Engine MITSUBISHI , S16R-PTAA2 Alternator LEROY SOMER

advertisement
T2200
Engine MITSUBISHI , S16R-PTAA2
Alternator LEROY SOMER , LSA512M60
<Debut>
STANDARD FEATURES
n
n
n
Electronic governor
Mechanically welded chassis with antivibration suspension
Radiator for wiring temperature of 48/50°C max with
mechanical fan
n
Protective grille for fan and rotating parts
n
Exhaust compensators with flanges
n
24 V charge alternator and starter
n
Delivered with oil and coolant -30°C
n
Manual for use and installation
415/240
400/230
Power ESP
kWe/kVA
1760 / 2200
1760 / 2200
Power PRP
kWe/kVA
1600 / 2000
1600 / 2000
380/220
1760 / 2200
1600 / 2000
Voltage
Standby Amps
Dimensions
Weight
3061
3176
Leng : 5497mm [216in]
3343
Widt : 2286mm [90in]
14371kg [31683lbs] Net
14998kg [33065lbs]
Gross
Heig : 2580mm [102in]
POWER DEFINITION
PRP : Prime Power is available for an unlimited number of annual operating hours in variable load applications, in accordance with ISO
8528-1.
ESP : The standby power rating is applicable for supplying emergency power in variable load applications in accordance with ISO
8528-1. Overload is not allowed.
TERM OF USE
Standard reference conditions ESP/PRP 27 C°/40 C° Air Intlet Temp, 1000 m/1000 m m A.S.L. 60 % relative humidity.
This document is not contractual - The SDMO company reserves the right to modify any of the characteristics stated in this CD Rom
without notice, in a constant effort to improve the quality of its products.
SDMO Industries – 12bis rue de la Villeneuve – CS 92848 – 29 228 BREST CEDEX 2
Tel +33 (0)2 98 41 41 41 – Fax : +33 (0)2 98 41 63 07 – www.sdmo.com
ENGINE SPECIFICATIONS
Motor model
DATA
GENERAL DATA
Cylinder arrangement
Displacement (C.I.)
Bore (mm) X Stroke (mm)
Compression ratio
Speed (RPM)
Pistons speed (m/s)
Maximum stand-by power at rated RPM (kW)
Frequency regulation (%)
BMEP (bar)
Governor type
MITSUBISHI S16R-PTAA2 , 4-temps, TURBO ,
AIR/AIR 16 X
V
65.37
170 X 180
13.5 : 1
1500
9
1895
0.25
20.61
ELEC
Exhaust gas temperature (°F)
Exhaust gas flow (L/s)
Max. exhaust back pressure (mm CE)
524
7000
600
FUEL SYSTEM
Consumption @ 110% load (L/h)
Consumption @ 100% load (L/h)
Consumption @ 75% load (L/h)
Consumption @ 50% load (L/h)
Maximum fuel pump flow (L/hr)
458.1
401.7
307.3
212.8
588
OIL
Oil capacity (L)
Min. oil pressure (bar)
Max. oil pressure (bar)
Oil consumption 100% load (L/h)
Carter oil capacity (L)
230
2.5
6.5
1.5
140
Heat rejection to exhaust (kW)
1443
Radiated heat to ambiant (kW)
Haet rejection to coolant (kW)
139
603+556
EXHAUST SYSTEM
THERMAL
BALANCE
AIR INTAKE
COOLANT SYSTEM
EMISSIONS
AIR INTAKE_entree_max%
Intake air flow (L/s)
Radiator & Engine capacity (L)
Max water temperature (°C)
Outlet water temperature (°C)
Fan power (kW)
Fan air flow w/o restriction (m3/s)
Available restriction on air flow (mm CE)
Type of coolant
Thermostat (°C)
400
2650
413
98
95
39
23
20
GENCOOL
71-85
Emissions PM (g/kW.h)
Emission CO (g/kW.h)
Emissions HCNOx (g/kWh)
N/A
N/A
N/A
Emission HC (g/kW.h)
N/A
This document is not contractual - The SDMO company reserves the right to modify any of the characteristics stated in this CD Rom
without notice, in a constant effort to improve the quality of its products.
SDMO Industries – 12bis rue de la Villeneuve – CS 92848 – 29 228 BREST CEDEX 2
Tel +33 (0)2 98 41 41 41 – Fax : +33 (0)2 98 41 63 07 – www.sdmo.com
ALTERNATOR SPECIFICATIONS
DATA
GENERAL DATA
OTHER
DATA
Alternator brand
Alternator
Number of phase
Power factor (Cos Phi)
Altitude (m)
Overspeed (rpm)
Number of pole
Excitation system
Insulation class / Temperature class
Regulation
Total harmonics TGH/THC
Wave form : NEMA=TIF-TGH/THC
Wave form : CEI=FHT-TGH/THC
Number of bearing
Coupling
Voltage regulation 0 à 100%
Recovery time (Delta U = 20% transitoire) (ms)
Continuous Nominal Rating 40°C (kVA)
Standby Rating 27°C (kVA)
Efficiencies 4/4 load (%)
Air flow (m3/s)
Short circuit ratio (Kcc)
Direct axis synchro reactance unsaturated (Xd) (%)
Quadra axis synchro reactance unsaturated (Xq) (%)
Open circuit time constant (T'do) (ms)
Direct axis transient reactance saturated (X'd) (%)
Short circuit transient time constant (T'd) (ms)
Direct axis subtransient reactance saturated (X''d) (%)
Subtransient time constant (T"d) (ms)
Quadra axis subtransient reactance saturated (X"q) (%)
Zero sequence reactance unsaturated (Xo) (%)
Negative sequence reactance saturated (X2) (%)
Armature time constant (Ta) (ms)
No load excitation current (io) (ms)
Full load excitation current (ic) (A)
Full load excitation voltage (uc) (A)
Recovery time (Delta U = 20% transitoire) (ms)
Motor start (Delta U = 20% perm. or 50% trans.) (ms)
Transient dip (4/4 charge) - PF : 0,8 AR (%)
No load losses (kW)
Heat rejection (kW)
LEROY SOMER
LSA512M60
3
0.8
<1000
2250
4
AREP
H/H
R449
N/A
<50
<2
1
DIRECT
1
<700
2050
2200
95.7
2.5
0.35
357
214
2800
31.6
250
13.5
23
17.5
3.3
15.7
41
1.5
5.9
62
<700
4000
12
17.5
70.1
This document is not contractual - The SDMO company reserves the right to modify any of the characteristics stated in this CD Rom
without notice, in a constant effort to improve the quality of its products.
SDMO Industries – 12bis rue de la Villeneuve – CS 92848 – 29 228 BREST CEDEX 2
Tel +33 (0)2 98 41 41 41 – Fax : +33 (0)2 98 41 63 07 – www.sdmo.com
CONTROL PANEL
#STD_COFFRET
Standard
M80
M80
Specifications : Tachometer, Emergency stop button, client
connection terminal strip, EC certified
Engine parameters :Hours counter, Oil pressure gauge,
Water temperature indicator, Oil pressure indicator
Option
TELYS
TELYS
Specifications : Frequency meter, Ammeter, Voltmeter
Alarms and faults : Oil pressure, water temperature, No
start-up, Overspeed, Min/max alternator, Min/max battery
voltage, Low fuel level, Emergency stop
Engine parameters : Hours counter, Oil pressure, Water
temperature, Engine speed, Battery voltage, Fuel level
Option
KERYS
KERYS
Specifications : Frequency meter, Ammeter, Voltmeter
Alarms and faults : Oil pressure, water temperature, No
start-up, Overspeed, Min/max alternator, Min/max battery
voltage, Low fuel level, Emergency stop
Engine parameters : Hours counter, Oil pressure, Water
temperature, Engine speed, Battery voltage, Fuel level
Additional specifications :Website, Troubleshooting,
Assistance and Maintenance, Plotting and logging, Load
impact, 8 configurations available, Compliance with
international standards...
#OPT1
#OPT2
#OPT3
This document is not contractual - The SDMO company reserves the right to modify any of the characteristics stated in this CD Rom
without notice, in a constant effort to improve the quality of its products.
SDMO Industries – 12bis rue de la Villeneuve – CS 92848 – 29 228 BREST CEDEX 2
Tel +33 (0)2 98 41 41 41 – Fax : +33 (0)2 98 41 63 07 – www.sdmo.com
Download