series b, 12b - Pathway Lighting

advertisement
Fixture Type
APPROVAL
Lamp Type
Job Ref. / Location
SERIES B, 12B
STANDARD FEATURES
q
q
q
q
q
q
q
Dual Voltage Input - 120/277 VAC 60 Hz.
Factory cycle tested for reliability.
Shipped assembled, ready to install.
Easy mounting with keyhole slots and universal knockout mounting cluster.
Rugged 20 gauge steel construction, buff white baked
epoxy powder finish.
Standard with 2 top mounted lighting fixtures.
(May be field mounted on side of cabinet.)
Available with PAR-18 or PAR-36 lighting fixtures.
6 Volt - 12 Volt Emergency Lighting
Available with
CHARGER/BATTERY
q
q
q
q
q
q
q
q
Solid state, patented POWER PULSE* charger.
Sealed lead calcium maintenance free battery – 8 yr. life
expectancy.
Optional maintenance free nickel cadmium battery –
15 year life expectancy.
Low battery voltage disconnect, brownout, power-on latch, solid state switch.
Temperature compensation.
Controls: Red LED power on,
Yellow LED charge indicator.
Push to test switch.
D.C. fuse.
SAVE INSTALLATION TIME
Our exclusive "QUIK-E" mounting knockouts allow you to mount to a single
gang or 4" octagon junction box without
removing the "J" box screws.
* Patent No. 4890004
SELECTION GUIDE
MODEL NUMBERTOTAL D.C. WATTAGE
PAR-36
LAMP
D.C.
FOR SUSTAINED ILLUMINATION
LIGHTING FIXTURES
WATTAGE*
VOLTS
1.5 HOURS
2 HOURS
4 HOURS
B12-2L
B18-2L
B24-2L
12B24-2L
5.4
5.4
5.4
9
6
6
6
12
12
18
24
24
8
12
16
16
5
7
10
10
12B36-2L
9
12
36
24
14
*Note: Lamp type and/or wattage may be substituted to suit specific application requirements. (See separate data sheet)
NOMINAL DIMENSIONS
OPTIONAL LAMPS
HIGH INTENSITY INCANDESCENT
VOLTS
WATTS
12
12
6
6
6
7.2
12
7.2
18
25
q
q
q
q
q
HALOGEN
SUFFIX #
VOLTS
#
#
#
#
#
q
q
q
q
q
(
(
(
(
(
7.2 )
12 )
7.2 )
18 )
25 )
12
12
6
6
6
WATTS 8
12
6
8
12
SUFFIX#
#
#
#
#
#
( 8H )
(12H )
( 6H )
( 8H )
(12H )
OPTIONS
Item Add Suffix
Voltmeter................................................................. #– V
3 Ft. Cord Set........................................................... #– CP3
Polycarbonate Shield.................................................. #– PS6
Maintenance Free Nickel Cadmium Battery.................... #– NI
Time Delay for use with HID........................................ #– TD
Self Verified Systems.................................................. #– SVS
220 Volt 50Hz input........................................... # – 220V50Hz
All products manufactured in accordance with U.L. standard 924, and meet or
exceed requirements as established by the National Electrical Code Article 700 and
Life Safety Code NFPA101. Specifications subject to change without notice.
TECHNICAL DATA
INPUT.............. 120/277 VAC..............
OUTPUT........... 6 Volt D.C.....................
12 Volt D.C...................
D.C. Fuse......... 5 amps
60Hz - 4.5 VA
12 Watts / 90
18 Watts / 90
24 Watts / 90
24 Watts / 90
36 Watts / 90
minutes
minutes
minutes
minutes
minutes
EM9.0
CRMACD
Pathway Lighting Products, Inc., P.O. Box 591, Old Saybrook, CT 06475-0591
voice: 800.342.0592 • fax: 800.207.0090 • www.pathwaylighting.com • e-mail: sales@pathwaylighting.com