series n4x, 12n4x - Pathway Lighting

advertisement
Fixture Type
APPROVAL
Lamp Type
Job Ref. / Location
SERIES N4X, 12N4X
STANDARD FEATURES
q Dual Voltage Input - 120/277 VAC 60 Hz.
q Factory cycle tested for reliability.
q Shipped fully assembled, ready to install.
q Suitable for NEMA 4, 4X & 12 – Watertight & Corrosion Resistant.
q Rugged Grey Structural Thermoplastic Housing. Optional white epoxy finish.
q Corrosion Resistant Stainless Steel Hardware.
q Removable Hinged Access Door is Fully Gasketed to Insure Proper Seal.
q Watertight Integrity of Lighting Heads is Assured with the use of Construction Grade RTV Silicone Sealant.
q Mounting Provisions Provided. q Breather Vent.
6 Volt - 12 Volt NEMA 4X
Emergency Lighting
CHARGER/BATTERY
q Solid state, patented POWER PULSE* charger.
q Sealed lead acid maintenance free battery – 8 year life expectancy.
q Low battery voltage disconnect, brownout, power-on latch.
q Temperature compensation.
q Controls: Red LED power on.
q Push to test switch.
q D.C. load fusing. * Patent No. 4890004
SVS
SELF VERIFIED SYSTEM
SELECTION GUIDE
Available with
6
V
O
L
T
12
V
O
L
T
MODEL NUMBER
PAR-36 SEALED BEAM PAR-36 SEALED BEAM
LAMP
LIGHTING FIXTURES
LIGHTING FIXTURES
WATTAGE*
D.C.
HALOGEN
TUNGSTEN
HALOGEN/TUNGSTEN VOLTS
TOTAL D.C. WATTAGE
FOR SUSTAINED ILLUMINATION
1.5 2
4
HOURS
HOURS
HOURS
N4X12-2LH
N4X18-2LH
N4X24-2LH
—
N4X18-2L
N4X24-2L
6 / 0
8 / 9
8 / 9
6
6
6
12
18
24
8
12
16
5
7
10
12N4X24-2LH
12N4X36-2LH
12N4X50-2LH
12N4X100-2LH
12N4X180-2LH
12N4X24-2L
12N4X36-2L
12N4X50-2L
12N4X100-2L
12N4X180-2L
8 / 8
8 / 8
8 / 12
8 / 12
8 / 12
12
12
12
12
12
24
36
50
100
180
16
24
40
84
144
10
14
22
44
72
*NOTE: Lamp type and/or wattage may be substituted to suit specific application requirements. (Contact factory).
APPLICATIONS
NOMINAL DIMENSIONS
111/2"
3
133/4"
(171
/2")
45/8"
8"(12")
MountingCenter
Dimensionsin
(parenthesis)arefor
12N4X180-2LH
or
12N4X180-2L
only
4MountingHoles
5/ "Diameter
16
123/4"
(163
/4")
MountingCenter
13/4"
(123
/4")
(151/2")
TECHNICAL DATA
12 Volt Wire Runs for Remote Loads*
53/8"
(63
/8")
OPTIONS
Item Ideal for use in hostile environments where dirt, dust, oil, water
or corrosive elements such as salt, acids, alkalines, etc. are
present. Best suited in areas such as petro-chemical plants,
waste water treatment or processing plants. Although it may
be used outdoors, exposure to direct sunlight or high ambient
temperatures should be avoided.
Add Suffix/Prefix
Self Verified System...................................................#–SVS
Low Ambient Temperature Control......# – TC1 (120V), # – TC2 (277V)
Nickel Cadmium Battery............................................#– NI
3 Ft. Cord Set..........................................................#– CP3
Time Delay for use with HID.......................................#– TD
Lamp Disconnect......................................................#– LD
Tamperproof Screws.................................................#– TP
Side Mount Heads....................................................#– S
220V 50 H2 input....................................................#– 220V50
White Epoxy Finish....................................................W–#
Total
Allowable Wiring Distance
Watts............. #12 Wire.............. #10 Wire
12.....................178'....................... 283'
25......................85'........................ 135'
50......................42'......................... 67'
100.....................21'......................... 33'
*6 volt – Multiply Distance by .24
INPUT...........120/277 VAC....... 60Hz – 24 Watts
All products are manufactured in accordance with U.L. standard 924,
and meet or exceed requirements as established by the National Electrical Code Article 700 and Life Safety Code NFPA101.
Specifications subject to change without notice.
IU1.0
CDUECR
Pathway Lighting Products, Inc., P.O. Box 591, Old Saybrook, CT 06475-0591
voice: 800.342.0592 • fax: 800.207.0090 • www.pathwaylighting.com • e-mail: sales@pathwaylighting.com
Download