WR3387 Network Control Unit Lighting Control System Network Control Unit (NCU) Features: • Networks up to 31 Local Interface Units (LIU). General The NexLight Network Control Unit (NCU) is a system level device used to interface between various hosts and the NexLight Lighting Control System. The NCU connects to the Lighting Control System through the NexLight Local Interface Unit (LIU) The NCU allows global capability for controlling relays and dimmers in an extensive lighting control system using multiple WRT2050 Transmission Units. The NCU will allow gateway communication between the NexLight Lighting Control System and any of the following: • • • • PC's Intelligent Controllers Building Management Systems Monitor Control Software • Up to eight NCUs may be linked to create a network that can control up to 63,488 load or dimmer circuits • One RS-232 serial port for interfacing to PC’s, intelligent controllers or Building Managment Systems (BMS). • LED indicator communications status from LIU to NCU and NCU to HOST. • LED indicator displays condition of input and communication • Mounts in standard NexLight panels secured by WR9910 straps • Communication speed to host can be set via DIP switch. Specifications Model: WR3387 Network Control Unit (NCU) Electrical Inputs: Voltage: 24 Vac, Class II. Power Consumption: Voltage: ±24 Vdc, Class II. Current: 150 mA. (4W maximum load) Circuit Type: Communication Interface (NCU to host PC) Direct connection (RS-232). Network Communication (NCU to LIU) Two-wire shielded (RS485). NexLight is a registered tragemark of NORTHPORT ENGINEERING INC., Pub No. 0410.23 Phone: 218.828.3700 www.nexlight.com Fax: 218.824.1568 WR3387 Network Control Unit Lighting Control System Communication Speeds: NCU to Host PC: 1200 / 2400 / 9600 / 19200 baud Distance between Host and NCU: RS232 Communication Interface: 15 ft maximum, direct connection. Panel Space Requirement: 5 Spaces Weight in lb (kg): 1.75 (0.794) Figure 1. NCU dimensions in inches (millimeters) Distance between NCU and Local Interface Unit LIU in Feet (Meters): Wire Size AWG 16 18 20 3925 (1200) 2475 (750) 1725 (525) NexLight is a registered tragemark of NORTHPORT ENGINEERING INC., Pub No. 0410.23 Phone: 218.828.3700 www.nexlight.com Fax: 218.824.1568 WR3387 Network Control Unit Lighting Control System LIU #1 NCU LIU #2 LIU #3 any one system can interface BACnet Building Management System Intelligent Controller Lighting Control Software WRT2050 WRT2050 WRT2050 #1 #2 #3 2-wire bus 2-wire bus 2-wire bus 256 Relays + Dimmers 256 Relays + Dimmers 256 Relays + Dimmers Figure 2. NCU Example Network The number of load control circuits may be limited by the host PC software or hardware. See the host PC software and hardware specifications for capabilities. NexLight is a registered tragemark of NORTHPORT ENGINEERING INC., Pub No. 0410.23 Phone: 218.828.3700 www.nexlight.com Fax: 218.824.1568