WR3387 Network Control Unit

advertisement
WR3387
Network Control Unit
Lighting Control System
Network Control Unit (NCU)
Features:
• Networks up to 31 Local Interface
Units (LIU).
General
The NexLight Network Control Unit
(NCU) is a system level device used
to interface between various hosts and
the NexLight Lighting Control System.
The NCU connects to the Lighting
Control System through the NexLight
Local Interface Unit (LIU)
The NCU allows global capability for
controlling relays and dimmers in an
extensive lighting control system using
multiple WRT2050 Transmission Units.
The NCU will allow gateway
communication between the NexLight
Lighting Control System and any of the
following:
•
•
•
•
PC's
Intelligent Controllers
Building Management Systems
Monitor Control Software
•
Up to eight NCUs may be linked to
create a network that can control up
to 63,488 load or dimmer circuits
•
One RS-232 serial port for interfacing
to PC’s, intelligent controllers or
Building Managment Systems (BMS).
•
LED indicator communications status
from LIU to NCU and NCU to HOST.
•
LED indicator displays condition of
input and communication
•
Mounts in standard NexLight panels
secured by WR9910 straps
•
Communication speed to host can
be set via DIP switch.
Specifications
Model:
WR3387 Network Control Unit (NCU)
Electrical Inputs:
Voltage: 24 Vac, Class II.
Power Consumption:
Voltage: ±24 Vdc, Class II.
Current: 150 mA. (4W maximum load)
Circuit Type:
Communication Interface (NCU to host PC)
Direct connection (RS-232).
Network Communication (NCU to LIU)
Two-wire shielded (RS485).
NexLight is a registered tragemark of NORTHPORT ENGINEERING INC., Pub No. 0410.23
Phone: 218.828.3700
www.nexlight.com
Fax: 218.824.1568
WR3387
Network Control Unit
Lighting Control System
Communication Speeds:
NCU to Host PC:
1200 / 2400 / 9600 / 19200 baud
Distance between Host and NCU:
RS232 Communication Interface: 15 ft
maximum, direct connection.
Panel Space Requirement:
5 Spaces
Weight in lb (kg):
1.75 (0.794)
Figure 1. NCU dimensions in inches (millimeters)
Distance between NCU and Local Interface Unit LIU in Feet (Meters):
Wire Size AWG
16
18
20
3925 (1200)
2475 (750)
1725 (525)
NexLight is a registered tragemark of NORTHPORT ENGINEERING INC., Pub No. 0410.23
Phone: 218.828.3700
www.nexlight.com
Fax: 218.824.1568
WR3387
Network Control Unit
Lighting Control System
LIU
#1
NCU
LIU
#2
LIU
#3
any one system can interface
BACnet
Building Management System
Intelligent Controller
Lighting Control Software
WRT2050
WRT2050
WRT2050
#1
#2
#3
2-wire bus
2-wire bus
2-wire bus
256 Relays
+ Dimmers
256 Relays
+ Dimmers
256 Relays
+ Dimmers
Figure 2. NCU Example Network
The number of load control circuits may be limited by the host PC software or hardware.
See the host PC software and hardware specifications for capabilities.