Bulletin AE09 TM POWERED AIRETTE Models: AC, AF Exhaust or Supply Hooded Propeller Roof Ventilators MOVING YOUR WAY Powered Airette TM Hooded Propeller Roof Ventilator Table of Contents › Powered Airette Direct Drive Series Model: AC • Static pressure up to 0.50” • Flow capacity between 1,600 - 22,600 CFM Introduction...........................................................................2 › Powered Airette Belt Drive Series Model: AC • Static pressure up to 0.50” • Flow capacity between 2,500 - 75,000 CFM Model: AF • Static pressure up to 0.50” • Flow capacity between 2,900 - 47,650 CFM Direct Drive & Belt Drive Dimensional Data.........................6 Features & Benefits..............................................................3 Options and Accessories......................................................4 Direct Drive & Belt Drive Performance Data........................8 Engineering Specifications...................................................10 Limited Warranty..................................................................IBC › UL and CSA Certification PennBarry Powered Airettes carry the UL label, UL 705. PennBarry Powered Airettes are also certified by the Canadian Standard Association. ©PENNBARRY 2008 PennBarry reserves the right to make changes at any time, without notice, to models, construction, specifications, options, availability, etc. This bulletin illustrates the appearance of PennBarry products at the time of publication. To view the latest updates, visit PennBarry at www.pennbarry.com. WWW.PENNBARRY.COM PENNBARRY 1 Introduction Powered Airette Hooded Propeller Roof Ventilator TM Introduction Hooded Propeller Roof Ventilators › PennBarry Powered Airette The PennBarry Powered Airette has been job-proven in countless installations throughout the world. Architects appreciate the low silhouette and crisp, clean contour. Engineers consider the Powered Airette’s versatility and efficiency as their answer to many ventilation problems. PennBarry Powered Airettes can be used as an efficient power roof exhauster to remove hot, humid, foul air or can be arranged to supply fresh, cooler outside air. Installation is quick and easy on existing or new construction. This unit is shipped as a complete package. A properly framed roof opening and an electrical connection are all that are required. Total access to all moving parts for maintenance and inspection is attained by raising the hinged hood. Pulley sizes can be easily changed on the job to adjust air volumes if necessary. The Powered Airette is a solid, compact unit. It is completely self-contained. The housing is low and unobtrusive but not too low or too close to hot or wet roof surfaces. All components are within the housing. They do not intrude nor protrude below the roof line. The Powered Airette is not just another panel fan with a sheet metal hood. It is a substantial roof exhauster designed and engineered for the duty it serves. › Powered Airette Direct Drive Series Model: AC • Static pressure up to 0.50” • Flow capacity between 1,600 - 22,600 CFM › Powered Airette Belt Drive Series Model: AC • Static pressure up to 0.50” • Flow capacity between 2,500 - 75,000 CFM Model: AF • Static pressure up to 0.50” • Flow capacity between 2,900 - 47,650 CFM P o w e r e d ©PENNBARRY 2008 A i r e t t e 2 PENNBARRY WWW.PENNBARRY.COM Introduction TM Powered Airette Hooded Propeller Roof Ventilator Features & Benefits › Motor and Drive Assemblies Sturdy, structural steel mountings support these components. Mounts are properly designed for motor weight and fan speed. Mounting brackets are provided with slotted tracks for simple belt adjustment on standard belt-drive units. › Propeller Fans PennBarry’s fan blades provide QUIET air movement at maximum efficiency. This means low noise level and minimum power consumption with maximum airflow. › Weather Resistant Operation Complete weather tightness has been incorporated in the housing design. The protected perimeter exhaust outlet areas on all four sides of the generously sized square hood establish the overall symmetry of the housing. Four even outlet areas reduce discharge velocities and turbulence. Passing air currents actually assist the exhaust action regardless of wind direction. Discharge or inlet openings can be screened to prevent birds or insects from entering the housing when such protection is desired. Hooded Propeller Roof Ventilator › Housings Built of heavy gauge galvanized steel. Pretreatment provided when units are to be painted in the field to match color of other exterior metal work or when factory painting is specified. The Powered Airette is also available in maintenance-free aluminum when specified. › Adjustable Motor Pulleys Adjustable motor pulleys are standard and can provide speed and capacity flexibility on the job site. Adjustment of 1” in pitch diameter is standard (a 4” pitch diameter pulley can be varied from 3 1/2” to 4 1/2” or + 12 1/2% of rated rpm). Larger size Powered Airettes use matched multiple belts and two-groove pulleys. Motors are mounted on slotted rails to vary center-to-center distances and to adjust for proper belt tension. Vertical flexibility is also provided to permit proper pulley alignment. P o w e r e d ©PENNBARRY 2008 A i r e t t e WWW.PENNBARRY.COM PENNBARRY 3 Introduction Powered Airette Hooded Propeller Roof Ventilator TM Hooded Propeller Roof Ventilators Options & Accessories › Backdraft Dampers To prevent backdrafts, dampers are frequently used as accessories with the Powered Airette. PennBarry offers several types. Shown here, is an electric motor operated model which insures positive and tight closure for exhaust units. Others are self-acting dampers that open and close automatically with the start/stop of the fan. There are low velocity standard duty and high velocity heavy duty styles. Dampers have aluminum, felted edges with interconnecting rods that prevent blade chatter or ‘over-opening’. Damper frames are rugged, galvanized steel roll formed channels and are provided with a knock-out to permit the passage of electrical conduit. › Disconnect Switches UL listed, non-fused, safety disconnect switches can be provided to match system electrical characteristics. These can be furnished in a weatherproof (NEMA 3R or 4) enclosure specifically designed for outdoor installation or in conventional (NEMA 1) enclosures mounted inside the airshaft under the hood. › Bird Screens PennBarry supplies aluminum bird screens when such protection is desired. This screen has an 85% free area for minimum air restriction and pressure drop. The screen cannot unravel, rust or corrode and is an effective barrier against birds or debris entering the building. › Fresh Air Intake or Relief Hoods Companion units to the Powered Airette exhaust or supply fan ventilators are the Gravity Airette Fresh Air Intake or Exhaust Hoods. › Safety Guards Plant Safety Committees and officials, at times, require protective guards around rotating machinery. Accordingly, roof openings for PennBarry’s units can be easily and neatly fitted with framed safety guards. This is possible with the Powered Airette design because fan components do not intrude nor protrude below the roof line or into the well of the roof curb. › Finishes Coatings such as air dry Enamel, Epoxy, or Heresite are available upon request. See the coatings brochure for details. P o w e r e d Gravity Airette Fresh Air Intake or Exhaust Hoods are the perfect way to insure uniformity on the roof for any ventilation function: exhaust, supply, gravity ventilation, pressure relief, interior fan discharge cap or outside air intake. › Motors Continuous, heavy-duty, ball bearing motors are standard. In belt-drive units, motors are provided on adjustable bases for easy adjustment of belt tension. Ratings of standard motors are for 40°C ambient. NEMA Class B and Class F insulation is available for temperatures up to 50°C. Explosion proof motors can also be furnished. All motor sizes have been conservatively selected to insure adequate protection under normal operating conditions. Totally enclosed and variable speed motors are also available on special order. Where severe heat conditions are prevalent, glass or other specially insulated motors are necessary. For acids, fumes, excessive moisture, etc., modified designs should be used. A proper selection can be insured by consultation with the factory. ©PENNBARRY 2008 A i r e t t e 4 PENNBARRY WWW.PENNBARRY.COM Introduction Powered Airette Hooded Propeller Roof Ventilator TM Options & Accessories Illustrated here, is the Unibeam which is most generally used. Costs of this device are normally less than field built curbs. The Unibeam shown is for flat roof installation. METAL LINER (OPTIONAL ACCESSORY) INTEGRAL FIBERGLASS INSULATION WOOD NAILOR (OPTIONAL ACCESSORY) FIELD FLASHING (BY OTHERS) › Peaked or Sloped Curbs Whether the installation is on the peak or a single slope of the building, the Unibeam curb will accommodate the application. Each curb is custom built to meet the needs of the project. PEAKED ROOF SINGLE SLOPE ROOF Hooded Propeller Roof Ventilator › Roof Curbs Roof curbs are furnished in a variety of types from canted or selfflashing to sloped or flat pitch. Standard construction includes galvanized or aluminum material, insulation, and metal, rubber gasketing or wood nailer mounting surface. See the roof curbs brochure for details. TAPERED CURB MOUNTING BUILT-IN CANT STRIP (RAISED CANT OPTIONAL) ROOF DECK (BY OTHERS) INSULATION (BY OTHERS) P o w e r e d ©PENNBARRY 2008 A i r e t t e WWW.PENNBARRY.COM PENNBARRY 5 Dimensional Information Powered Airette Hooded Propeller Roof Ventilator TM AC & AF › AC & AF Dimensional Information Powered Airette ventilators are available in two standard drive arrangements. Direct drive fans with blades on the motor shaft. Belt drive units for general ventilation conditions where the motor and drive components are installed within the ventilator airshaft to take advantage of airstream cooling action. The exhausting air washes the motor and bearings to increase longevity of these components. Hooded Propeller Roof Ventilators › AC & AF Dimensional Drawings Because of physical size, the factory retains the option of shipping large units semi-knocked down when necessary. Units hoisted to the roof should have adequate slings or cradles provided. Installing contractors should secure mounting base to roof curbs with lag bolts and washers or other proper fasteners 12” O.C. When hoods are removed from airshafts during installation, contractors are cautioned to reset hoods properly with all fasteners drawn fully tight. In areas subject to high winds, it is recommended that large units be installed with guy wires. › Legend 1. Access Hood 2. Fan Casing 3. Mounting Base 4. Reinforcing Angle Frame 5. Ball Bearing Motor 6. Anti-Vibration Mounts 7. Electric Conduit Space 8.Axial Flow Propeller 9.Fan Inlet Ring 10.Belt and Pulleys 11.Weather Baffle 12.Curb and Flashing (by others) › AC Dimensional Reference P o w e r e d Size A H 24 30 36 42 48 54 60 72 26 32 38 44 50 56 62 74 21 25 25 29 29 31 33 43 Exhaust 39 48 57 66 75 84 93 93x160 L Supply 48 57 66 75 84 93 101x121 93x190 Ro E 25 31 36 44 50 55 62 72 35 41 47 53 59 65 71 83 Alum. 16-20 12-18 12-18 12-18 12-18 10-16 10-14 10-14 Gauges* Steel 18-24 16-20 16-20 16-20 16-20 16-20 16-20 14-20 All dimensions in inches. * Gauges listed first are for airshaft. Gauges listed second are for hoods. ©PENNBARRY 2008 A i r e t t e 6 PENNBARRY WWW.PENNBARRY.COM Dimensional Information Powered Airette Hooded Propeller Roof Ventilator TM AC & AF › AC & AF Dimensional Drawings ! Caution: Due to the high humidity and moisture present at the roof level, filters using hygroscopic media or cardboard frames should be avoided. Hooded Propeller Roof Ventilator › AC & AF Filter Equipped Information Clean and fresh outside air is vital to the proper functioning of many ventilating systems. Air conditioning equipment and many other devices require a dust-free and dirt-free supply of air. Powered Airette Supply Fans with cleanable filters satisfy such antipollutant requirements. Filter maintenance is important. Resistance increases when filters are dirty and pollutant carrythru will result at .25 in. w.g. › AC Filter Dimensional Reference Size 24 30 36 42 48 54 60 A sq. in. 26 32 38 44 50 56 62 E sq. in. 35 41 47 53 59 65 71 Filter Area sq. ft. 17.76 21.22 34.19 48.58 63.88 83.28 90.28 Number & Size of Filters (6) @ 16x20 & (2) @ 16x25 (2) @ 16x20 & (6) @ 16x25 (2) @ 16x25 & (10) @ 20x25 (10) @ 20x25 & (4) @ 25x25 (8) @ 16x25 & (24) @ 15x20 (24) @ 20x25 (28) @ 20x25 LxL in. 61x61 71x71 81x91 101x101* 117x121* 101x161* 117x167* Maximum CFM 350 FPM 550 FPM 6200 9700 7400 11600 12000 18800 17000 26600 22000 35000 29000 45500 31600 49650 All dimensions in inches. * Hoods shipped in one or more sections for field assembly. P o w e r e d ©PENNBARRY 2008 A i r e t t e WWW.PENNBARRY.COM PENNBARRY 7 Performance Data Powered Airette Hooded Propeller Roof Ventilator TM AC - Cast Aluminum Propeller Hooded Propeller Roof Ventilators › AC Direct Drive Performance Data Model RPM AC24W1 AC24W2 AC24T AC30W AC30T1 AC30T2 AC36W1 AC36W2 AC42W1 AC42W2 AC48W1 AC48W2 860 860 1140 860 1140 1140 860 860 860 860 860 860 0.000” SP CFM 4050 4275 5370 6825 7755 10890 10500 11795 17250 19730 19395 22610 BHP* 0.29 0.40 0.67 0.45 0.68 1.46 0.90 1.33 1.86 2.98 1.89 2.85 0.125” SP CFM 2865 3150 4520 5715 6990 10290 9175 10165 15690 17875 17550 20800 BHP* 0.27 0.40 0.65 0.46 0.71 1.48 0.92 1.34 1.90 2.97 1.96 2.89 0.250” SP CFM 1605 1885 3510 3930 5995 9690 7270 7855 13960 15710 15540 18820 BHP* 0.28 0.40 0.63 0.47 0.71 1.50 0.94 1.29 1.95 2.95 1.96 2.90 0.375” SP CFM 2565 1990 4715 8900 4895 5155 11715 13115 13185 16640 BHP* 0.64 0.50 0.72 1.49 0.98 1.28 2.00 2.95 1.93 2.90 0.500” SP CFM 1670 3435 7860 2385 9590 10285 14150 BHP* 0.72 0.74 1.46 1.37 2.96 1.90 2.91 › AC Belt Drive Performance Data Model AC24 AC30 AC36 P o w e r e d AC42 AC48 AC54 AC60 AC72 RPM 1000 1105 1265 1450 1595 1637 705 780 890 1020 1125 1280 1326 485 555 635 700 800 880 1010 1043 435 500 550 630 695 795 940 475 545 600 685 810 590 650 745 885 1015 355 405 480 550 605 380 435 515 590 650 743 TIP SPD (FPM) 6285 6945 7950 9110 10020 10286 5535 6125 6990 8010 8835 10055 10414 4570 5230 5985 6595 7540 8295 9520 9830 4785 5500 6050 6925 7640 8740 10335 5970 6850 7540 8610 10180 8340 9190 10530 12510 14350 5575 6360 7540 8640 9505 7163 8200 9708 11121 12252 14005 0.000” SP CFM 4015 4440 5080 5825 6405 6576 5915 6545 7465 8555 9435 10735 11123 7785 8910 10190 11235 12840 14125 16210 16740 10325 11870 13055 14955 16500 18870 22315 15815 18145 19975 22805 26970 21615 23815 27295 32425 37190 25855 29495 34955 40055 44060 37210 42595 50430 57775 63650 72755 BHP* 0.23 0.31 0.47 0.70 0.94 1.01 0.23 0.31 0.47 0.70 0.94 1.39 1.54 0.33 0.49 0.73 0.98 1.47 1.96 2.96 3.26 0.48 0.73 0.98 1.47 1.97 2.95 4.87 0.99 1.50 2.00 2.97 4.91 1.44 1.93 2.90 4.86 7.34 1.96 2.91 4.84 7.28 9.68 2.00 3.01 4.99 7.50 10.03 14.98 0.125” SP CFM 3380 3870 4590 5400 6025 6200 4710 5510 6630 7860 8815 10200 10608 5740 7160 8700 9900 11700 13115 15355 15912 7525 9815 11250 13440 15105 17660 21295 13050 15810 17880 20970 25425 19010 21485 25305 30795 35790 22200 26360 32290 37725 41940 28725 34670 42345 50235 56565 66320 BHP* 0.24 0.33 0.48 0.72 0.96 1.04 0.25 0.33 0.49 0.73 0.97 1.42 1.58 0.33 0.49 0.74 1.00 1.49 1.98 2.98 3.28 0.49 0.74 0.99 1.48 1.98 2.96 4.89 0.98 1.49 2.00 2.98 4.92 1.47 1.96 2.95 4.94 7.44 1.98 2.94 4.87 7.32 9.73 2.06 3.08 5.07 7.60 10.14 15.10 0.250” SP CFM 2625 3235 4060 4950 5620 5810 2935 4010 5400 6910 8020 9580 10023 2315 4270 6905 8430 10425 11965 14370 14966 3605 6745 8490 11155 13485 16395 20305 9320 12985 15455 19000 23845 16010 18845 23080 28980 34250 15915 22565 29495 35420 39880 20860 28290 38075 46370 51775 61425 BHP* 0.25 0.33 0.49 0.74 0.98 1.05 0.24 0.32 0.49 0.74 0.99 1.45 1.61 0.29 0.45 0.72 0.98 1.48 1.98 2.99 3.29 0.46 0.73 0.98 1.48 1.99 2.98 4.91 0.93 1.45 1.96 2.95 4.91 1.45 1.96 2.96 4.96 7.47 1.93 2.93 4.90 7.36 9.78 2.06 3.09 5.12 7.69 10.23 15.22 0.375” SP CFM 2510 3470 4470 5195 5400 1975 4035 5740 7060 8795 9279 3980 5900 9010 10810 13355 13988 2775 5425 8890 11105 14485 19130 8240 12735 16715 22085 12420 15895 20690 27070 32635 13940 25910 32740 37610 8455 20540 32315 41785 48830 58955 BHP* 0.33 0.50 0.75 0.99 1.07 0.33 0.48 0.73 1.00 1.47 1.63 0.66 0.93 1.45 1.96 2.98 3.29 0.73 0.92 1.46 1.98 2.97 4.93 1.37 1.89 2.89 4.87 1.37 1.91 2.93 4.95 7.48 2.80 4.87 7.37 9.80 2.10 3.09 5.12 7.70 10.30 15.34 0.500” SP CFM 2840 3945 4745 4964 2115 4540 5955 7920 8456 3670 6540 9595 12355 13015 5955 9135 12580 17510 7125 14195 20165 12380 18050 25055 30955 18225 29515 35120 8490 25900 36690 44425 55530 BHP* 0.50 0.75 1.00 1.08 0.49 0.72 0.98 1.47 1.63 0.88 1.37 1.93 2.96 3.26 1.39 1.94 2.96 4.92 1.81 2.81 4.80 1.78 2.87 4.93 7.47 4.67 7.33 9.80 3.17 5.12 7.70 10.30 15.38 Est. Ship Wt. (Lbs) Alum. Steel 250 300 300 350 400 450 550 625 675 750 Est. Ship Wt. (Lbs) Alum. Steel 250 300 300 350 400 450 550 625 675 750 900 1000 1000 1150 1150 1350 Explosion proof motors and disconnects are available WHEN SPECIFIED. * BHP does not include drive losses. See additional notes on next page. 8 PENNBARRY WWW.PENNBARRY.COM ©PENNBARRY 2008 A i r e t t e TIP SPD (FPM) 5405 5405 7165 6755 8955 8955 8105 8105 9455 9455 10805 10805 Performance Data Powered Airette Hooded Propeller Roof Ventilator TM AF - Fabricated Steel Propeller › AF Belt Drive Performance Data AF24 AF30 AF36 AF42 AF48 AF54 AF60 RPM 600 658 747 865 952 420 469 545 614 692 765 354 420 465 498 576 640 739 335 365 423 478 526 606 715 290 330 354 394 427 507 604 263 310 342 390 462 542 284 310 352 421 490 TIP SPD (FPM) 3770 4134 4694 5435 5982 3299 3684 4280 4822 5435 6008 3336 3958 4383 4694 5429 6032 6965 3684 4013 4651 5256 5784 6663 7862 3644 4147 4448 4951 5366 6371 7590 3718 4383 4835 5513 6531 7662 4461 4869 5529 6613 7697 0.000” SP CFM 4475 4908 5572 6452 7101 6312 7049 8191 9228 10401 11498 8153 9673 10709 11470 13266 14740 17020 12220 13315 15430 17437 19188 22106 26082 14409 16397 17590 19577 21217 25192 30012 19185 22614 24948 28450 33702 39538 26649 29089 33030 39505 45980 BHP 0.25 0.32 0.47 0.74 0.98 0.23 0.32 0.51 0.73 1.04 1.40 0.34 0.57 0.77 0.95 1.47 2.02 3.10 0.53 0.69 1.07 1.55 2.07 3.16 5.19 0.56 0.82 1.01 1.39 1.77 2.97 5.02 0.84 1.38 1.86 2.75 4.58 7.39 1.53 2.00 2.92 5.00 7.88 0.125” SP CFM 3901 4411 5162 6118 6797 4678 5680 7072 8263 9560 10746 6564 8453 9667 10538 12540 14146 16506 10253 11616 14051 16248 18135 21205 25319 11847 14347 15770 18048 19889 24124 29158 15865 19837 22459 26298 31901 38016 22369 25311 29748 36802 43688 BHP 0.25 0.32 0.47 0.74 0.98 0.25 0.34 0.53 0.75 1.06 1.43 0.37 0.61 0.81 0.99 1.51 2.06 3.15 0.56 0.71 1.10 1.58 2.10 3.20 5.24 0.61 0.88 1.08 1.47 1.85 3.06 5.13 0.96 1.53 2.02 2.94 4.80 7.65 1.61 2.08 3.02 5.12 8.03 0.250” SP CFM 2909 3446 4561 5663 6424 2947 3717 5519 7040 8575 9900 4949 6818 8201 9206 11452 13200 15802 7012 8342 11906 14699 16851 20185 24515 10576 12191 15578 17861 22671 28134 11762 16657 19684 23988 29997 36439 18140 21413 26054 33851 41256 BHP 0.28 0.37 0.50 0.74 0.98 0.27 0.36 0.55 0.78 1.10 1.46 0.43 0.63 0.84 1.03 1.57 2.13 3.22 0.61 0.75 1.12 1.61 2.14 3.24 5.28 0.97 1.15 1.56 1.93 3.17 5.25 1.08 1.65 2.16 3.12 5.02 7.91 1.69 2.16 3.10 5.23 8.17 0.375” SP CFM 2922 3671 5059 5947 4086 5454 7322 8891 6994 7891 10250 12152 14956 6682 9108 12045 15028 18958 23623 12252 14496 20831 26785 16686 21307 28037 34778 22755 30789 38526 BHP 0.39 0.55 0.82 1.02 0.57 0.80 1.13 1.51 0.93 1.08 1.61 2.18 3.30 0.92 1.20 1.64 2.16 3.28 5.33 1.68 2.04 3.26 5.37 2.29 3.25 5.21 8.18 3.21 5.33 8.27 0.500” SP CFM 3270 4262 5118 4475 5852 7671 6910 9137 11037 14031 7783 10091 12357 17276 22582 12278 17770 25268 18713 25617 33108 28117 35966 BHP 0.57 0.85 1.10 0.83 1.15 1.53 1.20 1.66 2.19 3.36 1.43 1.76 2.23 3.30 5.38 2.21 3.38 5.47 3.42 5.37 8.40 5.45 8.39 Est. Ship Wt. (Lbs) Alum. Steel 250 300 300 350 300 350 400 450 675 750 900 1000 1000 1150 Hooded Propeller Roof Ventilator Model Fan capacity ratings are certified to be in accordance with the Standard Test Code for axial fans as adopted by AMCA (AMCA Bulletin 210-07). Higher speed fans are intended for industrial use. Low noise level fans should be selected from the lower speeds. Shipping weights are for exhaust models. P o w e r e d ©PENNBARRY 2008 A i r e t t e WWW.PENNBARRY.COM PENNBARRY 9 Engineering Specifications Powered Airette Hooded Propeller Roof Ventilator TM Engineering Specifications Hooded Propeller Roof Ventilators › Model AC= Cast Aluminum Propeller AF= Fabricated Steel Propeller › Unit Size 24 30 36 42 48 54 60 72 › Drive Type 0 = None T = 1140 RPM T1 = 1140 RPM T2 = 1140 RPM W = 860 RPM W1= 860 RPM W2= 860 RPM › Motor Speed 0= None 1= Single Speed 2= 2 Speed 2 Winding 1800/1200 3= 2 Speed 1 Winding 1800/900 › Horse Power 2 3 5 O = Open Drip Proof T = Totally Enclosed E = Explosion Proof X = Special P o w e r e d › Voltage B= 115V D= 200V E= 208V G= 230V P= 460V R= 575V X= Special › Phase 1 = Single 3 = Three › Cycle 5= 50 Hz 6= 60 Hz › Efficiency S= Standard P= Premium 10 PENNBARRY › Damper Holding Plate 0 = None B= Epoxy* Q= Enamel X= Special 0 = None P= Damper Holding Plate 7 1/2 10 15 › Neoprene Gasket 0 = None G= Gasket 0 = None 51= Light Bronze 53= Aegean Blue 55= Patina 56= Dove Gray 61= Bone White 63= Oxford Beige 65= Dover White 66= Desert Tan 70= Black 73= Smoke Gray 77= Brick Red 79= Peppercorn 81= Medium Bronze 83= Dark Bronze 85= Statuary Bronze 94= Charcoal X = Special › No Wooden Nailer › Aluminum Housing › Lube Lines › Damper › Zerk Lube Fitting 0 = Wood Nailer N= No Wooden Nailer › Curb Paint/Coating B= Air Dried Epoxy Q= Enamel › Screen 0= None B= Bird Screen S= Insect/Bird Screen › Supply Hood / Filters 0 = None L = LFH Supply Hood with Filter N=NFH Supply Hood without Filter 0 = None A = Aluminum 0 = None L = Lube Lines 0 = None BDD = Gravity Backdraft Damper CBD = Counter Balanced Supply Damper MD1 = Motor Operated Damper 115V MD2 = Motor Operated Damper 230V MD4 = Motor Operated Damper 460V X = Special › Roof Curb 0 = None A = UCG8 B= UCG12 C= UCG18 D= UCA8 E= UCA12 F = SFA12 G= SFA18 H= SCG16 J = SCA16 › Slope 0 = None S= Single D= Double K= UCA18 L = UG12 M= SA16 N= SFG12 P= SFG18 Q= SG16 R= SRA16 S= SRG16 T = UA12 U= UA18 V = UG18 W= URA12 Y = URA18 1 = URG12 2 = URG18 X = Special 0 = None F = Zerk Lube Fitting › Belt Cover 0 = None B= Belt Cover › Safety Guard 0 = None G= Safety Guard › Thermal Protection 0 = None P= Thermal Protection › Disconnect Switch 0 = None 1 = NEMA 1 Disconnect Switch 3R= NEMA 3R Disconnect Switch 4 = NEMA 4 Disconnect Switch 7 = NEMA 7 Disconnect Switch 9 = NEMA 9 Disconnect Switch X = Special ©PENNBARRY 2008 A i r e t t e › Paint / Coating 0 = None L = Metal Liner › Color › Motor Tap › Enclosure › Metal Liner E= Exhaust S= Supply * Not available with choice of color. D= Direct Drive B = Belt Drive 0 = None 1/4 3/4 1/3 1 1/2 1 1/2 X = Special › Application E/S WWW.PENNBARRY.COM Engineering Specifications TM Powered Airette Hooded Propeller Roof Ventilator Engineering Specifications 0 = None 1 = NEMA 1 Internal Wiring 3R= NEMA 3R Internal Wiring › Firestat Switch 0 = None F = Firestat Switch › AC Belt Drive Fans Belt drive Axial Hooded Roof Fans, exhaust or supply, shall be Powered Airette model AC manufactured by PennBarry of Richardson, TX 75081. Fans shall be weather resistant and properly installed to withstand prevailing winds and bird screen shall be optional. Fans shall be integrally mounted in the ventilator housing. No portion shall protrude below the roof line. Hoods shall be hinged for complete access and shall incorporate low silhouette design with four sided discharge or inlet. Units shall be constructed for curb mounting, be securely fastened, and properly flashed. Statically and dynamically balanced propellers shall be cast aluminum airfoil. Motors shall be continuous duty, ball bearing design, positively cooled, and furnished at the specified voltage and phase. › AF Belt Drive Fans Belt drive Axial Hooded Roof Fans, exhaust or supply, shall be Powered Airette model AF manufactured by PennBarry of Richardson, TX 75081. Fans shall be weather resistant and properly installed to withstand prevailing winds and bird screen shall be optional. Fans shall be integrally mounted in the ventilator housing. No portion shall protrude below the roof line. Hoods shall be hinged for complete access and shall incorporate low silhouette design with four sided discharge or inlet. Units shall be constructed for curb mounting, be securely fastened, and properly flashed. Hooded Propeller Roof Ventilator › Internal Wiring Statically and dynamically balanced propellers shall be heavy gauge fabricated steel. Motors shall be continuous duty, ball bearing design, positively cooled, and furnished at the specified voltage and phase. › AC Direct Drive Fans Direct drive Axial Hooded Roof Fans, exhaust or supply, shall be Powered Airette model AC manufactured by PennBarry of Richardson, TX 75081. Fans shall be weather resistant and properly installed to withstand prevailing winds and bird screen shall be optional. Fans shall be integrally mounted in the ventilator housing. No portion shall protrude below the roof line. Hoods shall be hinged for complete access and shall incorporate low silhouette design with four sided discharge or inlet. Units shall be constructed for curb mounting, be securely fastened, and properly flashed. Statically and dynamically balanced propellers shall be cast aluminum airfoil. Motors shall be continuous duty, ball bearing design, positively cooled, and furnished at the specified voltage and phase. › Product Configuration Reference PennBarry’s Fansizer selection software to configure a Powered Airette product today. P o w e r e d ©PENNBARRY 2008 A i r e t t e WWW.PENNBARRY.COM PENNBARRY 11 Notes TM Hooded Propeller Roof Ventilators Powered Airette Hooded Propeller Roof Ventilator P o w e r e d ©PENNBARRY 2008 A i r e t t e 12 PENNBARRY WWW.PENNBARRY.COM Sales Agreement TM Powered Airette Hooded Propeller Roof Ventilator 1-Year Limited Manufacturer Warranty › Products Covered PennBarry Fans and Ventilators (each, a “PennBarry Product”) › One Year Limited Warranty For PennBarry Products PennBarry warrants to the original commercial purchaser that the PennBarry Products will be free from defects in material and workmanship for a period of one (1) year from the date of shipment. › Exclusive Remedy PennBarry will, at its option, repair or replace (without removal or installation) the affected components of any defective PennBarry Product; repair or replace (without removal or installation) the entire defective PennBarry Product; or refund the invoice price of the PennBarry Product. In all cases, a reasonable time period must be allowed for warranty repairs to be completed. › What You Must Do In order to make a claim under these warranties: • You must be the original commercial purchaser of the PennBarry Product. • You must promptly notify us, within the warranty period, of any defect and provide us with any substantiation that we may reasonably request. • The PennBarry Product must have been installed and maintained in accordance with good industry practice and any specific PennBarry recommendations. › Exclusions These warranties do not cover defects caused by: • Improper design or operation of the system into which the PennBarry Product is incorporated. • Improper installation. • Accident, abuse or misuse. • Unreasonable use (including any use for non-commercial purposes, failure to provide reasonable and necessary maintenance as specified by PennBarry, misapplication and operation in excess of stated performance characteristics). • Components not manufactured by PennBarry. › Limitations • In all cases, PennBarry reserves the right to fully satisfy its obligations under the Limited Warranties by refunding the invoice price of the defective PennBarry Product (or, if the PennBarry Product has been discontinued, of the most nearly comparable current product). • PennBarry reserves the right to furnish a substitute or replacement component or product in the event a PennBarry Product or any component of the product is discontinued or otherwise unavailable. • PennBarry’s only obligation with respect to components not manufactured by PennBarry shall be to pass through the warranty made by the manufacturer of the defective component. › General The foregoing warranties are exclusive and in lieu of all other warranties except that of title, whether written, oral or implied, in fact or in law (including any warranty of merchantability or fitness for a particular purpose). PennBarry hereby disclaims any liability for special, punitive, indirect, incidental or consequential damages, including without limitation lost profits or revenues, loss of use of equipment, cost of capital, cost of substitute products, facilities or services, downtime, shutdown or slowdown costs. The remedies of the original commercial purchaser set forth herein are exclusive and the liability of PennBarry with respect to the PennBarry Products, whether in contract, tort, warranty, strict liability or other legal theory shall not exceed the invoice price charged by PennBarry to its customer for the affected PennBarry Product at the time the claim is made. ©PENNBARRY 2008 Inquiries regarding these warranties should be sent to: PennBarry, 1401 North Plano Road, Richardson, TX 75081 WWW.PENNBARRY.COM PENNBARRY Other PennBarry Products Centrifugal Products CENTRIFUGAL PRODUCTS CENTRIFUGAL PRODUCTS ›Domex › Fumex › Zephyr › Dynamo Domex Fatrap Fumex Fatrap Zephyr Dynamo Fumex Fatrap Zephyr Dynamo Domex Centrifugal Kitchen Hood Centrifugal Ceiling and Inline Fans Centrifugal Blowers Centrifugal Kitchen Hood Centrifugal Ceiling and Inline Fans Centrifugal Centrifugal Kitchen Hood Centrifugal Ceiling and Inline Fans Centrifugal Blowers Blowers Roof Exhausters RoofRoof Exhausters Roof Roof Exhausters Exhausters Exhausters Roof Exhausters Roof Exhausters Roof Exhausters Centrex Inliner LC Dynafan ESI Fume Exhaust ›Centrex › Fume CentrexInliner Inliner LC Dynafan Exhaust LC› Dynafan ESI› ESI Fume Exhaust Centrifugal Inline Fans Low Contour Centrifugal Efficient Silent Curb Mounted InlineInline Fans Fan Low Contour Centrifugal Silent Silent Curb Mounted Centrifugal Centrifugal Low Contour Centrifugal Efficient Efficient CurbFans Mounted Roof Exhausters Inline Fan Centrifugal RoofRoof Exhausters InlineInline Fan Fan Centrifugal Fans Fans Exhausters Centrifugal AXIAL PRODUCTS AXIAL GRAVITY PRODUCTS Axial// /GRAVITY Gravity Products ›Breezeway › Hi-Ex › Tubeaxial › Vaneaxial Breezeway HI-EX Tubeaxial Vaneaxial Breezeway HI-EX Tubeaxial Vaneaxial Wall Fans Power Roof Inline Fans Inline Fans Propeller Propeller Power Roof Ventilator Propeller WallWall FansFan Power Roof Ventilator Ventilator InlineInline Fans Fans Inline Inline Fans Fans › Powered Airette › Airette › Domex Axial › Axcentrix Powered Airette Airette Domex Axial Axcentrix Airette Airette Domex Axial Axcentrix Powered Axial Roof Ventilators Gravity Intake/Relief Hood Roof Ventilators Bifurcator Fan Axial Axial Roof Ventilators Axial Roof Ventilators Gravity Intake/Relief Hood Bifurcator Fan Axial Roof Ventilators Gravity Intake/Relief Hood Axial Roof Ventilators Bifurcator Fan For For more more information information contact contact your your local local PennBarry PennBarry Sales Sales Manufacturer Representative or visit us at For more information, contact your local PennBarry Sales Manufacturer Representative or visit us at Manufacturer Representative or visit us at www.PennBarry.com. TM ©2005 PennBarry™ ©2005 PennBarry PennBarry™ ™ ©2009 ©2005 PennBarry™ All Rights Rights Reserved. Reserved. February 2005 2005 All All Reserved. February December All Rights Rights Reserved. February 20052009