greater, VCTF or equivalent Length : Max. 100 meters a. Humidity control enabled by option setting b. Humidity control input closed : Humidifier stop c. Humidity control input open : No change 2. Humidity sensor switch specifications a. Type : Voltage-free switch b. Rating : 5VDC, 5mA 3. Operation sequence a. Humidifier operation by wired remote controller b. Humidity level increase c. Humidity sensor switch closed at the set level d. Humidifier stop 46 ERV Plus - External damper control : External damper control or interlocking signal enabled by option setting (K13=OFF) ERV operation DAMPER output ON 230VAC (max. 0.5A) OFF No voltage Direct connection to external load (load current : below 0.5A) Relay/Magnet switch Connection to external load via relay/magnet (load current : over 0.5A) 47 ERV Plus - Internal damper control : The internal damper is controller by pulse detection sensed by the micro switch and interval between pulses. 1 Four pulses one rotation 3 2 1 3 2 T1 T2 T3 T1, T2 : short interval, T3 : Long interval 3 By-Pass mode Heat Exchange mode 1. Internal damper operation start 2. Pulse from switch detected by controller. 3. Damper stop in detection of two short interval pulses 1. Internal damper operation start 2. Pulse from switch detected by controller. 3. Damper stop in detection of one long interval pulse • Damper error - After the damper starts operating, E654 is displayed when the pulse from the switch is not detected for 100 seconds. 48 ERV Plus • CO2 sensor (MOS-C1) - Pulse width variation depending on CO2 level (pulse period = 1004ms) 2ms ppm 0ppm 4ms 2000 4ppm 1002ms 2 CO2 sensor 1002 H L OK H L NG H L NG Pulse width 2ms 2000ppm - Two minutes after power-on, the CO2 sensor is maintained at 500RPM as preheating standby - An error is detected when the pulse from the CO2 sensor is not generated for 2 minutes. 49