Fire Alarm Systems | ZNS Series Wall‑mount Horn Strobes ZNS Series Wall‑mount Horn Strobes ▶ Pre‑wire the base and test the circuit wiring before the walls are covered ▶ Select continuous or temporal (Code 3) horn tones and 90 dBA or 95 dBA ▶ Select 24 V filtered DC (VDC) or unfiltered Full‑Wave‑Rectified (Vrms) input voltage ▶ Select candela settings of 15/30/75/110 cd and 135/185 cd The Cooper Wheelock ZNS Series Horn Strobes provide a selectable continuous or Code 3 horn tone when connected directly to the Fire Alarm Control Panel (FACP). They also provide a synchronized Code 3 horn tone and strobe when used with an FACP that incorporates the Wheelock synchronization protocol, a Wheelock Synchronization Module, or the Wheelock Power Supply. The ZNS Horn Strobes can be field set for high (HI) or low (LO) dBA sound output. Strobes are designed to flash at 1 flash per second minimum over their Regulated Voltage Range. The ZNS Horn Strobes are designed for use with either 24 V filtered DC (VDC) or unfiltered Full‑Wave‑Rectified (Vrms) input voltage. All inputs are polarized for compatibility with standard reverse polarity supervision of circuit wiring by an FACP. The ZNS Series Horn Strobes, like all Cooper Wheelock Z Series appliances, are designed for easy installation. The universal two-wire base allows a continuity check of the entire NAC circuit before any appliances are attached and allows the appliances to be installed after all finish work has been completed. The appliances simply snap onto the universal bases. Region Certification USA UL MCW models only: UCST: Audible Signal Appliances, General Signal (UL464) CSFM 7125-0785: 142 Installation/Configuration Notes Compatible Products The following products are compatible with the ZNS Series Horn Strobes: Category Product ID Product Description Control Panels D70221 Conventional FACP D7024 Conventional FACP D70242 Addressable FACP D91243 Addressable FACP D80243 Analog FACP D10024A3 Analog FACP SM‑12/24‑R Synchronization module (red) DSM‑12/24‑R Dual synchronization module (red) PS‑24‑8MC Power supply with built-in synchronization protocol Modules Power Supply Certifications and Approvals Cooper Wheelock holds these Listings and Approvals. ULSZ: Audible Signal Appliances (UL464) 1 The D7022 must be set for 24 V operation. www.boschsecurity.com 2 | ZNS Series Wall‑mount Horn Strobes 2 When used with a D7039 Multiplex Expansion Module, the Mechanical Properties D7024 becomes an addressable fire alarm control panel (FACP). Dimensions: 3 4.8 in. x 4.8 in. x 2.9 in. (122 mm x 122 mm x 74 mm) For synchronization, use the SM or DSM modules with these control panels and set the synchronization module for 24 VDC operation. Power Requirements Mounting Considerations Voltage Type The ZNS Horn Strobes snap onto the pre-installed ZBASE Two-wire Base. The ZBASE Two-wire Base flush mounts on single-gang, double-gang, 4 in. square, 4 in. octal, and 3.5 in. octal back boxes. Horn and Strobe Current Draw2 Volume Setting DC: Wiring Considerations The wiring terminals on the ZBASE Two-wire Base accept two appliance wires with diameters between 12 AWG (2.3 mm) and 18 AWG (1.2 mm) at each terminal. RMS: Current Draw High: 15 cd: 74 mA, 30 cd: 107 mA, 75 cd: 184 mA, 110 cd: 244 mA, 135 cd: 350 mA, 185 cd: 477 mA Low: 15 cd: 66 mA, 30 cd: 101 mA, 75 cd: 177 mA, 110 cd: 232 mA, 135 cd: 306 mA, 185 cd: 429 mA High: 15 cd: 133 mA, 30 cd: 189 mA, 75 cd: 285 mA, 110 cd: 383 mA, 135 cd: 491 mA, 185 cd: 681 mA Low: 15 cd: 116 mA, 30 cd: 169 mA, 75 cd: 274 mA, 110 cd: 369 mA, 135 cd: 469 mA, 185 cd: 659 mA Parts Included Quant. Component Voltage (input) 1 Horn Strobe Nominal: 24 VDC or Vrms 1 Two-wire base Range: 16 V to 33 V 1 Dust cover 2 2 Hardware packs 1 Literature pack Current Draw is the same for the Continuous Horn and Code 3 Horn Settings. Ordering Information Technical Specifications Audible Patterns and Ratings1 Pattern Continuous: Code 3: Volume Setting Sound Output1 High: 87 dBA Low: 81 dBA High: 82 dBA Low: 76 dBA 1 Sound output is a minimum UL rating based on sound power measurements at a distance of 10 ft (3 m) in a reverberant test room per UL464. Environmental Considerations Environment: Indoor, dry Relative Humidity: 93±2% maximum, non‑condensing Temperature (operating): +32°F to +120°F (0°C to +49°C) Americas: Bosch Security Systems, Inc. 130 Perinton Parkway Fairport, New York, 14450, USA Phone: +1 800 289 0096 Fax: +1 585 223 9180 security.sales@us.bosch.com www.boschsecurity.us Europe, Middle East, Africa: Bosch Security Systems B.V. P.O. Box 80002 5600 JB Eindhoven, The Netherlands Phone: + 31 40 2577 284 Fax: +31 40 2577 330 emea.securitysystems@bosch.com www.boschsecurity.com © Bosch Security Systems Inc. 2008 | Data subject to change without notice T4436611595 | Cur: en-US, V2, 28 Jan 2008 ZNS‑MCW‑FR Multi‑candela Wall‑mount Horn Strobe (red) ZNS-MCW-FR ZNS‑MCW‑FW Multi‑candela Wall‑mount Horn Strobe (white) ZNS-MCW-FW ZNS‑MCWH‑FR High‑candela Wall‑mount Horn Strobe (red) ZNS-MCWH-FR ZNS‑MCWH‑FW High‑candela Wall‑mount Horn Strobe (white) ZNS-MCWH-FW Accessories ZBASE Two‑wire Base Universal base for all ZNH Series Horns, ZRS Series Strobes, and ZNS Series Horn Strobes. ZBASE PS‑24‑8MC Power Booster Power Supply PS-24-8MC Asia-Pacific: Bosch Security Systems Pte Ltd 38C Jalan Pemimpin Singapore 577180 Phone: +65 6319 3450 Fax: +65 6319 3499 apr.securitysystems@bosch.com www.boschsecurity.com Represented by