Meditech Multiparameter Monitor 12.1 inch high brightness colorful TFT Display Simultaneous display of 7 lead ECG by one frame Analysis of real time ST segment and arrhythmia Powerful data review for graphic, tabular trends and alarms review Standard parameter of ECG, NIBP, RESP, digital SPO2, TEMP and PR Maxi 96 hour graphic and tabular trend with data storage Big font, oxyCRG, Full-lead ECG interface to meet different requirement; LAN or wireless network connection as central monitoring system; Digital SPO2 enables effective examination in case of active patient, low infusion and interference from electric knife Protection against high-frequency electro tome and defibrillation effects Optional configuration: IBP, ECTO2 and recorder (printer), drug dose calculation and OXYCRG ECG Lead type: 5-lead Input: RA; LA; RL; LL; V Sweep speed: 12.5mm/s, 25mm/s, 50mm/s Accuracy: ± 1bpm or ± 1%, whichever is greater Protection: Withstand 4000VAC/50Hz voltage in isolation against electrosurgical and defibrillation S-T detection: YES, Arrhythmia analysis: YES Alarm: YES, audible and visual alarm, alarm events recallable Pulse Oximetry SPO2 Range: 1% to 99% Resolution: 1% Accuracy: 70% to 99% range: ±2%; 1% to 69% range: ±5%; Method: Dual wavelength LED NIBP (Non-invasive Blood Pressure) Technique: Oscillometric during inflation Range: Adult/Pediatric: 40 to 240 mmHg Neonate: 10 to 150 mmHg Measurement Cycle: < 40 sec. typical Automatic Measurement Cycles (Selectable): 2, 3, 5, 10, 15, 30 min; 1, 2, 4 hr STAT Mode: 5 minutes of continuous readings Max. Allowable Cuff Pressure: Adult: 300mmHg Pediatric: 240 mmHg; Neonate: 150 mmHg Resolution: 1 mmHg Transducer Accuracy: ±2 mmHg or ±2% of reading, Heart (Pulse) Rate Range: 30 to 250 bpm Accuracy: ±2 bpm or ±3%, whichever is greater Respiration Rate Rate: 2 to 120 bpm (CO2) Resolution: 1 breath/min Trends Memory: 96 hours with a NIBP reading every 5 minutes Display: tabular, graphical Interface & Display Keys: 4; membrane activated Rotary Knob: Push and rotate; 24 steps/turn Screen: 15 inch active color TFT Resolution: 800 x 480 pixels Waveforms: 3, maximum Waveform Types: CO2; Pleth; Sweep Speed: 6.25, 12.5, 25 mm/s Languages: English Capnography (CO2) (optional) Units: mmHg; kPa; % Method: Non-dispersive infrared; auto calibrating N2O Compensation: Manual; On/Off, user selectable Range: 0 to 114 mmHg; 0 to 15% Flow, Sample Rate: Sidestream; 50 ml/min Accuracy: ±2 mmHg or 5% of reading Printer (optional) Type: Thermal printer Paper Speed: 6.25, 12.5, 25 mm/sec Power Requirements Voltage: 110-240 V AC; 50 Hz Power Consumption: 8 Watts, typical Battery: 1 sealed lithium battery Battery Life: 8 hours, typical Recharge Time: 4 hours, typical Environmental Operating Temperature: 59° to 95°F (15° to 35°C) Storage Temperature: 23° to 122°F (-5° to 50°C) Operating Humidity: 15% to 90%, non-condensing Meditech Equipment Co., Ltd (Meditech Group) Address: Nanjing Road No.100, Qingdao, Shandong Province, P. R. China Tel: 86-532-85832673 85820563 Fax: 86-532-85832155 Email: sales@meditech.cn 0123 Web: www.meditech.com.cn