Engine MTU , 16V4000G63F Alternator LEROY

advertisement
X2500
Engine MTU , 16V4000G63F
Alternator LEROY SOMER , LSA512VL90
<Debut>
STANDARD FEATURES
n
n
n
Electronic governor
Mechanically welded chassis with antivibration suspension
n
Exhaust compensators with flanges
n
24 V charge alternator and starter
n
Delivered with oil
n
Manual for use and installation
Air cooler for wiring temperature of 47/50°C with electric fan
415/240
400/230
Power ESP
kWe/kVA
2000 / 2500
2000 / 2500
Power PRP
kWe/kVA
1818 / 2273
1818 / 2273
380/220
2000 / 2500
1818 / 2273
Voltage
Standby Amps
Dimensions
Weight
3478
3609
Leng : 4818mm [190in]
3798
Widt : 1885mm [74in]
14235kg [31383lbs] Net
14825kg [32684lbs]
Gross
Heig : 2158mm [85in]
POWER DEFINITION
PRP : Prime Power is available for an unlimited number of annual operating hours in variable load applications, in accordance with ISO
8528-1.
ESP : The standby power rating is applicable for supplying emergency power in variable load applications in accordance with ISO
8528-1. Overload is not allowed.
TERM OF USE
Standard reference conditions ESP/PRP 27 C°/40 C° Air Intlet Temp, 1000 m/1000 m m A.S.L. 60 % relative humidity.
%Modèle
dB(A)@1m
dB(A)@7m
Dimensions
Weight
Leng : 12192mm [480in]
26690kg [58841lbs]
Widt : 2438mm [96in]
EUR40Si
85
75
28220kg [62214lbs]
Heig : 2896mm [114in]
EUR40SSi
79
69
Leng : 12192mm [480in]
Widt : 2438mm [96in]
Heig : 2896mm [114in]
27380kg [60363lbs]
28910kg [63736lbs]
This document is not contractual - The SDMO company reserves the right to modify any of the characteristics stated in this CD Rom
without notice, in a constant effort to improve the quality of its products.
SDMO Industries – 12bis rue de la Villeneuve – CS 92848 – 29 228 BREST CEDEX 2
Tel +33 (0)2 98 41 41 41 – Fax : +33 (0)2 98 41 63 07 – www.sdmo.com
Tank
500 L
500 L
ENGINE SPECIFICATIONS
Motor model
DATA
GENERAL DATA
Cylinder arrangement
Displacement (C.I.)
Bore (mm) X Stroke (mm)
Compression ratio
Speed (RPM)
Pistons speed (m/s)
Maximum stand-by power at rated RPM (kW)
Frequency regulation (%)
BMEP (bar)
Governor type
MTU 16V4000G63F , 4-temps, TURBO ,
AIR/WATER 16 X
V
76.27
170 X 210
16.5
1500
10.5
2162
0.5
20.61
ELEC
Exhaust gas temperature (°F)
Exhaust gas flow (L/s)
Max. exhaust back pressure (mm CE)
485
5800
300
FUEL SYSTEM
Consumption @ 110% load (L/h)
Consumption @ 100% load (L/h)
Consumption @ 75% load (L/h)
Consumption @ 50% load (L/h)
Maximum fuel pump flow (L/hr)
N/A
436
331
232
1500
OIL
Oil capacity (L)
Min. oil pressure (bar)
Max. oil pressure (bar)
Oil consumption 100% load (L/h)
Carter oil capacity (L)
300
3.5
7
1.31
240
Heat rejection to exhaust (kW)
N/A
Radiated heat to ambiant (kW)
Haet rejection to coolant (kW)
90
730/320
EXHAUST SYSTEM
THERMAL
BALANCE
AIR INTAKE
COOLANT SYSTEM
EMISSIONS
AIR INTAKE_entree_max%
Intake air flow (L/s)
Radiator & Engine capacity (L)
Max water temperature (°C)
Outlet water temperature (°C)
Fan power (kW)
Fan air flow w/o restriction (m3/s)
Available restriction on air flow (mm CE)
Type of coolant
Thermostat (°C)
150
2300
N/A
104
100
N/A
N/A
N/A
COOLELF-MDX
79/92
Emissions PM (g/kW.h)
Emission CO (g/kW.h)
Emissions HCNOx (g/kWh)
N/A
N/A
N/A
Emission HC (g/kW.h)
N/A
This document is not contractual - The SDMO company reserves the right to modify any of the characteristics stated in this CD Rom
without notice, in a constant effort to improve the quality of its products.
SDMO Industries – 12bis rue de la Villeneuve – CS 92848 – 29 228 BREST CEDEX 2
Tel +33 (0)2 98 41 41 41 – Fax : +33 (0)2 98 41 63 07 – www.sdmo.com
ALTERNATOR SPECIFICATIONS
DATA
GENERAL DATA
OTHER
DATA
Alternator brand
Alternator
Number of phase
Power factor (Cos Phi)
Altitude (m)
Overspeed (rpm)
Number of pole
Excitation system
Insulation class / Temperature class
Regulation
Total harmonics TGH/THC
Wave form : NEMA=TIF-TGH/THC
Wave form : CEI=FHT-TGH/THC
Number of bearing
Coupling
Voltage regulation 0 ŕ 100%
Recovery time (Delta U = 20% transitoire) (ms)
Continuous Nominal Rating 40°C (kVA)
Standby Rating 27°C (kVA)
Efficiencies 4/4 load (%)
Air flow (m3/s)
Short circuit ratio (Kcc)
Direct axis synchro reactance unsaturated (Xd) (%)
Quadra axis synchro reactance unsaturated (Xq) (%)
Open circuit time constant (T'do) (ms)
Direct axis transient reactance saturated (X'd) (%)
Short circuit transient time constant (T'd) (ms)
Direct axis subtransient reactance saturated (X''d) (%)
Subtransient time constant (T"d) (ms)
Quadra axis subtransient reactance saturated (X"q) (%)
Zero sequence reactance unsaturated (Xo) (%)
Negative sequence reactance saturated (X2) (%)
Armature time constant (Ta) (ms)
No load excitation current (io) (ms)
Full load excitation current (ic) (A)
Full load excitation voltage (uc) (A)
Recovery time (Delta U = 20% transitoire) (ms)
Motor start (Delta U = 20% perm. or 50% trans.) (ms)
Transient dip (4/4 charge) - PF : 0,8 AR (%)
No load losses (kW)
Heat rejection (kW)
LEROY SOMER
LSA512VL90
3
0.8
<1000
2160
4
AREP
H/H
R449
<4
<50
<2
1
DIRECT
1
N/A
2345
2580
96.5
N/A
0.43
290
174
3050
25
260
13
26
16.3
2.6
14.6
49
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
This document is not contractual - The SDMO company reserves the right to modify any of the characteristics stated in this CD Rom
without notice, in a constant effort to improve the quality of its products.
SDMO Industries – 12bis rue de la Villeneuve – CS 92848 – 29 228 BREST CEDEX 2
Tel +33 (0)2 98 41 41 41 – Fax : +33 (0)2 98 41 63 07 – www.sdmo.com
CONTROL PANEL
#STD_COFFRET
Standard
M80
M80
Specifications : Tachometer, Emergency stop button, client
connection terminal strip, EC certified
Engine parameters :Hours counter, Oil pressure gauge,
Water temperature indicator, Oil pressure indicator
Option
TELYS
TELYS
Specifications : Frequency meter, Ammeter, Voltmeter
Alarms and faults : Oil pressure, water temperature, No
start-up, Overspeed, Min/max alternator, Min/max battery
voltage, Low fuel level, Emergency stop
Engine parameters : Hours counter, Oil pressure, Water
temperature, Engine speed, Battery voltage, Fuel level
Option
KERYS
KERYS
Specifications : Frequency meter, Ammeter, Voltmeter
Alarms and faults : Oil pressure, water temperature, No
start-up, Overspeed, Min/max alternator, Min/max battery
voltage, Low fuel level, Emergency stop
Engine parameters : Hours counter, Oil pressure, Water
temperature, Engine speed, Battery voltage, Fuel level
Additional specifications :Website, Troubleshooting,
Assistance and Maintenance, Plotting and logging, Load
impact, 8 configurations available, Compliance with
international standards...
#OPT1
#OPT2
#OPT3
This document is not contractual - The SDMO company reserves the right to modify any of the characteristics stated in this CD Rom
without notice, in a constant effort to improve the quality of its products.
SDMO Industries – 12bis rue de la Villeneuve – CS 92848 – 29 228 BREST CEDEX 2
Tel +33 (0)2 98 41 41 41 – Fax : +33 (0)2 98 41 63 07 – www.sdmo.com
Download