T2200 Engine MITSUBISHI , S16R-PTAA2 Alternator LEROY SOMER , LSA512M60 <Debut> STANDARD FEATURES n n n Electronic governor Mechanically welded chassis with antivibration suspension Radiator for wiring temperature of 48/50°C max with mechanical fan n Protective grille for fan and rotating parts n Exhaust compensators with flanges n 24 V charge alternator and starter n Delivered with oil and coolant -30°C n Manual for use and installation 415/240 400/230 Power ESP kWe/kVA 1760 / 2200 1760 / 2200 Power PRP kWe/kVA 1600 / 2000 1600 / 2000 380/220 1760 / 2200 1600 / 2000 Voltage Standby Amps Dimensions Weight 3061 3176 Leng : 5497mm [216in] 3343 Widt : 2286mm [90in] 14371kg [31683lbs] Net 14998kg [33065lbs] Gross Heig : 2580mm [102in] POWER DEFINITION PRP : Prime Power is available for an unlimited number of annual operating hours in variable load applications, in accordance with ISO 8528-1. ESP : The standby power rating is applicable for supplying emergency power in variable load applications in accordance with ISO 8528-1. Overload is not allowed. TERM OF USE Standard reference conditions ESP/PRP 27 C°/40 C° Air Intlet Temp, 1000 m/1000 m m A.S.L. 60 % relative humidity. This document is not contractual - The SDMO company reserves the right to modify any of the characteristics stated in this CD Rom without notice, in a constant effort to improve the quality of its products. SDMO Industries – 12bis rue de la Villeneuve – CS 92848 – 29 228 BREST CEDEX 2 Tel +33 (0)2 98 41 41 41 – Fax : +33 (0)2 98 41 63 07 – www.sdmo.com ENGINE SPECIFICATIONS Motor model DATA GENERAL DATA Cylinder arrangement Displacement (C.I.) Bore (mm) X Stroke (mm) Compression ratio Speed (RPM) Pistons speed (m/s) Maximum stand-by power at rated RPM (kW) Frequency regulation (%) BMEP (bar) Governor type MITSUBISHI S16R-PTAA2 , 4-temps, TURBO , AIR/AIR 16 X V 65.37 170 X 180 13.5 : 1 1500 9 1895 0.25 20.61 ELEC Exhaust gas temperature (°F) Exhaust gas flow (L/s) Max. exhaust back pressure (mm CE) 524 7000 600 FUEL SYSTEM Consumption @ 110% load (L/h) Consumption @ 100% load (L/h) Consumption @ 75% load (L/h) Consumption @ 50% load (L/h) Maximum fuel pump flow (L/hr) 458.1 401.7 307.3 212.8 588 OIL Oil capacity (L) Min. oil pressure (bar) Max. oil pressure (bar) Oil consumption 100% load (L/h) Carter oil capacity (L) 230 2.5 6.5 1.5 140 Heat rejection to exhaust (kW) 1443 Radiated heat to ambiant (kW) Haet rejection to coolant (kW) 139 603+556 EXHAUST SYSTEM THERMAL BALANCE AIR INTAKE COOLANT SYSTEM EMISSIONS AIR INTAKE_entree_max% Intake air flow (L/s) Radiator & Engine capacity (L) Max water temperature (°C) Outlet water temperature (°C) Fan power (kW) Fan air flow w/o restriction (m3/s) Available restriction on air flow (mm CE) Type of coolant Thermostat (°C) 400 2650 413 98 95 39 23 20 GENCOOL 71-85 Emissions PM (g/kW.h) Emission CO (g/kW.h) Emissions HCNOx (g/kWh) N/A N/A N/A Emission HC (g/kW.h) N/A This document is not contractual - The SDMO company reserves the right to modify any of the characteristics stated in this CD Rom without notice, in a constant effort to improve the quality of its products. SDMO Industries – 12bis rue de la Villeneuve – CS 92848 – 29 228 BREST CEDEX 2 Tel +33 (0)2 98 41 41 41 – Fax : +33 (0)2 98 41 63 07 – www.sdmo.com ALTERNATOR SPECIFICATIONS DATA GENERAL DATA OTHER DATA Alternator brand Alternator Number of phase Power factor (Cos Phi) Altitude (m) Overspeed (rpm) Number of pole Excitation system Insulation class / Temperature class Regulation Total harmonics TGH/THC Wave form : NEMA=TIF-TGH/THC Wave form : CEI=FHT-TGH/THC Number of bearing Coupling Voltage regulation 0 à 100% Recovery time (Delta U = 20% transitoire) (ms) Continuous Nominal Rating 40°C (kVA) Standby Rating 27°C (kVA) Efficiencies 4/4 load (%) Air flow (m3/s) Short circuit ratio (Kcc) Direct axis synchro reactance unsaturated (Xd) (%) Quadra axis synchro reactance unsaturated (Xq) (%) Open circuit time constant (T'do) (ms) Direct axis transient reactance saturated (X'd) (%) Short circuit transient time constant (T'd) (ms) Direct axis subtransient reactance saturated (X''d) (%) Subtransient time constant (T"d) (ms) Quadra axis subtransient reactance saturated (X"q) (%) Zero sequence reactance unsaturated (Xo) (%) Negative sequence reactance saturated (X2) (%) Armature time constant (Ta) (ms) No load excitation current (io) (ms) Full load excitation current (ic) (A) Full load excitation voltage (uc) (A) Recovery time (Delta U = 20% transitoire) (ms) Motor start (Delta U = 20% perm. or 50% trans.) (ms) Transient dip (4/4 charge) - PF : 0,8 AR (%) No load losses (kW) Heat rejection (kW) LEROY SOMER LSA512M60 3 0.8 <1000 2250 4 AREP H/H R449 N/A <50 <2 1 DIRECT 1 <700 2050 2200 95.7 2.5 0.35 357 214 2800 31.6 250 13.5 23 17.5 3.3 15.7 41 1.5 5.9 62 <700 4000 12 17.5 70.1 This document is not contractual - The SDMO company reserves the right to modify any of the characteristics stated in this CD Rom without notice, in a constant effort to improve the quality of its products. SDMO Industries – 12bis rue de la Villeneuve – CS 92848 – 29 228 BREST CEDEX 2 Tel +33 (0)2 98 41 41 41 – Fax : +33 (0)2 98 41 63 07 – www.sdmo.com CONTROL PANEL #STD_COFFRET Standard M80 M80 Specifications : Tachometer, Emergency stop button, client connection terminal strip, EC certified Engine parameters :Hours counter, Oil pressure gauge, Water temperature indicator, Oil pressure indicator Option TELYS TELYS Specifications : Frequency meter, Ammeter, Voltmeter Alarms and faults : Oil pressure, water temperature, No start-up, Overspeed, Min/max alternator, Min/max battery voltage, Low fuel level, Emergency stop Engine parameters : Hours counter, Oil pressure, Water temperature, Engine speed, Battery voltage, Fuel level Option KERYS KERYS Specifications : Frequency meter, Ammeter, Voltmeter Alarms and faults : Oil pressure, water temperature, No start-up, Overspeed, Min/max alternator, Min/max battery voltage, Low fuel level, Emergency stop Engine parameters : Hours counter, Oil pressure, Water temperature, Engine speed, Battery voltage, Fuel level Additional specifications :Website, Troubleshooting, Assistance and Maintenance, Plotting and logging, Load impact, 8 configurations available, Compliance with international standards... #OPT1 #OPT2 #OPT3 This document is not contractual - The SDMO company reserves the right to modify any of the characteristics stated in this CD Rom without notice, in a constant effort to improve the quality of its products. SDMO Industries – 12bis rue de la Villeneuve – CS 92848 – 29 228 BREST CEDEX 2 Tel +33 (0)2 98 41 41 41 – Fax : +33 (0)2 98 41 63 07 – www.sdmo.com