Electric Products, Inc.
Quality Weatherproof
Electrical Equipment
RV product catalog
MEPC-RV09
Midwest Electric Products, Inc.
P.O. Box 910
Mankato, MN 56002-0910
Customer Service Phone: (507) 345-2505
Customer Service Fax: (507) 345-2530
www.midwestelectric.com
How to Use This Catalog
Midwest Electric Products, Inc., is pleased to introduce our
Recreational Vehicle product catalog. The product alphanumeric list is found on page 5.
Each model number is described in the following manner
within its respective section:
Example
Model Layout Drawing
Model Layout Drawing
An easy-to-understand diagram that illustrates the internal
component configuration.
Model Data Table
The table is located on the same page as the Model Layout
Drawing. This table thoroughly defines each model, as well
as all necessary ordering information. These tables may vary
slightly between sections to best describe each product line.
Technical Data Table
5-20R2GFI
Following the Model Data Tables and Model Layout
Drawings, we have included a table at the end of each section
that defines specific information including replacement parts,
cabinet dimensions, enclosure styles, and knockout
configurations.
(2) 14-50R
A
M004C010
Example
Model Data Table
FIG. UL
A
Y
MODEL NUMBER
RING TYPE
RINGLESS
M004C010
——
RECEPTACLES
CIRCUIT
PROTECTION
(2) CB250
CB120
5-20R2GFI
(2) 14-50R
AMP VOLTS
100
120/240
WIRE CABINET
HUB
LOAD &
UNIT STD.
RANGE*
SIZE
OPENING NEUTRAL BAR WT. PKG.
AA
9 X 30
Y
LC55N1
26
Example
Technical Data Table (found at the end of each product section)
REPLACEMENT PARTS
MODEL
NUMBER
M004C010
2
HUB
OPENING
CABINET DIMENSIONS
METER
SOCKET
POST
LUGS
CABINET
SIZE
page
MSM100930
——
9 X 30
ENCLOSURE
STYLE
page
HEIGHT
WIDTH
DEPTH
A
B
C
KNOCKOUT
FIGURE
page
B
30"
9-3/4"
5-3/16"
2
1
How to Use This Catalog
Model Diagram Symbol Key
Meter Socket
Circuit Breaker space: 2-pole Plug-In Style
Circuit Breaker Installed: 1-pole Plug-In Style
GE - KR Style Main Breaker
Circuit Breaker Installed: 2-pole Plug-In Style
SPACE
GE - KR Style Main Breaker Space
Circuit Breaker space: 1-pole Plug-In Style
For Receptacle Identification.
Timer
Lug
See Application Data
Model Number System Key
Model Numbers are based on the following system:
Example: Model Number U041CP6010
unmetered
0
4
1
series number
{
U
METERING
M = Ring-Type Meter
Socket
R = Ringless
Meter Socket
SERIES NUMBER
Assigned by Midwest
U = Unmetered
C
P6
010
circuit breaker
Earth Burial Post
Options
POST OPTIONS
B4 = Back to Back Pad
Mounted Post
010 = GFCI Duplex
Receptacle
B6 = Back to Back Earth
Burial Post
031 = GFCI Duplex
Receptacle; TV/Tel
H = Head Post Design
033 = GFI Breaker
(Double Pole); GFCI
Duplex Receptacle
TYPE OF PROTECTION
HP = Head Post Design
C = Circuit Breaker installed
P4 = Pad Mounted Post
E = Empty Spaces for FieldInstalled Breakers
P6 = Earth Burial Post
F = Fused
G = Ground Fault Breaker
Protection
H = Hybrid: Combination of
Different Protection
EXAMPLE:
Fuse/Switch
OPTIONS
034 = Meter with Lever
Bypass
R1 = Vertical Barrier for Meter
039 = 350 MCM Lugs
Compartment (Top & Bottom)
L10 = Lighted with GFCI
R2 = Horizontal Barrier Between
Receptacles
Meter and Circuit Breaker
L31 = Lighted with
Compartments. Vertical
TV/Tel
Barriers in Both Meter and
Circuit Breaker Compartments.
P = Puller, Non-Fused
S4 = Stud Termination Pad Mounted
Post
T = Circuit Breaker with
Triple Tap Lugs
S6 = Stud Termination Earth Burial
Post
TL = Twin Lugs Per Phase (Loopfeed for Surface Mount Units)
W4 = Back to Back, Stud
Termination Pad Mounted Post
W6 = Back to Back, Stud
Termination Earth Burial Post
B1 = Barrier (Bottom)
3
Product Features and Warranty
All equipment manufactured by Midwest Electric Products,
Inc. , contains a label located on the inside of the door which
gives electrical data and wiring information for the unit. On
select models the label also lists the renewal parts for the unit.
Pictured below is a sample label.
TYPICAL WIRING DIAGRAM
BOND WHEN USED AS SERVICE EQUIPMENT. (CONNECT TO ANY OPEN
SIDE OR END HOLE ON NEUTRAL.)
- LINE -
LOOP
FEED
INSUL.
NEUTRAL
S
P
A
C
E
BONDING
JUMPER
RAINPROOF POWER OUTLET
LISTED
POWER OUTLET
B6FL
SUITABLE FOR USE AS
RECREATIONAL
VEHICLE SITE SUPPLY
EQUIPMENT. IF USED
AS RECREATIONAL
VEHICLE SITE SUPPLY
EQUIPMENT, DO NOT
BOND NEUTRAL.
EQUIP.
GRD.
TEST MONTHLY
- LOAD RECEPT.
GRD.
IF FEED-THROUGH CIRCUIT IS
UTILIZED FIELD WIRE FROM
“LOAD” TERMINALS.
GROUND FAULT
PROTECTED - WARNING:
PERSONS CONTACTING
MORE THAN ONE LEG OF
THE CIRCUIT AT THE SAME
TIME ARE NOT PROTECTED.
USE COPPER WIRE ONLY EXCEPT LINE, NEUTRAL AND EQUIPMENT
GROUND TERMINALS ARE SUITABLE FOR CU OR AL CONDUCTORS.
MODEL NO.
U075CTL010
100 AMPS MAX. 120/240 VOLTS A - C
3 WIRE, 1 PHASE
TYPE 3R ENCLOSURE
USE ONLY 80 DEG. C (140 DEG.F) CONDUCTORS ON ALL
FIELD INSTALLED LINE, LOAD AND NEUTRAL TERMINATIONS.
THE FOLLOWING GFCI RECEPTACLES MAY BE UTILIZED
IN THIS EQUIPMENT: ARROW HART: CAT NOS. GF6242
AND GF6342. LEVITON: CAT NOS. 6803, 6899, 6580, AND 6589.
ADDITIONAL CIRCUIT BREAKER SPACE PROVIDED FOR
(1): G.E. TYPE THQL 20 AMP MAX. SINGLE -POLE, ITE/SIEMENS
TYPE Q OR CUTLER HAMMER/BRYANT/WESTINGHOUSE TYPE BR.
OVER CURRENT PROTECTION
IF BREAKER TRIPS, HANDLE WILL BE IN INTERMEDIATE POSITION.
TO RESTORE SERVICE; 1. MOVE HANDLE TO “OFF” POSITION,
2. THEN TO “ON” POSITION.
LUG TIGHTENING TORQUE (LB - IN)
SCREW TYPE
WIRE SIZE
14-10
8
8-4
3-2/0
SLOTTED
WARNING: TO AVOID ACCIDENTAL CONTACT WITH LIVE
PARTS, CLOSE ALL OPENINGS WITH BREAKERS OR FILLER
PLATES: CAT. NO. 265A5003P1 FOR (1) POLE FILLER PLATE.
ALUMINUM TERMINATIONS: TO HELP GUARD AGAINST OVERHEATING
WHEN CONNECTING ALUMINUM WIRE IN CU/AL LUG, REMOVE OXIDE
FILM FROM WIRE AND PROTECT IT WITH OXIDE INHIBITING COMPOUND.
TEST PROCEDURE FOR GFCI RECEPTACLE
1. PUSH TEST BUTTON. RESET BUTTON SHOULD POP OUT FROM INNERSURFACE. THIS SHOULD RESULT IN POWER BEING OFF AT ALL OUTLETS
PROTECTED BY THE GFCI. VERIFY BY PLUGGING TEST LAMP INTO EVERY
SUCH OUTLET. IF YOUR GFCI HAS AN INDICATOR LIGHT, THIS LIGHT SHOULD
BE ON WHEN CIRCUIT IS COMPLETE. TEST WITH TEST LAMP TO DETERMINE
CONDITION OF CIRCUIT AND PROPER OPERATION OF INDICATOR LIGHT.
CAUTION: IF RESET BUTTON DOES NOT POP OUT OR IF TEST LAMP OR
INDICATOR LIGHT REMAINS LIT WHEN RESET BUTTON DOES POP OUT, DO
NOT USE ANY OUTLETS ON THE CIRCUIT. CALL A QUALIFIED ELECTRICIAN.
2. IF THE GFCI TEST OKAY, RESTORE POWER BY PUSHING THE RESET
BUTTON BACK IN. THE RESET BUTTON MUST BE PUSHED FIRMLY AND
FULLY INTO PLACE UNTIL IT LOCKS AND REMAINS DEPRESSED AFTER
PRESSURE HAS BEEN REMOVED. IF THE GFCI FAILS TO RESET PROPERLY,
DO NOT USE - CALL A QUALIFIED ELECTRICIAN. TEST LAMP AND/OR
INDICATOR LIGHT SHOULD AGAIN LIGHT PROPERLY, DO NOT USE - CALL A
QUALIFIED ELECTRICIAN. TEST LAMP AND/OR INDICATOR LIGHT SHOULD
AGAIN LIGHT.
SHORT CIRCUIT CURRENT RATING OF THIS POWER OUTLET IS 10,000 RMS
SYMMETRICAL AMPERES, 240 VOLTS AC MAX., THE BREAKER SHALL HAVE
MINIMUM INTERRUPTING RATING OF 10,000 AMPS RMS. ADDITIONAL OR
REPLACEMENT CIRCUIT BREAKERS SHALL BE OF THE SAME
MANUFACTURER AND TYPE DESIGNATION AND SHALL HAVE AN EQUAL OR
GREATER SHORT CIRCUIT CURRENT RATING.
TORQUE
32-95
36-40
40-45
45-50
WIRE RANGE
CONNECTOR
COPPER
SOLID
STRD
14-8
14-1/0
14-10
14-10
12-8
12-1/0
14-8
14-4
12-8
12-2
LINE - CB BASIC JL - LOOP
LOAD - PLUG/DUPLEX
NEUTRAL - LARGE HOLE
NEUTRAL - SMALL HOLE
EQUIPMENT GRD. - GL3
ALUMINUM
SOLID
STRD
12-8
12-1/0
--------12-8
10-1/0
12-8
12-4
12-8
12-2
WHEN CABINET HAS PROVISIONS FOR A CONDUIT HUB. SELECT
FROM THE CHART BELOW:
CONDUIT
SIZE
CAT. NO.
CLOSURE
CAP
B01
3/4
1
1-1/4
1-1/2
B07
B10
B12
B15
DANGER
HAZARD OF ELECTRICAL
SHOCK OR BURN. TURN OFF
POWER BEFORE WORKING
INSIDE THIS EQUIPMENT.
MIDWEST ELECTRIC PRODUCTS, INC.
P.O. BOX 910
MANKATO, MN 56002-0910
WWW.MIDWESTELECTRIC.COM
MNP600737 XXXXX
Warranty
MIDWEST ELECTRIC PRODUCTS, INC.
The Company warrants to the Purchaser that the equipment to be delivered hereunder will be free from defects in
material or workmanship and will be of the kind and quality designated or specified in the contract.
This warranty shall apply only to defects appearing within one year from the date of shipment by the company.
If the equipment delivered hereunder does not meet the above warranty, and if the Purchaser promptly notifies the
Company, the Company shall thereupon correct any defect including nonconformance with the specifications either
(at its option), by repairing any defective or damaged parts of the equipment, or by making available at the Company's
plant necessary repaired or replacement parts. The liability of the Company under this warranty (except as to title), or
for any loss or damage to the equipment whether the claim is based on contract or negligence, shall not in any case
exceed the cost of correcting defects in the equipment as herein provided and upon the expiration of the warranty
period all such liability shall terminate. The foregoing shall constitute the exclusive remedy of the Purchaser and the
exclusive liability of the Company.
The foregoing warranty is exclusive and in lieu of all other warranties, whether written, oral, implied, or statutory
(except as to title). NO WARRANTY OF MERCHANTABILITY OR FITNESS FOR PURPOSE SHALL APPLY. The
Company does not warrant any equipment of other manufacture designated by the Purchaser.
4
Alpha-Numeric Index
Model Number
Page No.
121 ..................................................33
131 ..................................................33
265A5003P1 ...................................33
265A5003P2 ...................................33
520R2 .............................................32
520R2GFI .......................................32
AD2030 ...........................................32
AD3020 ...........................................32
AD5020 ...........................................32
ASR1 ..............................................33
B01 .................................................33
B07 .................................................33
B10 .................................................33
B12 .................................................33
B15 .................................................33
B20 .................................................33
B25 .................................................33
BR32U ............................................32
BR33 ...............................................32
BR34 ...............................................32
BR53 ...............................................32
BR54U ............................................32
BR64U ............................................32
C32U...............................................32
C33 .................................................32
C34 .................................................32
C53 .................................................32
C54 .................................................32
C54U...............................................32
C64U...............................................32
CLP1 ...............................................34
EK126 .............................................33
EK129 .............................................33
FBEM9 ............................................33
LC1212PC ......................................35
LC33N1...........................................35
LC33N1T ........................................35
LC33N7...........................................35
LC44X1 ...........................................35
LC55N1...........................................35
LC55N1T ........................................35
M004C010 ......................................10
M004CP6010 ..................................14
M031C010 ......................................10
M041C010 ......................................10
M041CB6010 ..................................16
M041CP4010 ..................................14
M041CP4L10 ..................................17
M041CP4L31 ..................................17
M041CP6010 ..................................14
M041CP6L10 ..................................17
M041G ............................................10
M041GB6........................................16
M041GP4........................................14
M041GP6........................................14
M055C010 ......................................10
M055G ............................................10
M055GP6........................................14
M075C010 ......................................10
M075CB4010 ..................................16
M075CB6010 ..................................16
M075CB6031 ..................................16
M075CP4010 ..................................14
M075CP4L10 ..................................17
M075CP4L31 ..................................17
M075CP6010 ..................................14
M075CP6031 ..................................14
M075CP6L10 ..................................17
M075CP6L31 ..................................17
M075CP6L39 ..................................17
M075G ............................................10
M075GB6........................................16
M075GP4........................................15
M075GP6........................................15
M076C010 ......................................10
M355C010 ......................................10
M355CP6010 ..................................15
M355G ............................................10
M355GB6........................................16
M355GP4........................................15
M355GP6........................................15
M355GP6028..................................15
M358CP6 ........................................15
M655GB6........................................16
M655GP6........................................15
Model Number
Page No.
M775CB6010 ..................................16
M775CP6010 ..................................15
MS62 ..............................................33
MSM100930 ...................................35
MSM100P9 .....................................35
MSR100930 ....................................35
MSR100P9 .....................................35
MW200M ........................................35
P5POST..........................................32
P6POST..........................................32
PCAMOTEX....................................33
PBLUE ............................................33
PBLUETEX .....................................33
PBRONZETEX ...............................33
PGRAY61........................................33
PTAN...............................................33
PTANTEX........................................33
PWHITE ..........................................33
PWHITETEX ...................................33
PLK50 .............................................34
PR32U ............................................32
PR33 ...............................................32
PR34 ...............................................32
PR53 ...............................................32
PR54U ............................................32
PR64U ............................................32
R031C010.......................................10
R041C010.......................................10
R041CP6010 ..................................14
R041G ............................................10
R041GB6 ........................................16
R041GP6 ........................................14
R055C010.......................................10
R055G ............................................10
R075C010.......................................10
R075CB6010 ..................................16
R075CP4010 ..................................14
R075CP6010 ..................................14
R075CP6031 ..................................14
R075GB6 ........................................16
R075GP6 ........................................15
R076C010.......................................10
R32U...............................................32
R355CP6010 ..................................15
R355CP6031 ..................................15
R355G ............................................10
R355GP6 ........................................15
SFEM6 ............................................33
SFEM9 ............................................33
SNPR1 ............................................33
SUBSTATION .................................34
TTV100 ...........................................33
U004CB4010 ..................................13
U004CB6010 ..................................13
U004CP4010...................................11
U004CP4031..............................11,19
U004CP6010...................................11
U01 .................................................33
U010C010.........................................8
U010G ..............................................8
U011C010 .........................................8
U011CP4010...................................11
U011CP6010...................................11
U011CTL010.....................................8
U011G...............................................8
U011GB4 ........................................13
U011GB6 ........................................13
U011GP4.........................................11
U011GP6.........................................11
U011GTL...........................................8
U031C010.........................................8
U04 .................................................33
U040G ..............................................8
U040GP4 ........................................11
U040GP6 ........................................11
U040GP6010 ..................................11
U040GTL ..........................................8
U041C010.........................................8
U041CB4010 ..................................13
U041CB4L10 ..................................18
U041CB6010 ..................................13
U041CB6L10 ..................................18
U041CP4010...................................11
U041CP4031...................................11
U041CP4039...................................11
Model Number
Page No.
U041CP4L10 ..................................18
U041CP6010...................................11
U041CP6031..............................11,19
U041CP6039...................................11
U041CP6L10 ..................................18
U041CTL010 ....................................8
U041CTLL10 ..................................17
U041G ..............................................8
U041GB4 ........................................13
U041GB6 ........................................13
U041GP4 ........................................11
U041GP4L ......................................18
U041GP6 ........................................11
U041GP6L ......................................18
U041GTL ..........................................9
U042GB6 ........................................13
U042GP6 ........................................11
U043GP6 ........................................11
U055C010.........................................9
U055CP4010...................................11
U055CP6010...................................11
U055G ..............................................9
U055GB6 ........................................13
U074GTL ..........................................9
U075CB4010 ..................................13
U075CB4031 .............................13,19
U075CB4L10 ..................................18
U075CB6010 ..................................13
U075CB6031 .............................13,19
U075CB6L10 ..................................18
U075CP4010...................................11
U075CP4031..............................11,19
U075CP4L10 ..................................18
U075CP4L31 .............................18,19
U075CP6010...................................11
U075CP6010D ................................11
U075CP6031..............................11,19
U075CP6039...................................11
U075CP6039D ................................11
U075CP6L10 ..................................18
U075CP6L31 .............................18,19
U075CTL010 ....................................9
U075CTLL10 ..................................17
U075GB6 ........................................13
U075GP4 ........................................11
U075GP4L ......................................18
U075GP6 ........................................11
U075GP6019 ..................................11
U075GP6L ......................................18
U075GTL ..........................................9
U076C010.........................................9
U10 .................................................33
U12 .................................................33
U131CP6010 ..................................12
U131CTL010 ....................................9
U15 .................................................33
U175CP6HP010 .............................12
U20 .................................................33
U25 .................................................33
U30 .................................................33
U35 .................................................33
U355C010.........................................9
U355G ..............................................9
U355GP6 ........................................12
U40 .................................................33
U412CP6010 ..................................12
U412G ..............................................9
U412GP6 ........................................12
U611CB4010...................................13
U611CB6010...................................13
U611CP4010...................................12
U611CP6010...................................12
U611CTL010.....................................9
U611GTL...........................................9
U775C010.........................................9
U775CP4010 ..................................12
U775CP6010 ..................................12
UH11AL...........................................34
UH12AL ..........................................34
UH20GG .........................................34
UH90G ............................................34
UH90GT..........................................34
UH90ST ..........................................34
UWATER34.....................................34
Search e-Catalog for More Products Online at http://www.midwestelectric.com
5
Available Models
RV Park Equipment
RV Metallic
pg. 7
-
Painted galvanized steel
Surface mounts available
Metered, unmetered, lighted, and TV/Tel available
RV Equipment available factory assembled on a
padmount or earth-burial post for underground
services
- 200-Amp Loop Feed lugs have twin 2-250 MCM
minimum terminals per phase Cu/Al
- All components are factory wired and assembled,
reducing installation time
- Single or Double-sided models available
- Padlock provision can prevent unauthorized entry
- UL listed
PARKMATETM
pg. 27
- Wide array of accessories: light, photoelectric
sensor, telephone, cable TV connections, and
electronic metering
- VALOX thermoplastic enclosure and internal
components are corrosion resistant
- Post is galvanized or stainless steel
- Factory wired power receptacles are available
in 20, 30, or 50 Amp configurations, protected
by thermal magnetic circuit breakers. Ground
fault breakers are also available
- Surface, earth burial, or padmount post available
- Single or Double-sided models available
- Pedestal features 350 MCM minimum loop
feed lugs
- UL listed
PARKRANGERTM
pg. 30
- Specific to padmount
- Corrosion resistant Non-Metallic power pedestal
- Wide array of accessories: light, photoelectric
sensor, telephone, cable TV connections, and
electronic metering
- Factory wired power receptacles are available in
20, 30, 50, or 100 Amp configurations, protected
by thermal magnetic circuit breakers. Ground
fault breakers are also available
- Single or Double-sided models available
- Base module with loop feed terminal bar 350 MCM
- UL listed
REMOTE METERING PACKAGES AVAILABLE
CONSULT MANUFACTURER
((
(((
6
(((
((
Data subject to change without notice.
Application Information
RV Park Equipment
Today, most recreational vehicle parks provide power for their tenants. This application presents unique requirements including user safety,
rugged construction, weather protection, receptacle versatility, and attractiveness. Midwest Electric offers a complete line of power outlet products
for RV Park applications including standard power outlets, post mounted units, and metered models for both surface and pedestal units.
The 2002 National Electric Code Requires:
551-71. Type Receptacles Provided. Every recreational vehicle
site with electrical supply shall be equipped with at least one
20-ampere, 125-volt receptacle. A minimum of 5 percent of all
recreational vehicle sites with electrical supply, shall each be
equipped with a 50-ampere, 125/250 volt receptacle conforming to
the configuration as identified in Figure 551-46(c). These electrical
supplies shall be permitted to include additional receptacles that have
configurations in accordance with Section 551-81. A minimum of 70
percent of all recreational vehicle sites with electrical supply shall
each be equipped with a 30-ampere, 125-volt receptacle conforming
to Figure 551-46(c). This supply shall be permitted to include
additional receptacle configurations conforming to Section 551-81.
The remainder of all recreational vehicle sites with electrical supply
shall be equipped with one or more of the receptacle configurations
conforming to Section 551-81. Dedicated tent sites with a 15- or 20ampere electrical supply shall be permitted to be excluded when
determining the percentage of recreational vehicle sites with 30- or
50-ampere receptacles.
Additional receptacles shall be permitted for the connection of electrical
equipment outside the recreational vehicle within the recreational vehicle park.
Recreational Vehicle Parks are typically wired using either a loop-feed
or radial-feed system as illustrated on this page.
The most popular, and generally most economical, is the loop-feed
system where each feeder services a single power outlet.
Midwest Electric offers a complete line of power outlets for
recreational vehicle park application that meet the National Electrical
Code: standard power outlets, post mounted power outlets
(completely factory assembled and wired with loop-feed lugs in the
post) and metered power outlets (ring-type and ringless). Also listed
are surface mounted models with twin lugs per phase ideal for
overhead loop-feed systems.
Midwest offers both the traditional metallic equipment and the
ParkMate and ParkRanger series of non-metallic thermoplastic
units. Midwest has the unit for your unique application.
Figure 551-46(c)
Transformer
Transformer
All 125-volt, single-phase, 15- and 20-ampere receptacles shall have
listed ground-fault circuit-interrupter protection for personnel.
Figure 551-46(c). Configurations for grounding-type receptacles and
attachment plug caps used for recreational vehicle supply cords and
recreational vehicle lots.
551-77(b). Disconnecting Means. A disconnecting switch or circuit
breaker shall be provided in the site supply equipment for
disconnecting the power supply to the recreational vehicle.
Loop-Feed System
Radial-Feed System
Features and Benefits
Rugged Durability
• All-In-One construction for factory assured terminations
• Rolled edge door for cord protection
• Heavy (16 gauge) galvanized zinc-coated steel with
highest quality electro-deposition finish – resists corrosion
and fading
• Welded flange NEMA 3R construction for lasting service in
outdoor installations
Installation Ease
• All components are factory wired and assembled, reducing
installation time
• Door has stay-open position for user convenience
• All terminals accept copper or aluminum wire for added
installation flexibility
• Wide range of receptacle configurations
• Broad range of concentric knock-outs to accommodate
wiring needs
• All units with 12-2 Cu/Al equipment ground lug
• 10,000 AIC
Data subject to change without notice.
Posts
• Recreational vehicle park equipment available factory
assembled on a padmount or earth-burial post for
underground services.
• Factory wired from loop-feed lugs, located in the post to
receptacles, reducing installation time
• 200 Amp Loop-feed lugs have twin 2-250 MCM terminals
minimum per phase, Cu/Al (some models available up to
350 MCM)
• Rolled edge post bottoms to protect service cable
• Post door removable for installation ease
User Safety
• Listed by Underwriters Laboratories, a safety plus
• Padlock provision can prevent unauthorized entry
• Dead front construction prevents accidental contact
with live parts
7
Surface - Unmetered
RV Park Equipment
20 20
20
20
GFI
S
P
A
C
E
20 20
S
P
A
C
E
20 20
GFI GFI
S
P
A
C
E
S
P
20 20 AC
GFI GFI
E
5-20R2GFCI
5-20R2
(2) 5-20R2GFCI
(2) 5-20R2GFCI
(2) 5-20R2
(2) 5-20R2
A
U010C010
B
U010G
C
U011C010
D
U011CTL010
E
U011G
F
U011GTL
S
P
A
30 20 C
GFI GFI E
S
P
30 20 AC
GFI GFI E
(2) 5-20R2GFCI
R32U
R32U
G
U031C010
FIG. UL
LUG TYPE
BR32U
5-20R2
H
U040G
MODEL NUMBER
A
Y
STANDARD
U010C010
B
Y
STANDARD
U010G
30 20
R32U
5-20R2
I
U040GTL
S
P
A
C
E
30 20
5-20R2GFCI
J
U041C010
BR32U
S
P
A
C
E
S
P
A
C
E
30 20
GFI
5-20R2GFCI
R32U
K
U041CTL010
5-20R2
L
U041G
CIRCUIT
PROTECTION
AMP
VOLTS
5-20R2GFCI
CB120
20
120
B
6X9
Y
——
7
4
5-20R2
GFI120
20
120
B
6X9
Y
——
7
4
(2) CB120
SPACE CB120
70
120/240
P
6 X 14
Y
LC33N7
10
100
120/140
W
9 X 17
Y
LC33N1T
14
RECEPTACLES
WIRE CABINET
HUB
LOAD &
UNIT STD.
RANGE*
SIZE OPENING NEUTRAL BAR WT. PKG.
4
C
Y
STANDARD
U011C010
(2) 5-20R2GFCI
D
Y
LOOP FEED
U011CTL010
(2) 5-20R2GFCI
E
Y
STANDARD
U011G
(2) 5-20R2
(2) GFI120
SPACE CB120
70
120/240
P
6 X 14
Y
LC33N7
10
F
Y
LOOP FEED
U011GTL
(2) 5-20R2
(2) GFI120
SPACE CB120
100
120/240
W
9 X 17
Y
LC33N1T
14
1
G
Y
STANDARD
U031C010
R32U
(2) 5-20R2GFCI
CB130, (2) CB120 100
SPACE (2) CB120
120/240
AA
9 X 17
Y
LC55N1
16
1
H
Y
STANDARD
U040G
R32U
5-20R2
GFI130
GFI120
SPACE CB120
70
120/240
P
6 X 14
Y
LC33N7
10
4
I
Y
LOOP FEED
U040GTL
BR32U
5-20R2
GFI130
GFI120
SPACE CB120
100
120/240
W
9 X 17
Y
LC33N1T
14
1
J
Y
STANDARD
U041C010
R32U
5-20R2GFCI
CB130
CB120
SPACE CB120
70
120/240
P
6 x 14
Y
LC33N7
10
4
K
Y
LOOP FEED
U041CTL010
BR32U
5-20R2GFCI
CB130
CB120
SPACE CB120
100
120/240
W
9 x 17
Y
LC33N1T
14
1
L
Y
STANDARD
U041G
R32U
5-20R2
CB130
GFI120
SPACE CB120
70
120/240
P
6 x 14
Y
LC33N7
10
4
(2) CB120
SPACE CB120
1
4
* Wire Range Table on page 25
8
Data subject to change without notice.
Surface - Unmetered
RV Park Equipment
30 20
GFI
BR32U
S
P
A
C
E
50
5-20R2
A
U041GTL
14-50R
20
20
GFI
5-20R2GFCI
B
U055C010
50
S
P
30 20 AC
GFI GFI
E
50
14-50R
50 30 20
50
14-50R, BR32U,
5-20R2GFCI
5-20R2
D
U074GTL
C
U055G
S
P
A
C
E
S
P
20 AC
GFI
E
30
14-50R, BR32U,
5-20R2
E
U075CTL010
F
U075GTL
50
S
P
A
C
E
20 20
14-50R, (2) 5-20R2GFCI
G
U076C010
50A
20 30 30 20
S
P
A
C
E
50
20
S
P
A
C
E
S
P
A
C
E
SPACE
20
50
GFI
50A
30 30 20
30 20 20
30 30 20
GFI GFI
20A
30A
GFI
(2) BR32U
(2) BR32U
5-20R2GFCI
5-20R2GFCI
H
U131CTL010
FIG. UL
LUG TYPE
(2) BR32U
14-50R
5-20R2GFCI
I
U355C010
MODEL NUMBER
14-50R
5-20R2
J
U355G
BR32U
(2) 5-20R2
K
U412G
5-20R2GFCI
5-20R2
L
U611CTL010
RECEPTACLES
CIRCUIT
PROTECTION
AMP
VOLTS
M
U611GTL
R32U
(2) 14-50R
5-20R2GFCI
N
U775C010
WIRE CABINET
HUB
LOAD &
UNIT STD.
RANGE*
SIZE OPENING NEUTRAL BAR WT. PKG.
A
Y
LOOP FEED
U041GTL
BR32U
5-20R2
CB130
GFI120
SPACE CB120
100
120/240
W
9 x 17
Y
LC33N1T
14
1
B
Y
STANDARD
U055C010
14-50R
5-20R2GFCI
CB250
CB120
70
120/240
P
6 X 14
Y
LC33N7
10
4
14-50R
5-20R2
CB250
GFI120
70
120/240
P
6 X 14
Y
LC33N7
10
4
14-50R
R32U
5-20R2
14-50R
R32U
5-20R2GFCI
14-50R
R32U
5-20R2
CB250, GFI130
GFI120
SPACE CB120
CB250, CB130
CB120
SPACE CB120
CB250, CB130
GFI120
SPACE CB120
100
120/240
W
9 x 17
Y
LC55N1T
16
1
100
120/240
W
9 x 17
Y
LC55N1T
16
1
100
120/240
W
9 x 17
Y
LC55N1T
16
1
C
Y
STANDARD
U055G
D
Y
LOOP FEED
U074GTL
E
Y
LOOP FEED
U075CTL010
F
Y
LOOP FEED
U075GTL
G
Y
STANDARD
U076C010
14-50R
(2) 5-20R2GFCI
CB250
(2) CB120
SPACE CB120
100
120/240
U
9 x 17
Y
LC55N1
16
1
H
Y
LOOP FEED
U131CTL010
(2) 5-20R2GFCI
(2) BR32U
(2) CB120
(2) CB130
SPACE CB120
100
120/240
U
14 X 21
Y
LC55N1T
28
1
I
Y
STANDARD
U355C010
14-50R
5-20R2GFCI
CB250, CB120
(2 SPACES 100A MAX)
100
120/240
U
9 X 17
Y
LC55N1
16
1
J
Y
STANDARD
U355G
14-50R
5-20R2
CB250, GFI120
(2 SPACES 100A MAX)
100
120/240
U
9 X 17
Y
LC55N1
15
1
K
Y
STANDARD
U412G
BR32U
(2) 5-20R2
CB130
(2) GFI120
70
120/240
U
9 X 17
Y
LC33N1
16
1
L
Y
LOOP FEED
U611CTL010
(2) BR32U
5-20R2GFCI
(2) CB130
CB120
80
120/240
W
9 X 17
Y
LC33N1T
16
1
M
Y
LOOP FEED
U611GTL
(2) BR32U
5-20R2
(2) CB130
GFI120
80
120/240
W
9 X 17
Y
LC33N1T
15
1
N
Y
STANDARD
U775C010
(2) 14-50R
BR32U
5-20R2GFCI
(2) CB250T
CB130
CB120T
125
120/240
W
9 X 17
Y
——
15
1
* Wire Range Table on page 25
Data subject to change without notice.
9
Surface - Metered
RV Park Equipment
50
20
5-20R2GFCI
30 20
50
(2) 14-50R
R32U
A
M004C010
B
M031C010
R031C010
50
30 20
S
P
A
C
E
14-50R, BR32U
5-20R2GFCI
G
M075C010
R075C010
FIG. UL
MODEL NUMBER
RING TYPE
RINGLESS
A
Y
M004C010
B
Y
M031C010
BR32U
(2) 5-20R2GFCI
——
R031C010
50
S
P
A
C
E
S
P
A
GFI C
E
30 20
BR32U
5-20R2GFCI
30
50
20 20
14-50R, BR32U, 5-20R
14-50R, (2) 5-20R2GFCI
H
M075G
I
M076C010
R076C010
RECEPTACLES
CIRCUIT
PROTECTION
5-20R2GFCI
(2) 14-50R
(2) CB250
CB120
(2) 5-20R2GFCI
5-20R2
S
P
A
C
E
50
20
20
GFI
14-50R
14-50R
5-20R2GFCI
50
14-50R
20
S
P
A
C
E
S
P
A
C
E
14-50R
S
P
A
C
E
5-20R2
K
M355G
R355G
J
M355C010
AMP VOLTS
S
P
A
20 C
GFI E
50
5-20R2GFCI
5-20R2
F
M055G
R055G
E
M055C010
R055C010
D
M041G
R041G
C
M041C010
R041C010
S
P
20 AC
GFI E
50
WIRE CABINET
HUB
LOAD &
UNIT STD.
RANGE*
SIZE
OPENING NEUTRAL BAR WT. PKG.
100
120/240
AA
9 X 30
Y
LC55N1
26
1
(2) SPACE CB120 100
120/240
AA
9 X 30
Y
LC55N1
25
1
BR32U
5-20R2GFCI
CB130
CB120
SPACE CB120
100
120/240
AA
9 X 30
Y
LC33N1
24
1
BR32U
5-20R2
CB130
GFI120
SPACE CB120
100
120/240
AA
9 X 30
Y
LC33N1
25
1
14-50R
5-20R2GFCI
CB250
CB120
70
120/240
AA
9 X 30
Y
LC33N1
25
1
14-50R
5-20R2
CB250
GFI120
70
120/240
AA
9 X 30
Y
LC33N1
25
1
C
Y
M041C010
R041C010
D
Y
M041G
R041G
E
Y
M055C010
R055C010
F
Y
M055G
R055G
G
Y
M075C010
R075C010
14-50R
BR32U
5-20R2GFCI
CB250, CB130
CB120
SPACE CB120
100
120/240
AA
9 X 30
Y
LC55N1
25
1
H
Y
M075G
——
14-50R
BR32U
5-20R2
CB250, CB130
GFI120
SPACE CB120
100
120/240
AA
9 X 30
Y
LC55N1
25
1
I
Y
M076C010
14-50R
(2) 5-20R2GFCI
CB250
(2) CB120
SPACE CB120
90
120/240
AA
9 X 30
Y
LC55N1
26
1
J
Y
M355C010
14-50R
5-20R2GFCI
CB250, CB120
(2) SPACE CB120 100
120/240
AA
9 X 30
Y
LC55N1
25
1
K
Y
M355G
14-50R
5-20R2
CB250
GFI120
100
(2) SPACE CB2100
120/240
AA
9 X 30
Y
LC55N1
25
1
R076C010
——
R355G
* Wire Range Table on page 25
10
Data subject to change without notice.
Pedestal - Unmetered
RV Park Equipment
50
20
20 20
50
S
P
A
C
E
S
P
A
C
E
20 20
GFI GFI
POST
POST
POST
(2) 14-50R, 5-20R2GFCI
(2) 5-20R2GFCI
(2) 5-20R2
A
U004CP6010
U004CP4010
B
U011CP6010
U011CP4010
C
U011GP6
U011GP4
S
P
A
GFI GFI C
E
30 20
POST
POST
30 20
R32U
GFI
5-20R2
D
U040GP6
U040GP4
R32U
S
P
A
C
E
30 20
S
P
A
C
E
30 20
GFI
POST
R32U
5-20R2GFCI
E
U040GP6010
S
P
A
C
E
POST
5-20R2GFCI
F
U041CP6010
U041CP4010
R32U
5-20R2
G
U041GP6
U041GP4
MAIN
30 30 20
50
GFI
POST
14-50R
20
POST
5-20R2GFI
R32U
5-20R2
I
U043GP6
H
U042GP6
14-50R
5-20R2GFCI
J
U055CP6010
U055CP4010
MODEL NUMBER
FIG. UL
A
Y
EARTH BURIAL
PADMOUNT
U004CP6010
U004CP4010 %
RECEPTACLES
50
S
P
A
C
E
30 20
50
POST
30 20
S
P
A
C
E
50
K
U075CP6010
U075CP4010
CIRCUIT
AMP
PROTECTION
14-50R, BR32U, 5-20R2GFCI
14-50R, BR32U, 5-20R2
M
U075GP6
U075GP4
L
U075CP6010D
VOLTS
GFI
S
P
A
C
E
POST
POST
14-50R, BR32U, 5-20R2GFCI
30 20
50
30 20
GFI GFI
S
P
A
C
E
POST
14-50R, BR32U, 5-20R2GFCI
N
U075GP6019
WIRE CABINET
HUB
LOAD &
UNIT STD.
RANGE* SIZE OPENING NEUTRAL BAR WT. PKG.
(2) 14-50R
5-20R2GFCI
(2) CB250
CB120
100
120/240
T2
9PT
N
LC55N1
47
1
(2) 5-20R2GFCI
(2) CB120
SPACE CB120
70
120/240
T2
6PT
N
LC33N7
32
1
B
Y
U011CP6010
U011CP4010
C
Y
U011GP6
U011GP4
(2) 5-20R2
(2) GFI120
SPACE CB120
70
120/240
T2
6PT
N
LC33N7
32
1
D
Y
U040GP6
U040GP4
R32U
5-20R2
GFI130, GFI120,
SPACE CB120
70
120/240
T2
9PT
N
LC33N7
32
1
——
R32U
5-20R2GFCI
GFI130, CB120,
SPACE CB120
70
120/240
T2
9PT
N
LC33N7
32
1
R32U
5-20R2GFCI
70
120/240
T2
6PT
N
LC33N7
32
1
70
120/240
T2
6PT
N
LC33N7
32
1
E
Y
U040GP6010
F
Y
U041CP6010 % + U041CP4010 % +
G
Y
U041GP6
U041GP4
R32U
5-20R2
CB130
CB120
SPACE CB120
CB130
GFI120
SPACE CB120
H
Y
U042GP6
——
R32U
5-20R2
GFI130 MAIN
CB130, CB120
30
120
T2
6PT
N
LC33N7
32
1
I
Y
U043GP6
——
R32U
5-20R2
CB130 MAIN
CB130
GFI120
70
120/240
T2
6PT
N
LC33N7
32
1
J
Y
U055CP6010
U055CP4010
K
Y
U075CP6010 %+ U075CP4010 %
L
Y
U075CP6010D P+
M
Y
U075GP6
N
Y
U075GP6019
——
U075GP4
——
14-50R
5-20R2GFCI
14-50R
BR32U
5-20R2GFCI
CB250, CB120
70
120/240
T2
6PT
N
LC33N7
32
1
CB250, CB130
CB120
SPACE CB120
100
120/240
T2
9PT
N
LC55N1
47
1
14-50R
BR32U
5-20R2GFCI
CB250, CB130
CB120
SPACE CB120
100
120/240
T2
9PT
N
LC55N1
47
1
100
120/240
T2
9PT
N
LC55N1
47
1
100
120/240
T2
9PT
N
LC55N1
47
1
14-50R, BR32U CB250, CB130
5-20R2
GFI120
14-50R, BR32U CB250, GFI130
5-20R2
GFI120
% Available with factory-installed TV/Telephone, replace “010 with “031”
P Post depth dimension is non-standard (4-3/8")
+ Available w/350 MCM loop lugs, replace “010” with “039”
Data subject to change without notice.
Tv/Tel model diagrams on page 19
* Wire Range Table on page 25
11
Pedestal - Unmetered
RV Park Equipment
S
P
A
C
E
30 30 20 20
50
S
P
A
GFI C
E
(2) BR32U, (2) 5-20R2GFCI
14-50R, R32U, 5-20R2GFCI
A
U131CP6010
B
U175CP6HP010
14-50R
5-20R2
C
U355GP6
MODEL NUMBER
EARTH BURIAL
PADMOUNT
RECEPTACLES
50
30 20 20
30 30 20
30 20 20
50
20
30
GFI GFI
POST
POST
POST
FIG. UL
S
P
A
C
E
20
BR32U
(2) 5-20R2GFCI
POST
BR32U
(2) BR32U
(2) 5-20R2
E
U412GP6
D
U412CP6010
CIRCUIT
PROTECTION
POST
AMP
VOLTS
5-20R2GFCI
POST
BR32U
(2) 14-50R, 5-20R2GFCI
G
U775CP6010
U775CP4010
F
U611CP6010
U611CP4010
WIRE CABINET
HUB
LOAD &
UNIT STD.
RANGE* SIZE OPENING NEUTRAL BAR WT. PKG.
A
Y
U131CP6010
——
(2) BR32U
(2) 5-20R2GFCI
(2) CB130, (2) CB120 100
SPACE CB120
120/240
T2
14PT
N
LC55N1
47
1
B
Y
U175CP6HP010
——
W
14PT
N
——
89
1
Y
U355GP6
——
CB2100 MAIN, CB250 100
CB130, CB120
CB250, GFI120
(2) SPACE CB120 100
120/240
C
14-50R, BR32U
5-20R2GFCI
14-50R
5-20R2
120/240
T2
9PT
N
LC55N1
47
1
D
Y
U412CP6010
——
BR32U
(2) 5-20R2GFCI
CB130
(2) CB120
70
120/240
T2
9PT
N
LC33N1
47
1
E
Y
U412GP6
——
BR32U
(2) 5-20R2
CB130
(2) GFI120
70
120/240
T2
9PT
N
LC33N1
51
1
F
Y
U611CP6010
U611CP4010
(2) BR32U
5-20R2GFCI
(2) CB130
CB120
80
120/240
T2
9PT
N
LC33N1
47
1
G
Y
U775CP6010
U775CP4010
(2) 14-50R
BR32U
5-20R2GFCI
(2) CB250T
CB130
CB120T
125
120/240
T2
9PT
N
——
97
1
* Wire Range Table on page 25
PLK50 Replacement deadfront kit with 50-Amp lockout feature for all U075- or M075-series units. Line Drawing on
page 34. Consult Manufacturer for details.
12
Data subject to change without notice.
Pedestal - Unmetered
RV Park Equipment
50
20
50
50
20
S
P
20 20 AC
GFI GFI E
50
S
P
20 20 AC
GFI GFI E
30 20
POST
POST
5-20R2GFCI
(2) 14-50R
50
50
GFI
20
50
GFI
30
30 20
S
P
A
C
E
50
30 20
S
P
A
C
E
50
30
S
P
20 AC
GFI E
MAIN
MAIN
30 30 20
30 30 20
GFI
GFI
POST
R32U, 5-20R2
R32U, 5-20R2
D
U041GB6
U041GB4
S
P
A
GFI C
E
30 20
50
S
P
A
GFI C
E
30 30 20
30 30 20
POST
(2) BR32U, 5-20R2GFCI
14-50R, BR32U, 5-20R2
H
U075GB6
G
U075CB6010
U075CB4010
E
U042GB6
30 20
POST
14-50R, BR32U, 5-20R2GFCI
F
U055GB6
S
P
20 AC
GFI E
POST
C
U041CB6010
U041CB4010
POST
POST
14-50R, 5-20R2
30 20
R32U, 5-20R2GFCI
B
U011GB6
U011GB4
20
S
P
A
C
E
POST
(2) 5-20R2
A
U004CB6010
U004CB4010
S
P
A
C
E
I
U611CB6010
U611CB4010
Back-to-Back
FIG. UL
MODEL NUMBER
EARTH BURIAL
PADMOUNT
RECEPTACLES
(PER SIDE)
CIRCUIT
PROTECTION
(PER SIDE)
AMP
VOLTS
(2) 14-50R
5-20R2GFCI
(2) CB250
CB120
100
120/240
S
9PT
N
LC55N1
62
1
(2) 5-20R2
(2) GFI120
SPACE CB120
70
120/240
T2
6PT
N
LC33N7
47
1
R32U
5-20R2GFCI
CB130
CB120
SPACE CB120
70
120/240
T2
6PT
N
LC33N7
47
1
WIRE CABINET
HUB
LOAD &
UNIT STD.
RANGE* SIZE OPENING NEUTRAL BAR WT. PKG.
A
Y
U004CB6010
U004CB4010
B
Y
U011GB6
U011GB4
C
Y
U041CB6010
U041CB4010
D
Y
U041GB6
U041GB4
R32U
5-20R2
CB130
GFI120
SPACE CB120
70
120/240
T2
6PT
N
LC33N7
47
1
E
Y
U042GB6
——
R32U
5-20R2
GFI130 MAIN
(2) CB120
30
120
T2
6PT
N
LC33N7
47
1
——
14-50R
5-20R2
CB250
GFI120
70
120/240
T2
6PT
N
LC33N7
47
1
14-50R
BR32U
5-20R2GFCI
CB250, CB130
CB120
SPACE CB120
100
120/240
S
9PT
N
LC55N1
62
1
14-50R
BR32U
5-20R2
CB250, CB130
GFI120
SPACE CB120
100
120/240
S
9PT
N
LC55N1
62
1
(2) BR32U
5-20R2GFCI
(2) CB130
CB120
80
120/240
T2
9PT
N
LC33N1
62
1
F
Y
U055GB6
G
Y
U075CB6010 % U075CB4010 %
H
Y
U075GB6
I
Y
U611CB6010
——
U611CB4010
% Available with added factory-installed TV/Telephone. Replace “010” with “031” See page 19
* Wire Range Table on page 25
Data subject to change without notice.
13
Pedestal - Metered
RV Park Equipment
50
20
30 20
50
S
P
A
C
E
S
P
A
GFI C
E
50
30 20
POST
POST
POST
BR32U, 5-20R2GFCI
BR32U, 5-20R2
B
M041CP6010
M041CP4010
R041CP6010
50
GFI
(2) 14-50R, 5-20R2GFCI
A
M004CP6010
20
C
M041GP6
M041GP4
R041GP6
S
P
A
C
E
POST
POST
14-50R
30 20
5-20R2
14-50R,BR32U,5-20R2GFCI
E
M075CP6010
M075CP4010
R075CP6010
R075CP4010
D
M055GP6
Earth Burial
FIG. UL
MODEL NUMBER
RING TYPE
RINGLESS
RECEPTACLES
A
Y
M004CP6010
——
(2) 14-50R
5-20R2GFCI
B
Y
M041CP6010
R041CP6010
BR32U
5-20R2GFCI
C
Y
M041GP6
R041GP6
BR32U
5-20R2
D
Y
M055GP6
——
E
Y
M075CP6010 % R075CP6010 %
CIRCUIT
PROTECTION
(2) CB250
CB120
CB130
CB120
SPACE CB120
AMP VOLTS
WIRE CABINET
HUB
LOAD &
UNIT STD.
RANGE*
SIZE
OPENING NEUTRAL BAR WT. PKG.
100
120/240
T2
9PT
N
LC88X1
48
1
100
120/240
T2
9PT
N
LC33N1
53
1
CB130
GFI120
SPACE CB120
100
120/240
T2
9PT
N
LC33N1
59
1
14-50R
5-20R2
CB250
GFI120
70
120/240
T2
9PT
N
LC33N1
59
1
14-50R
BR32U
5-20RGFCI
CB250, CB130
CB120
SPACE CB120
100
120/240
T2
9PT
N
LC55N1
59
1
Padmount
B
Y
M041CP4010
——
BR32U
5-20R2GFCI
CB130
CB120
SPACE CB120
100
120/240
T2
9PT
N
LC33N1
53
1
C
Y
M041GP4
——
BR32U
5-20R2
CB130
GFI120
100
120/240
T2
9PT
N
LC33N1
59
1
14-50R
BR32U
5-20RGFCI
CB250, CB130
CB120
SPACE CB120
100
120/240
T2
9PT
N
LC55N1
59
1
E
Y
M075CP4010
R075CP4010
% Available with added factory-installed TV/Telephone in post. Replace “010” with “031”.
* Wire Range Table on page 25
14
Data subject to change without notice.
Pedestal - Metered
RV Park Equipment
SPACE
50
S
P
A
GFI C
E
S
P
A
C
E
30 20
S
P
A
C
E
20
20
50
50
GFI
S
P
A
C
E
SPACE
S
P
A
C
E
50
30
SPACE
SPACE
BR32U
POST
POST
POST
14-50R
5-20R2
14-50R, 5-20R2GFCI
14-50R
B
M355CP6010
R355CP6010
A
M075GP6
R075GP6
M075GP4
R32U
C
M355GP6
R355GP6
M355GP4
50
20
30
20 GFI
SPACE
POST
POST
5-20R2
50
50
SPACE
5-20R2
14-50R
POST
14-50R
E
M655GP6
D
M358CP6
BR32U,(2)14-50R,5-20R2GFCI
F
M775CP6010
Earth Burial
FIG. UL
MODEL NUMBER
RING TYPE
RINGLESS
A
Y
M075GP6
R075GP6
B
Y
M355CP6010
R355CP6010 %
C
Y
M355GP6 +
R355GP6
D
Y
M358CP6
——
RECEPTACLES
CIRCUIT
PROTECTION
14-50R
BR32U
5-20R2
CB250, CB130
GFI120
SPACE CB120
100
120/240
T2
9PT
N
LC55N1
59
1
14-50R
5-20R2GFCI
CB250
CB120
(2) SPACE
100
120/240
T2
9PT
Y
LC55N1
59
1
14-50R
5-20R2
CB250
GFI120
SPACE CB2100
100
120/240
T2
9PT
N
LC55N1
59
1
R32U, 14-50R
CB250, CB130
100
120/240
T2
9PT
N
LC55N1
53
1
200
120/240
T2
14PT
N
LC1212PC
89
1
AMP VOLTS
WIRE CABINET
HUB
LOAD &
UNIT STD.
RANGE*
SIZE
OPENING NEUTRAL BAR WT. PKG.
E
Y
M655GP6
——
14-50R
5-20R2
CB250, GFI120
SPACE CB2200B
SPACE (5) CB120
200A. MAX
F
Y
M775CP6010
——
(2) 14-50R
BR32U
5-20R2GFCI
(2) CB250T
CB130
CB120T
125
120/240
T2
9PT
N
——
59
1
Padmount
A
Y
M075GP4
——
14-50R
BR32U
5-20R2
CB250, CB130
GFI120
SPACE CB120
100
120/240
T2
9PT
N
LC55N1
59
1
C
Y
M355GP4
——
14-50R
5-20R2
CB250
GFI120
SPACE CB2100
100
120/240
T2
9PT
N
LC55N1
59
1
% Available with factory-installed TV/Telephone in post. Replace “010” with “031”.
+ Available with Penta-head kit installed, 9" or 14" post. Order as M355GP6028. Consult Manufacturer.
* Wire Range Table on page 25
Data subject to change without notice.
15
Pedestal - Metered
RV Park Equipment
S
P
A
C
E
S
P
A
GFI C
E
30 20
POST
S
P
A
GFI C
E
30 20
50
5-20R2
14-50R
POST
BR32U
5-20R2GFCI
S
P
A
GFI C
E
20
S
P
A
C
E
50
S
P
A
GFI C
E
20
S
P
A
C
E
14-50R
5-20R2
E
M355GB6
Back-to-Back
SPACE
SPACE
SPACE
SPACE
SPACE
SPACE
SPACE
SPACE
SPACE
SPACE
SPACE
S
P
A
C
E
50
S
P
A
GFI C
E
30 20
SPACE
SPACE
SPACE
SPACE
SPACE
SPACE
14-50R
50
S
P
A
GFI C
E
30 20
POST
5-20R2GFCI
14-50R
BR32U
5-20R2
D
M075GB6
R075GB6
50A
50A
20A
30A
SPACE
POST
POST
30 20
C
M075CB6010
M075CB4010
R075CB6010
20
50
50
BR32U
B
M041GB6
R041GB6
50
A
M041CB6010
S
P
A
C
E
POST
20
BR32U
30 20
50
30 20
GFI
S
P
A
C
E
GFI
30 20
50A
50A
20A
30A
POST
5-20R2
BR32U
14-50R
F
M655GB6
14-50R
5-20R2GFCI
G
M775CB6010
Earth Burial
MODEL NUMBER
FIG. UL
RING TYPE
RINGLESS
——
RECEPTACLES
(PER SIDE)
CIRCUIT
PROTECTION
(PER SIDE)
AMP
VOLTS
BR32U
5-20R2GFCI
CB130, CB120
SPACE CB120
100
120/240
S
9PT
N
LC33N1
82
1
BR32U
5-20R2
CB130, GFI120
SPACE CB120
100
120/240
S
9PT
N
LC33N1
82
1
14-50R
BR32U
5-20R2GFCI
CB250, CB130
CB120
SPACE CB120
100
120/240
S
9PT
N
LC55N1
82
1
14-50R
BR32U
5-20R2
CB250, CB130
GFI120
SPACE CB120
100
120/240
S
9PT
N
LC55N1
82
1
WIRE CABINET
HUB
LOAD &
UNIT STD.
RANGE* SIZE OPENING NEUTRAL BAR WT. PKG.
A
Y
M041CB6010
B
Y
M041GB6
R041GB6
C
Y
M075CB6010 %
R075CB6010
D
Y
M075GB6
R075GB6
E
Y
M355GB6
——
14-50R
5-20R2
CB250
GFI120
100
(2) SPACE CB2100
120/240
S
9PT
N
LC55N1
82
1
F
Y
M655GB6
——
14-50R
5-20R2
CB250
GFI120
(9) SPACE CB120
200
120/240
S
14PT
N
LC1212PC
N1200A4
80
1
G
Y
M775CB6010
——
(2) 14-50R
BR32U
5-20R2GFCI
(2) CB250T
CB130
CB120T
125
120/240
S
9PT
N
——
82
1
——
14-50R
BR32U
5-20R2GFCI
CB250, CB130
CB120
SPACE CB120
100
120/240
S
9PT
N
LC55N1
82
1
Padmount
C
Y
M075CB4010
% Available with factory-installed TV/Telephone in post. Replace “010” with “031”.
*
Wire Range Table on page 25
16
Data subject to change without notice.
Lighted RV
RV Park Equipment
30 20
BR32U
50
5-20R2GFCI
BR54U
A
U041CTLL10
Surface - Unmetered
FIG. UL
S
P
A
C
E
30 20
BR32U
S
P
A
C
E
5-20R2GFCI
B
U075CTLL10
LUG TYPE
MODEL NUMBER
RECEPTACLES
CIRCUIT
PROTECTION
AMP
VOLTS
WIRE CABINET
HUB
LOAD &
UNIT STD.
RANGE*
SIZE OPENING NEUTRAL BAR WT. PKG.
A
Y
LOOP FEED
U041CTLL10
BR32U
5-20R2GFCI
CB130
CB120
100
120/240
W
9 X 17
N
LC33N1T
14
1
B
Y
LOOP FEED
U075CTLL10
BR54U
BR32U
5-20R2GFCI
CB250, CB130
CB120
SPACE
100
120/240
W
9 x 17
N
LC55N1T
16
1
30 20
S
P
A
C
E
50
MODEL NUMBER
EARTH BURIAL
PADMOUNT
SPACE
14-50R
C
M041CP6L10
M041CP4L10
Pedestal - Metered
FIG. UL
5-20R2GFCI
RECEPTACLES
S
P
A
C
E
POST
POST
BR32U
30 20
BR32U
5-20R2GFCI
D
M075CP6L10
M075CP4L10
CIRCUIT
WIRE CABINET
HUB
LOAD &
UNIT STD.
AMP VOLTS
PROTECTION
RANGE*
SIZE
OPENING NEUTRAL BAR WT. PKG.
C
Y
M041CP6L10
M041CP4L10 %
BR32U
5-20R2GFCI
SPACE
CB130
CB120
SPACE
100
120/240
T2
9PT
Y
LC33N1
50
1
D
Y
M075CP6L10 %+ M075CP4L10 %
14-50R
BR32U
5-20R2GFCI
CB250, CB130
CB120
SPACE CB120
100
120/240
T2
9PT
Y
LC55N1
59
1
+ Available with 350 MCM lug, replace “L10” with “L39”
% Available with factory-installed TV/Telephone, replace “L10” with “L31”
* Wire Range Table on page 25
= Light Socket Assembly. Photocell and 7-watt incandescent lamp included in separate box - GE # 265A5262P39.
Data subject to change without notice.
17
Lighted RV
RV Park Equipment
Pedestal - Unmetered
30 20
S
P
A
C
E
30 20
S
P
A
C
E
30 20
S
P
A
C
E
30 20
GFI
S
P
A
C
E
POST
S
P
A
C
E
50
30 20
S
P
A
C
E
50
30 20
S
P
A
C
E
50
30 20
S
P
A
C
E
POST
5-20R2GFCI
A
U041CB6L10
U041CB4L10
R32U
5-20R2GFCI
R32U
B
U041CP6L10
U041CP4L10
EARTH BURIAL
PADMOUNT
5-20R2
POST
POST
BR54U
C
U041GP6L
U041GP4L
MODEL NUMBER
FIG. UL
30 20
POST
POST
R32U
50
BR32U
5-20R2GFCI
D
U075CB6L10
U075CB4L10
RECEPTACLES
CIRCUIT
PROTECTION
AMP
VOLTS
BR54U
BR32U
5-20R2GFCI
E
U075CP6L10
U075CP4L10
BR54U
BR32U
5-20R2
F
U075GP6L
U075GP4L
WIRE CABINET
HUB
LOAD &
UNIT STD.
RANGE* SIZE OPENING NEUTRAL BAR WT. PKG.
A
Y
U041CB6L10
U041CB4L10
R32U
5-20R2GFCI
CB130, CB120
SPACE CB120
100
120/240
T2
6PT
N
LC33N1
42
1
B
Y
U041CP6L10
U041CP4L10
R32U
5-20R2GFCI
CB130, CB120
SPACE CB120
100
120/240
T2
6PT
N
LC33N1
30
1
C
Y
U041GP6L
U041GP4L
R32U
5-20R2
CB130
GFI120
SPACE CB120
100
120/240
T2
6PT
N
LC33N1
30
1
D
Y
U075CB6L10
U075CB4L10
BR54U
BR32U
5-20R2GFCI
CB250, CB130
CB120
SPACE CB120
100
120/240
S
9PT
N
LC55N1
62
1
E
Y
U075CP6L10 %
U075CP4L10%
BR54U
BR32U
5-20R2GFCI
CB250, CB130
CB120
SPACE CB120
100
120/240
T2
9PT
N
LC55N1
36
1
F
Y
U075GP6L
U075GP4L
BR54U
BR32U
5-20R2
CB250, CB130
GFI120
SPACE CB120
100
120/240
T2
9PT
N
LC55N1
62
1
% Available with factory-installed TV/Telephone, replace “L10” with “L31”
* Wire Range Table on page 25
= Light Socket Assembly. Photocell and 7-watt incandescent lamp included.
18
Data subject to change without notice.
TV/Tel Unmetered Units
RV Park Equipment
U004CP4031-
U075CP4031-
U075CB6031-
Unmetered
Unmetered
Unmetered
A
41-1/8”
A
65-1/8”
A
B
3-1/8”
B
4-1/2”
B
4-1/2”
C
9”
C
9”
C
9”
D
19-1/2”
D
24”
D
19”
E
16”
E
41-1/8”
E
14-1/2”
F
19-1/2”
F
5-1/4”
G
20”
U041CP6031-
see pg. 11
see pg. 13
Unmetered
Unmetered
Unmetered
A
41-1/8”
A
40-1/2”
A
B
3-3/8”
B
4-1/2”
B
3-3/8”
C
9”
C
9”
C
9”
D
19-1/2”
D
19”
D
24”
E
16”
E
7”
E
41-1/8”
F
19-1/2”
G
16”
U075CP4L31-
see pg. 11
see pg. 13
Data subject to change without notice.
U075CB4031-
see pg. 11
40-1/2”
U075CP6L31-
see pg. 18
Unmetered
Unmetered
A
65-1/8”
A
65-1/8”
B
4-1/2”
B
3-3/8”
C
9”
C
9”
D
24”
D
24”
E
41-1/8”
E
41-1/8”
F
19-1/2”
F
19-1/2”
G
15”
G
16”
H
5-1/4”
U075CP6031-
65-1/8”
see pg. 18
Flip-Cover for TV/Tel is
standard with padlock
provision.
see pg. 11
19
Technical Data
RV Metallic
REPLACEMENT PARTS
MODEL
NUMBER
M004C010
M004CP6010
M031C010
M041C010
M041CB6010
M041CP4010
M041CP4L10
M041CP4L31
M041CP6010
M041CP6L10
M041G
M041GB6
M041GP4
M041GP6
M055C010
M055G
M055GP6
M075C010
M075CB4010
M075CB6010
M075CB6031
M075CP4010
M075CP4L10
M075CP4L31
M075CP6010
M075CP6031
M075CP6L10
M075CP6L31
M075CP6L39
M075G
M075GB6
M075GP4
M075GP6
M076C010
M355C010
M355CP6010
M355G
M355GB6
M355GP4
M355GP6
M355GP6028
M358CP6
M655GB6
M655GP6
M775CB6010
M775CP6010
R031C010
R041C010
R041CP6010
R041G
R041GB6
R041GP6
CABINET DIMENSIONS **
METER *
SOCKET
POST
LUGS
CABINET
SIZE
pages 23-24
MSM100930
MSM100P9
MSM100930
MSM100930
A
MSM100P9
MSM100P9
MSM100P9
MSM100P9
MSM100P9
MSM100930
A
MSM100P9
MSM100P9
MSM100930
MSM100930
MSM100P9
MSM100930
A
A
A
MSM100P9
MSM100P9
MSM100P9
MSM100P9
MSM100P9
MSM100P9
MSM100P9
MSM100P9
MSM100930
A
MSM100P9
MSM100P9
MSM100930
MSM100930
MSM100P9
MSM100930
A
MSM100P9
MSM100P9
MSM100P9
MSM100P9
MW200M
MW200M
A
MSM100P9
MSR100930
MSR100930
MSR100P9
MSR100930
B
MSR100P9
——
LT100S300
——
——
LT100B350
LT100S300
LT100S250
LT100S300
LT100S300
LT100S250
——
LT100B350
LT100S250
LT100S300
——
——
LT100S250
——
LT100B350
LT100B350
LT100B350
LT100S300
LT100S300
LT100S300
LT100S300
LT100S300
LT100S300
LT100S300
LT100S350
——
LT100B350
LT100S250
LT100S250
——
——
LT100S300
——
LT100B350
LT100S300
LT100S300
LT100S250
LT100B350
LT200B350
LT200S350
LT100B350
LT100S250
——
——
LT100S300
——
LT100B350
LT100S250
9 X 30
9PT
9 X 30
9 X 30
9PT
9PT
9PT
9PT
9PT
9PT
9 X 30
9PT
9PT
9PT
9 X 30
9 X 30
9PT
9 X 30
9PT
9PT
9PT
9PT
9PT
9PT
9PT
9PT
9PT
9PT
9PT
9 X 30
9PT
9PT
9PT
9 X 30
9 X 30
9PT
9 X 30
9PT
9PT
9PT
9PT
9PT
14PT
14PT
9PT
9PT
9 X 30
9 X 30
9PT
9 X 30
9PT
9PT
ENCLOSURE
STYLE
page 23
HEIGHT
A
B
C
KNOCKOUT
FIGURE
page 23
B
B
B
B
B
B
B
B
B
B
B
B
B
B
-
30"
30"
30"
30"
30"
30"
30"
30"
30"
30"
30"
30"
30”
30"
-
9-3/4"
9-3/4"
9-3/4"
9-3/4"
9-3/4"
9-3/4"
9-3/4"
9-3/4"
9-3/4"
9-3/4"
9-3/4"
9-3/4"
9-3/4”
9-3/4"
-
5-3/16"
5-3/16"
5-3/16"
5-3/16"
5-3/16"
5-3/16"
5-3/16"
5-3/16"
5-3/16"
5-3/16"
5-3/16"
5-3/16"
5-3/16”
5-3/16"
-
2
2
2
2
2
2
2
2
2
2
2
2
2
2
-
WIDTH
DEPTH
A Front (Inline Side) MSM100P9, Back (Powerhead side) MSM100HP
B Front (Inline Side) MSR100P9, Back (Powerhead side) MSR100HP
** For Post Cabinet Sizes and Dimensions see page 24.
20
Data subject to change without notice.
Technical Data
RV Metallic
REPLACEMENT PARTS
MODEL
NUMBER
R055C010
R055G
R075C010
R075CB6010
R075CP4010
R075CP6010
R075CP6031
R075GB6
R075GP6
R076C010
R355CP6010
R355CP6031
R355G
R355GP6
U004CB4010
U004CB6010
U004CP4010
U004CP4031
U004CP6010
U010C010
U010G
U011C010
U011CP4010
U011CP6010
U011CTL010
U011G
U011GB4
U011GB6
U011GP4
U011GP6
U011GTL
U031C010
U040G
U040GP4
U040GP6
U040GP6010
U040GTL
U041C010
U041CB4010
U041CB4L10
U041CB6010
U041CB6L10
U041CP4010
U041CP4031
U041CP4039
U041CP4L10
U041CP6010
U041CP6031
U041CP6039
U041CP6L10
U041CTL010
U041CTLL10
U041G
U041GB4
U041GB6
U041GP4
CABINET DIMENSIONS **
METER
SOCKET
POST
LUGS
CABINET
SIZE
pages 23-24
MSR100930
MSR100930
MSR100930
MSR100P9
MSR100P9
MSR100P9
MSR100P9
B
MSR100P9
MSR100930
MSR100P9
MSR100P9
MSR100930
MSR100P9
——
——
——
——
——
——
——
——
——
——
——
——
——
——
——
——
——
——
——
——
——
——
——
——
——
——
——
——
——
——
——
——
——
——
——
——
——
——
——
——
——
——
——
——
——
LT100B350
LT100S250
LT100S300
LT100S300
LT100B350
——
——
——
——
——
——
LT100B350
LT100B350
LT100S250
LT100S300
LT100S300
——
——
——
LT100S300
LT100S300
——
–—
LT100B250
LT100B250
LT100S250
LT100S300
——
——
——
LT100S250
LT100S300
LT100S250
——
——
LT100B250
LT100B250
——
LT100B250
LT100S250
LT100S250
LT100S350
LT100S250
LT100S300
LT100S250
LT100S350
LT100S300
——
——
——
LT100B250
LT100B250
LT100S300
9 X 30
9 X 30
9 X 30
9PT
9PT
9PT
9PT
9PT
9PT
9 X 30
9PT
9PT
9 X 30
9PT
9PT
9PT
9PT
9PT
9PT
6X9
6X9
6 X 14
6PT
6PT
9 X 17
6 X 14
6PT
6PT
6PT
6PT
9 X 17
9 X 17
6 X 14
6PT
6PT
6PT
9 X 17
6 X 14
6PT
6PT
6PT
6PT
6PT
6PT
6PT
6PT
6PT
6PT
6PT
6PT
9 X 17
9 X 17
6 X 14
6PT
6PT
6PT
ENCLOSURE
STYLE
page 23
HEIGHT
A
B
C
KNOCKOUT
FIGURE
page 23
B
B
B
-
30"
30"
30"
-
9-3/4"
9-3/4"
9-3/4"
-
5-3/16"
5-3/16"
5-3/16"
-
2
2
2
-
B
B
A
A
A
A
A
A
A
A
A
A
A
A
A
-
30"
30"
9-1/8"
9-1/8"
14-3/8"
17-3/8"
14-3/8"
17-3/8"
17-3/8"
14-3/8"
17-3/8"
14-3/8"
17-3/8"
17-3/8"
14-3/8"
-
9-3/4"
9-3/4"
7-1/4"
7-1/4"
7-1/4"
9-3/4"
7-1/4"
9-3/4"
9-3/4"
7-1/4"
9-3/4"
7-1/4"
9-3/4"
9-3/4"
7-1/4"
-
5-3/16"
5-3/16"
5-3/16"
5-3/16"
5-3/16"
5-3/16"
5-3/16"
5-3/16"
5-3/16"
5-3/16"
5-3/16"
5-3/16"
5-3/16"
5-3/16"
5-3/16"
-
2
2
1
1
1
2
1
2
2
1
2
1
2
2
1
-
WIDTH
DEPTH
B - Front (Inline Side) MSR100P9, Back (Powerhead side) MSR100HP
** For Post Cabinet Sizes and Dimensions see page 24.
Data subject to change without notice.
21
Technical Data
RV Metallic
REPLACEMENT PARTS
MODEL
NUMBER
U041GP4L
U041GP6
U041GP6L
U041GTL
U042GB6
U042GP6
U043GP6
U055C010
U055CP4010
U055CP6010
U055G
U055GB6
U074GTL
U075CB4010
U075CB4031
U075CB4L10
U075CB6010
U075CB6031
U075CB6L10
U075CP4010
U075CP4031
U075CP4L10
U075CP4L31
U075CP6010
U075CP6010D
U075CP6031
U075CP6039
U075CP6039D
U075CP6L10
U075CP6L31
U075CTL010
U075CTLL10
U075GB6
U075GP4
U075GP4L
U075GP6
U075GP6019
U075GP6L
U075GTL
U076C010
U131CP6010
U131CTL010
U175CP6HP010
U355C010
U355G
U355GP6
U412CP6010
U412G
U412GP6
U611CB4010
U611CB6010
U611CP4010
U611CP6010
U611CTL010
U611GTL
U775C010
U775CP4010
U775CP6010
CABINET DIMENSIONS **
METER
SOCKET
POST
LUGS
CABINET
SIZE
pages 23-24
——
——
——
——
——
——
——
——
——
——
——
——
——
——
——
——
——
——
——
——
——
——
——
——
——
——
——
——
——
——
——
——
——
——
——
——
——
——
——
——
——
——
——
——
——
——
——
——
——
——
——
——
——
——
——
——
——
——
LT100S250
LT100S300
LT100S250
——
LT100B250
LT100S300
LT100S250
——
LT100S300
LT100S300
——
LT100B250
——
LT100B350
LT100B350
LT100B350
LT100B350
LT100B350
LT100B350
LT100S300
LT100S300
LT100S300
LT100S250
LT100S300
LT100S250
LT100S300
LT100S350
——
LT100S300
LT100S300
——
——
LT100B350
LT100S300
LT100S250
LT100S300
LT100S250
LT100S300
——
——
LT100S250
——
——
——
——
LT100S250
LT100S300
——
LT100S300
LT100B250
LT100B250
LT100S250
LT100S300
——
——
——
LT100S300
LT100S250
6PT
6PT
6PT
9 X 17
6PT
6PT
6PT
6 X 14
6PT
6PT
6 X 14
6PT
9 X 17
9PT
9PT
9PT
9PT
9PT
9PT
9PT
9PT
9PT
9PT
9PT
9PT
9PT
9PT
9PT
9PT
9PT
9 X 17
9 X 17
9PT
9PT
9PT
9PT
9PT
9PT
9 X 17
9 X 17
14PT
14 X 21
14PT
9 X 17
9 X 17
9PT
9PT
9 X 17
9PT
9PT
9PT
9PT
9PT
9 X 17
9 X 17
9 X 17
9PT
9PT
ENCLOSURE
STYLE
page 23
HEIGHT
WIDTH
DEPTH
A
B
C
KNOCKOUT
FIGURE
page 23
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
-
17-3/8"
14-3/8"
14-3/8"
17-3/8"
17-3/8"
17-3/8"
17-3/8"
17-3/8"
21-3/8"
17-3/8"
17-3/8"
17-3/8"
17-3/8"
17-3/8"
17-3/8"
-
9-3/4"
7-1/4"
7-1/4"
9-3/4"
9-3/4"
9-3/4"
9-3/4"
9-3/4"
14-3/4"
9-3/4"
9-3/4"
9-3/4"
9-3/4"
9-3/4"
9-3/4"
-
5-3/16"
5-3/16"
5-3/16"
5-3/16"
5-3/16"
5-3/16"
5-3/16"
5-3/16"
6-7/16"
5-3/16"
5-3/16"
5-3/16"
5-3/16"
5-3/16"
5-3/16"
-
2
1
1
2
2
2
2
2
3
2
2
2
2
2
2
-
** For Post Cabinet Sizes and Dimensions see page 24.
22
Data subject to change without notice.
Cabinet Dimensions & Knockouts
RV Power Outlets - Cabinet Dimensions
CABINET
SIZE
ENCLOSURE
STYLE
A
B
C
6x9
6x14
9x17
9x30
14x21
Fig. A
Fig. A
Fig. A
Fig. B
Fig. A
9-1/8”
14-3/8”
17-3/8”
30”
21-3/8”
7-1/4”
7-1/4”
9-3/4”
9-3/4”
14-3/4”
5-3/16”
5-3/16”
5-3/16”
5-3/16”
6-7/16”
KO DETAIL
Fig.
Fig.
Fig.
Fig.
Fig.
1
1
2
2
3
Enclosure Style
(FIG. B)
(FIG. A)
Knockout Configurations
(FIG. 2)
(FIG. 1)
G
G
G
N
G
G
G
G
(FIG. 3)
D
G
G
B B
G
C
C
C
C
A
E
C
C
Q
A= 1-1/2", 2", 2-1/2"
D= 3/4", 1", 1-1/4"
N= 1/2", 3/4", 1", 1-1/4", 1-1/2"
B= 1", 1-1/4", 1-1/2"
E= 3/4"
Q= 1"
C= 1-1/4", 1-1/2", 2"
G= 1/2", 3/4", 1"
W= 1/2", 3/4", 1", 1-1/4", 2"
Data subject to change without notice.
23
Post Dimensions
6PT EARTH BURIAL
6PT PAD MOUNT
UNMETERED
A
UNMETERED
62"
C 19-3/4"
A
D 6-1/2"
C 17-3/4"
E 3-1/4"
D 6-1/2"
F
18"
E
G
6"
Single Head Post
Single Head Post
36"
3-3/4"
Double Head Post
(Back to Back)
Double Head Post
(Back to Back)
9PT PAD MOUNT
9PT EARTH BURIAL
UNMETERED
METERED
UNMETERED METERED
A
65"
77-1/2"
A 41-1/8" 53-1/2"
B
----
45-1/4"
B
19-1/8"
C 19-3/4" 19-1/2"
C 19-1/8"
D
9"
9"
E 3-1/2"*
D 9"
3-1/2"*
F
18"
18"
G
6"
6"
---
45-1/2"
9"
E 3-1/2"* 3-1/2"*
* Some models available
in 4-3/8". Contact
Distributor/Factory.
* Some models available in 4-3/8".
Contact Distributor/Factory.
Single Head Post
Single Head Post
Double Head Post
(Back to Back)
Double Head Post
(Back to Back)
14PT EARTH BURIAL
KEY
UNMETERED
METERED
A 83-1/2"
86"
B
50"
----
C 49-1/2"
D
9"
E 3-1/2"*
49-1/2"
9"
A=
B=
C=
D=
E=
F=
G=
Post Length
Meter Center to Grade
Terminal Bar to Grade
Post Width
Post Depth
Grade to Wire Opening
Wire Opening
3-1/2"*
F
18"
18"
G
6"
6"
* Some models available in 4-3/8".
Contact Distributor/Factory.
Single Head Post
24
Double Head Post
(Back to Back)
Data subject to change without notice.
Wire Range Tables
TABLE B
TABLE P
Copper
Connector
Copper
Aluminum
Connector
Solid
Strand
Solid
Strand
Line
14-8
14-6
12-8
12-6
Line
Load
14-10
14-10
----
----
Load
Neutral
12-8
12-6
12-8
12-6
Neutral
Equip. Grnd.
12-8
12-2
12-8
12-2
Neutral
End
Hole
Side
Hole
Equip. Grnd.
TABLE U
Line
Load
Neutral
Neutral
Large
Hole
Small
Hole
Equip. Grnd.
Load
Neutral
Neutral
Large
Hole
Small
Hole
Equip. Grnd.
Solid
Strand
14-8
14-1/0
12-8
12-1/0
14-10
14-10
----
----
14-8
14-2
12-8
12-2
14-8
14-4
12-8
12-4
12-8
12-2
12-8
12-2
Copper
Connector
Solid
Strand
Solid
Strand
14-8
14-1/0
12-8
12-1/0
Line
14-10
14-10
----
----
Load
(Loop Feed)
Large
Hole
Small
Hole
12-8
12-1/0
10-8
10-1/0
Neutral
14-8
14-4
12-8
12-4
Neutral
12-8
12-2
12-8
12-2
Equip. Grnd.
Aluminum
Solid
Strand
Solid
Strand
14-8
14-1/0
12-8
12-1/0
14-10
14-10
----
----
12-8
12-1/0
10-8
10-1/0
14-8
14-4
12-8
12-4
12-8
12-2
12-8
12-2
TABLE AR
Copper
Line
Strand
Aluminum
TABLE AA
Connector
Solid
TABLE W
Copper
Connector
Aluminum
Copper
Aluminum
Solid
Strand
Solid
Strand
----
6-1/0
----
6-1/0
14-10
14-10
----
----
12-8
12-1/0
10-8
10-1/0
14-8
14-4
12-8
12-4
12-8
12-2
12-8
12-2
Connector
Aluminum
Solid
Strand
Solid
Strand
Line
14-1/0
14-1/0
----
----
Load
14-10
14-10
----
----
Neutral
----
----
----
----
Equip. Grnd.
12-8
12-2
----
----
TABLE S
TABLE T2
Post Line Connectors
Suitable for Loop Feed
#6-350 KCMIL CU
#6-350 KCMIL AL
Post Line Connectors
Suitable for Loop Feed
#1-300 KCMIL CU
#1-300 KCMIL AL
Equip. Grnd.
Data subject to change without notice.
#12-2 CU/AL
Equip. Grnd.
#12-2 CU/AL
25
RV Non-Metallic
ParkMate/ParkRanger
ParkMateTM
12.75”
10”
20.75”
H3 Receptacle
(GFI duplex)
8“
Dockmate
shown with optional
Metallic Post
41.5”
Loop feed
Terminal Lugs
Double Head Post
(Back to Back)
ParkRangerTM
16.1
13.1
14.7
13.6
41.7
7.0
26
ParkMateTM
RV Power Center
ParkMate™ RV Power Centers represent the latest in technology and design, combining appearance and functionality. Now, campground owners can select an attractive power
center that combines all the features RVers request.
VKKJHCQT
ParkMate™ is excellent for surface mount and post applications, offering a wide array of accessories including: light,
photoelectric sensor, telephone, cable T.V. connections and
electric metering. All this in one attractive package - now
that makes sense!
Front Dimensions
D
8”
W
10”
H
13-1/2”
H
ParkMate™ is injection molded from VALOX® engineered
thermoplastic resin. VALOX® resin is a lightweight, impact
and corrosion resistant material, designed to provide long,
maintenance free service.
ParkMate™ RV Power Centers are rugged, convenient and
attractive. Manufactured in the quality tradition of Midwest
Electric Products, Inc.
D
Back Dimensions
D
8”
W
9-3/16”
H
12-1/8”
W
Interior view of the head
Features and Benefits
FLUORESCENT
LIGHT
Long lasting, low
consumption 7
watt light provides
security and easy
night time plug in.
ELECTRONIC
DIGITAL METER
MOLDED OF
®
TOUGH VALOX
THERMOPLASTIC
UP TO THREE
RECEPTACLES
AVAILABLE
CABLE TV JACK
TELEPHONE JACK
PHOTOCELL
(Not Shown)
SINGLE OR
BACK TO BACK
MODELS
G-90, HEAVILY
GALVANIZED
STEEL POST
WATER SHROUD
ACCESSORY
(faucet not
included)
20 AMP AVAILABLE
with GFI breaker or
GFI receptacles.
LOOP FEED LUGS
350 KCMIL
STANDARD
FACTORY WIRED
FOR EASY
INSTALLATION
DIRECT BURIAL
OR PAD MOUNT
INSTALLATION
Data subject to change without notice.
• 4-circuit load center installed (LC44X1)
• Service Entrance rated and Listed by Underwriters Laboratories
• VALOX® thermoplastic enclosure and internal components are corrosion resistant
• Factory wired power receptacles are available in 20 amp, 30 amp,
or 50 amp configurations protected by thermal magnetic circuit
breakers. Ground Fault breakers are also available
• Hinged cover closes over plugs and cords, maintaining a safe,
weather tight enclosure
• Easy to wire terminal lugs accept up to 1/0 Cu/Al cable
• Post features 350 KCMIL loop-feed lugs
• Optional 7 watt fluorescent light illuminates receptacle for easy night
time plug-in, while providing security lighting and easy identification
of power center location. Light circuit is protected by a 20 Amp circuit breaker. Light cover molded of LEXAN® polycarbonate
• Photoelectric sensor automatically turns light on and off
• Telephone and cable TV jack accessory kits mount easily in power
center, giving your installation a neat and uncluttered appearance.
Telephone jacks are PH6596 corrosion resistant outlets. Cable TV
jacks are suitable for type RG-59 coax cable.
• Electrical rating of 100 amp max., 120/240 volt, 1Ø-3 wire with
ground
• Hinged cover has a positive latch with padlocking provisions
• Post dimensions are 62"H (38" above grade) x 9"W x
3-1/4"D or 4-3/8" D
• Optional loop feed lug kit (ULOOP) available for Parkmate™ not on a
post
• ParkMate™, post, and water shroud are tan in color
• Standard 200A/350KCMIL lugs installed in Pedestal models.
• Amp Rating – 200 Amp on back-to-back; 100 Amp on single.
• Galvanized post is type G90-16 gauge
• Stainless post is type 304L-16 gauge
NOTE: Metered units for use in California require special testing and
certification. Contact Manufacturer for information.
27
ParkMateTM
Technical Information
Example: Model Number VPKJHCQT
VP
KJH
CQ
Model
Type
Side 1
Receptacle
Side 1
Options
Model Type
T
Side 2
Receptacle
Side 2
Options
Paint
Options
(where applicable)
(where applicable)
(standard tan)
Receptacles
Option Codes
Color
Most Common Models - Single Sided**
ParkMate
Model
Receptacle
Configuration
No
Options
7 watt light
7 watt light
& photocell
“CQ”
7 watt light,
photocell &
1 TV/Tel
Choose
Specific
Model
20A/20A
30A/20A
50A/20A
30A/30A/20A
50A/30A/20A
ZHHAAT
JZHAAT
KZHAAT
JJHAAT
KJHAAT
ZHHAQT
JZHAQT
KZHAQT
JJHAQT
KJHAQT
ZHHAUT
JZHAUT
KZHAUT
JJHAUT
KJHAUT
ZHHCQT
JZHCQT
KZHCQT
JJHCQT
KJHCQT
*model # prefix
not shown
“AA”
“AQ”
“AU”
“AC”
Metered
Only
“CS”
Metered, 7 watt
light, photocell,
1 TV/Tel
ZHHACT
JZHACT
KZHACT
JJHACT
KJHACT
ZHHCST
JZHCST
KZHCST
JJHCST
KJHCST
** Models can be single or double-sided. See Model Configurator on page 29.
Wiring Diagrams
S
P
A
C
E
S
P
A
C
E
S
P
A
C
E
30 20
7 watt light
S
P
A
C
E
30 20
S
P
A
C
E
S
P
A
C
E
S
P
A
C
E
30 20
7 watt light
S
P
A
C
E
30 20
7 watt light
digital meter
R32U
R32U
R32U
(1)-TV/phone
photo-cell
photo-cell
JZHAAT
30 20
7 watt light
30 20
7 watt light
50
GFI
7 watt light
50
GFI
50
GFI
JZHCST
JZHAUT
30 20
JZHCQT
30 20
5-20R2GFI
5-20R2GFI
5-20R2GFI
R32U
(1)-TV/phone
photo-cell
50
GFI
5-20R2GFI
digital meter
G
Y
W
5-20R2GFI
R32U
14-50R
R32U
14-50R
photo-cell
KJHAAT
28
KJHAUT
Y
X
W
5-20R2GFI
G
G
G
Y
X
5-20R2GFI
R32U
Y
X
W
14-50R
X
W
5-20R2GFI
R32U
14-50R
photo-cell
(1)-TV/phone
photo-cell
KJHCQT
KJHCST
(1)-TV/phone
ParkMate/ParkRanger
STEP 1:
Choose Unit Type (2 characters)
ParkMate
Single:
Back-to-Back:
VP
VS
Examples:
STEP 2:
Choose desired receptacles
for Head 1 or 2 (3 characters)
Single:
Back-to-Back:
KJH
KJH
Examples:
STEP 3:
Choose desired options
for Head 1 or 2 (2 characters)
Single:
Back-to-Back:
CQ
AW
Examples:
Repeat Steps 2 & 3 for any back-to-back models
to arrive at model number. Receptacles and options
can vary on back side.
Code
VK
VM
VN
VO
VP
VQ
VR
VS
VT
VW
VW
Unit Type-Base Only
ParkMate Power Center (Head Only)
ParkMate, single-side, w/stainless steel padmount post
ParkMate, single-side, w/stainless steel earth burial post
ParkMate, single-side, w/galvanized steel padmount post
ParkMate, single-side, w/galvanized steel earth burial post
ParkMate, back-to-back, w/stainless steel padmount post
ParkMate, back-to-back, w/stainless steel earth burial post
ParkMate, back-to-back, w/galvanized steel padmount post
ParkMate, back-to-back, w/galvanized steel earth burial post
ParkRanger, single-side, w/thermoplastic padmount post
ParkRanger, back-to-back, w/thermoplastic padmount post
Code
K
G
J
N
H
I
Most Common Receptacle/Circuit Breaker Combinations
(Straight Blade Receptacles)
14-50R 50 amp 125/250 V
14-50R 50 amp 125/250 V with GFI Breaker
R32U 30 amp 125 V
R32U 30 amp 125 V with GFI Breaker
5-20R2 20 amp 125 V with GFCI Duplex
5-20R2 20 amp 125 V Duplex with GFI Breaker
Code
AA
AQ
AU
AW
CQ
AC
AS
CM
CS
CO
BW
BY
DS
EK
EO
Options
No Options
7 watt light only
7 watt light and Photocell
7 watt light, Photocell, and Metered
1 TV/Tel, 7 watt light, and Photocell
Metered
7 watt light and Metered
1 TV/Tel and 7 watt light
1 TV/Tel, 7 watt light, Photocell, and Metered
1 TV/Tel, 7 watt light, and Metered
1 TV/Tel
1 TV/Tel and Metered
2 TV/Tel
2 TV/Tel and Metered
2 TV/Tel, 7 watt light, Photocell, and Metered
Accessories (Field Installed)
STEP 4:
Color
* May be factory installed using appropriate option code
ParkMate -- Standard Tan (add T suffix)
ParkRanger -- Standard White (add W suffix)
Contact factory for special paint requests.
Example
Models:
Model Configuration
Single:
VPKJHCQT
Back-to-Back:
VSKJHAWKJHAWT
Data subject to change without notice.
Model
VLIGHT
VLOOP
VAPE
VKTELTV1
VKTELTV2
ULUG3
UH11AL
UH12AL
UH90ST
UH90GT
UHH
UBFP
UWATER34
Description
7 Watt Fluorescent Light
1/0 Loop Lug Kit (For head only -- Loop lug installed in post)
Photoelectric sensor
TV/Tel Connection Kit (1 TV/Tel Jack)**
TV/Tel Connection Kit (2 TV/Tel Jacks)**
4th Position Lug For 3-Phase Loop Feed #6-350 KCMIL
Water Shroud (1) - Handicapped Accessible (ParkRanger)
Water Shroud (2) - Handicapped Accessible (ParkRanger)
Stainless Steel Water Shroud (ParkMate)
Galvanized Water Shroud (ParkMate)
One Pair Cord and Hose Storage Rack
Backflow Preventer
3/4” Hose Bib
** Standard RJ-11 Phone Jack
* Replacement Posts Available for ParkMate Models. Contact
Factory for more information. Reference ‘VB’ or ‘VP’ prefixes.
29
ParkRangerTM
Non-Metallic RV Power Pedestal
The Next Generation of Outdoor Luxury
ParkRanger is a new, non-metallic padmount power pedestal that combines all the
favorite features of the old pedestals with the advanced technology and advantages
of a non-metallic pedestal.
ALL THE AMENITIES OF HOME
• Power, running water, cable TV, and telephone access
• Multiple options available to fulfill individual needs
• Emphasis on convenience and safety
• Connections grouped behind weather resistant cover for easy access and security
• Lighting options provide clear view of service panel for nighttime connection
AESTHETICS AND DESIGN FLEXIBILITY
• Flip-top receptacles and other external components have been eliminated
• Clean, crisp lines
• Controlled lighting system for accent lighting
• Custom finishes
• Single or double-sided
• Individual site metering to recover electrical costs
INSTALLATION, UPGRADING AND MAINTENANCE ADVANTAGES
• Factory assembled and wired to minimize on-site
installation time and expense
• Advance shipping of base sections available to facilitate
rough wiring and plumbing
• Easy to change or add service options with upgrade kits
• Long-term durability
• Molded from GE engineered VALOX plastics
• Reduces corrosion problems
• Infrequent maintenance
FEATURES
• Unitized service panel to accept electrical components,
telephone, cable TV, and lighting options
• 100 to 200 amps for use with 120/240 volt, single phase,
3 wire plus ground
• Ambient compensated thermal magnetic circuit breaker
• Weather resistant with VALOX thermoplastic enclosure
• Corrosion resistant internal components
• Prismatic lens with lighting options to effectively eliminate
glare and create maximum illumination
• Dress panel on reverse side of all single service pedestals
• Oversize access panel for easy installation, upgrading and
quick meter reading
• Base module with loop feed terminal bar
• 4-Circuit load center installed
• 350 MCM loop feed
30
Data subject to change without notice.
ParkRangerTM
Technical Information
Example: Model Number VWKJHCQW
VW
KJH
CQ
Model
Type
Side 1
Receptacle
Side 1
Options
Model Type
W
Side 2
Receptacle
Side 2
Options
Paint
Options
(where applicable)
(where applicable)
(standard white)
Receptacles
Option Codes
Color
Most Common Models - Single Sided**
“AA”
“AU”
“CQ”
Receptacle
Configuration
No Options
7 watt light &
photocell
7 watt light, photocell, & 1 TV/Tel
“CS”
Metered w/ 7 watt
light, photocell,
& 1 TV/Tel
30A/20A
50A/30A/20A
VWJZHAAW
VWKJHAAW
VWJZHAUW
VWKJHAUW
VWJZHCQW
VWKJHCQW
VWJZHCSW
VWKJHCSW
** Models can be single or double-sided. See Model Configurator on page 29.
30 20
S
P
A
C
E
S
P
A
C
E
7 watt light
S
P
A
C
E
7 watt light
S
P
A
C
E
S
P
A
C
E
S
P
A
C
E
30 20
S
P
A
C
E
S
P
A
C
E
30 20
7 watt light
30 20
Wiring Diagrams
digital meter
R32U
R32U
7 watt light
30 20
50
GFI
7 watt light
30 20
VWJZHAUW
VWJZHCSW
7 watt light
50
GFI
photo-cell
VWJZHAAW
(1)-TV/phone
photo-cell
30 20
R32U
50
GFI
30 20
VWJZHCQW
5-20R2
5-20R2
5-20R2
R32U
(1)-TV/phone
photo-cell
50
GFI
5-20R2
digital meter
5-20R2
5-20R2
5-20R2
R32U
14-50R
R32U
14-50R
photo-cell
VWKJHAAW
Data subject to change without notice.
VWKJHAUW
5-20R2
R32U
14-50R
(1)-TV/phone
photo-cell
VWKJHCQW
R32U
14-50R
(1)-TV/phone
photo-cell
VWKJHCSW
31
Parts & Accessories
TEMPORARY ADAPTERS
(Not UL listed)
AD 20 30
AD 30 20
AD 50 20
ADAPTS
ADAPTS
ADAPTS
TO
TO
TO
15 AMP., 125 VOLT 30 AMP., 125 VOLT
10 PK. ONLY
30 AMP., 125 VOLT 15 AMP., 125 VOLT
10 PK. ONLY
RECEPTACLES AND
ANGLE PLUGS
50 AMP., 125/250 VOLT 15 AMP., 125 V.
10 PK. ONLY
Receptacles
Angle Plugs
Receptacles
on Plates
BR54U
C54U
PR54U
Angle Plugs
Offers increased flexibility by plugging into receptacles at an angle where space limitations exist.
Plugs are molded of Zytel® Nylon, a rugged impact
resistant material.
NEMA CONFIGURATIONS
AMP.
VOLTAGE
MODEL NUMBER
MODEL NUMBER
MODEL NUMBER
5-20 R
20
125
5-20R2 DUPLEX
—
—
30
125
BR32U1
R32U2
C32U
PR32U
30
30
50
50
60
60
125/250
125/250
125/250
125/250
120/208
125/250
BR331
BR341
BR531
BR54U1
--BR64U1
C33
C34
C53
C54U
C54
C64U
PR33
PR34
PR53
PR54U
--PR64U
ANSI C73 13-1972
R-32-U
30 AMP. 125 VOLT
(Travel Trailer Use Only)
10-30R
14-30R
10-50R
14-50R
18-60R
14-60R
(See Below)
1Receptacle
2Bracket
is complete with bracket to base mount into unit.
not included. Mounts directly on dead front.
Post Only
(With cover)
FEATURES
• Post only with 3 wire openings (back and both sides)
• Earth burial and pad mounted
• Terminal bar assembly with loop feed lugs standard
• Surface mount units may be field installed on these posts (Not UL listed)
• Swing-down hasp (latch) for padlock provision
• Painted 16 gauge galvanized steel
32
MODEL
NUMBER
DESCRIPTION
W
P5 POST
P6 POST
Pad Mount
Earth Burial
9
9
DIMENSIONS
H
D
59-1/2
83-1/2
4-1/2
4-1/2
520R2
FACTORY INSTALLED
TERMINAL ASSEMBLY
STD.
PKG
LT200B350
LT200B350
1
1
520R2GFI
(No Leads)
Data subject to change without notice.
Parts & Accessories
Post Extensions
Sealing Ring
EK126 6PT (6") Post Models
EK129* 9PT (9") Post Models
ASR1
Screw Style Sealing Ring for Ring-Type
Meter Sockets
Kit consists of: (1) Post Extension Bracket,
(2) 1/2" Bolts, (2) 1/2" Nuts, (4) 1/2"
Flatwashers.
Dimensions: 18"L x 6"W or 9"W
SNPR1
Snap-On Style Sealing Ring for RingType Meter Sockets
*Add “CW” for WEPCO Approved Model
Bolt-On Hub
Post Stake
(Standard Pkg Qty in 10 pcs.)
Closure plate is standard with most
Midwest products.
Order appropriate hub from chart below.
MS62
Kit consists of: (1) Post Stake Bracket,
(2) 1/2" Bolts, (2) 1/2" Nuts, (4) 1/2"
Flatwashers.
Dimensions: 44"L x 3"W or 1"D
MODEL NUMBER
HUB SIZE
Tie Bars
121
131
(threaded)
MIDWEST HUB
UNIVERSAL HUB
3/4"
B07
––––
1"
B10
U10
1-1/4"
B12
U12
1-1/2"
B15
U15
2"
B20
U20
2-1/2"
B25
U25
3"
U30
4"
––––
––––
––––
CLOSURE PLATE – SM
B01
U01
CLOSURE PLATE – LG
––––
U04
3-1/2"
Stabilizer Base & Stabilizer Foot Kit
FBEM9
Earth Burial Installation
- wire from back only
U40
*For replacement hub screws, order B01, U01, or U04 as appropriate.
SFEM9
SFEM6
6" Stabilizer Foot Kit
FBEM9
U35
SFEM9
9" Stabilizer Foot Kit
Circuit Breaker Filler Plates
MODEL
265A5003P1
265A5003P2
265A5003P11
DESCRIPTION
1" Metal
2" Metal
1" Plastic
265A5003P12
2" Plastic
- wire from side or back
Touch-Up Paint
TV/Telephone Add-On
TTV100 – TV/Telephone Add-on accessory bolts
on at ground level to the back of a padmount
post, earth-burial post, or a wall. The open back
and open bottom make for easy wiring. Factory
or field-installed TV/Telephone receptacle may be
field replaced with data (Cat5) or other similar
feature receptacle. Includes in-use cover.
- Unit is non-NEMA and non-UL
- RJ11 Phone Jack; height 12 inches
- will mount on pad or direct burial post
Data subject to change without notice.
Textured Paint
PRODUCT NUMBER
PCAMOTEX
PTANTEX
PBLUETEX
PWHITETEX
PBRONZETEX
Glossy Paint
PBLUE
PGRAY61
PTAN
PWHITE
DESCRIPTION
Camo Green
Tan
Blue
White
Bronze
Blue
Gray
Tan
White
33
Parts & Accessories
Water Shroud & Hose Bib
Water Shroud Models:
UH20GG - Adapts to 6” wide galvanized steel post - grey color
UH90G - Adapts to 9” wide galvanized steel post - grey color
UH90GT - Adapts to 9”wide galvanized steel post - tan color
UH90ST - Adapts to 9” wide stainless steel post - tan color
UH11AL - Water shroud (1) - Handicap Accessible (ParkRanger)
UH12AL - Water shroud (2) - Handicap Accessible (ParkRanger)
Hose Bib:
UWATER34 - 3/4” Hose Bib Faucet for Post Applications
Water
Shroud
Water Shroud and Hose Bib
Connected on ParkMate
Camper Clips
50-Amp Receptacle Lockout Panel
CLP1
- Kit contains: 6 clips and 6 screws
PLK50 - Replacement deadfront kit with 50-Amp
Receptacle lockout feature for all U075- or M075series units, with Sample
Deadfront
GFCI duplex
cut-out.
- Tempered steel (galvanized, zinc-coated) spring tensioned clips used to attach site cards to post.
- Dimensions: 1” W x 2.13” H
Included in
PLK50 Kit:
Replacement
Deadfront &
Plate Cover for
50 Amp Receptacle
50 Amp
RV Substation
Midwest Electric’s RV substations provide a safe,
economical way to deliver power to Power Centers
and Power Pedestals.
The substations consist of a core and coil dry-type
transformer and a distribution panelboard in a
common enclosure.
• NEMA 3R, Marine grade enclosures
• 15kva-300kva transformer range
• Contact Midwest rep for additional information
34
Parts & Accessories
Load Center Interiors
Part Number
LC33N1
LC33N1T
LC33N7
LC44X1
LC55N1T
LC55N1
LC1212PC
Circuits
3
3
3
4
5
5
12
Volts
120/240
120/240
120/240
120/240
120/240
120/240
120/240
Amps
100
100
70
100
100
100
200
Line Lug Size
#14-1/0 CU AL
(2)#14-1/0 CU AL/Phase
#14-1/0 CU AL
#14-1/0 CU AL
(2)#14-1/0 CU AL/Phase
#14-1/0 CU AL
#6-250 KCMIL
LC33N7
LC33N1T
LC33N1
LC55N1
Neutral Lug Size
(2)#14-1/0, (2)#14-4 CU AL
(2)#14-1/0, (2)#14-4 CU AL
(4)#14-2 CU AL
None
(2)#14-1/0, (2)#14-4 CU AL
(2)#14-1/0, (2)#14-4 CU AL
None
LC44X1
LC1212PC
LC55N1T
Meter Bases
100 Amp sockets for models manufactured after February 1995
Replacement
Model No.
Type
Rating
Lug Style
Line Lug
Wire Range
Optional
Neutral Kit
MSM1009301
Ring-Type
100
Lay-in
#6-350KCMIL
MSBN4
9" x 30" Surface Panels
MSR100930
Ringless
100
Lay-in
#6-350KCMIL
MSBN4
9" x 30" Surface Panels
MSM100P91
Ring-Type
100
Lay-in
#6-350KCMIL
MSBN4
9PT Single Sided Posts
MSR100P9
Ringless
100
Lay-in
#6-350KCMIL
MSBN4
9PT Single Sided Posts
MSBN4
All Other Panels and Post Units
Description
200 Amp socket for models manufactured after 1984
MW200M1
1
Ring-Type
200
Box Style
1/0-350KCMIL
Midwest Electric manufactured meter socket only.
MSM100930
35
MSR100P9
MW200M
Manufacturer’s Sales Representatives Offices
A
*
A
British Columbia
A
A
A
75
Lachine,
Quebec
Auburn
30
*
*
66
Billings
30
Minneapolis
37
6
*
*
*
*
Milwaukee
*
Salt Lake
City
23
36
Kansas
City
59
83
55
35
Los Angeles
*
*
50
Cincinnati
*
*
*
*
39
Atlanta
KEY:
*
58
Houston
*
29
62
*
41
Irving
30
12
Farmingdale
Greensboro
7
*
25
*
*
Glen Allen
*
56
53
Tempe
*
77
Millersville
*57
Memphis
85
Bensalem
*
Woburn
45
Louisville
St. Louis
Little Rock
Oklahoma City
*
46
11
*
Indianapolis
La Vergne
Tulsa
Pittsburgh
* *
Hudson
61
Council Bluffs
*
Denver
Syracuse
Detroit
Elk Grove
Village
9
Sausalito
*
22
Mankato
*
A
36
Portland
*
Representative Office Headquarters
Factory and Headquarters
Representative Territories
Metairie
72
State/Province Borders
Deerfield
Beach
*
1
Midwest Electric Products, Inc.
Mankato, MN 56002
Phone: (507) 345-2505
FAX: (507) 345-2530
www.midwestelectric.com
25
Electra Sales of North Texas, Inc.
Irving, TX 75061
Phone: (972) 554-8200
FAX: (972) 554-7861
www.electrasales.net
A
Hydel
Vaughan, ON L4K5W1
Phone: (800) 263-4579
FAX: (905) 669-4518
www.circaent.com/hydel
29
E-Tel
Houston, TX 77028
Phone: (713) 678-4460
FAX: (713) 678-4371
www.etelinc.com
6
Lesco, Inc.
Milwaukee, WI 53225
Phone: (414) 393-1428
FAX: (414) 438-0741
www.lesco-inc.com
30
Robert A. Amey Company
Portland, OR 97229
Phone: (503) 646-7196
FAX: (503) 626-8569
www.ameyco.com
50
Schaeffer Sales, Inc.
St. Louis, MO 63043
Phone: (314) 291-9500
FAX: (314) 291-9595
www.schaeffersales.com
7
Bishop & Brogdon
Atlanta, GA 30336
Phone: (404) 494-4333
(800) 241-2963
FAX: (404) 344-3696
35
53
9
Bixler Marketing Group
Council Bluffs, IA 51501
Phone: (712) 328-1841
(888) 924-9537
FAX: (712) 328-7449
www.bixlermarketing.com
SEGI
Tempe, AZ 85282
Phone: (480) 317-0868
(866) 969-7344
FAX: (480) 317-0875
www.segisalespros.com
36
SEGI
Billings, MT 59101
Phone: (406) 248-9224
FAX: (406) 245-6953
55
37
Electro-Lines, Inc.
Syracuse, NY 13208
Phone: (315) 455-5701
(800) 962-5760
FAX: (315) 455-7114
www.electrolines.com
11
12
Arthur Boyle Company, Inc.
Indianapolis, IN 46220
Phone: (317) 577-9100
(800) 776-9101
FAX: (317) 577-9161
Gumersell Cashdan, Inc.
Farmingdale, NY 11735
Phone: (631) 752-9440
FAX: (631) 752-9415
www.gumcash.com
22
G.N. Deperro Company
Detroit, MI 48211
Phone: (313) 875-4010-11-12
(800) 875-9120
FAX: (313) 872-5544
23
Electrorep
Sausalito, CA 94965
Phone: (415) 332-4100
FAX: (415) 332-4150
www.electrorep.com
39
Farmer Electrical Sales, Inc.
Greensboro, NC 27415
Phone: (336) 375-1122
(800) 849-0244
FAX: (336) 375-0177
www.farmerelectrical.com
41
L.W. French, Inc.
Glen Allen, VA 23060
Phone: (804) 270-3205
FAX: (804) 270-0885
www.lwfrench.com
45
Gemco Sales, Inc.
Pittsburgh, PA 15201
Phone: (412) 562-9300
FAX: (412) 562-9028
46
J.R. Bovyer Electrical Sale of OH
Hudson, OH 44236
Phone: (330) 656-4128
(800) 362-6613
FAX: (330) 650-2586
www.bovyereso.com
59
MWE, Inc.
Kansas City, MO 64108
Phone: (816) 842-9283
FAX: (888) 842-8047
www.mweinc.com
61
Schmitz Electrical Sales
Elk Grove Village, IL 60007
Phone: (847) 364-3605
FAX: (847) 364-4107
62
O.T. Hall & Son, Inc.
Millersville, MD 21108
Phone: (410) 987-5990
(888) 621-7435
FAX: (410) 987-9691
www.othall.com
Curtis H. Stout, Inc.
Little Rock, AR 72202
Phone: (501) 372-2555
FAX: (501) 375-4453
www.curtishstoutinc.com
66
Lesco, Inc.
Minneapolis, MN 55427
Phone: (763) 542-8242
FAX: (763) 542-9309
www.lesco-inc.com
Electrical Products of Oklahoma
Oklahoma City, OK 73116
Phone: (405) 842-8371
FAX: (405) 843-1636
72
Tulsa, OK 74112
Phone: (918) 663-1923
Fax: (918) 663-0015
Metra Associates, Inc.
Deerfield Beach, FL 33442
Phone: (954) 428-4444
(800) 201-3465
FAX: (954) 428-4455
www.metra-assoc.com
75
John Moore & Associates, Inc.
La Vergne, TN 37086
Phone: (615) 287-0500
FAX: (615) 287-0662
www.jmaone.com
Theovine, Inc.
Lachine, Quebec, Canada
Phone: (514) 637-0050
FAX: (514) 637-4630
www.theovine.com
77
David Role & Co.
Woburn, MA 01801
Phone: (781) 932-8810
(800) 878-0852
FAX: (781) 932-8815
Cincinnati, OH 45227
Phone: (513) 561-0500
800-582-0500
Fax: (513) 561-1811
56
Memphis, TN 38114
Phone: (901) 948-0193
FAX: (901) 948-0194
57
Summit Sales & Marketing, Inc.
Louisville, KY 40203
Phone: (888) 279-2780
FAX: (502) 636-2575
www.summitsales-mkt.com
83
J.R. Schmidt & Associates
Englewood, CO 80115
Phone: (866) 592-1313
FAX: (303) 778-7613
www.jr-schmidt.com
58
Syn-Tech, Inc.
Metairie, LA 70002
Phone: (504) 835-7825
(800) 535-7619
FAX: (504) 835-7853
www.syntech-inc.com
85
Pollart Electrical Sales Co., Inc.
Bensalem, PA 19020
Phone: (800) 372-8000
FAX: (215) 245-0773
www.pollart-electrical.com
36
Download