Middle School Library Roof Replacement 1501 N Street Bedford, Indiana 47421 School Board of Trustees Larry Arnold Kirsten Collier Beth Ritter Tracy Bailey Scott Gillespie Gary Holmes Donnie Branham President Vice President Secretary Member Member Member Member Drawing Index G-300 Ansi/Spri ES-1 Code Calculations A-301 Roof Plans - Existing, Demo, And New A-302 Details - Low Slope A-401 Reflected Ceiling Plan Administration Gary D. Conner Corbin Dietrich Steve Ritter Darren Waggoner Superintendent Director of Business Services Director of Facilities Director of Transportation Library Roof Area Roof Hatch Location plot scale 1"=1" Key Map Note: This Drawing Is Intended To Be Plotted In Color. If This Sheet Appears In Black And White, It Is Plotted Incorrectly. Discard And Obtain An Accurate Drawing. 630 Walnut Street - Jeffersonville, Indiana 47130 - (812) 282-9554 North Lawrence Community Schools Middle School Library Roof Replacement North Lawrence Community Schools 2' - 0" 2' - 0" 2' - 0" 630 Walnut Street Jeffersonville, IN 47130 1' - 0" 1' - 0" North East Lower Level Low Slope Workroom Roof 1' - 0" SITE PROPERTIES 2' - 0" WIND PRESSURES TYPICAL FM GLOBAL 8 FASTENER FIELD PATTERN B 90 MPH NO SH FIELD PERIMETER = 3'-0" WIDE CORNER = 6'-0" X 6'-0" ELL 22 PSF 33 PSF 33 PSF FIELD PERIMETER = 3'-0" WIDE CORNER = 6'-0" X 6'-0" ELL 60 PSF 75 PSF 75 PSF 7.1 Wind Design P Horizontal Design Pressure (outward force) Vertical Design Pressure (upward force) 2' - 0" 2' - 0" 2' - 0" 1' - 0" NOTE: FULLY ADHERED E.P.D.M Roof MEMBRANE INSTALLED TO MEET MANUFACTURER'S SPECIFICATIONS TO BE ELIGIBLE FOR A 20YEAR NDL WARRANTY TO INCLUDE: 90 MPH WIND SPEEDS, FM GLOBAL "MH" HAIL CLASSIFICATION, NO RESTRICTIONS TO OWNER'S ABILITY TO MAKE EMERGENCY REPAIRS. External Pressure Coefficient from table 3 Velocity Pressure at roof height from table 4 Importance Factor Wind Load from table 1 Safety Factor from table 2 = (GCp) * (qz) * I * factor (137) = -1.1 * 24 * 1.15 * 4.5 (224) = -1.8 * 24 * 1.15 * 4.5 Coping Leg = 6" = 0.50 SqFt/Ft Coping Cap Width = 17" = 1.42 SqFt/Ft Edge Flashing Face = 6" = 0.50 SqFt/Ft Coping Upward Force = Perimeter Edge Design Coping Outward Force= Calculations Edge Flashing Design = Resistance 112 194 Lb/ft Lb/ft "Extent of (6.4.) Fastener Spacing (see detail drawings) Increase by factor of two at corners per ES-1 (2.4.1)" 68 Lb/ft Building Width 86 Corner Region = 8.6 ft Building Height 30 Corner Region = 12 ft Use Lessor of Calculated Region But Not less than 3'-0" 0' - 6" 1' - 0" Workroom Roof Areas Roof edge Design Pressure 1' - 0" WIND UPLIFT RATINGS SURFACE ROUGHNESS (§1609.4.2) WIND SPEED (§1629.3) WIND BOURNE RISK (§1609.2) FM HAIL CLASSIFICATION 812-282-9554 812-282-9171 fax www.koverthawkins.com © COPYRIGHT by KovertHawkins ALL RIGHTS RESERVED Date: 2016-02-29 0' - 6" 1' - 6" TYPICAL FM GLOBAL 12 FASTENER PERIMETER PATTERN @ 1.5 X FIELD FASTENER QUANTITY Project: 1616.01 1 1/2" = 1'-0" HEK 12" = 1'-0" Ansi Spri ES-1 Code Calculations Checked By: 3 KrP Wind Uplift Ratings Drawn By: 1' - 6" 2 1' - 0" 1' - 0" 0' - 6" 1' - 0" 0' - 6" 1' - 0" 1' - 0" 0' - 6" 0' - 6" 8' - 6" 0' - 6" 0' - 6" Certified By: 0' - 6" 0' - 6" Revisions Area Of New ANSI SPRI ES-1 White Metal Perimeter Edge. Provide Double Fasteners At Corner Areas. 8' - 6" THE CONTRACTOR IS TO INCLUDE ALL FASTENERS REQUIRED BY THE ROOF MANUFACTURER FOR REQUIRED WIND UPLIFT RATINGS INDICATED ON DRAWINGS AND IN SPECIFICATIONS, WHETHER SHOWN ON THIS TYPICAL DETAIL OR NOT. NO EXTRAS WILL BE ALLOWED FOR FASTENING PATTERNS REQUIRED BY A PARTICULAR MANUFACTURER IN A PARTICULAR LOCATION. 1 8' - 6" AN ADDITIONAL "PEEL STOP" MAY BE REQUIRED PARALLEL TO AND 18" FROM ALL PERIMETERS BY THE MANUFACTURER IN ORDER TO PROVIDE THE REQUIRED WARRANTY FOR 90 MPH WIND SPEEDS. Typical FM GLobal Fastening Patterns 3/4" = 1'-0" Note: This Drawing Is Intended To Be Plotted In Color. If This Sheet Appears In Black And White, It Is Plotted Incorrectly. Discard And Obtain An Accurate Drawing. 8' - 6" 8' - 6" plot scale 1"=1" Notice The Architect/Engineer does not define the scope of individual trades, subcontractors, material suppliers, or vendors. Any sheet numbering system used which identifies disciplines is solely for the Architect/Engineer/s convenience, and is not intended to define a subcontractor's scope of work. Information regarding individual trades, subcontractors, material suppliers, and vendors may be detailed, described and indicated at different locations throughout these documents. No consideration will be given to requests for change orders for failure to obtain and review the complete set of drawings and specifications when preparing bids, prices, and quotations. Library Roof Area CH I T E CT A D I AN N 3675 E NO. ST E R GI E STATE OF AR N38°51.686' , W086°29.477' Details Provided Indicate The Minimum Level Of Workmanship/Craftsmanship Expected By The Architect. Manufacturers Often Have Additional Requirements To Allow Their Products To Adhere To Warranty Requirements. These Additional Requirements Are To Be Included As Required By The Manufacturer To Provide A Complete And Warrantable Roof System . No Reduction From The Contract Document's Details Provided Can Be Assumed Due To Omission From Manufacturer's Standard Details. I 1501 N Street Bedford, Indiana 47421 NOTE: TYPICAL FASTENING PATTERN DETAIL IS SHOWN TO INDICATE MINIMUM PATTERNS. EXISTING CONDITIONS, PULL OUT TESTS, ALONG WITH MANUFACTURER'S REQUIREMENTS MAY REQUIRE ADDITIONAL FASTENERS TO BE INSTALLED. North Lawrence Community Schools Note: L E. KO V Middle School Library Roof Replacement 8' - 6" 1' - 0" 0' - 6" 0' - 6" 8' - 6" D HA TYPICAL FM GLOBAL 16 FASTENER CORNER PATTERN @ 2 X FIELD FASTENER QUANTITY RT E R 1' - 0" 8' - 6" Sheet 4 Roof Hatch Location Library Roof - Wind Uplift Fastening PLan 1/8" = 1'-0" Key Map G-300 Ansi/Spri ES-1 Code Calculations 1/4" Per 12" Slope Of Tapered Insulation Over Base Layers Thickness, Unless Noted Otherwise. 4" Minimum Insulation Thickness In The Field. Add Tapers, Cricket, And Saddles As Required. 32' - 6 1/2" ± VTR 30' - 4 1/2" ± Remove Top Stone Decoration Salvage And Place On Ground For Owner's Use. Remove And Relocate Parapet Wall Mounted Electrical Disconnect, Junction Boxes, And Conduit 8 A-302 Re-Install Area Light Fixture Upon Completion Of New Metal Coping. Re-Route All Conduit Below Roof Deck. See Detail 4/A302 For Flashing Of Conduit Roof Penetration. Remove Area Lighting Fixture. Salvage For Reinstallation. RD Roof Drain See Details ORD Overflow Roof Drain. Set Overflow Flush On 1/4"/12" Roof Slope 8'-0" From Main Drain. See Details 2 / A-302 , 3 / A-302 , & 5 7 Install New Disconnect Near Fixture On Inside Of Parapet Wall. 4" Vent Through Roof. Verify Size. Adjust Locations To Avoid Conflicts With Equipment And Wall Flashings. See Detail 6 / A-302 A-302 2 / A-302 , 3 / A-302 , & 5 / A-302 / A-302 Large Vents On Curbs. Remove And Reinstall As Required To Install Flashing. Provide Crickets Or Saddles As Required To Prevent Ponding. See Details 1 / A-302 1/4" / 1'-0" Vent 630 Walnut Street Jeffersonville, IN 47130 Roof Legend 812-282-9554 812-282-9171 fax www.koverthawkins.com © COPYRIGHT by KovertHawkins ALL RIGHTS RESERVED 8' - 0" (typ) D4 Remove All Existing Cover-Boards, Insulation, And Abandoned B.U.R. Below To Expose The Structural Deck. (Complete Tear-Off) D5 Remove Only That Amount Of Roofing And Flashing Which Can Be Made Weather-Tight With New Materials During A One-Day Period Or Before The Onset Of Inclement Weather. D6 Completely Remove All Roof Drains And Sump Pans Throughout. Clean, Flush, And Prepare Piping For Replacement With New Drains. If Piping Is Concealed By A Hard Surface Inaccessible Ceiling Or Wall, Install 24"X24" Metal Access Panels In Surface Below As Required To Access Piping. Field Verify All Locations. Paint Access Panel To Match Adjacent Finishes. Typical At All Roof Drains. D7 All Mechanical Lines, Equipment, Conduit, And Wiring To Be Removed (As Required) From Atop Roof And Protected For Reinstallation. Coordinate Disconnection, Down Time, And Reconnection With Owner, Architect, And Work Under Other Contracts . Reinstall Electrical And Mechanical Items As Their Locations On The Roof Become "Dried In". Extend Wiring, Conduits, And Refrigerant Lines As Required By New Curb Heights. 1/8" = 1'-0" D8 All Satellite Dishes And Cabling Are To Be Protected And Re-Set In Original Locations And Orientations. (Work With Owner To Insure Proper Orientation Upon Completion ) D9 Existing Roof And Interior Spaces Must Be Protected From Weather During Demolition. D10 Phase All Work To Insure Protection Of Interior Occupants, Equipment, And Finishes From Inclement Weather And Construction Process. D11 Note: This Drawing Is Intended To Be Plotted In Color. If This Sheet Appears In Black And White, It Is Plotted Incorrectly. Discard And Obtain An Accurate Drawing. plot scale 1"=1" Notice The Architect/Engineer does not define the scope of individual trades, subcontractors, material suppliers, or vendors. Any sheet numbering system used which identifies disciplines is solely for the Architect/Engineer/s convenience, and is not intended to define a subcontractor's scope of work. Information regarding individual trades, subcontractors, material suppliers, and vendors may be detailed, described and indicated at different locations throughout these documents. No consideration will be given to requests for change orders for failure to obtain and review the complete set of drawings and specifications when preparing bids, prices, and quotations. All Existing Pitch Pockets Will Be Removed Prepared For Replacement With Appropriate Structural Type, Gooseneck Type, Or Flexible Pipe And Conduit Penetration Flashing Per Details Included Within This Projects Documents. D12 Existing Roof And Interior Spaces Must Be Protected From Weather During Demolition. D13 Phase All Work To Insure Protection Of Interior Occupants, Equipment, And Finishes From Inclement Weather And Construction Process. C8 Install New Pre-Manufactured Exposed Pipe And Conduit Support (Similar To Cooper B-Line's Dura-Blok) 48" O.C.. Provide New Supports To Hold Pipe And Conduit Above Roof Membrane @ 12" Minimum. C9 Provide Saddles, Side Saddles, And Channel Flashing At All Roof Top Equipment And Curbs As Required. C10 8 A-302 3 Library Roof - New Work Remove Mechanical Equipment From Roof Curbs As Required For New Roof Membrane Installation. Re-Install Immediately Upon Completion Of Flashing In Their Areas. Completely Replace All Roof Drains Throughout. Acceptable Roof Drains Are: Zurn Model Z100-E-ZC-C-GG-R-NH Wade Model 3000ADF-42-52-53-NH Josam Model 21500-AE-3-4-21-Z Jay R Smith Model 1015Y-R-C-G C11 Clean, Flush, And Prepare Piping For Replacement With New Drains. If Piping Is Concealed By A Hard Surface Inaccessible Ceiling Or Wall, Install 24"X24" Metal Access Panels In Surface Below As Required To Access Piping. Field Verify All Locations. Paint Access Panel To Match Adjacent Finishes. Typical At All Roof Drains. 1/8" = 1'-0" C12 C13 Protect New Roof Membrane From Damage And Tracking Or Residue Tracked By Foot Traffic Or In The Form Of Construction Dust. Phase Work To Protect New Work Below. (Ie: Demo And Upper Slope Work Before New And Lower Slope Work.) C14 Roof System Notes Protect Interior Occupants, Equipment, And Finishes, From Falling Construction Debris, Dust, And Inclement Weather, During All Phases Of This Project. Low Slope Fully Adhered 60 mil EPDM Installed To Meet Manufacturer's Specification To Be Eligible For A 20 Year NDL Warranty To Include: 90 mph Wind Speeds (Add "Peel Strips" As Required By The Manufacturer) FM Global "SH" Hail Classification, No Restrictions To Owner's Ability To Make Emergency Repairs. Note: Details Provided Indicate The Minimum Level Of Workmanship/Craftsmanship Expected By The Architect. Manufacturers Often Have Additional Requirements To Allow Their Products To Adhere To Warranty Requirements. These Additional Requirements Are To Be Included As Required By The Manufacturer To Provide A Complete And Warrantable Roof System . No Reduction From The Contract Document's Details Provided Can Be Assumed Due To Omission From Manufacturer's Standard Details. Library Roof Area Roof Hatch Location Project: 1616.01 Date: 2016-02-29 Certified By: I CH I T E C7 CT Remove All Flashing, Metal Edges, Cleats, Copings, Reglets, Bellows, Blocking, Gutters, Down Spouts, Pitch Pockets, And All Other Items Of Existing Construction Abandoned Or Made Obsolete By The Installation Of The New Roofing System And Components. A D3 D D I AN Remove All Existing EPDM , Bur, And Underlayment Down To Structural Roof Decking (Complete Tear-Off). RT E N Remove Surface Rust From All Metal, Conduits, Piping, And Roof Accessories Scheduled To Remain. Apply Paint Per Specification Sections 09900 & 09991 To All Non-Aluminum Metal Rooftop Accessories, Gas Lines, Conduits, And Equipment. STATE OF C6 N38°51.686' , W086°29.477' 2 Library Roof - Existing D2 A-302 AR Remove Top Stone Decoration Salvage And Place On Ground For Owner's Use. Remove Stone Parapet Wall Caps As Directed By Notes On Plan. 3675 Contractor To Install New Flashing, Boots, Metal Edges, Cleats, Copings, And Reglets Throughout To Replace Existing. Add Extensions To Vtr's And Curbs To Maintain 12" Minimum Height Above New Roof Surface. 1501 N Street Bedford, Indiana 47421 C5 E Install New Fully Adhered Energystar Rated 60 Mil E.P.D.M Roof Membrane Set In Squeegee Grade Adhesive For Field And Trowel Grade Adhesive For Flashing And Vertical Surfaces. All Laps And Seams Are To Be Hot Air Welded. NO. C4 ST E R Install 1/2" High Denisty Polyisocyanurate Cover Board Mechanically Fastened Through Insulation And Tapers To Existing Decking Below. See Sheet G-300 For Additional Fasteners Required Along Perimeters For Wind Uplift Protection. GI C3 8 D1 Drawn By: Provide 1/4" Per Foot Tapered Insulation, Saddles, And Crickets As Required. Install Tapers To Provide 4-Way Slope To Roof Drains. E 1/4" / 1'-0" C2 L Re-Route Coax Below Roof Deck. See Detail 4/A302 For Flashing Of Conduit Roof Penetration. VTR Install 5" Polyisocyanurate Insulation Consisting Of 2" Base Layer With 3" Upper Layer. Stagger All Joints North Lawrence Community Schools VTR C1 E. KO V 1/4" / 1'-0" General Roof And New Construction Notes Middle School Library Roof Replacement ORD Checked By: KrP SAT Revisions 1/4" / 1'-0" Remove Large Vent To Allow ReFlashing Of Equipment Curb. See Detail 1/A-302. Re-Set , Re-Paint Louvers And Sides. Apply White Liquid EPDM Coating To Top To Prevent Water Infiltration. Vent RD General Demolition Notes HEK A-302 ORD 1/4" / 1'-0" 83' - 11 1/2" ± 86' - 4 1/2" ± RD HA Remove And Relocate Antenna Coax From Rooftop. 8 1/4" / 1'-0" R Remove And Relocate Parapet Wall Mounted Electrical Junction Boxes And Conduit Sheet A-301 Key Map Roof Plans - Existing, Demo, And New Existing Structure Bolt and Washer (4 Typical) Use Pipe Sealer on Threads Add Or Modify Blocking As Required To Support New Roof Drain. Galvanized Cast Iron Flashing Clamp Remove And Re-Set Roof Hatch Or Equipment As Required Sealant Grommetted Fastener 12 Inches O.C. 5/A-302 630 Walnut Street Jeffersonville, IN 47130 Galvanized Cast Iron Dome Existing Structure 812-282-9554 812-282-9171 fax www.koverthawkins.com © COPYRIGHT by KovertHawkins ALL RIGHTS RESERVED Metal Extender Piece With Sealant Onto Backside Fully Adhered Flashing To Acceptable Substrate Fit Within Available Space Cast Iron Adjustable Sleeve Batten And Fasteners Roof Membrane System Weld Fully Adhered Membrane 1/4" Dens Deck Prime Rigid Insulation Provide Access Panel Below As Required. Paint To Match Existing Finishes. O-Ring Bolt (4 Typical) Teflon Washer (4 Typical) Roof Drain Existing Structural Deck Cast Iron Clamp Ring with O-Ring Groove Flat Gasket Existing Structure Date: 2016-02-29 Cast Iron Body Project: 1616.01 Note: Blocking Shall Be Securely Anchored To The Deck To Resist A Force Of 300 Pounds Per Lineal Foot In Any Direction. KrP Details Provided Indicate The Minimum Level Of Workmanship/Craftsmanship Expected By The Architect. Manufacturers Often Have Additional Requirements To Allow Their Products To Adhere To Warranty Requirements. These Additional Requirements Are To Be Included As Required By The Manufacturer To Provide A Complete And Warrantable Roof System . No Reduction From The Contract Document's Details Provided Can Be Assumed Due To Omission From Manufacturer's Standard Details. Note: Metal Extender Piece Is Required If Existing Counter Flashing Is Contaminated And Or Counter Flashing Fascia Is Less Than 4 Inches Wide. Fastened 12 Inches O.C. With Grommetted Fastener. 1 Note: HEK . Checked By: Tapered Insulation Sump Attached @ Minimum Of 2 Fasteners Per Board Drawn By: 2X Wood Blocking. Match Insulation Thickness Fit Within Available Space Roof Hatch -- Equipment Curb Flashing 1 1/2" = 1'-0" Roof Sump Receiver 1 1/2" = 1'-0" 2'-0" Insulation Sump. See Plan Detail 2/A-302 System Weld Seam And Seal Tight STRUCTURAL DECK INSULATE TO PREVENT CONDENSATION Medium Duty No-Hub Coupler Fitting With Stainless Steel Clamps. Fernco Heavy-Duty MD Yellow Shield No-Hub Connector, Installed With 80lbs Torque, Is The Basis Of Design. 2X WOOD BLOCKING TIGHT TO PENETRATION PERIMETER NOTE: BLOCKING SHALL BE SECURELY ANCHORED TO THE DECK TO RESIST A FORCE OF 300 POUNDS PER LINEAL FOOT IN ANY DIRECTION. Roof Drain Leader (Existing) Insulate Entire Underside Of Drain And Drain Leader System Within 10 LF of Drain Body. CONTRACTOR'S OPTION USE PRE MOLDED FLASHING SIMILAR TO: Lexor Flash-Tite wire outlet posts: (800) 268-2889 http://www.lexcor.net/product_profile.asp?RecID=100&catid=91 4 Wade # 3000ADF-42-52-53-NH (w/ galvanized cast iron dome) Sealant / Adhesive RIGID INSULATION SECURELY FASTENED Zurn # Z100-EA-ZC-C-GD-R-NH Note: Size Roof And Overflow Drain's Threaded Extension To Allow Insulation To Be Installed Under Adjustable Sleeve. See Detail 3/A-302 For Adjustable Height Drain Detail. Josam 21500-AE-3-4-21-Z 3 Provide And Install New Drain To Existing Drain Leader System. Install Transitions To Differing Leader Size As Required. Wood Blocking Sloped. Provide 1/2" Slope Towards Field Membrane. Fully Adhered Flashing Membrane With Welded Seams And Laps. Provide 3/4" Chamfer In Wood Blocking. Provide Access Panel Below And Paint To Match Existing Finishes As Required. 1 1/2" = 1'-0" Pipe Penetration 5 White Membrane Cap Termination Bar And Fasteners Typical Roof Drain Section - Single Ply Roof 1 1/2" = 1'-0" Termination Bar, Fasteners, And Cover Strip Required For Vertical Heights Over 30" Aluminum Tape (See Note) Flashing Membrane Note: This Drawing Is Intended To Be Plotted In Color. If This Sheet Appears In Black And White, It Is Plotted Incorrectly. Discard And Obtain An Accurate Drawing. Fastener And Washer Flashing, System Welded Fully Adhered Membrane 1/2" High Density Polyisocyanurate Coverboard Rigid Insulation Securely Fastened plot scale 1"=1" Notice The Architect/Engineer does not define the scope of individual trades, subcontractors, material suppliers, or vendors. Any sheet numbering system used which identifies disciplines is solely for the Architect/Engineer/s convenience, and is not intended to define a subcontractor's scope of work. Information regarding individual trades, subcontractors, material suppliers, and vendors may be detailed, described and indicated at different locations throughout these documents. No consideration will be given to requests for change orders for failure to obtain and review the complete set of drawings and specifications when preparing bids, prices, and quotations. 2X Wood Blocking Tight To Vent Perimeter Note: Aluminum Tape Is Required If Existing Penetration Is Contaminated. 6 Typical Vent Thru Roof Flashing 1 1/2" = 1'-0" 1/2" Exterior Grade Plywood, As Required By Roof Membrane Manufacturer Wood Blocking Sloped. Provide 1/2" Slope Towards Field Membrane. Fully Adhered Flashing Membrane With System Welded Seams And Laps. Flashing Strip ANSI/SPRI ES-1 Compliant Metal Fascia (Color To Be Selected By Architect) Provide 3/4" Chamfer In Wood Blocking. Termination Bar And Fasteners Continuous Metal Cleat Fastened 4 In. O.C., Staggered Using Galvanized Annular Ring Nails Or Other Acceptable Fastener. See Sheet G-300 For Fastening Requirements At Building Corners. 1/2" Exterior Grade Plywood, As Required By Roof Membrane Manufacturer Flashing Strip Structural Deck 1 1/2" = 1'-0" Add Or Modify Blocking As Required To Support New Roof Drain. Insulate Below Deck Drain Body And Leaders To Prevent Condensation. Typical Flexible Pipe & Conduit Penetration Flashing Typical Roof Drain Exploded View Roof Membrane 1/2" High Density Polyisocyanurate Coverboard Rigid Insulation. Thickeners Varies With Tapers Sealant Roof Membrane Existing Structural Deck 1/2" High Density Polyisocyanurate Coverboard Rigid Insulation. Thickeners Varies With Tapers 2x Wood Blocking. Match Insulation (And Taper) Thickness Blocking Shall Be Securely Anchored To The Deck To Resist A Force Of 300 Pounds Per Lineal Foot In Any Direction. Existing Structural Deck 2x Wood Blocking. Match Insulation (And Taper) Thickness Blocking Shall Be Securely Anchored To The Deck To Resist A Force Of 300 Pounds Per Lineal Foot In Any Direction. 7 Flashing Over Stone Coping 8 Existing Work To Remain Flashing Over Interior Parapet Wall 1 1/2" = 1'-0" Certified By: CH I T E CT A D I AN N AR STATE OF 3675 E NO. ST E R GI Sheet New Work 1 1/2" = 1'-0" I A-302 Details - Low Slope N38°51.686' , W086°29.477' Extend Flashing Minimum Of 1/2" Beyond Inside Of Flashing Collar Jay R Smith # 1015Y-R-C-CID Structural Roof Deck 1501 N Street Bedford, Indiana 47421 SECURELY ANCHOR TO STRUCTURAL DECK AND WOOD BLOCKING Set Drain Body On Manufacturer's Top Set Deck Plate. Secured To Roof Deck. See Plan Detail 2/A-302 For Additional Framing Below. D E FULLY ADHERED BASE FLASHING, Acceptable roof drains, with cast iron body, deck clamp, sump receiver, adjustable extension assembly, and galvanized cast iron dome, includes: RT E L Minimum 12" BATTEN AND FASTENERS Cast Iron Under-Deck Clamp North Lawrence Community Schools Polyisocyanurate Roof Insulation. 5" Minimum At Perimeter Of Insulation Sump. 2" Minimum At Roof Drain Body. WHITE PREMOLDED FLASHING BOOT FULLY ADHERED ENERGY STAR CAP SHEET AND DENSDECK PRIME Revisions 4-Way Slope Towards Drain 1/4" Per 12" Slope (Typical) E. KO V Adjustable Sleeve 1/2" High Density Polyisocyanurate Overlayment Board Roofing Membrane; Fully Adhered Middle School Library Roof Replacement Omit Insulation Sump At Overflow Drain And Provide Full Height Blocking To Allow Overflow Drain To Be Installed Flush With Finished Roof Surface. Roof Membrane Flashing, Fully Adhered in pe To Dra 4-Way Slo r 12" Slope e 1-1/2" ± P Sealant Bed Under Membrane At Flashing Flashing Collar STAINLESS STEEL HOSE CLAMP 2-3/8"Ø Toothed Membrane Plate At Each Corner And 12" O.C. HA Adjustable Drain With Strainer Dome SCHEDULE 80 PVC PIPE WITH GLUED FITTINGS SIZED TO ACCOMMODATE FLEXIBLE CONDUITS AT ROOF PENETRATION SEALANT NEOPRENE PLUG,INSTALLED FLUSH WITH END TO COMPLETELY SEAL ANNULAR SPACE Typical Roof Drain Plan R 2 Date: 2016-02-29 Project: 1616.01 Drawn By: Checked By: KrP HEK 630 Walnut Street Jeffersonville, IN 47130 812-282-9554 812-282-9171 fax www.koverthawkins.com © COPYRIGHT by KovertHawkins ALL RIGHTS RESERVED Remove And Replace All Ceiling Tiles. Ceiling Grid Is To Remain. Repair Broken Or Bent Members. 5. Install New 2'x2' Fine Fissured With A Tegular Edge Acoustical Ceiling Tiles (Similar to #1820 by Armstrong World Industries) After Paint Has Cured So Not To Stick To New Ceiling Tiles. 6. All Existing Light Fixtures and Ceiling Mounted Equipment (Whether Indicated by These Drawings or Not) Shall Remain In Relatively The Same Locations As Existing. RepairWater Damaged Wall Finishes And Paint To Match Adjacent Surfaces Note: This Drawing Is Intended To Be Plotted In Color. If This Sheet Appears In Black And White, It Is Plotted Incorrectly. Discard And Obtain An Accurate Drawing. plot scale 1"=1" Notice The Architect/Engineer does not define the scope of individual trades, subcontractors, material suppliers, or vendors. Any sheet numbering system used which identifies disciplines is solely for the Architect/Engineer/s convenience, and is not intended to define a subcontractor's scope of work. Information regarding individual trades, subcontractors, material suppliers, and vendors may be detailed, described and indicated at different locations throughout these documents. No consideration will be given to requests for change orders for failure to obtain and review the complete set of drawings and specifications when preparing bids, prices, and quotations. Library Roof Area Certified By: Roof Hatch Location CH I T E CT A D I AN N AR STATE OF 3675 E NO. ST E R Sheet A-401 Reflected Ceiling Plan N38°51.686' , W086°29.477' Apply A Minimum Of 2 Coats of Paint To Existing Grid And New Grid Members After Grid Modifications Are Complete As Required By Accepted Altenates. Paint Is To Be Similar To Sherwin Williams Proclassic® Interior Waterbased AcrylicAlkyd Satin B33W850 Series. Apply Primer As Recommended By Manufacturer. Paint Color Is To Be White. I 1501 N Street Bedford, Indiana 47421 4. D GI Repair Or Replace Bent Or Damaged 2'x2' Ceiling Grid Members As Required. L 3. RT E North Lawrence Community Schools Ceiling Grid Is to Remain, Unless Otherwise Noted. Middle School Library Roof Replacement 2. E. KO V Remove And Discard (Offsite) Existing Lay-In Ceiling Tiles Diagrammed By This Sheet. HA 1. E General Notes: R 3rd Floor Library Revisions All Ceiling Mounted Fixtures Are To Remain In Same Place.