SITE CLASSIFICATION SITE PLAN NOTES ALL MATERIALS & WORK PRACTICES SHALL COMPLY WITH, BUT NOT LIMITED TO THE BUILDING REGULATION 2006, THE NATIONAL CONSTRUCTION CODE SERIES 2012 BUILDING CODE OF AUSTRALIA VOLUME 1 & ALL RELEVANT CURRENT AUSTRALIAN STANDARDS (AS AMENDED) REFERRED TO THEREIN SITE SOIL CLASSIFICATION IS CLASS: H-D PREPARED BY: CIVIL TEST PTY LTD REPORT NO: 3110001 REFER TO THE SOIL REPORT, COMMENTS & RECOMMENDATIONS CONTRACTOR TO INFORM THE ENGINEER OF ANY AREAS THAT ARE SUSPECT OR DIFFERENT FROM THE MATERIALS DESCRIBED IN THIS REPORT PRIOR TO PROCEEDING 1. ALL SITE DIMENSIONS ARE IN METRES UNLESS SPECIFIED OTHERWISE 2. BUILDER TO VERIFY ALL DIMENSIONS, SETBACKS & LEVELS PRIOR TO COMMENCEMENT OF ANY WORKS. REPORT ALL DISCREPANCIES TO THIS OFFICE FOR CLARIFICATION. 3. REFER TO PLAN OF SUBDIVISION OR CERTIFICATE OF TITLE FOR VERIFICATION OF ALL BEARINGS, DISTANCES AND OTHER SITE INFORMATION. CONTRACTOR IS TO VERIFY BOUNDARY LOCATION ON SITE PRIOR TO THE COMMENCEMENT OF WORK FILL USED ON SITE SHOULD BE PLACED AT OR NEAR OPTIMUM MOISTURE CONTENT AND COMPACTED IN ACCORDANCE WITH THE REQUIREMENTS OF SECTION 3.9 OF AS 2870-1996, AS SUMMARISED BELOW: 4. FOR DETAILS OF ALL EASEMENTS REFER TO THE PLAN OF SUBDIVISION OR CERTIFICATE OF TITLE AND OTHER INFORMATION BY THE RESPONSIBLE AUTHORITY. (A) NON-SAND FILL UP TO 300mm IN DEPTH OR SAND FILL UP TO 600mm DEEP, COMPACTED IN NOT MORE THAN 150mm LAYERS BY REPEATED ROLLING BY AN EXCAVATOR, IS CLASSED AS ROLLED FILL AND MAY BE USED FOR SUPPORT OF SLAB PANELS AND INTERNAL BEAMS. NOTE THAT EDGE BEAMS MUST BE SUPPORTED ON ORIGINAL GROUND OR ON CONTROLLED FILL AS DEFINED IN (B) BELOW: 5. INSTALLATION OF ALL SERVICES INCLUDING ALL STORMWATER, WASTE WATER AND SEWER DETAILS SHALL COMPLY WITH THE RESPECTIVE SUPPLY AUTHORITY REQUIREMENTS. 6. THE CONTRACTOR AND SUBCONTRACTOR SHALL ENSURE THAT ALL STORMWATER DRAINS, SEWER PIPES AND THE LIKE ARE LOCATED AT A SUFFICIENT DISTANCE FROM ANY BUILDINGS FOOTINGS AND / OR SLAB EDGE BEAMS SO AS TO PREVENT GENERAL MOISTURE PENETRATION, DAMPNESS, WEAKENING AND UNDERMINING OF ANY BUILDING AND ITS FOOTING SYSTEM. 7. INSTALL NEW METER BOX IN STEEL CABINET IN STRICT ACCORDANCE WITH POWER SUPPLIERS REQUIRMENTS, BCA & ALL AUSTRALIAN STANDARDS 8. CONTRACTOR TO PROVIDE UNDERGROUND POWER SUPPLY FROM EXIST ELEC. PIT/ OR PILLAR TO NEW METER BOX IN ACCORDANCE WITH POWER SUPPLIERS REQUIREMENTS 9. INSTALL NEW WATER METER. ENSURE METER IS EQUIPPED WITH A BACKFLOW PREVENTION DEVICE & STOP TAP. CONNECT TO RESIDENCE IN ACCORDANCE WITH LOCAL AUTHORITIES REQUIREMENTS ALL MATERIALS & CONSTRUCTION PRACTICE SHALL MEET THE PERFORMANCE REQUIRMENTS OF THE BCA. WHERE AN ALTERNATIVE SOLUTION IS PROPOSED THEN, PRIOR TO IMPLEMENTATION OR INSTALLATION, IT FIRST MUST BE ASSESSED & APPROVED BY THE RELEVANT BUILDING SURVEYOR AS MEETING THE PERFORMANCE REQUIRMENTS OF THE BUILDING CODE OF AUSTRALIA THE CONTRACTOR & SUBCONTRACTORS SHALL CHECK & VERIFY ALL DIMENSIONS, SETBACKS, LEVELS & SPECIFICATIONS & ALL OTHER RELEVANT DOCUMENTATION PRIOR TO THE COMMENCEMENT OF ANY WORKS OR PREPARING SHOP DRAWINGS. REPORT ALL DISCREPANCIES TO THIS OFFICE FOR CLARIFICATION. ALL DIMENSIONS ARE IN MILLIMETERS U.N.O. IF IN DOUBT ASK, DO NOT SCALE. THESE DRAWINGS SHALL BE READ IN CONJUNCTION WITH ALL RELEVANT STRUCTURAL & ALL OTHER CONSULTANTS DRAWINGS / DETAILS & WITH ANY OTHER WRITTEN INSTRUCTIONS ISSUED IN THE COURSE OF THE CONTRACT THESE DRAWINGS SHALL BE READ IN CONJUNCTION WITH ANY ENERGY RATING REPORT & SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE STAMPED PLANS ENDORSED BY THE ACCREDITED THERMAL PERFORMANCE ASSESSOR WITHOUT ALTERATION ALL NEW CONSTRUCTION WORK & THE INSTALLATION OR ALTERATION OF EXISTING SERVICES SHALL COMPLY WITH THE 'BUILDING CODE OF AUSTRALIA', RELEVANT 'AUSTRALIAN STANDARDS', RELEVANT CODES & MANUALS, LOCAL MUNICIPAL BY-LAWS & THE REQUIREMENTS OF THE RESPECTIVE SUPPLY AUTHORITIES REQUIREMENTS. ALL FITTINGS, FIXTURES, PAINTING, ETC. TO PROPRIETORS REQUIREMENTS. CONTRACTOR MUST ENSURE ALL NECESSARY PERMITS ARE OBTAINED & ALL FEES ARE PAID FOR PRIOR TO THE COMMENCEMENT OF WORK. THE CONTRACTOR SHALL TAKE ALL STEPS NECESSARY TO ENSURE THE STABILITY & GENERAL WATER TIGHTNESS OF ALL NEW &/OR EXISTING STRUCTURES DURING ALL WORKS. ALL DRAINAGE WORK SHALL BE IN STRICT ACCORDANCE WITH AS 3500 AND THE RESPECTIVE AUTHORITIES REQUIREMENT AND INDUSTRY CODES. THE ELECTRICAL SERVICES SHALL BE INSTALLED IN ACCORDANCE WITH THE REQUIREMENTS AND REGULATIONS OF ALL AUTHORITIES AND CODES RELEVANT TO THE WORKS INCLUDING BUT NOT LIMITED TO AS 3000 - AUSTRALIAN WIRING RULES, SERVICE & INSTALLATION RULES & NCC THESE PLANS HAVE BEEN PREPARED FOR THE EXCLUSIVE USE BY THE CLIENT OF 'ECOTECTURE DESIGN GROUP' ('THE DESIGNER') FOR THE PURPOSE EXPRESSLY NOTIFIED TO THE DESIGNER. ANY OTHER PERSON WHO USES OR RELIES ON THESE PLANS WITHOUT THE DESIGNERS WRITTEN CONSENT DOES SO AT THEIR OWN RISK & NO RESPONSIBILITY IS ACCEPTED BY THE DESIGNER FOR SUCH USE &/OR RELIANCE. THE APPROVAL BY THIS OFFICE OF A SUBSTITUTE MATERIAL, WORK PRACTICE, VARIATION OR THE LIKE IS NOT AN AUTHORIZATION FOR ITS USE OR A CONTRACT VARIATION. ANY SAID VARIATIONS MUST BE ACCEPTED BY ALL PARTIES TO THE AGREEMENT & WHERE APPLICABLE THE RELEVANT BUILDING SURVEYOR PRIOR TO IMPLEMENTING THE SAID VARIATION. No. 3-5/ 33 Nish Street, Echuca 3564 566 St Kilda Road, Melbourne 3004 admin@ecotecturedesign.com.au 03 54807884 Description COMPACT FILL NOTES (B) NON-SAND FILL UP TO 400mm IN DEPTH OR SAND FILL UP TO 800mm DEEP, COMPACTED BY MECHANICAL ROLLER OR VIBRATING PLATE RESPECTIVELY, IN LAYERS NOT MORE THAN 150mm THICK AND AT CLOSE TO OPTIMUM MOISTURE CONTENT, IS DEEMED TO COMPLY AS CONTROLLED FILL. IT IS DEEMED TO COMPLY AS SUITABLE FOR FOUNDING THE SLAB, EDGE AND INTERNAL BEAMS. THE REQUIREMENTS OF AS 2870-1996 FOR CONSTRUCTION OF THE FOOTINGS AND LANDSCAPING OF THE SITE SHOULD BE FOLLOWED, WITH PARTICULAR ATTENTION PAID TO SURFACE DRAINAGE AND AVOIDANCE OF PONDING NEXT TO FOOTINGS. TREES SHOULD BE PLANTED NO CLOSER TO THE FOOTINGS THAN 1.0x MATURE HEIGHT. SHOULD SOIL CONDITIONS DIFFERING THAN DESCRIBED BE FOUND DURING EXCAVATION WORKS, ESPECIALLY THE PRESENCE OF UNREPORTED FILL OR POORLY COMPACTED MATERIAL, PLEASE CONTACT THIS OFFICE SERVICES THE CONTRACTOR & SUBCONTRACTOS SHALL ENSURE THAT ALL STORMWATER DRAINS, SEWER PIPES & THE LIKE ARE LOCATED AT A SUFFICIENT DISTANCE FROM ANY BUILDING FOOTING & / OR SLAB EDGE BEAM SO AS TO PREVENT GENERAL MOISTURE PENETRATION, DAMPNESS, WEAKENING & UNDERMINING OF ANY BUILDING & ITS FOOTING SYSTEM THE CONTRACTOR SHALL COORDINATE THE LAYING OF SERVICES TO AVOID CLASHES. LAY ALL SERVICES TO LOCATIONS. SERVICES SHALL BE LAID TO COMPLY WITH MINIMUM COVER REQUIREMENTS. DIFFERENT PARALLEL SERVICES THAT ARE IN CLOSE PROXIMITY MAY BE LAID IN A COMMON BENCHED TRENCH SUBJECT TO APPROVAL OF RELEVANT AUTHORITIES. BACK FILL OF ALL SERVICES TRENCHES UNDER PAVEMENTS AND 500mm BEYOND SHALL BE CLASS 2 FROM ABOVE THE SERVICE BEDDING MATERIAL TO THE UNDERSIDE OF PAVEMENT SUB-BASE. 10. CONNECT RESIDENCE WITH TELSTRA CABLES IN STRICT ACCORDANCE WITH TELSTRA'S REQUIREMENTS 11. CONNECT WATER SUPPLY TO THE SANITARY ITEMS WITHIN THE PROPOSED BUILDING & HWS WHERE REQUIRED IN ACCORDANCE WITH LOCAL AUTHORITIES REQUIREMENTS. SUPPLY HOT & COLD WATER TO NEW SANITARY ITEMS AS REQUIRED 12. CONNECT ALL SANITARY ITEMS WASTE PIPES WITHIN RESIDENCE WITH CLASS12 PVC-U 100mmø DWV LAID ON MIN. 1:60 FALL. CONNECT TO EXIST. SEWER MAIN IN ACCORDANCE WITH LOCAL AUTHORITIES REQUIREMENTS CONTRACTOR TO VERIFY SEWER CONNECTION POINT ON SITE 13. CONNECT ALL SANITARY ITEMS WASTE PIPES WITHIN RESIDENCE WITH CLASS12 PVC-U 100mmø DWV LAID ON MIN. 1:60 FALL. CONNECT TO PROPOSED SEPTIC TANK IN ACCORDANCE WITH LOCAL AUTHORITIES REQUIREMENTS CONTRACTOR TO VERIFY CONNECTION POINT & LOCATION OF SEPTIC ON SITE 14. CONNECT ALL DOWNPIPES WITH 90mmø UPVC STORM WATER DRAIN & CONNECT TO LEGAL POINT OF DISCHARGE IN ACCORDANCE WITH LOCAL AUTHORITIES REQUIREMENTS BACK FILL OF ALL SERVICES TRENCHES IN GARDEN AND GRASS AREAS SHALL BE APPROVED FILL OF MAXIMUM PARTICLE SIZE 75mm FROM THE SERVICE BEDDING MATERIAL TO THE UNDERSIDE OF THE TOPSOIL. Date ALTERATIONS & ADDITION TO DUMOSA & TOWANINNIE PUBLIC HALL PIONEER SETTLEMENT TENDER ISSUE WORKING DRAWINGS Project number Date Drawn by 2014-0044 NOVEMBER 2014 Scale ABN. 58 918 283 483 WD01 MCL Sheet WD01 Of RBP: DP-AD 18414 WD14 12/11/2014 9:16:01 AM UNLESS OTHERWISE SPECIFIED, THE TERM BCA SHALL REFER TO NATIONAL CONSTRUCTION CODE SERIES 2013 BUILDING CODE OF AUSTRALIA VOLUME 1 \\WIN7-PC\Users\Public\Documents\Drawings\2014-0044 - Dumosa Hall\WD01A.rvt GENERAL NOTES DEMOLITION NOTES SURFACE FALLS REMOVAL OF BUILDING BY ROAD MUST BE APPROVED BY RELEVANT COUNCILS TRAFFIC ENGINEER PRECAUTIONS MUST BE TAKEN BEFORE & DURING DEMOLITION IN ACCORDANCE WITH AS 2601-2001 DEMOLITION OF STRUCTURES. A SITE MANAGEMENT PLAN IS TO BE IMPLEMENTED DURING DEMOLITION WORKS TO CONTROL SEDIMENT RUNOFF IN ACCORDANCE WITH EPA VICTORIA PUBLICATION # 275: CONSTRUCTION TECHNIQUES FOR SEDIMENT POLLUTION CONTROL. PROVIDE 'PROPEX' OR EQUIVALENT SILT FENCES TO THE LOW SIDE OF THE ALLOTMENT & AROUND ALL SOIL STOCKPILES & STORM WATER INLET PITS / SUMPS & INSTALL 'SILT STOP' FILTER BAGS OVER ALL STORM WATER ENTRY PITS DURING DEMOLITION WORKS. 'SUPERGRO' OR EQUIVALENT EROSION CONTROL FABRIC TO BE PLACED OVER GARDEN BEDS TO PREVENT SURFACE EROSION DURING REVEGETATION PERIOD. DURING THE PROGRESS OF THE DEMOLITION THE WORKS SHALL BE UNDER THE CONTINUOUS SUPERVISION OF THE DEMOLISHER OR OF AN EXPERIENCED FOREMAN & DEMOLITION SHALL BE EXECUTED STOREY BY STOREY COMMENCING AT THE ROOF & WORKING DOWNWARDS. THE DEMOLITION MUST NOT BE COMMENCED UNTIL THE PRECAUTIONARY MEASURES HAVE BEEN INSPECTED AND APPROVED BY THE RELEVANT BUILDING SURVEYOR ALL FIXTURES & SANITARY ITEMS REMOVED WILL REMAIN PROPERTY OF THE PROPRIETOR. THE DEMOLISHER SHALL CONSTRUCT A TEMPORARY CROSSING PLACED OVER THE FOOTPATH AS REQUIRED BY THE COUNCIL PROTECTIVE OUTRIGGERS, FENCES, AWNINGS, HOARDINGS, BARRICADES & THE LIKE MUST BE INSTALLED WHERE NECESSARY TO GUARD AGAINST DANGER TO LIFE OR PROPERTY OR WHEN REQUIRED BY THE RELEVANT BUILDING SURVEYOR. DUST CREATING MATERIAL, UNLESS THOROUGHLY DAMPENED DOWN, SHALL NOT BE THROWN OR DROPPED FROM THE BUILDING BUT SHALL BE LOWERED BY HOISTING APPARATUS OR REMOVED BY MATERIAL CHUTES. ALL CHUTES SHALL BE COMPLETELY ENCLOSED & A DANGER SIGN SHALL BE AT THE DISCHARGE END OF EVERY CHUTE. ALL PRACTICABLE PRECAUTIONS SHALL BE TAKEN TO AVOID DANGER FROM COLLAPSE OF A BUILDING WHEN ANY PART OF A FRAMED OR PARTLY FRAMED BUILDING IS REMOVED. NO WALL, CHIMNEY OR OTHER STRUCTURE OR PART OF A STRUCTURE SHALL BE LEFT UNATTENDED OR UNSUPPORTED IN SUCH A CONDITION THAT IT MAY COLLAPSE DUE TO WIND OR VIBRATION OR OTHERWISE BECOME DANGEROUS. BEFORE DEMOLITION IS COMMENCED & ALSO DURING THE PROGRESS OF SUCH WORKS ALL ELECTRICAL CABLE OR APPARATUS WHICH ARE LIABLE TO BE A SOURCE OF DANGER OTHER THAN CABLE OR APPARATUS USED FOR THE DEMOLITION WORKS SHALL BE DISCONNECTED ARRANGEMENTS SHALL BE MADE WITH THE RELEVANT ELECTRICAL SUPPLY AUTHORITY FOR THE DISCONNECTION OF ELECTRICAL MAINS SUPPLY EXCEPT THAT WHERE PARTIAL DEMOLITION IS PROPOSED THE LICENSED ELECTRICAL CONTRACTOR SHALL SATISFY THE RELEVANT ELECTRICAL SUPPLY AUTHORITY THAT THE PORTION OF THE BUILDING TO BE DEMOLISHED HAS BEEN ISOLATED THE DEMOLISHER SHALL BE RESPONSIBLE TO CUT & SEAL ANY STORM WATER, SEWER PIPES, WATER SERVICES, GAS SERVICES & THE LIKE IN ACCORDANCE WITH RELEVANT STANDARDS & SUPPLIERS REQUIREMENTS. THE POSITION OF CAPPED SEWER & STORM WATER DRAINS, SEALED-OFF WATER SUPPLY LINES, GAS SUPPLY LINES & THE LIKE ARE TO BE CLEARLY MARKED ON THE SITE. 3-5/ 33 Nish Street, Echuca 3564 566 St Kilda Road, Melbourne 3004 admin@ecotecturedesign.com.au 03 54807884 PRIOR TO COMMENCEMENT OF WORKS, CONTRACTOR SHALL PREFORM AN ASBESTOS AUDIT OF PROPOSED WORKS. IF ANY ADDITIONAL ASBESTOS IS LOCATED WITHIN THE BUILDING WORKS, THE CONTRACTOR SHALL NOTIFY THE ADMINISTRATOR IMMEDIATELY. ALL ASBESTOS IDENTIFICTION IS THE RESPONSIBILITY OF THE CONTRACTOR. CONTRACTOR MUST PREPAIR AN ASBESTOS REPORT OUTLINING ALL LOCATIONS OF ASBESTOS DETECTED IN PREMISES. ANY REMOVAL OR REPAIR OF ASBESTOS CONTAINING MATERIALS MUST BE CARRIED OUT BY A LICENSED ASBESTOS REMOVALIST. A LIST OF LICENSED REMOVALISTS IS AVAILABLE AT THE WORKCOVER WEB SITE ON www.worksafe.vic.gov.au COOL ROOM COOLROOM OR FREEZER MUST BE ABLE TO BE OPENED BY HAND FROM THE INSIDE WITHOUT A KEY INTERNAL LIGHTING MUST BE CONTROLLED BY A SWITCH LOCATED NEXT TO ENTRANCE DOOR AN INDICATOR LAMP MUST BE POSITIONED OUTSIDE THE COOLROOM OR FREEZER & BE OPERATED WITH INTERNAL LIGHT SWITCH AN ALARM MUST BE FITTED TO COOLROOM & FREZZER TO ALLOW IT TO BE CONTROLLED FROM INSIDE, SOUNDING DEVICE MUST BE LOCATED OUTSIDE COOLROOM / FREZZER & MUST ACHIEVE A SOUND PRESSURE OF 90dB(A) WHEN MEASURED 3m FROM THE SOUNDING DEVICE ALL TO BE IN ACCORDANCE WITH BCA SECTION G1.2 TERMITE PROTECTION DEMOLISHED MATERIAL SHALL NOT BE SO PILED OR STACKED THAT IT WILL ENDANGER WORKMEN OR OTHER PERSONS & SHALL BE REMOVED AS SOON AS PRACTICABLE FROM THE SITE. No. ASBESTOS ALL PAVING TO BE GRADED AWAY FROM BUILDING ON MIN. 1:50 FALL IN ACCORDANCE WITH THE BCA ALL GROUND SURFACES SHALL BE GRADED AWAY FROM PATHWAYS ON 1:40 MAX FALL -REFER TO DETAIL ALL NATURAL GROUND SURFACES SHALL BE GRADED AWAY FROM BUILDING ON MIN. 1:20 FALL Description WHERE THE BUILDING (EXCLUDES A DETACHED CLASS 10) IS LOCATED IN A TERMITE PRONE AREA, THE AREA TO UNDERSIDE OF BUILDING AND PERIMETER IS TO BE TREATED AGAINST TERMITE ATTACK. A TERMITE BARRIER OR COMBINATION OF BARRIERS MUST BE INSTALLED IN ACCORDANCE WITH AS 3660.1. THE AREA BENEATH THE SUSPENDED FLOOR MUST BE VENTILATED IN ACCORDANCE WITH THE BCA & INSPECTED IN ACCORDANCE WITH AS 3660.1. ALL TIMBER COMPLETELY OR PARTICALLY PROTECTED FROM WATHER TO BE H2 TREATED ALL TIMBER OUTSIDE AND ABOVE GROUND SHALL BE H3 TREATED. ALL TIMBER THAT IS NON-STRUCTURAL THAT IS IN CONTACT WITH GROUND OR WATER SHALL BE H4 TREATED. STORM WATER 90mmø CLASS 6 UPVC STORMWATER LINE LAID TO A MINIMUM GRADE OF 1:100 & CONNECTED TO THE LEGAL POINT OF STORMWATER DISCHARGE. PROVIDE INSPECTION OPENINGS AT 9000mm C/C & AT EACH CHANGE OF DIRECTION THE COVER TO UNDERGROUND STORM WATER DRAINS SHALL BE NOT LESS THAN - 100mm UNDER SOIL - 50mm UNDER PAVED OR CONCRETE AREAS - 100mm UNDER UNREINFORCED CONC. OR PAVED DRIVEWAYS - 75mm UNDER REINFORCED CONC. DRIVEWAYS Date ALTERATIONS & ADDITION TO DUMOSA & TOWANINNIE PUBLIC HALL PIONEER SETTLEMENT TENDER ISSUE \\WIN7-PC\Users\Public\Documents\Drawings\2014-0044 - Dumosa Hall\WD01A.rvt MATERIALS REMOVED OR DISPLACED FROM THE BUILDING SHALL NOT BE PLACED IN ANY STREET, ROAD OR RIGHT OF WAY & BEFORE COMMENCING WHERE REQUIRED SHALL BE KEPT SPRAYED WITH WATER SO AS TO PREVENT ANY NUISANCE FROM DUST WORKING DRAWINGS Project number Date Drawn by 2014-0044 NOVEMBER 2014 Scale ABN. 58 918 283 483 WD02 MCL Sheet WD02 Of RBP: DP-AD 18414 WD14 12/11/2014 9:16:01 AM ALL MATERIALS & WORK PRACTICES SHALL COMPLY WITH BUT NOT LIMITED TO, THE BUILDING REGULATIONS 2006, THE BUILDING CODE OF AUSTRALIA & ALL RELEVANT CURRENT AUSTRALIAN STANDARDS (AS AMENDED) REFERRED TO THEREIN. THESE SPECIFICATIONS SPECIFY ONLY THE MINIMUM STANDARD OF WORK FOR THE DEMOLITION WORKS ON RESIDENTIAL PROJECTS & ALL WORKMANSHIP & PRECAUTIONS SHALL BE TO THE BEST TRADE PRACTICE. TEMPORARY CARRIAGE SHED ENTRANCE BUILDING DUMOSA HALL C HO OUR US T E SCHOOL MACHINERY SHED FIRE STATION BU I LD IN G OF FIC E WOOL BARGE VEGA BLACKSMITHS PIONEER SETTLEMENT AL ER E N R GE TO S RE ES PR IN T IN G I HO RON US E PHOTOGRAPHIC PARLOUR AGRICULTURAL IMPLEMENTS STEAM MACHINE WORKSHOP POTTERY & SIGN WRITER / COACH PAINTER AREA OF WORKS COACH HOUSE POST OFFICE STABLES SHEARING SHED CHURCH IV E KEATS COTTAGE Y TOWANINIE HOMESTEAD R U M RIVERSDALE HOMESTEAD LI T T L E L IT T L E M U R R A Y R IV E R S W EQX OT E RO ABL ST TENDER ISSUE LOCALITY PLAN SCALE: 1 : 1000 No. 3-5/ 33 Nish Street, Echuca 3564 566 St Kilda Road, Melbourne 3004 admin@ecotecturedesign.com.au 03 54807884 Description Date ALTERATIONS & ADDITION TO DUMOSA & TOWANINNIE PUBLIC HALL PIONEER SETTLEMENT WORKING DRAWINGS Project number Date Drawn by Scale ABN. 58 918 283 483 2014-0044 NOVEMBER 2014 WD03 MCL 1 : 1000 RBP: DP-AD 18414 Sheet WD03 Of WD14 12/11/2014 9:16:02 AM POND \\WIN7-PC\Users\Public\Documents\Drawings\2014-0044 - Dumosa Hall\WD01A.rvt R MUD-BRICK KITCHEN R LE LOWER MURRAY INN SCHOOL R L T IT U Y A HALF CELLAR A M R R NK BA CS NI E HA UT EC IT M ST & R IN E ER AK DL M D S C NI SA ES O E RN AS G M LOD HA IV R SPOONS RESTAURANT BUILDING R E SEWER PIT RELOCATED GAS CYLINDER & HWS ASPHALT FOOTPATH LIGHT POLE EXISTING FENCE TGSI RAMP 1:14 RAMP EXISTING TREES GAS HWS DECK AC EXDP RELOCATED HC EXISTING HALL INSTALL NEW STEEL FRAMED TIMBER SLATED SLIDING GATE & FENCING TO PROPRIETORS REQUIREMENTS (BY OTHERS) DP EXISTING GENERATOR DP NEW GUTTERS & DOWNPIPES DISCHARGING INTO EXISTING LEGAL POINT OF DISCHARGE WITH LOCAL AUTHORITIES REQUIREMENTS AC AC EXDP PROPOSED ADDITION FHR EXDP MDB TGSI DECK RAMP 1:14 HC 1800mm HIGH TIMBER SCREEN TO MATCH EXISTING FENCE PROFILE (BY OTHERS) DP VERANDAH STRUCTURE SHOWN AS DASHED TGSI GRAVEL PEDESTRIAN ACCESS (BY OTHERS) EXISTING FIRE STATION GRASSED AREA GRASSED AREA (BY OTHERS) (BY OTHERS) APPROX LOCATION OF EXISTING PIT (LPOD) BRICK EDGING TO GRASS AREAS (BY OTHERS) GRAVEL VEHICLE ACCESS S W EQX EXISTING BLACKSMITHS PART SITE PLAN TENDER ISSUE SCALE: 1 : 200 No. A 3-5/ 33 Nish Street, Echuca 3564 566 St Kilda Road, Melbourne 3004 admin@ecotecturedesign.com.au 03 54807884 Description FENCING BY OTHERS APPROX LOCATION OF LPOD Date 10/11/2014 ALTERATIONS & ADDITION TO DUMOSA & TOWANINNIE PUBLIC HALL PIONEER SETTLEMENT \\WIN7-PC\Users\Public\Documents\Drawings\2014-0044 - Dumosa Hall\WD01A.rvt LANDING WORKING DRAWINGS Project number Date Drawn by Scale ABN. 58 918 283 483 2014-0044 NOVEMBER 2014 WD04A MCL 1 : 200 RBP: DP-AD 18414 Sheet WD04AOf WD14 12/11/2014 9:16:04 AM TGSI EXISTING STABLES PROPOSED ADDITION EXISTING FENCE LIGHT POLE REMOVE SECTION OF EXISTING FENCE AS INDICATED (BY OTHERS) REMOVE SECTION OF WALL FOR NEW DOOR AS INDICATED 5880 REMOVE EXISTING WINDOWS & WALL AS INDICATED FOR NEW MULTISTACK DOOR REMOVE EXISTING FENCING & GATES AS INDICATED AC HC AC REMOVE EXISTING TREE BRANCHES AS REQUIRED TO ACCOMMODATE PROPOSED BUILDING (BY OTHERS) REMOVE EXISTING WINDOW & WALL AS INDICATED FOR NEW DOOR 1000 5600 HWS RELOCATE EXISTING GAS CYLINDER, HWS & HC - CUT & SEAL & REMOVE SERVICES AS REQUIRED GAS CYLINDER REMOVE EXISTING RAMP, LANDING & STEPS STAGE WALL & STAGE TO BE REMOVED AS INDICATED REMOVE EXISTING DOORS AS INDICATED FOR NEW WINDOW STAGE STAIRS TO BE REMOVED AS INDICATED DEMOLITION PLAN LEGEND REMOVE EXISTING WINDOWS & WALL AS INDICATED FOR NEW MULTISTACK DOOR ITEM TO BE REMOVED W EQX S EXISTING GENERATOR AC AC AC 5600 REMOVE EXISTING TIMBER STEPS & FLOOR AS INDICATED FHR REMOVE EXISTING WINDOW & WALL AS INDICATED FOR NEW DOOR MOTOR GARAGE TO BE DEMOLISHED SHOWN DASHED (BY OTHERS) DEMOLITION PLAN TENDER ISSUE SCALE: 1 : 100 No. A 3-5/ 33 Nish Street, Echuca 3564 566 St Kilda Road, Melbourne 3004 admin@ecotecturedesign.com.au 03 54807884 MDB Description FENCING BY OTHERS Date 10/11/2014 ALTERATIONS & ADDITION TO DUMOSA & TOWANINNIE PUBLIC HALL PIONEER SETTLEMENT WORKING DRAWINGS Project number Date Drawn by Scale ABN. 58 918 283 483 2014-0044 NOVEMBER 2014 WD05A MCL 1 : 100 RBP: DP-AD 18414 Sheet WD05AOf WD14 12/11/2014 9:16:05 AM AC EXIST WALLS TO REMAIN \\WIN7-PC\Users\Public\Documents\Drawings\2014-0044 - Dumosa Hall\WD01A.rvt WALLS TO BE REMOVED 19840 380 4590 DECK AC COOLROOM, MOTOR & DISPLAY DOORS ARE TO BE SUPPLIED ROOF OVER SHOWN DASHED 90 1290 100 LANDING 4300 100 DECK TGSI D 02 AC D 01 L.1. C.1. AC COOL ROOM P.1. P.1. P.1. 2415 P.1. 50 11 REDGUM TIMBER STEPS & STAINLESS STEEL HANDRAILS RB-1 5690 P.1. P.1. 2415 P.1. 1005 DECK 3700 EX WALL 9260 VERANDAH STRUCTURE OVER TO ENGINEERS DESIGN & DETAIL SHOWN AS DASHED 960 DECK DECKING TO BOX AROUND EXISTING TREES AS INDICATED - TREE NOT SHOWN FOR CLARITY TGSI KITCHEN EX WALL 2700 90 12480 EX WALL TENDER ISSUE 24430 Description RAMP AT LEAST 1200 WIDE NEW RAMP STAINLESS STEEL HANDRAILS Date 10/11/2014 ALTERATIONS & ADDITION TO DUMOSA & TOWANINNIE PUBLIC HALL PIONEER SETTLEMENT W EQX 2420 S 90 OVERALL 3-5/ 33 Nish Street, Echuca 3564 566 St Kilda Road, Melbourne 3004 admin@ecotecturedesign.com.au 03 54807884 EX WALL P.1. 15270 4180 SCALE: 1 : 100 A 1800mm HIGH TIMBER SCREEN FENCE 2460 STORAGE No. FHR MDB 15780 RAMP 6685 C.1. INSTALL NEW DOOR AS INDICATED 1200 EX WALL 6390 FLOOR PLAN D 03 WP-1 RAMP 1750 ELECTRICAL CONTRACTOR MUST INSTALL AN INDICATOR LAMP OUTSIDE THE COOLROOM WHICH IS OPERATED IN COMBINATION WITH THE LIGHT INSIDE THE COOLROOM D 04 D 05 LINTEL OVER SUPPORTING ROOF TRUSSES TO ENGINEERS DESIGN & DETAIL \\WIN7-PC\Users\Public\Documents\Drawings\2014-0044 - Dumosa Hall\WD01A.rvt 8 5 COOLROOM MUST BE EQUIPPED WITH AN ALARM MOUNTED OUTSIDE OF COOLROOM & OPERATED FROM THE INSIDE. THE ALARM MUST REACH 90dB(A) MEASURED 3m FROM THE SOUNDING DEVICE IN STRICT ACCORDANCE WITH THE NCC INSTALL NEW 6 PANEL MULTISTACK DOOR AS INDICATED - TRACKS RECESSED IN FLOOR TO ENSURE SMOOTH TRANSITION OVER THRESHOLD AC HC 1:14 MAX GRADIENT STORAGE P.1. 2455 DECK 3045 JOINERY TO PROPRIETORS REQUIREMENTS BSN WORKING DRAWINGS Project number Date Drawn by Scale ABN. 58 918 283 483 2014-0044 NOVEMBER 2014 WD06A MCL 1 : 100 RBP: DP-AD 18414 Sheet WD06AOf WD14 12/11/2014 9:16:07 AM D.P. REF EX WALL REF INSTALL NEW TIMBER FIXED WINDOW MATCHING EXISTING PROFILE - INSTALLED & FLASHED IN ACCORDANCE WITH MANUFACTURERS INSTRUCTION & THE NCC DE C K EXISTING HC RELOCATED AS INDICATED L.1. 1200 3 9 DE C K 7 D 06 4300 D 07 90 LANDING 5040 1 STORAGE SSB INSTALL NEW 6 PANEL MULTISTACK DOOR AS INDICATED - TRACKS RECESSED IN FLOOR TO ENSURE SMOOTH TRANSITION OVER THRESHOLD 900 90 1495 CT 2455 EX WALL SSB 4 LINTEL OVER SUPPORTING ROOF TRUSSES TO ENGINEERS DESIGN & DETAIL INSTALL NEW SERVICE COUNTER AS INDICATED TO PROPRIETORS REQUIREMENTS P.1. SSB 6 EXISTING BEAM D 10 C.1. D 11 3045 DECK EXISTING BEAM RAMP DW MIN 1000mm HIGH BALUSTRADE TO PERIMETER OF DECK - REFER TO DETAIL 15420 W.01 W. 01 RAMP TGSI REDGUM TIMBER STEPS & STAINLESS STEEL HANDRAILS C.1. D 09 2 10 6145 AC JOINERY TO PROPRIETORS REQUIREMENTS DECKING TO BOX AROUND EXISTING TREES AS INDICATED - TREE NOT SHOWN FOR CLARITY EXISTING BEAM MIN. 1500 DECK 6175 DECK EX WALL 7350 W.02 W.02 SNK.1 D 08 WD10A 6810 DRY STORE HWS EX WALL TGSI RAMP 1:14 MAX GRADIENT AC EX WALL COOL ROOM 15270 MIN. 1500 WD09A BB 90 2360 EX WALL EXISTING GAS CYLINDER & HWS RELOCATED AS INDICATED D.P. 2490 5500 2490 4180 AA GAS 90 3720 BOUNDRY LINE - ENSURE HANDRAIL DOES NOT ENCROACH FOOTPATH 90 100 2800 100 90 6990 OVERALL 1810 RAMP 1890 1890 50 1200 DRY STORE 9480 EXISTING EX WALL EXISTING BEAM 4500 TGSI ADDITION 90 LANDING BOUNDRY LINE - EDGE OF ASHPHALT FOOTPATH CORRUGATED ROOF SHEETING FIXED OVER SUITABLE ROOF BATTENS & OUTRIGGERS TO ENGINEERS DESIGN & DETAIL NEW WEATHERBOARDS TO MATCH EXISTING PROFILE AS INDICATED INSTALLED IN ACCORDANCE WITH MANUFACTURERS INSTRUCTIONS & THE NCC - APPLY PAINTED FINISH TO PROPRIETORS REQUIREMENTS PREP & MAKE GOOD EXISTING WEATHERBOARDS APPLY PAINTED FINISH TO PROPRIETORS REQUIREMENTS CORRUGATED ROOF SHEETING FIXED TO EXPOSED TIMBER RAFTERS TO ENGINEERS DESIGN & DETAIL - APPLY PAINTED FINISH TO PROPRIETORS REQUIREMENTS 7.5° 3780.00 ECL 3300 NCL 3300.00 FL RWH RECYCLED "SPOTTED GUM" TIMBER WALL CLADDING FROM NULLABOR TIMBER WITH CUTEK FINISH INSTALLED IN ACCORDANCE WITH MANUFACTURERS INSTRUCTIONS & THE NCC FHR D.P. D 05 D 02 1800mm HIGH REDGUM TIMBER SCREEN D 01 0.00 D.P. 1800mm HIGH TIMBER SCREEN TO MATCH EXISTING FENCE PROFILE (BY OTHERS) D.P. DURAGEL ADJUSTABLE STEEL STUMPS, BEARERS & JOISTS TO ENGINEERS DESIGN & DETAIL REDGUM BALUSTER & TOP RAIL AROUND PERIMETER OF DECK - REFER TO DETAIL REDGUM TIMBER STEPS & STAINLESS STEEL HANDRAILS TIMBER FRAMED MULTI STACK DOORS WITH MATCHING FLYSCREENS - INSTALLED & FLASHED IN ACCORDANCE WITH MANUFACTURERS INSTRUCTIONS & THE NCC EAST ELEVATION RECYCLED "SPOTTED GUM" TIMBER WALL CLADDING FROM NULLABOR TIMBER WITH CUTEK FINISH INSTALLED IN ACCORDANCE WITH MANUFACTURERS INSTRUCTIONS & THE NCC EXISTING SIGN TO BE REJUVENATED & REMOUNTED 7.5° EX. FHR FL REDGUM BALUSTER & TOP RAIL AROUND PERIMETER OF DECK - REFER TO DETAIL EX. W.01 W.01 0.00 D.P. DURAGEL ADJUSTABLE STEEL STUMPS, BEARERS & JOISTS TO ENGINEERS DESIGN & DETAIL NORTH ELEVATION 1800mm HIGH REDGUM TIMBER SCREEN SCALE: 1 : 100 No. A 3-5/ 33 Nish Street, Echuca 3564 566 St Kilda Road, Melbourne 3004 admin@ecotecturedesign.com.au 03 54807884 NEW TIMBER FRAMED FIXED WINDOW INSTALLED & FLASHED IN ACCORDANCE WITH MANUFACTURERS INSTRUCTIONS & THE NCC Description FENCING BY OTHERS Date 10/11/2014 ALTERATIONS & ADDITION TO DUMOSA & TOWANINNIE PUBLIC HALL PIONEER SETTLEMENT PREP & MAKE GOOD EXISTING WEATHERBOARDS APPLY PAINTED FINISH TO PROPRIETORS REQUIREMENTS TENDER ISSUE WORKING DRAWINGS Project number Date Drawn by Scale ABN. 58 918 283 483 2014-0044 NOVEMBER 2014 WD07A MCL 1 : 100 RBP: DP-AD 18414 Sheet WD07AOf WD14 12/11/2014 9:16:09 AM ECL 3780.00 CORRUGATED ROOF SHEETING FIXED TO EXPOSED TIMBER RAFTERS TO ENGINEERS DESIGN & DETAIL - APPLY PAINTED FINISH TO PROPRIETORS REQUIREMENTS \\WIN7-PC\Users\Public\Documents\Drawings\2014-0044 - Dumosa Hall\WD01A.rvt SCALE: 1 : 100 NEW WEATHERBOARDS TO MATCH EXISTING PROFILE AS INDICATED INSTALLED IN ACCORDANCE WITH MANUFACTURERS INSTRUCTIONS & THE NCC - APPLY PAINTED FINISH TO PROPRIETORS REQUIREMENTS TIMBER FRAMED MULTI STACK DOORS WITH MATCHING FLYSCREENS - INSTALLED & FLASHED IN ACCORDANCE WITH MANUFACTURERS INSTRUCTIONS & THE NCC CORRUGATED ROOF SHEETING FIXED OVER SUITABLE ROOF BATTENS & OUTRIGGERS TO ENGINEERS DESIGN & DETAIL 7.5° BOX GUTTER OVERFLOW ECL 3780.00 3300.00 NCL W.02 W.02 REDGUM BALUSTER & TOP RAIL AROUND PERIMETER OF DECK - REFER TO DETAIL FL RECYCLED "SPOTTED GUM" TIMBER WALL CLADDING FROM NULLABOR TIMBER WITH CUTEK FINISH INSTALLED IN ACCORDANCE WITH MANUFACTURERS INSTRUCTIONS & THE NCC TIMBER FRAMED BI-FOLD WINDOW TO COUNTER INSTALLED & FLASHED IN ACCORDANCE WITH MANUFACTURERS INSTRUCTIONS & THE NCC EX. D 11 0.00 DURAGEL ADJUSTABLE STEEL STUMPS, BEARERS & JOISTS TO ENGINEERS DESIGN & DETAIL REDGUM TIMBER STEPS & STAINLESS STEEL HANDRAILS PREP & MAKE GOOD EXISTING WEATHERBOARDS APPLY PAINTED FINISH TO PROPRIETORS REQUIREMENTS RECYCLED "SPOTTED GUM" TIMBER WALL CLADDING FROM NULLABOR TIMBER WITH CUTEK FINISH INSTALLED IN ACCORDANCE WITH MANUFACTURERS INSTRUCTIONS & THE NCC CORRUGATED ROOF SHEETING FIXED OVER SUITABLE ROOF BATTENS & OUTRIGGERS TO ENGINEERS DESIGN & DETAIL CORRUGATED ROOF SHEETING FIXED TO EXPOSED TIMBER RAFTERS TO ENGINEERS DESIGN & DETAIL - APPLY PAINTED FINISH TO PROPRIETORS REQUIREMENTS ECL 3780.00 7.5° NCL 3300.00 RWH REDGUM BALUSTER & TOP RAIL AROUND PERIMETER OF DECK - REFER TO DETAIL FL D 08 D 07 D.P. 0.00 1800mm HIGH TIMBER SCREEN TO MATCH EXISTING FENCE PROFILE (BY OTHERS) SOUTH ELEVATION NEW WEATHERBOARDS TO MATCH EXISTING PROFILE AS INDICATED INSTALLED IN ACCORDANCE WITH MANUFACTURERS INSTRUCTIONS & THE NCC - APPLY PAINTED FINISH TO PROPRIETORS REQUIREMENTS DURAGEL ADJUSTABLE STEEL STUMPS, BEARERS & JOISTS TO ENGINEERS DESIGN & DETAIL 1800mm HIGH REDGUM TIMBER SCREEN TENDER ISSUE SCALE: 1 : 100 No. A 3-5/ 33 Nish Street, Echuca 3564 566 St Kilda Road, Melbourne 3004 admin@ecotecturedesign.com.au 03 54807884 Description FENCING BY OTHERS Date 10/11/2014 ALTERATIONS & ADDITION TO DUMOSA & TOWANINNIE PUBLIC HALL PIONEER SETTLEMENT WORKING DRAWINGS Project number Date Drawn by Scale ABN. 58 918 283 483 2014-0044 NOVEMBER 2014 WD08A MCL 1 : 100 RBP: DP-AD 18414 Sheet WD08AOf WD14 12/11/2014 9:16:12 AM SCALE: 1 : 100 \\WIN7-PC\Users\Public\Documents\Drawings\2014-0044 - Dumosa Hall\WD01A.rvt WEST ELEVATION SELECTED CORRUGATED ROOF SHEETING WITH COLORBOND FINISH ON 7.5° PITCH OVER TIMBER OUTRIGGERS SELECTED CORRUGATED ROOF SHEETING WITH COLORBOND FINISH ON 7.5° PITCH OVER SUITABLE TIMBER BATTENS (FLUSH WITH TRUSS) @ 900 CTRS PROPRIETARY TREATED TIMBER TRUSS @ 900 MAX CTRS. FIXED, BRACED & INSTALLED IN ACCORDANCE WITH MANUFACTURERS INSTRUCTIONS TENDER ISSUE 01 WD09A NCL 3300.00 TIMBER OUTRIGGERS @ MAX 900 CTRS TO ENGINEERS DESIGN & DETAIL INSTALL COOL ROOM 2800W x 4300L x 2400H IN ACCORDANCE WITH MANUFACTURERS INSTRUCTIONS & THE NCC 3 INSTALL 100mm HIGH DENSITY PIR PANELS TO FLOOR IN ACCORDANCE WITH MANUFACTURERS INSTRUCTIONS & THE NCC D 08 RECYCLED "SPOTTED GUM" TIMBER CLADDING FROM NULLABOR TIMBER WITH CUTEK FINISH INSTALLED IN ACCORDANCE WITH MANUFACTURERS INSTRUCTIONS & THE NCC 2 JOINERY TO PROPRIETORS REQUIREMENTS 0.00 19mm PARTICLE BOARD INSTALLED IN ACCORDANCE WITH MANUFACTURERS INSTRUCTIONS & THE NCC SECTION AA CONC. FOOTINGS TO ENGINEERS DESIGN & DETAIL SCALE: 1 : 50 SELECTED CORRUGATED ROOF SHEETING WITH COLORBOND FINISH ON 7.5° PITCH OVER SUITABLE TIMBER BATTENS (FLUSH WITH TRUSS) @ 900 CTRS RECYCLED 'SPOTTED GUM' WALL CLADDING FROM NULLABOR TIMBER WITH CUTEK FINISH INSTALLED IN ACCORDANCE WITH MANUFACTURERS INSTRUCTIONS & THE NCC BRADFORD ENVIROSEAL PROCTORWRAP BLACK LABEL BREATHABLE SARKING FLASH AS REQUIRED PROVIDE 6mm FC SHEET TO TRUSS & LINE WITH CONTINUOUS GALVANISED SHEETING TREATED TIMBER TRUSS @ MAX 900 CTRS FIXED, BRACED & INSTALLED TO MANUFACTURERS INSTRUCTIONS WIND MOULD FLASH AS REQUIRED TO EXISTING ROOF STRUCTURE TIMBER OUTRIGGERS @ MAX 900 CTRS TO ENGINEERS DESIGN & DETAIL 150 CEILING TOP HAT BATTENS TREATED TIMBER TRUSS @ MAX 900 CTRS FIXED, BRACED & INSTALLED TO MANUFACTURERS INSTRUCTIONS STEEL COLORBOND GUTTERING & TIMBER FASCIA INSTALLED IN ACCORDANCE WITH MANUFACTURERS INSTRUCTIONS RECYCLED 'SPOTTED GUM' WALL CLADDING FROM NULLABOR TIMBER WITH CUTEK FINISH INSTALLED IN ACCORDANCE WITH MANUFACTURERS INSTRUCTIONS & THE NCC CEILING TOP HAT BATTENS EXISTING BUILDING PARALLEL CHORDED TRUSS INSTALLED IN ACCORDANCE WITH MANUFACTURERS INSTRUCTIONS 350 x 150 DEEP GALVANISED BOX GUTTER ON MIN 1:200 FALL TOWARDS RAIN WATER HEAD CORNICE MIN. 350 DETAIL 01 - OUTRIGGER DETAIL 02 - BOX GUTTER SCALE: 1 : 20 SCALE: 1 : 20 No. A 3-5/ 33 Nish Street, Echuca 3564 566 St Kilda Road, Melbourne 3004 admin@ecotecturedesign.com.au 03 54807884 Description BOX GUTTER DIMENSION Date 10/11/2014 ALTERATIONS & ADDITION TO DUMOSA & TOWANINNIE PUBLIC HALL PIONEER SETTLEMENT 90 x 45 MGP10 TIMBER TRIMMER @ MAX 900 CTRS \\WIN7-PC\Users\Public\Documents\Drawings\2014-0044 - Dumosa Hall\WD01A.rvt DURAGAL STEEL FLOORING SYSTEM IN ACCORDANCE WITH ENGINEERS DESIGN WORKING DRAWINGS Project number Date Drawn by Scale ABN. 58 918 283 483 2014-0044 NOVEMBER 2014 WD09A MCL As indicated RBP: DP-AD 18414 Sheet WD09AOf WD14 12/11/2014 9:16:14 AM FL D 07 10mm THICK PLASTERBOARD CEILING LINING FIXED TO SUITABLE STEEL TOP HAT BATTENS @450 MAX CTRS INSTALLED IN ACCORDANCE WITH MANUFACTURERS SPECIFICATIONS 2400 BRADFORD ENVIROSEAL PROCTORWRAP BLACK LABEL BREATHABLE SARKING SELECTED CORRUGATED ROOF SHEETING WITH COLORBOND FINISH ON 7.5° PITCH OVER SUITABLE TIMBER BATTENS (FLUSH WITH TRUSS) @ 900 CTRS PROPRIETARY TREATED TIMBER TRUSS @ 900 MAX CTRS. FIXED, BRACED & INSTALLED IN ACCORDANCE WITH MANUFACTURERS INSTRUCTIONS TENDER ISSUE SELECTED CORRUGATED ROOF SHEETING WITH COLORBOND FINISH ON 7.5° PITCH OVER TRUSS TOP CHORD STEEL COLORBOND GUTTERING & TIMBER FASCIA INSTALLED IN ACCORDANCE WITH MANUFACTURERS INSTRUCTIONS PREFABRICATED PARALLEL CHORD TRUSS AS PER MANUFACTURERS SPECIFICATION MIN. 350 FLASH AS REQUIRED TO EXISTING ROOF BRADFORD ENVIROSEAL 02 PROCTORWRAP BLACK WD09A LABEL BREATHABLE SARKING RECYCLED "SPOTTED GUM" TIMBER CLADDING FROM NULLABOR TIMBER WITH CUTEK FINISH INSTALLED IN ACCORDANCE WITH MANUFACTURERS INSTRUCTIONS & THE NCC 150 NCL 3300.00 EXISTING ROOF STRUCTURE 10mm THICK PLASTERBOARD CEILING LINING FIXED TO SUITABLE STEEL TOP HAT BATTENS @450 MAX CTRS INSTALLED IN ACCORDANCE WITH MANUFACTURERS SPECIFICATIONS 1 2 D 08 1800mm HIGH TIMBER SCREEN TO MATCH EXISTING FENCE PROFILE EXISTING BUILDING 4 JOINERY TO PROPRIETORS REQUIREMENTS SIZE & LOCATION OF EXISTING FOOTING ASSUMED ONLY - CONTRACTOR TO VERIFY ON SITE TO ENSURE NEW FOOTINGS DO NOT UNDERMINE EXISTING SECTION BB 240 RWH TIMBER FRAMING SCHEDULE 165 GALVANISED STEEL RAINWATER HEAD WITH GRADED BOTTOM TOP PLATE: BOTTOM PLATE: COMMON WALL STUDS 2700H: COMMON WALL STUDS 3000H: NOGGINGS: SIZE GRADE 2/35 x 90 35 x 90 90 x 35 90 x 35 35 x 90 MGP MGP MGP MGP MGP TREATED H2 H2 H2 H2 H2 10 10 10 10 10 SPAN / SPACING 160 D.P. D.P. 110mmø GALVANISED STEEL DOWN PIPE 160 110 390 @450 CTRS @450 CTRS @1350 VERTICAL CTRS 150 110 15 GALVANISED STEEL OVERFLOW POP 150 110 240 ALL BRACING REQUIREMENTS TO BE IN STRICT ACCORDANCE WITH AS 1684-2010 CONTRACTOR TO PROVIDE BRACING DETAILS WIND CLASSIFICATION: N2 MAX RLW: 3000 ROOF MASS: 40kg/m² TIMBER MEMBER 390 410 GALVANISED RAIN WATER HEAD INSTALLED & FLASHED IN ACCORDANCE WITH MANUFACTURERS INSTRUCTIONS & THE BCA SCALE: 1 : 50 15 110mmø GALVANISED STEEL OVERFLOW POP RAIN WATER HEAD SCALE: 1 : 20 No. A 3-5/ 33 Nish Street, Echuca 3564 566 St Kilda Road, Melbourne 3004 admin@ecotecturedesign.com.au 03 54807884 Description BOX GUTTER DIMENSION Date 10/11/2014 ALTERATIONS & ADDITION TO DUMOSA & TOWANINNIE PUBLIC HALL PIONEER SETTLEMENT WORKING DRAWINGS Project number Date Drawn by Scale ABN. 58 918 283 483 2014-0044 NOVEMBER 2014 WD10A MCL As indicated RBP: DP-AD 18414 Sheet WD10AOf WD14 12/11/2014 9:16:15 AM CONC. FOOTINGS TO ENGINEERS DESIGN & DETAIL 410 FL 0.00 DURAGAL STEEL FLOORING SYSTEM IN ACCORDANCE WITH ENGINEERS DESIGN \\WIN7-PC\Users\Public\Documents\Drawings\2014-0044 - Dumosa Hall\WD01A.rvt 350 x 150 DEEP GALVANISED BOX GUTTER OVER SPANDEK SHEETING WITH SUITABLE GUTTER STRAPS @ 1200 MAX CTRS ON MIN 1:200 FALL TOWARDS RAIN WATER HEAD TENDER ISSUE ELECTRICAL LEGEND SINGLE G.P.O. MOUNTED 300mm ABOVE FLOOR LEVEL GENERALLY OR @ HEIGHT AS NOTED. ALL SWITCHES ABOVE BENCHES TO BE @1100 DECKLIGHTS AROUND EXISTING TREES AS INDICATED - TREE NOT SHOWN FOR CLARITY DOUBLE G.P.O. MOUNTED 300mm ABOVE FLOOR LEVEL GENERALLY OR @ HEIGHT AS NOTED. ALL SWITCHES ABOVE BENCHES TO BE @1100 EXISTING WALLS TO REMAIN SHOWN AS SOLID BLACK W WATER PROOF DOUBLE G.P.O. MOUNTED 1000mm ABOVE FLOOR LEVEL GENERALLY OR @ HEIGHT AS NOTED. SWITCH MOUNTED AT 1000mm ABOVE FLOOR LEVEL. 2 EXISTING FIRE BLANKET TO COMPLY WITH AS 2444-2001 - REPLACE ITEM IF REQUIRED TO COMPLY FE FB G TIN S I EX G IN HT G LI TO 900mm STAINLESS STEEL CEILING FAN WITH 3 SPEED VARIABLE SWITCH. SWITCH SEPARATE FOR EACH INDEPENDENT USE (CLIPSAL 4HS900) IN MA E R CEILING MOUNTED CIRCULAR T9 40w FLUORESCENT LIGHT FITTING. COMPLETE WITH ACRYLIC DIFFUSER B2 BALLAST & LAMPS (CLIPSAL CF40) CLIPSAL 2 x 28 WATT SURFACE MOUNTED WEATHERPROOF BATTENS TYPOON T5 LAMPS COMPLETE WITH LAMPS, LAMP HOLDERS, DIFFUSERS & STARTERS & TIME SWITCH (WP214) SWITCHED WTIH INDICATOR LAMP MDB EXISTING METER DISTRIBUTION BOARD FE 2 WALL LIGHT EXTERIOR TWIN LAMP CFL 304 GRADE STAINLESS STEEL IP44 ( CLIPSAL WDL722) FE MDB LED 15 LIGHT 240V SQUARE DECKLIGHT IN MARINE GRADE STAINLESS STEEL ( BEACON SKU# 220841 ) FHR ELECTRICAL CONTRACTOR MUST INSTALL AN INDICATOR LAMP OUTSIDE THE COOL ROOM WHICH IS OPERATED IN COMBINATION WITH THE LIGHT INSIDE THE COOL ROOM 3 x 3 SPEED VARIABLE SWITCH FOR FANS NUD COLLECTION LIGHT CLASSIC BLACK CABLE WITH BLACK FITTING WITH 60W GLOBE EXISTING FIRE EXTINGUISERS TO COMPLY WITH AS 2444-2001 - REPLACE ITEM IF REQUIRED TO COMPLY DECKLIGHTS AROUND EXISTING TREES AS INDICATED - TREE NOT SHOWN FOR CLARITY FIRE FIGHTING EQUIPMENT S W EQX FE LIGHTING & GPO PLAN SCALE: 1 : 100 No. 3-5/ 33 Nish Street, Echuca 3564 566 St Kilda Road, Melbourne 3004 admin@ecotecturedesign.com.au 03 54807884 ENERGY EFFICIENCY LIGHTING THESE DRAWINGS SHALL BE READ IN CONJUNCTION WITH THE BCA SECTION J ENERGY RATING REPORT & SHALL BE CONSTRUCTION IN ACCORDANCE WITH THE STAMPED PLANS WITHOUT ALTERATION. CONTRACTOR TO REFER TO THE BCA SECTION J REPORT TO ENSURE COMPLIANCE WITH THE INSTALLATION OF ALL LIGHTING ALL LIGHTING SHALL BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS, BCA & RELEVANT AUSTRALIAN STANDARDS Description Date ALTERATIONS & ADDITION TO DUMOSA & TOWANINNIE PUBLIC HALL PIONEER SETTLEMENT FB EXISTING FIRE EXTINGUISHER INSTALLED AT 1200 ABOVE FFL (SIGNAGE OVER AT 2000 ABOVE FFL) IN STRICT ACCORDANCE WITH THE NCC & AS 2444-2001 EXISTING FIRE BLANKET INSTALLED IN STRICT ACCORDANCE WITH THE BCA & AS 2444-2001 EXISTING FIRE HOSE REEL INSTALLED IN STRICT ACCORDANCE WITH THE BCA & AS 2444-2001 ALL FIRE SERVICE EQUIPMENT TO BE SIGNED IN ACCORDANCE WITH AS 2444-2001 REFER TO SPECIFICATIONS FOR SIGNAGE DETAILS & LOCATIONS \\WIN7-PC\Users\Public\Documents\Drawings\2014-0044 - Dumosa Hall\WD01A.rvt WEATHER PROOF EXTERIOR WALL MOUNTED FLOODLIGHT COMPLETE WITH MOTION & DAYLIGHT SENSORS ( CLIPSAL 754HF1/180/300) 2 ELECTRICAL CONTRACTOR SHALL INSTALL NEW INDICATOR LAMP OUTSIDE THE COOLROOM WHICH IS OPERATED IN COMBINATION WITH THE LIGHT INSIDE THE COOLROOM WATER PROOF SWITCH MOUNTED AT 1000mm ABOVE FLOOR LEVEL WORKING DRAWINGS Project number Date Drawn by Scale ABN. 58 918 283 483 2014-0044 NOVEMBER 2014 WD11 MCL As indicated RBP: DP-AD 18414 Sheet WD11 Of WD14 12/11/2014 9:16:17 AM W EX I ST ING W L IG HT ING TO RE MA IN W 2 WAY SWITCH MOUNTED AT 1000mm ABOVE FLOOR LEVEL. STAIR NOTES: STAINLESS STEEL UPRIGHT ALL STEP SIZES & DETAILS IN STRICT ACCORDANCE WITH PART 3.9.1 OF THE NCC 50 x 50 RED GUM POST SECURELY FIXED AND RIGID STEP SIZES (OTHER THAN FOR SPIRAL STAIRS) TO BE: RISERS (R) 190mm MAX & 115mm MIN. GOING (G) 355mm MAXIMUM & 250mm MINIMUM FOR PUBLIC STAIRWAYS & 355mm MAXIMUM & 240mm MINIMUM FOR PRIVATE STAIRWAYS 2R + 1G = 700mm MAXIMUM & 550mm MINIMUM CONSTRUCTED WITH A LESS THAN 125mm GAP TO OPEN TREADS 20mm HARDWOOD DECKING WITH NON-SKID FINISH DECKING MUST BE FLUSH AS PER AS 1428.1-2009 150 75mm WIDE REDGUM TIMBER FIXED TO POSTS TO ACT AS KERBS IN STRICT ACCORDANCE WITH AS 1428.1-2009 STAINLESS STEEL HANDRAIL TO HAVE NO OBSTRUCTION TO THE PASSAGE OF A HAND ALONG THE RAIL RED GUM LINING BOARDS DURAGAL STEEL FLOORING SYSTEM IN ACCORDANCE WITH ENGINEERS DESIGN & DETAIL MIN. 1200 CLEAR PATH OF TRAVEL RAMP DETAIL 75mm WIDE REDGUM TIMBER FIXED TO POSTS TO ACT AS KERBS IN STRICT ACCORDANCE WITH AS 1428.1-2009 SCALE: 1 : 20 75 CONCRETE BASE TO ENGINEERS DESIGN & DETAIL 150 150 100 MIN 150mm GROUND CLEARANCE AS PER NCC 7725 MIN DURAGAL STEEL FLOORING SYSTEM IN ACCORDANCE WITH ENGINEERS DESIGN & DETAIL CONTINUE REDGUM KERB CROSS/AROUND LANDING WHERE POSSIBLE RAMP 1:14 MAX GRADIENT RAMP SECTION TENDER ISSUE SCALE: 1 : 20 No. A 3-5/ 33 Nish Street, Echuca 3564 566 St Kilda Road, Melbourne 3004 admin@ecotecturedesign.com.au 03 54807884 Description RAMP AT LEAST 1200 WIDE Date 10/11/2014 ALTERATIONS & ADDITION TO DUMOSA & TOWANINNIE PUBLIC HALL PIONEER SETTLEMENT WORKING DRAWINGS Project number Date Drawn by Scale ABN. 58 918 283 483 2014-0044 NOVEMBER 2014 WD12A MCL 1 : 20 RBP: DP-AD 18414 Sheet WD12AOf WD14 12/11/2014 9:16:18 AM 1500 \\WIN7-PC\Users\Public\Documents\Drawings\2014-0044 - Dumosa Hall\WD01A.rvt 150 TRANSITION 1000 MIN. 20mm HARDWOOD DECKING WITH NONSKID FINISH, DECKING MUST BE FLUSH AS PER AS 1428.1-2009 75 300 865 - 1000 EXTENDED HANDRAIL 300mm MIN PARALLEL TO SURFACE BELOW TRAFFICABLE SURFACE TO TOP OF HANDRAIL CONTINUE STAINLESS STEEL HANDRAILS CROSS/AROUND LANDING WHERE POSSIBLE TURN HANDRAIL THROUGH A TOTAL OF 180° OR RETURN FULLY TO END POST OR WALL FACE 125 x 125 F8 REDGUM POST WITH 125 x 50 F8 TOP RAIL. MIN 1000mm ABOVE FINISHED FLOOR LEVEL ABOVE FFL MIN. 1000 BALUSTRADE NOTES 75mm WIDE REDGUM TIMBER FIXED TO POSTS TO ACT AS KERBS IN STRICT ACCORDANCE WITH AS 1428.1-2009 PROVIDE BALUSTRADES WHERE CHANGE IN LEVEL EXCEEDS 1000mm ABOVE THE SURFACE BENEATH LANDINGS, RAMPS &/OR TREADS. BALUSTRADES (OTHER THAN TENSIONED WIRE BALUSTRADES) TO BE: - 1000mm MIN. ABOVE FINISHED SURFACE LEVEL OF BALCONIES, LANDINGS OR THE LIKE, & - 1000mm MIN. ABOVE FINISHED SURFACE LEVEL OF STAIR NOSING OR RAMP, & - VERTICAL WITH LESS THAN A 125mm MAX. GAP BETWEEN, & - ANY HORIZONTAL ELEMENT WITHIN THE BALUSTRADE BETWEEN 150mm & 760mm ABOVE THE FLOOR MUST NOT FACILITATE CLIMBING WHERE CHANGES IN LEVEL EXCEEDS 4000mm ABOVE THE SURFACE BENEATH LANDINGS, RAMPS &/OR TREADS TOP OF HAND RAILS TO BE MINIMUM 865mm VERTICALLY ABOVE FINISHED SURFACE OF STAIR NOSING & LANDINGS. WIRE BALUSTRADE CONSTRUCTION TO COMPLY WITH NCC 2011 VOLUME 2 PART 3.9.2.3 FOR CLASS 1 & 10 BUILDINGS & BCA 2011 VOLUME 1 PART D2.16 FOR OTHER CLASSES OF BUILDINGS. ALL BALUSTRADES TO BE IN STRICT ACCORDANCE WITH THE NCC PART 3.9.2 & AS 1428.1-2009 BALUSTRADE DETAIL SCALE: 1 : 20 TGSI NOTES TGSI SHALL BE INSTALL FOR THE FULL WIDTH OF THE PATH OF TRAVEL IN STRICT ACCORDANCE TO AS/NZS 1428.4.1-2010 TGSI SHALL BE SET BACK 300 ± 10mm FROM THE EDGE OF THE HAZARD IN STRICT ACCORDANCE TO AS/NZS 1428.4.1-2010 THE BASE SURFACE OF AN INTEGRATED TGSI SHALL BE NOT MORE THAN 3mm ABOVE THE ABUTMENT SURFACE OF THE SURROUNDING FLOOR OR GROUND SURFACE AND SHALL HAVE ALL EXPOSED EXTERNAL EDGES CHAMFERED IN STRICT ACCORDANCE TO AS/NZS 1428.4.1-2010 A TGSI SHALL BE SLIP-RESISTANT IN STRICT ACCORDANCE TO AS/NZS 1428.4.1-2010 TGSI'S SHALL BE LAID SO THAT THERE IS NO LIKELIHOOD OF THE EDGES LIFTING IN STRICT ACCORDANCE TO AS/NZS 1428.4.1-2010 TGSI SHALL HAVE LUMINANCE-CONTRAST TO THE BASE SURFACE AS FOLLOWS: i) WHERE THE INTEGRATED TGSI'S ARE OF THE SAME COLOUR AS THE UNDERLYING SURFACE - NON LESS THAN 30% ACROSS ITS ENTIRE AREA ii) WHERE DISCREET TGSI'S - NOT LESS THAN 45% iii) WHERE DISCRETE TGSI'S ARE CONSTRUCTED USING TWO COLOURS OR MATERIALS, THE RAISED SURFACE SHALL HAVE A SECTION THAT HAS 60% LUMINANCE CONTRAST FOR A DIAMETER OF 24 mm TO 25mm TESTED AS REQUIRED TENDER ISSUE SCALE: 1 : 20 No. 3-5/ 33 Nish Street, Echuca 3564 566 St Kilda Road, Melbourne 3004 admin@ecotecturedesign.com.au 03 54807884 Description Date ALTERATIONS & ADDITION TO DUMOSA & TOWANINNIE PUBLIC HALL PIONEER SETTLEMENT WORKING DRAWINGS Project number Date Drawn by Scale ABN. 58 918 283 483 2014-0044 NOVEMBER 2014 WD13 MCL 1 : 20 RBP: DP-AD 18414 Sheet WD13 Of WD14 12/11/2014 9:16:19 AM TGSI \\WIN7-PC\Users\Public\Documents\Drawings\2014-0044 - Dumosa Hall\WD01A.rvt REFER TO AS 1428.4.1-2010 FOR ALL TGSI REQUIREMENTS & SPECIFICATIONS CONTRACTOR TO ENSURE TGSI ARE INSTALLED IN STRICT ACCORDANCE WITH AS 1428.4.1-AS AMENDED WINDOW SIZES NOMINATED ARE NOMINAL ONLY. ACTUAL SIZE MAY VARY ACCORDING TO MANUFACTURER & CONTRACTOR MUST BE VERIFY ALL SIZES PRIOR TO ORDERING & CONSTRUCTING 2. CONTRACTOR MUST SEAL & FLASH ALL GAPS & CRACKS AROUND WINDOW & DOOR FRAMES PRIOR TO FIXING PLASTERBOARD IN STRICT ACCORDANCE WITH THE NCC, ENERGY RATING REQUIREMENTS & MANUFACTURERS SPECIFICATION 3. ALL WINDOWS ARE ASSUMED TO MEET AS2047 (CLAUSE 2.1.3.5) & AS4420.4 ON AIR INFILTRATION. CONTRACTOR TO CHECK BEFORE ORDERING 4. DOORS & WINDOWS TO BE HANDLED, FINISHED & INSTALLED IN ACCORDANCE WITH MANUFACTURERS SPECIFICATIONS 5. WINDOWS TO BE FITTED WITH SUITABLE MATCHING FLY SCREENS TO ALL OPEN ABLE SASHES UNLESS STATED OTHERWISE. 6. ALL OPEN ABLE WINDOWS SHALL HAVE KEYED ALIKE LOCKS 7. ALL DOOR HARDWARE/FURNITURE SHALL BE LEVER TYPE FITTED 1000mm ABOVE FFL IN ACCORDANCE WITH AS 1428.1-2009 & THE BCA 8. ALL DOOR HARDWARE & FURNITURE SHALL BE LEVER TYPE FITTED 1000mm ABOVE FFL IN ACCORDANCE WITH AS 1428.1-2009 & THE BCA 9. NO. 10. GLAZING, INCLUDING SAFETY GLAZING, SHALL BE INSTALLED TO A SIZE, TYPE & THICKNESS SO AS TO COMPLY WITH -BCA PART 3.6 FOR CLASS 1 & 10 BUILDINGS WITHIN A DESIGN WIND SPEED OF NOT MORE THAN N3, &; -NCC 2012 BCA VOL 1 PART B1.4 FOR CLASS 2 TO 9 BUILDINGS 12. ALL DOORWAYS SHALL HAVE A MIN. LUMINANCE CONTRAST OF 30% PROVIDED BETWEEN-DOOR LEAF & DOOR JAMB; -DOOR LEAF & ADJACENT WALL; -ARCHITRAVE & WALL; -DOOR LEAD & ARCHITRAVE; OR -DOOR JAMB & ADJACENT WALL MIN. WIDTH OF AREA OF LUMINANCE CONTRAST SHALL BE 50mm No. 3-5/ 33 Nish Street, Echuca 3564 566 St Kilda Road, Melbourne 3004 admin@ecotecturedesign.com.au 03 54807884 WIDTH HALL 1640 3300 3300 02 COUNTER 1500 1500 2400 NO. ALL DOORS IN A REQUIRED EXIT OR IN A PATH OF TRAVEL TO AN EXIT MUST BE READILY OPENABLE WITHOUT A KEY. THE DOOR MUST SWING IN THE DIRECTION OF EGRESS BY A SINGLE DOWNWARD ACTION OR A PUSHING ON A SINGLE DEVICE 11. SAFETY GLAZING TO BE USED IN THE FOLLOWING CASES: - WITHIN 500mm VERTICAL OF FLOOR LEVEL - WITHIN 20mm VERTICAL FROM FLOOR LEVEL &/OR WITHIN 300mm VERTICAL OF TROUGH & BATH ENCLOSURES - WITHIN 300mm HORIZONTAL FROM ALL DOORS LOCATION 01 LOCATION WIDTH DOOR SCHEDULE HEIGHT DESCRIPTION 01 HALL 5600 2400 02 HALL 870 2400 03 HALL 870 2040 04 STORAGE 1200 1980 05 STORAGE 870 2400 06 COOL ROOM 870 2040 07 COOL ROOM 870 2040 08 DRY STORE 870 2400 09 DRY STORE 870 2040 10 COUNTER 870 2400 11 HALL 5600 2400 LANDING DRY STORE 3 COOL ROOM 4 5 KITCHEN STORAGE 6 7 8 9 10 11 COUNTER SEVERY STORAGE HALL WEST DECK EAST DECK Description 7 m² NON-SKID TIMBER DECKING 17 m² COMMERCIAL GRADE VINYL ON WATERPROOF PARTICLE BOARD UNDER TIMBER FLOOR 12 m² COMMERCIAL GRADE VINYL ON 100mm COOL ROOM PANEL 29 m² EXISTING VINYL 6 m² COMMERCIAL GRADE VINYL ON WATERPROOF PARTICLE BOARD UNDER TIMBER FLOOR 8 m² EXISTING TIMBER FLOOR 11 m² EXISTING TIMBER FLOOR 4 m² EXISTING TIMBER FLOOR 116 m² EXISTING TIMBER FLOOR 48 m² NON-SKID TIMBER DECKING 86 m² NON-SKID TIMBER DECKING Date GLAZING AC BSN C.1. CT D.P. DW ECL EXDP FB FE FHR FL GAS HC HWS L.1. MDB NCL P.1. RB-1 REF RWH SNK.1 SSB TGSI U=5.5 SHGC=0.69 U=5.5 SHGC=0.69 GLAZING TIMBER FRAMED MULTI-STACK DOOR AS SELECTED U=5.5 SHGC=0.69 WITH DOOR SEAL TIMBER FRAMED SOLID CORE DOOR AS SELECTED WITH KEYED LOCK TIMBER FRAMED SOLID CORE DOOR AS SELECTED WITH KEYED LOCK HOLLOW CORE TIMBER SLIDING DOORS, COMPLETE WITH TOP TRACKS TIMBER FRAMED SOLID CORE DOOR AS SELECTED WITH KEYED LOCK COOL ROOM DOOR BY COOL ROOM MANUFACTURER. DOOR MUST BE OPENABLE FROM INSIDE WITHOUT KEY COOL ROOM DOOR BY COOL ROOM MANUFACTURER. DOOR MUST BE OPENABLE FROM INSIDE WITHOUT KEY TIMBER FRAMED SOLID CORE DOOR AS SELECTED WITH KEYED LOCK TIMBER FRAMED HOLLOW CORE CAVITY SLIDING DOOR TIMBER FRAMED HOLLOW CORE DOOR AS SELECTED TIMBER FRAMED MULTI-STACK DOOR AS SELECTED U=5.5 SHGC=0.69 WITH DOOR SEAL ROOM SCHEDULE NUMBER ROOM NAME AREA FLOOR FINISH 1 2 TIMBER FRAMED FIXED WINDOW AS SELECTED TIMBER FRAMED BI-FOLD WINDOW AS SELECTED LEGEND NAME AREA ANALYSIS AREA PROPOSED INFILL PROPOSED ADDITION EXISTING BUILDING ALTERATIONS & ADDITION TO DUMOSA & TOWANINNIE PUBLIC HALL PIONEER SETTLEMENT 6 33 178 217 WP-1 EXISTING AIR CONDITIONER UNIT EXISTING STAINLESS STEEL WALL HUNG BASIN COLUMN TO ENGINEER'S DESIGN & DETAIL EXISTING COOK TOP 90 x 90 COLORBOND DOWNPIPE DISHWASHER SPACE EXISTING CEILING LEVEL EXISTING DOWNPIPE EXISTING FIRE BLANKET EXISTING FIRE EXTINGUISHER EXISTING FIRE HOSE REEL FLOOR LEVEL EXISTING GAS CYLINDER RELOCATED EXISTING HOSE COCK RELOCATED EXISTING HOT WATER SERVICE RELOCATED LINTEL TO ENGINEER'S DESIGN & DETAIL EXISTING METER DISTRIBUTION BOARD NEW EXTENSION CEILING LEVEL 90 x 90 MGP10 POST TO ENGINEERS DESIGN ROOF BEAM TO ENGINEER'S DESIGN & DETAIL REFRIGERATOR SPACE SELECTED RAINWATER HEAD - REFER TO DETAIL EXISTING STAINLESS STEEL KITCHEN SINK STAINLESS STEEL BENCH TACTILE GROUND SURFACE INDICATORS IN ACCORDANCE WITH AS 1428.1-2001 WALING PLATE TO ENGINEERS DESIGN & DETAIL SQ'S m² m² m² m² 1 3 19 23 TENDER ISSUE \\WIN7-PC\Users\Public\Documents\Drawings\2014-0044 - Dumosa Hall\WD01A.rvt 1. WINDOW SCHEDULE HEIGHT HEAD HEIGHT DESCRIPTION WORKING DRAWINGS Project number Date Drawn by Scale ABN. 58 918 283 483 2014-0044 NOVEMBER 2014 WD14 MCL 1 : 100 RBP: DP-AD 18414 Sheet WD14 Of WD14 12/11/2014 9:16:20 AM WINDOW / DOOR NOTES